Sunteți pe pagina 1din 5

measurIT technologies

Case Study: Water Flow Test FLUXUS F601 Portable Flow Meter
New Ross, Co. Wexford, Ireland

Problem
Our Customer wanted to prove his water pump The Customer expected the water flow of 300NCMH
performance. and this value proved to be correct. We attach the test
report from this measurement.
Solution
The solution was the portable FLUXUS F601 - a robust The FLUXUS F601 Portable Flow Meter is an ideal
clamp-on flowmeter which is suitable for the non- tool for service work and quick control ultrasonic
invasive flow measurements. Clamp-on-transducers are measurements. The measurement is pressure
quickly fixed on the pipe, without process interruption independent and can take place on pipes of almost any
and without production stop. materials and on almost any liquid.

Installation Read more at www.measurIT.com/FLUXUS


Thanks to the automatic transducer detection and the
clear menu structure, the measurement is set up in a
few minutes.

Mark Radford, the representative of MeasurIT


Technologies Ltd. - ‘Once again F601 proved itself
to really be the 5 minute flowmeter. I just only had to
measure the wall thickness with the ultrasonic probe,
select pipe material and fluid from list, put the pipe
dimensions, select the measuring point and that’s it!
Immediately after the ENTER button was pressed, the
measured values appeared in the display. That was a
really quick job!’

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963
Flow Test Report Sxxxx 11 December 2008

Customer Name

Customer address details

Location New Ross

Parameters DEVICE: F 601-06010123

MODE: STORED

NAME: SCANDATA

CHAN: 1 (A:)

START: 05/12/2008 13:06:03

\COMMENTS

\PARAMS

Par.Record:

Meas. Point No.: A:9999

Pipe:

Outer Diameter: 154.0 mm

Wall Thickness: 2.0 mm

Roughness: 0.1 mm

Pipe Material: Stainless Steel

Lining: WITHOUT LINING

Medium: Water

Medium Temp.: 7C

Fluid pressure: 1.00 bar

Trancducer Type: CDQ1NZ712420


Sound Path: 2 NUM

Transducer Distance: 86.8 mm

Damping: 30 s

Full-Scale Val.: 0.01 m3/h

Current Loop: 0/20 mA

Storage Rate: 00:00:10 SAMPLES

Physic. Quant.: Volume Flow

Unit Of Measure: [m3/h]/[m3]

Numb.Of Meas.Val: 441


Datei: empfangene Daten[3]
Start: 05.12.08 / 13:06:03
Dauer: 1h:13min:20s
Name: '9999'

300,00
280,00
260,00
240,00
220,00
200,00
Volume Flow [m3/h]

180,00
160,00
140,00
120,00
100,00
80,00
60,00
40,00
20,00
0,00

13:06 13:14 13:22 13:31 13:39 13:47 13:56 14:04 14:12

S-ar putea să vă placă și