Sunteți pe pagina 1din 61

Teras Titanium

TERAS TITANIUM

RIG GENERAL DESCRIPTION & EQUIPMENT LIST

Teras Titanium

NOTE: This form is a suggested guide only and use of this form or any variation thereof shall be at the sole discretion and risk of the
user parties. It should be noted that the presence or absence of any equipment does not imply applicability of such equipment for a
particular drilling project. The International Association of Drilling Contractors and CAPE International disclaim any liability
whatsoever for loss or damages which may result from use of the form or Portions or variations thereof.

INTERNATIONAL ASSOCATION OF DRILLING CONTRACTORS

STANDARD FORMAT EQUIPMENT LIST


JACK-UP DRILLING UNIT
INSTRUCTIONS: The Standard Format Equipment List has been developed to provide a comprehensive summary of all
relevant items of equipment and to streamline the tender process for both contractor and operator. In order to obtain
maximum efficiency, users are advised to maintain the precise order of the format and to request/provide any
additional information on specific equipment as an addendum, referring to the appropriate section number.

TABLE OF CONTENTS

SECTION A - UNIT SPECIFICATIONS


General
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11

Main Dimensions/Technical Description


Storage Capacities
Jackup Systems
Operational Capabilities
Variable Loading
Environmental Limits
Mooring System
Marine Loading Hoses
Cranes, Hoists, and Materials Handling
Helicopter Landing Deck
Auxiliary Equipment

SECTION B - GENERAL RIG SPECIFICATIONS


B1
B2
B3
B4

Derrick and Substructure


Drawworks and Associated Equipment
Derrick Hoisting Equipment
Rotating System

SECTION C - POWER SUPPLY SYSTEMS


C1
C2

Rig Power Plant


Emergency Generator

SECTION D - DRILLSTRING EQUIPMENT


D1
Tubulars
D2
Handling Tools
D3
Fishing Equipment

SECTION E - WELL CONTROL/EQUIPMENT


E1

Diverter BOP
Page 2 of 61

Revised: 30/05/15

Teras Titanium

E2
E3
E4
E5
E6
E7
E8
E9
E10

Low Pressure BOP


High Pressure BOP
Other Blowout Preventers
BOP Control System
Choke Manifold
Flexible Choke & Kill Lines (BOP to Manifold)
Flexible BOP Control Hoses
BOP Testing Equipment
BOP Handling

SECTION F - MUD SYSTEM/BULK SYSTEM


F1
F2
F3

High Pressure Mud System


Low Pressure Mud System
Bulk System

SECTION G -CEMENTING EQUIPMENT


G1

Cement Equipment

SECTION H - INSTRUMENTATION/COMMUNICATION
H1
H2
H3
H4
H5
H6
H7
H8
H9

Drilling Instrumentation at Driller's Position


Drilling Parameter Recorder
Instrumentation at Choke Manifold
Standpipe Pressure Gauge
Deviation Equipment
Rig Communication System
Environmental Instrumentation
Navigation Instrumentation
External Communications Equipment

SECTION I
SECTION J - WORKOVER TOOLS
SECTION K - ACCOMMODATION
K1
K2

Offices
Living Quarters

SECTION L - SAFETY EQUIPMENT


L1
L2
L3
L4
L5
L6
L7
L8

General Safety Equipment


Gas/Fire/Smoke Detection
Fire Fighting Equipment
Breathing Apparatus
Emergency First Aid Equipment
Helideck Rescue Equipment
Emergency Warning Alarms
Survival Equipment

SECTION M - POLLUTION PREVENTION EQUIPMENT


M1
M2
M3
M4

Sewage Treatment
Garbage Compaction
Garbage Disposal/Grinder
Oily Water Separator

Page 3 of 61
Revised: 30/05/15

Teras Titanium

A.

UNIT SPECIFICATIONS

Rig Type
Unit/design/shape
Unit flag
Unit classification

116-C
3 legged Modu, Triangular
Marshall Islands
Cantilever Self Elevating Offshore
Platform, 3 Legged Modu

IMO Certification

Yes/no:

Year of construction
Construction yard

Yes 8754671
Sep-80
Vicksburg, Mississippi

A.1 MAIN DIMENSIONS/TECHNICAL DESCRIPTION


Light ship
Displacement at loadline
Overall Length of unit (including helideck)
Overall width of unit (including anchor racks)
Hull length
Hull width
Hull depth
Number of legs/length
Leg length available below hull
Type of leg
Leg spacing (center to center)

18873.03 Kips
22619.970 Kips
243.08 ft
226 ft
243 ft 1 in
200 ft 6 in
26 ft
3/410 ft
358 ft
Square
142 ft center Port leg to center Stbd leg and
129 ft center of Bow leg to Transverse center
of Aft legs

Independent leg or matt


Spud can diameter/bearing area
Spud can height
Spud can jetting system

Independent Leg
46 ft / 1585 sq ft
24 ft
Yes

Mat dimensions

N/A

Cantilever or slot
Skid-off

Cantilever
52 ft aft of transom w/ cantilever extension
w/ reduced drilling loads

Cantilever envelope
Reach AFT, from/to

24ft x 45ft
24ft / 52' W ITH EXTENSIONS

Transverse, Port/STB
Slot dimensions

12FT either side


N/A

Mat slot dimensions

N/A

Max. cantilever load

800 Kips, exclusive of Substructure, 270


lbs/sq ft between beams

Max. rotary load


Max. setback load
Fuel consumption (avg. drilling)
Accommodation for maximum no. of personnel
(See K.2.1)

1200 kips
450 Kips
65 bbls/day (Normal operation)
110

A.2

STORAGE CAPACITIES

Fuel
Drill water
Potable water

3089 bbls
11696 bbls
1078 bbls

Page 4 of 61
Revised: 30/05/15

Teras Titanium

Mud processing tank (see F.2)


Active liquid mud (See F.2)
Independent oil base mud storage
Independent base oil storage
Independent brine storage
Bulk bentonite/barite (See F3)
Bulk Cement (See F3)
Sack storage
Pipe rack
Miscellaneous storage area
Preload capacity
A.3
A.3.1

50 bbls
1467 bbls
N/A
27553.3 bbls
5440 cu ft
5440 cu ft
3500 sacks
3300 cu ft (below deck)
11945 KIPS

JACKUP SYSTEM
Jacking Systems

Make/type
No. of jacks or pinions
Maximum jacking load
Jacking speed
Rack chocks available

A.3.2

Yes/no:
Yes/no:
Yes/no:

LeTourneau / Rack and Pinion


16 pinions per leg / 3 legs
375 kips/ motor
90 ft/hour
No

Raw Water Systems (A Frame)

Pump location (Main Deck)


Suction distance below hull (max.)
Pump Manufacturer
Model
Type
Rating
Electrical
QTY
Material

Main Deck
101 FT.
PLEUGER
QT14ENL-3a & MI10-880-4
QN103-2a+MI10-490-2
500 m3/hr x 60 m head
116 kw @ 1750 rpm, 460v / 3 phase / 60Hz.
(2) each
Nickel Aluminum Bronze Construction
Impeller in Stainless Steel Duplex
184 A
3480 I/min
141 HP

Rated Current
Speed
Rated Motor Power
Dedicated preload pumps

The above Two Salt water pumps are utilized


for preload

Winch Model #
Capacity
Rope Length
Rated pull force
Speed
Rope diameter

JM
5ton
110m
50KN
9.5m/min
21.5mm
11KW
YZR160L
110V, 60HZ, 3Phases

Motor power
model
Power supply

A.4 OPERATIONAL CAPABILITIES


Maximum designed water depth capability
Outfitted max/min water depth capability
Normal minimum water depth capability
Draft at load line (deepest)
Drilling depth capability (rated)
Transit speed towed (historical avg)
Leg (spud can) below hull in transit
Maximum leg length permitted in tow

300 ft w tide and leg penetration of 25 ft


300
26 ft
15.47
30000 ft
N/A
N/A
N/A

Number of tugs for field tow


Associated minimum bollard pull per tug

3
Ocean tow : 12000
Field tow : 9000
Page 5 of 61

Revised: 30/05/15

Teras Titanium

Anti-roll system
Maximum preload reaction per leg
Bearing pressure at maximum preload
Thrusters

A.5

Yes/no:

N/A

VARIABLE LOAD CAPACITY (VL)

Transit VL capacity
Drilling VL capacity
Survival VL capacity
Jacking VL capacity
A.6

3461.3 KIPS
4961.3 KIPS
3461.3 KIPS
3461.3 KIPS

ENVIRONMENTAL LIMITS

Transit
Max. wave height

N/A
Rig Movers Discretion

Max. wave period


Max. wind velocity
Max. current velocity
Max. heave (double amplitude)
Max. pitch (double amplitude)
Max. roll (double amplitude)

N/A
60 mph
2 Knot
N/A
6 degree single amplitude
6 degree single amplitude

degrees:
degrees:

Working water depth


Drilling
Survival

300 FT.
Maximum 50 ft seas with 70 knot wind gust
Maximum 60 ft seas with 90 knot wind gust

Working water depth


Drilling
Survival

300 FT.
300 FT.

A.7
A.7.1

MOORING SYSTEM
Anchor Winches

Quantity
Make/model
Type (electric/hydraulic/diesel)
Total HP per winch
Rated pull
Control locations (local/remote/both)
A.7.2

02
Marathon LeTourneau W-1500-TS
Electric
75 HP
Pull Rated Capacity 27.2 T or 60000 lb
Local

Anchors

Quantity
Make/type
Weight
A.7.3

02

Anchor Lines

Wire
A.7.4

1 1/2 size
Towing Gear

Towing bridle size

Dia. 3 in x 60 ft stud chain, one end fitted with


N 7 Pear Link 1 x Towing plate 30 in x 30 in x
3 in thick 1 x Towing line Dia. 2 in x 25 m 82
ft)

Hook-up system
Rating
Spare bridle

Smith Bracket
250
No

A.7.5

Supply Vessel Mooring System

System description
Rating
Location (Port/stbd/both)

2 lines- 1-4'' x 45ft. 1-- 4'' x 65ft.


N/A
Port

Page 6 of 61
Revised: 30/05/15

NO
11,000 kips

Teras Titanium

A.8

MARINE LOADING HOSES

Location of loading manifolds (Port/stbd/both)


A.8.1

Port

Potable Water Hoses

Quantity
Size
Make/type
Color coding
Make/type connection
A.8.2

Yes/no:

Drilling Water House

Quantity
Size
Make/type
Color coding
Make/type connection

Yes/no:

A.8.3
Fuel Oil Hose
Quantity
Size
Make/Type
Color coding
Make/Type connection
A.8.4

Yes/no:

Yes/no:

Yes/no:

Base Oil Hose

1
5''
FLEX IMAK
Yes
Hammer Union

Yes/no:

Brine Hose

Quantity
Size
Make/Type
Color coding
Make/Type connection
A.8.8

1
4''
FLEX IMAK
Yes
Hammer Union

Same as liquid mud hose

Quantity
Size
Make/Type
Color coding
Make/Type connection
A.8.7

1
3''
FLEX IMAK
Yes
Hammer Union

Cement Hose

Quantity
Size
Make/Type
Color coding
Make/Type connection
A.8.6

1
3''
FLEX IMAK
Yes
Hammer Union

Mud Chemical Hose

Quantity
Size
Make/Type
Color coding
Make/Type connection
A.8.5

1
3''
FLEX IMAK
Yes
Hammer Union

Yes/no:

Other

1
3''
FLEX IMAK
Yes
Hammer Union
Chemical

Use
Quantity
Size
Make/type
Color coding
Make/Type connection

Yes/no:

1
5''
FLEX IMAK
Yes
Hammer Union

A.9 CRANES, HOISTS, AND MATERIAL HANDLING


A.9.1

Cranes Revolving

Quantity
Specification (API, etc.)

Three (3)
LeTourneau PCM-120
Page 7 of 61

Revised: 30/05/15

Teras Titanium

Make
Type
Location (frwd/aft/Port/stbd)
Boom length
Hook reach below main deck (block/whip)
Block capacities and hoisting speeds
Whip capacity and hoist speed
Hook load indicator automatically

LeTourneau Inc.
PCM-120
One each in Port, Stbd, Port Aft
100 ft each

Automatic brake
Safety latch on hooks
Crown saver (limit switch)
Boom illumination

Yes/no:

50 ton @25'
N/A
Yes
Yes

Yes/no:
Yes/no:
Yes/no:
Yes/no:

Yes
Yes
Yes
Yes

Quantity
Specification (API, etc.)
A.9.2

Forklifts

NA

Quantity
Make/Type
Rated capacity
Explosion proof
A.9.3

Monorail Overhead Cranes

Yes/no:
1.4.8.6

Quantity
Make
Type
Rated capacity

One (1)
JD Neuhaus
Trolley type
47.5 Ton, Main travel crane max speed=5/25
m/min, Cross travel (trolley) max speed=5/12
m/min, Hoist max speed=0,50 / 1,1 [m/min]
lifting / lowering
BOP Deck

Location(s)
A.9.4
A.9.4.1

Air Hoist/Derrick Winches


Rig Floor Winches (Non man-riding) 1.4.5.13

Quantity
Make
Type
Rated capacity
Wire diameter
Automatic brakes
Overload protection
Automatic spooling

One (1)
Ingersoll Rand
TNC 602040 W DP
2 Ton
Yes/no:
Yes/no:
Yes/no:

Quantity
Make

2
Ingersoll-Rand

Type
Rated capacity
W ire diameter
Automatic brakes
Overload protection
Automatic spooling

K6UL
5000 LB
5/8''
NO
NO
NO

A.9.4.2

Yes/no:
Yes/no:
Yes/no:

Monkey Board Work Winch

Quantity
Make
Type
Rated capacity
W ire diameter
Automatic brakes
Overload protection

One (1)
Ingersoll-Rand
EUAGP-PT
200 lbs
Yes/no:
Yes/no:
Yes/no:

Page 8 of 61
Revised: 30/05/15

Yes

Teras Titanium

A.9.4.3

Rig Floor "Man-Riding" Winch

Quantity
Make
Model
Type
SR #
Rated capacity
W ire diameter
Non-twisted wire
Automatic brake
Overload protection
Automatic spooling
Certified for man-riding
A.9.4.4

Yes/no:
Yes/no:
Yes/no:
Yes/no:

1
Ingersoll Rand
FA150KGI/D10064
MC336A-250-38-0
KG015269
335 LB
1/2''
Yes
Yes
NO
Yes
Yes

Utility Winch (i.e. Deck Winch)

Quantity
Make
Type
Rated capacity
W ire diameter
Automatic brake
Overload protection
Automatic spooling
Certified for man-riding
Locations

Yes/no:
Yes/no:
Yes/no:

1
Ingersol-Rand
K6UL
5000 LB
5/8''
NO
N
NO
N
BOW

A.9.4.5 BOP Hoists (see E.10.1)


A.9.5

Transfer Baskets/Containers

N/A

A.9.5.1 Personnel Transfer Baskets

One (1)
Billy Pugh Model X-871 Personal
Transfer with safety load line

A.9.5.2 Cargo Containers

N/A

Quantity
Make/Type
A.10

HELICOPTER LANDING DECK

Location (frwd/aft/Port/stbd)
Dimensions
Perimeter safety net
Load capacity
Designed for helicopter type

Stbd
60 ft in Diameter
Yes/no:
51250 lbs
Sikorsky S-61

Tie down points


Heli-refueling system type
Fuel storage capacity
Helideck lighting to aviation specification (see L.3.6)
A.10.1

Yes/no:
Yes/no:

Helicopter Refueling System

N/A

System make/type
Fuel storage capacity
Jettisonable
Fuel transport container, quantity

N/A

Fuel transport containers


Covered by foam fire system (see L.3.6)
A.11

AUXILIARY EQUIPMENT

Page 9 of 61
Revised: 30/05/15

4
N/A
N/A

Teras Titanium

A.11.1

Water Distillation

Quantity
Make/Type
Capacity (each/total)
Tag

One (1)
C-Treat M# FD301-4 Split Skid
7.5 GPM 10,800 GPD MAX
4500005629

A.11.2

N/A

Boilers

Quantity
Make/Type
Capacity (total system)
A.11.3

Air Conditioning

Quantity
Make/Type
Capacity (total system)
Max. temperature rating
A.11.4

6
Carrier
10 ton

Electric Welding Sets

Quantity
Current capacity

Two (2)
15 amp 115 VAC duplex receptacle allows
operators the flexibility to run grinders, drills,
coolers, etc. from power source without the
need for additional 115 VAC
power in weld area.

Make/model

Miller Dimension 652 CC/CV Electric welder

A.12.5

High Pressure Cleaner

Quantity
Make/Type
Electronic/pneumatic/diesel
Max delivered pressure

Yes/no:

Quantity
Make/Type
Electronic/pneumatic/diesel
Max delivered pressure

2
Diesel / Karcher
Diesel / Karcher
230 BAR
1
PSC ELECTRICAL
PNEUMATIC
4000 psi

Yes/no:

B.1

DERRICK AND SUBSTRUCTURE

B.1.1. Derrick/Mast
Make/Type
Rated for wind speed:

Lee C Moore, Model W -15236-11


N/A

Height
Dimensions of base
Dimensions of crown
Gross nominal capacity
Static hook load
Maximum Number of lines
Ladders with safety cages and rests
Platform for crown sheave access
Counter balance, system for rig tongs and

167 ft
30 ft x 30 ft
7' 10'' X 7' 10''
1,250,000 lbs
500 Ton
Yes, 12 lines
Fall arrest cables
Yes
Yes

Lighting system explosion proof

Yes/no:
Yes/no:
Yes/no:
Yes/no:
Yes/no:

Yes

B.1.2 Racking Platform


Make/Type
Total current simultaneous capacity - drill pipe
5" DP
6 - 5/8" DP
3- 1/2" DP
Total current simultaneous capacity - drill pipe

N/A
190 stands

Page 10 of 61
Revised: 30/05/15

Teras Titanium

8" DC
9" DC
Tubing belly board

Yes/no:

B.1.3 Automated Pipe Handling


B.1.4

N/A

Casing Stabbing Board

Make/Type

Deckard Manufacturing, Model "A" Board

Adjustable from/to height above rotary

Stabbing Board with 37 ft of travel

B.1.5

Substructure

Make/Type
Drill floor height (above main deck)
Length
Width
Setback capacity
Simultaneous setback-hook load capacity
Rotary beam capacity (total)
Clear height below rotary table beams
B.1.6

LeTourneau Inc.,
29 ft
450,000 lbs

Weather Proofing

Rig floor windbreaks


Derrickman windbreaks
Around process pits
B.1.7

Wind Walls
Tarp
enclosed

TV Camera System

Camera located at
Make/Type
Zoom/Pan/Tilt-function
Model #
Ex-proof
B.2
B.2.1

Monkey & Stabbing Board


Yes/no:
Yes/no:

Anson
Yes
HL-E8003d
Yes

DRAWWORKS AND ASSOCIATED EQUIPMENT


Drawworks

Make/Type
Motors make/type

National Oil Well, Model 1625-DE


Two GE 752 High Torque Shunt Wound
Motors, Model 5GE752R6A

Rated input power


Drum size (diameter x length)
Drum type (grooved/smooth)

2500 hp
36" Dia x 61-1/4" Long
Grooved

Break type (disk/drum)


Maximum line pull 12 lines
Maximum line pull 10 lines
Maximum line pull 8 lines
Make up cathead type
Breakout cathead type
Crown block safety devices

Drum
1520 kips
1300 kips
1065 kips
National Type "A1''
N/A
Koomey TCB Crown-O-Matic System

Independent fresh water cooling system for


Crown block safety device model
Automatic driller

Yes/no:

B.2.2

Yes
Koomey TCB

Yes/no:

Input power continuous

2500 hp

Auxiliary Brake

Make
Model
Independent back-up system type

Baylor El Maggo
Model 7838
NOV
Page 11 of 61

Revised: 30/05/15

10 stands for 9-1/2" DC


NO

Teras Titanium

B.2.3

Sandline

N/A

Make
Length capacity
Line size/type
Breaking strength
Safe working load
B.2.4

Slickline Unit

Make/model
Wire length (nominal)
Wire size
Breaking strength
Safe working load
Depth counter
Pull indicator
B.3

DERRICK HOISTING EQUIPMENT

B.3.1

Crown Block

N/A

Yes/no:

Make/Type
Rated capacity
No. of sheaves
Sheave diameter
Sheave grooved for line size
B.3.2

National Oil W ell, Model 760 FA


583 Tons
Seven(7)
60"
1-1/2"

Traveling Block

Make/Type
Rated capacity
No. of sheaves
Sheave diameter
Sheave grooved for line size
B.3.3

National Oil Well, Model 760 H


650 Tons
Six(6)
60"
1-1/2"

Hook

Make/Type
Rated capacity
Complete with spring assembly/hook locking
Yes/no:
B.3.4

Swivel

Make/Type
Rated capacity
Test/working pressure
Gooseneck and wash pipe minimum ID
Left hand pin connection size
Access fitting for wireline entry on top of

B.3.5

N/A

Yes/no:

Drilling Line

Diameter
Construction
Length (original)
Drilling line reel

1-1/2"
6 x9, IPS, RRL, IW RC
10,000 ft

Spare drilling line

Yes/no:
Yes/no:
Yes/no:

Roller guides

Yes/no:

B.3.6

BJ, Model Dyna Plex


500 Tons
Yes
Yes

Dead Line Anchor

Make/Type
W eight sensor
Deadline dampener

National Type EB
Yes/no:
Yes/no:

B.3.7 Block Guidance System (If Applicable)


Make/Type

Wool Slayer
Page 12 of 61

Revised: 30/05/15

Teras Titanium

B.4

Rotating System

B.4.1 Rotating Table


Make/Type
Maximum opening
Rated capacity
Two speed gearbox
Emergency chain drive
Driven by an independent electric motor

Yes/no:
Yes/no:
Yes/no:

NO
No( Drawwork motor)

Drip pan/mud collection system

Yes/no:

Yes

B.4.2

ZP Model 375
37.5"
900 kips

Master Bushings

Yes
ZP
01 Set
N/A
ZP
01 Set

Qty
Make/Type
Inserts bowls (see G.1.8)
Qty
B.4.3

Kelly Bushing

Make/Type
Lock down assembly
B.4.4

Yes/no:

Top Drive

Make
Type (electric/hydraulic)
Rated capacity
Test/working pressure
Output power
Maximum continuous torque
Two speed gear box
Maximum rotary speed
Remote operated kelly cock
Cooling system type

Varco TDS - 4
Electric
650 TONS
5000 PSI
1130 hp Continuous
1365 hp Intermittent
Yes/no:

50100 ft lbs
Yes
130 RPM LOW 180 High

Yes/no:
Flow 3200 CFM, HP 25, PSI 17" H2O, Heat
exchange 150,000 BTU/hr, Water supply 40
GPM@250 ft of Head

Upper inside BOP (see also D.1.15)


B.4.4.1

Top Drive

Make/type
Model
Max. makeup torque
Max. breakup torque
Raised backup system
C.
C.1

Varco TDS - 4
TDS-4
Yes/no:

POWER SUPPLY SYSTEMS


RIG POWER PLANT

Quantity
Make/Type
Maximum continuous power
Equipped with spark arrestors
Mufflers installed
C.1.2

DC - Generator

C.1.3

AC - Generator

Six (6)
Caterpillar Model D-3512 V12
1281 hp @ 1200 rpm
Yes/no:
Yes/no:

N/A

Quantity
Make/Type
Continuous power

6
Rockwell Automation Kato
1050 KW

Output volts

600 Volts AC

Page 13 of 61
Revised: 30/05/15

Yes
Yes

Teras Titanium

C.1.4

SCR System

Number of SCR
Make/Type
Maximum continuous power (total)
Output volts
C.1.5

Seven (7)
GE

Transformer System

Quantity
Make/Type
Continuous power (each)
Output volts
Frequency
C.1.6

Three (3)
HAMMOND, Type 1000KVA
480 V
60 HZ

Emergency Shutdown

Emergency shutdown switches for the complete power system


(AC and DC), located at the following points
C.1.7

Compressed Air Systems

Air Compressors - Cold Start


Quantity
Manufacturer
Type
Pressure Rating
Air Compressors - Medium Pressure (rig air)
Quantity
Manufacturer
Type
Pressure Rating
SR #
Pressure Rating

One(1)
Quincy
5 hp Diesel and Electric
130 psi
One(1)
Quincy
QA1245-2
200 psi max / 173 cu ft min
96049HOSI245ANA320
130 psi

Air Compressors - Medium Pressure (rig air)


Quantity
Manufacturer
Type
Pressure Rating
SR #

One(1)
Quincy
QA1245-2
200 psi max / 173 cu ft min
96049HOSI245ANA320

Quantity
Manufacturer
Type
Pressure Rating
SR #
MOD #

Two(2)
Quincy
370 Screw Type
93169J & 129135-1
QSI370ANA325D

Air dryers
Quantity
Manufacturer
Type

Two (2)
Quincy
Model Opnc 750

Air Compressors - Low Pressure (bulk air)


Quantity
Manufacturer
Type
Pressure Rating

Two (2)
Quincy
Qslp-30
150 PSI
364.0 acfm
UN076485-6
QSLP3000008

SR #
P#
Air dryers

1
Quincy
Model Opnc 500

C.1.8

Total Three (5)

Air Receivers

Volume (total)
Pressure

480 Gallon
150 psi
Page 14 of 61

Revised: 30/05/15

On Rig Floor
In front of Living Quarters

Teras Titanium

Location

Mud Pump Room

Volume (total)
Pressure
Location

480 Gallon
150 psi
Mud Pump Room

Volume (total)
Pressure
Location

480 Gallon
150 psi
Mud Pump Room

Volume (total)
Pressure
Location

480 Gallon
150 psi
Rig Floor

Volume (total)
Pressure
Location

240 Gallon
150 psi
Engine Room

C.2 EMERGENCY GENERATOR


C.2.1 Engine
Quantity
Make/Type

One(1)
Caterpillar, Model D-379, 4V-8, Turbocharged w/ closed cooling system

Maximum output
Automatic starting
Starting methods (air, hydraulic, battery)

Yes/no:

Max. angle of operation

degrees:

400 KW
Yes
Automatically start upon loss of Normal
Power

C.2.2 AC-Generator
Quantity
Make/Type

One(1)
Kato, Model 400-683361111, Type
19764
400 KW

Maximum output
Output
Capable of back-feeding power to main bus
D.
D.1
D.1.1

Yes/no:

Yes

DRILLSTRING EQUIPMENT
TUBULARS

N/A

Kellies

Quantity
Nominal size OD
Shape type (hexagonal, square or triangular)
Total/working length
Connection type
Quantity
Nominal size OD
Shape type (hexagonal, square or triangular)
Total/working length
Connection type
D.1.2

Kelly Saver Subs

Quantity
Nominal kelly size
Connection type
Protector
D.1.3

N/A

Yes/no:

Drill Pipe

Drill pipe OD
Grade
Total length
Range
W eight
Internally plastic coated

Yes/no:
Page 15 of 61

Revised: 30/05/15

Teras Titanium

Tool joint OD/ ID


Tool joint pin length (original)
Tapered shoulder tool joints (box/pins)
Connection type
Type of hardfacing
API Classification
Thread protectors
Drill pipe OD
Grade
Total length
Range
W eight
Internally plastic coated
Tool joint OD/ ID
Tool joint pin length (original)
Tapered shoulder tool joints (box/pins)
Connection type
Type of hardfacing
API Classification
Thread protectors
Type of hardfacing
API Classification
Thread protectors
Drill pipe OD
Grade
Total length
Range
Weight
Internally plastic coated
Tool joint OD/ ID
Tool joint pin length (original)
Tapered shoulder tool joints (box/pins)
Connection type
Type of hardfacing
API Classification
Thread protectors
D.1.4

degree:

Yes/no:

Yes/no:
degree:

Yes/no:

Yes/no:

Yes/no:
degree:

Yes/no:

Drill Pipe Pup Joints

Tool joint OD/ID


Grade
Length
Length
Length
Weight
Connection type
Internally plastic coated
API classification
Thread protectors

Yes/no:
Yes/no:

Tool joint OD/ID


Grade
Length
Length
Length
Weight
Connection type
Internally plastic coated
API classification
Thread protectors

Yes/no:
Yes/no:

Tool joint OD/ID


Page 16 of 61
Revised: 30/05/15

Teras Titanium

Grade
Length
Length
Length
W eight
Connection type
Internally plastic coated
API classification
Thread protectors
D.1.5

Yes/no:
Yes/no:

Drill Pipe Casing Protectors

Initial stock
Make/Type
OD
Installation tools (manual/hydraulic/none)
Initial stock
Make/Type
OD
Installation tools (manual/hydraulic/none)
D.1.6

Hevi-Water Drill Pipe

Quantity
Nominal size OD
Weight
Range
Tool joint OD
Tool joint ID
Type of hardfacing
Internally plastic coated
Connection type
Thread protectors
Quantity
Nominal size OD
W eight
Range
Tool joint OD
Tool joint ID
Type of hardfacing
Internally plastic coated
Connection type
Thread protectors
D.1.7

Yes/no:
Yes/no:

Yes/no:
Yes/no:

Drill Collars

Quantity
OD body
ID body
Average Length of each joint
Drill collar body (slick/spiral)
Recess for "zip" elevator
Recess for slips
Stress relief pin groove
Boreback on box
Connection type

Yes/no:
Yes/no:
Yes/no:
Yes/no:

Quantity
OD body
ID body
Average Length of each joint
Drill collar body (slick/spiral)
Recess for "zip" elevator
Recess for slips
Stress relief pin groove
Boreback on box
Connection type

Yes/no:
Yes/no:
Yes/no:
Yes/no:
Page 17 of 61

Revised: 30/05/15

Teras Titanium

Quantity
OD body
ID body
Average Length of each joint
Drill collar body (slick/spiral)
Recess for "zip" elevator
Recess for slips
Stress relief pin groove
Boreback on box
Connection type
Quantity
OD body
ID body
Average Length of each joint
Drill collar body (slick/spiral)
Recess for "zip" elevator
Recess for slips
Stress relief pin groove
Boreback on box
Connection type
D.1.8

Quantity
OD body
ID body
Nominal length of each joint
Stress relief pin groove
Boreback on box
Connection type
Quantity
OD body
ID body
Nominal length of each joint
Stress relief pin groove
Boreback on box
Connection type
Quantity
OD body
ID body
Nominal length of each joint
Stress relief pin groove
Boreback on box
Connection type

N/A

Yes/no:
Yes/no:

Yes/no:
Yes/no:

Yes/no:
Yes/no:

Yes/no:
Yes/no:

Non-Magnetic Drill Collars

Quantity
OD body
ID body
Nominal length of each joint
Drill collar body (slick/spiral)
Recess for "zip" elevator
Recess for slips
Stress relief pin groove
Boreback on box
Connection type
D.1.10

Yes/no:
Yes/no:
Yes/no:
Yes/no:

Short Drill Collars

Quantity
OD body
ID body
Nominal length of each joint
Stress relief pin groove
Boreback on box
Connection type

D.1.9

Yes/no:
Yes/no:
Yes/no:
Yes/no:

N/A

Yes/no:
Yes/no:
Yes/no:
Yes/no:

Core Barrels

N/A

Quantity
Make
Model
Page 18 of 61
Revised: 30/05/15

Teras Titanium

Size OD x ID
Length
Top connection Type
Spiral stabilizing ribs
Subs and handling tools
D.1.11

Yes/no:
Yes/no:

Stabilizers

N/A

Hole size
Quantity
Make
OD blades
Type blades
Type of blade hardfacing
OD body or fishing neck
ID body
Connection type
Float valve receptacle

Yes/no:

Hole size
Quantity
Make
OD blades
Type blades
Type of blade hardfacing
OD body or fishing neck
ID body
Connection type
Float valve receptacle

Yes/no:

Hole size
Quantity
Make
OD blades
Type blades
Type of blade hardfacing
OD body or fishing neck
ID body
Connection type
Float valve receptacle

Yes/no:

Hole size
Quantity
Make
OD blades
Type blades
Type of blade hardfacing
OD body or fishing neck
ID body
Connection type
Float valve receptacle
D.1.12

Yes/no:

Roller Reamers

N/A

Hole size
Quantity
Make/Type
OD body
ID body
OD fishing neck
Cutters supplied sets
Connection type
Hole size
Quantity
Make/Type
OD body
ID body
OD fishing neck
Cutters supplied sets
Page 19 of 61
Revised: 30/05/15

Teras Titanium

Connection type
Hole size
Quantity
Make/Type
OD body
ID body
OD fishing neck
Cutters supplied sets
Connection type
D.1.13

Shock Absorbers

N/A

Quantity
Make/Type
OD body
ID body
OD fishing neck
Connection type
Quantity
Make/Type
OD body
ID body
OD fishing neck
Connection type
D.1.14

Drilling Jars

N/A

Quantity
Make
Type (mechanical/hydraulic) up/down
OD body
Min. ID body
OD fishing neck
Stroke
Connection type
Quantity
Make
Type (mechanical/hydraulic) up/down
OD body
Min. ID body
OD fishing neck
Stroke
Connection type
Quantity
Make
Type (mechanical/hydraulic) up/down
OD body
Min. ID body
OD fishing neck
Stroke
Connection type
D.1.15

Inside BOP Valve

N/A

Quantity
Make
Size
Min. drill pipe ID required
Connections (type)
Connections OD
Working Pressure
Quantity
Make
OD
Min. ID
Page 20 of 61
Revised: 30/05/15

Teras Titanium

Connection type
Working Pressure
D.1.16

Fast Shut-Off Coupling

N/A

Make/Type
Quantity
Size tooljoint to fit
Make/Type
Quantity
Size tooljoint to fit
D.1.17

Circulation Head

Quantity
Make/Type
Bottom connection type
Top connection type
Wireline stripper
Working pressure

Quantity
Make/Type
Bottom connection type
Top connection type
Wireline stripper
Working pressure
D.1.18

N/A

Yes/no:

Yes/no:

Kelly Cocks

N/A

Upper

Lower

Yes/no:

Yes/no:
D.1.19 Circulation Subs

N/A

Quantity
Make/Type
OD body
Ball size
Dressing kits
Connection type
Quantity
Make/Type
OD body
Ball size
Dressing kits
Connection type
D.1.20

Cup Type Testers

N/A

Quantity
Make
Page 21 of 61
Revised: 30/05/15

Teras Titanium

Size
Connection type
Quantity
Make
Size
Connection type
D.1.21

Plug Type Testers

N/A

Quantity
Make
Size test plugs
Connection type
Quantity
Make
Size test plugs
Connection type
Quantity
Make
Size test plugs
Connection type
D.1.22

Drop-In Valves

N/A

Quantity
For nom. OD drillpipe
Make/Type
Max. OD of dart.
Quantity
For nom. OD drillpipe
Make/Type
Max. OD of dart.
Quantity
For nom. OD drillpipe
Make/Type
Max. OD of dart.
D.1.23

Near-Bit Subs (Box-Box)

Quantity
OD size
ID size
Top connection
Bottom connection
Bored for float valve
Float size
Quantity
OD size
ID size
Top connection
Bottom connection
Bored for float valve
Float size
Quantity
OD size
ID size
Top connection
Bottom connection
Bored for float valve
Float size

Yes/no:

Yes/no:

Yes/no:

Quantity
OD size
Page 22 of 61
Revised: 30/05/15

Teras Titanium

ID size
Top connection
Bottom connection
Bored for float valve
Float size
Quantity
OD size
ID size
Top connection
Bottom connection
Bored for float valve
Float size
D.1.24

Yes/no:

Yes/no:

Crossover Subs

Quantity
OD size (max/min)
ID size
Top connection size
Bottom connection size
Quantity
OD size (max/min)
ID size
Top connection size
Bottom connection size
Quantity
OD size (max/min)
ID size
Top connection size
Bottom connection size
Quantity
OD size (max/min)
ID size
Top connection size
Bottom connection size
Quantity
OD size (max/min)
ID size
Top connection size
Bottom connection size
Quantity
OD size (max/min)
ID size
Top connection size
Bottom connection size
Quantity
OD size (max/min)
ID size
Top connection size
Bottom connection size
Quantity
OD size (max/min)
ID size
Page 23 of 61
Revised: 30/05/15

Teras Titanium

Top connection size


Bottom connection size
Quantity
OD size (max/min)
ID size
Top connection size
Bottom connection size
Quantity
OD size (max/min)
ID size
Top connection size
Bottom connection size
Quantity
OD size (max/min)
ID size
Top connection size
Bottom connection size
Quantity
OD size (max/min)
ID size
Top connection size
Bottom connection size
D.1.25

Drilling Bumper Subs

N/A

Quantity
Make
OD
Stroke
Connection type
Quantity
Make
OD
Stroke
Connection type
Quantity
Make
OD
Stroke
Connection type
Quantity
Make
OD
Stroke
Connection type
D.1.26

Hole Openers

N/A

Quantity
Make
Size
Connection type
Quantity
Make
Size
Connection type
Page 24 of 61
Revised: 30/05/15

Teras Titanium

D.1.27

Underreamer

N/A

Quantity
Make/Type
OD min/OD max
Connection type
Quantity
Make/Type
OD min/OD max
Connection type
D.2
D.2.1

HANDLING TOOLS
Drill Pipe Elevators

Size
Quantity
Make
Model
Rated capacity

3-1/2"
One(2)
VARCO BJ
GG
250 TON

Size
Quantity
Make
Model
Rated capacity

5"
Two(1)
VARCO BJ
GG-31068

Size
Quantity
Make
Model
Rated capacity
Size
Quantity
Make
Model
Rated capacity
D.2.2

5-1/2''
One (1)
VARCO
GG-31068
350 TON

Drill Collar Elevators

Size
Quantity
Make
Model
Rated capacity

4-3/4''
1
VARCO
W TM
225 TON

Size
Quantity
Make
Model
Rated capacity
Size
Quantity
Make
Model
Rated capacity
Size
Quantity
Make
Model
Rated capacity
D.2.3

Tubing Elevators

Size
Quantity
Make
Model
Rated capacity

2-7/8" to 2-3/8"
One(1)
BJ
HYT
150 T

Page 25 of 61
Revised: 30/05/15

Teras Titanium

D.2.4

Drill Pipe Hand Slips

Size
Quantity
Make/Type

5"
Two(2)
VARCO SDXL

Size
Quantity
Make/Type

5'' DP
2
VARCO SDXL

Size
Quantity
Make/Type

3-1/2'' DP
2
VARCO SDXL

D.2.5

Casing Slips

Size
Quantity

7"
One (1)
VARCO

Size
Quantity
Make/Type

9-5/8
One (1)
VARCO

Size
Quantity
Make/Type

13-5/8''
One 01
VARCO

Size range
Quantity
Make/Type

18-5/8"
One(1)
VARCO BJ DCS-S-L

D.2.6

Drill Collar Slips

Size range
Quantity
Make/Type

7-1/4"
One(1)
VARCO

Size range
Quantity
Make/Type

6-1/2"
One(1)
VARCO

Size range
Quantity
Make/Type

4-3/4"
One(1)
VARCO

D.2.7

Drill Collar Safety Clamps

Quantity
Range
D.2.8

Two(2)
Varco Type MP-R ranging 2-7/8" to 9-1/2"
Tubing Slips

N/A

Size
Quantity
Make/Type
D.2.9

Tubing Spider

N/A

Slip size (max/min)


Quantity
Make
Adaptor plate
D.2.10

Drill Collar Lifting Subs

Quantity
For OD DC
Connection type

1
9''
7-5/8'' REG

Quantity
For OD DC
Connection type

5
8''
6-5/8'' REG
Page 26 of 61

Revised: 30/05/15

Teras Titanium

Quantity
For OD DC
Connection type

8
6-1/2''
4-1/2'' IF

Quantity
For OD DC
Connection type

3
4-3/4''
3-1/2'' IF

D.2.11

N/A

DC Lifting Plugs

Quantity
For OD DC
Connection type
Quantity
For OD DC
Connection type
Quantity
For OD DC
Connection type
Quantity
For OD DC
Connection type
D.2.12

Bit Breakers

Quantity
For bit size

One(1)
6"

Quantity
For bit size

One(1)
6-1/2"

Quantity
For bit size

One(1)
12-1/4"

Quantity
For bit size

One(1)
17-1/2"

Quantity
For bit size

One(1)
24-1/2"

D.2.13

Elevator Links

Quantity of sets
Make/Type
Size
Length
Rated capacity

One set

Quantity of sets
Make/Type
Size
Length
Rated capacity

One set

Quantity of sets
Make/Type
Size
Length
Rated capacity

One set

D.2.14

N/A

144"
350 Ton

180"
350 Ton

108"
350 Ton

Kelly Spinner

Make/Type
D.2.15

Drill pipe Spinner

Make/Type
Size
D.2.16

VARCO SSW 30
2-7/8'' TO 8''

Mud Saver Bucket

Make

SUB DRILL MS-V3A


Page 27 of 61

Revised: 30/05/15

Teras Titanium

Size

2-3/8''------6-5/8''

Make
Size
D.2.17

Hydraulic Makeup/Breakout

N/A

Make/Type
Maximum line pull
D.2.18

Rotary Rig Tongs

Quantity (sets)
Make/Type
Range size (max OD/min OD)
Torque rating

2
BJ SDD
4'' TO 9-5/8''
100,000 FT-- LB

D.2.19

N/A

Tubing Tongs (manual)

Quantity (sets)
Make/type
Size range (max OD/min OD)
Torque rating
Quantity (sets)
Make/type
Size range (max OD/min OD)
Torque rating
D.2.20

Tubing Tongs (power)

N/A

Quantity
Make/type
Size range (max OD/min OD)
Max output torque
Torque indicator
Back-up arm
D.2.21

Iron Roughneck

Make/type
Size range (max OD/min OD)

Varco -TW -60


4'' TO 8-1/2''

Max. makeup torque


Max. breakout torque

63,000 FT LBS
75,000 FT LBS

D.3
D.3.1

FISHING EQUIPMENT
Overshots

Quantity
Make/Type
Overshot OD
To catch size
To catch size
To catch size
Overshot guide OD
Extension sub length
Lipped guide (oversize, regular)
Grapples (spiral, basket, both)
Pack offs
Top sub connection type

NA

Yes/no:

Quantity
Make/Type
Overshot OD
To catch size
To catch size
To catch size
Overshot guide OD
Extension sub length
Lipped guide (oversize, regular)
Grapples (spiral, basket, both)
Page 28 of 61
Revised: 30/05/15

Teras Titanium

Pack offs
Top sub connection type
D.3.2

Yes/no:

Hydraulic Fishing Jar

N/A

Quantity
Make/Type
OD body
Min. ID
Stroke
Connection type
Repair kit

Yes/no:

Quantity
Make/Type
OD body
Min. ID
Stroke
Connection type
Repair kit

Yes/no:

Quantity
Make/Type
OD body
Min. ID
Stroke
Connection type
Repair kit

Yes/no:

D.3.3 Jar Intensifier

N/A

Quantity
Make
Type
OD body
Min. ID
Connection type
Repair Kit

Yes/no:

Quantity
Make
Type
OD body
Min. ID
Connection type
Repair Kit

Yes/no:

D.3.4

Surface Jar

Quantity
Make/Type
OD body
Stroke
Connection type
Repair Kit
D.3.5

N/A

Yes/no:

Fishing Bumper Subs

N/A

Quantity
Make/Type
OD body
Min. ID
Stroke
Connection type
Quantity
Make/Type
OD body
Min. ID
Stroke
Connection type

Page 29 of 61
Revised: 30/05/15

Teras Titanium

D.3.6

Safety Joints

N/A

Quantity
Make/Type
OD body
Min. ID
Connection type
Quantity
Make/Type
OD body
Min. ID
Connection type
D.3.7

Junk Baskets (Reverse Circulation) RCJB

N/A

Quantity
Make/Type
For hole size
OD body
Connection type
Inside magnet available
Mill shoes type (A, B, C)

Yes/no:
Yes/no:

Quantity
Make/Type
For hole size
OD body
Connection type
Inside magnet available
Mill shoes type (A, B, C)

Yes/no:
Yes/no:

Quantity
Make/Type
For hole size
OD body
Connection type
Inside magnet available
Mill shoes type (A, B, C)

Yes/no:
Yes/no:

D.3.8

Junk Subs

N/A

Quantity
Make/Type
For hole size
OD body
Connections type
Quantity
Make/Type
For hole size
OD body
Connections type
Quantity
Make/Type
For hole size
OD body
Connections type
D.3.9

Flat Bottom Junk Mill

N/A

Quantity
Make/Type
OD flat mill
Connection type
Quantity
Make/Type
OD flat mill
Connection type
Quantity
Make/Type
Page 30 of 61
Revised: 30/05/15

Teras Titanium

OD flat mill
Connection type
D.3.10

Magnet Fishing Tools

Quantity
Make/Type
OD body
Connection type
Quantity
Make/Type
OD body
Connection type
D.3.11

Taper Taps

N/A

Quantity
Make
Tap OD (max/min)
OD body
Length overall
Connection type
Quantity
Make
Tap OD (max/min)
OD body
Length overall
Connection type
D.3.12

Die Collars

N/A

Quantity
Make
Minimum OD
Maximum OD
OD body
Length
Connection type
Quantity
Make
Minimum OD
Maximum OD
OD body
Length
Connection type
E.
E.1

WELL CONTROL
DIVERTER
NA

Fixed

Annular

Bottom Connection
E.1.1

DIVERTER FLOW LINES

Quantity

Three (3) , One Flow line and Two


Overboard line
12"

Nominal size of flow lines


Running from diverter to
Valve make/type

Hydraulic
Trunnion ball valve
ANSI 900
Page 31 of 61

Revised: 30/05/15

Teras Titanium

Valve make/type
System pressure rating
Flex hose in flow line

2000 psi

E.2 LOW PRESSURE BLOWOUT


PREVENTERS (21-1/4)

N/A

All appropriate components H2S rated


E.2.1

Yes/no:

Ram Type Preventers

Quantity
Make/model
Type (single/double/triple)
Size
Working Pressure
Ram locks
Type (manual/hydraulic)
HS2 service
Side outlets

NA

Yes/no:

Bottom connection
Top connection
Shear ram boosters
Quantity
Make/model
Type (single/double/triple)
Size
Working Pressure
Ram locks
Type (manual/hydraulic)
HS2 service
Side outlets

NA

Yes/no:

Bottom connection
Top connection
Shear ram boosters
E.2.2

Available Rams (installed & spare)

Quantity/type/size
Quantity/type/size
Quantity/type/size
Quantity/type/size
Quantity/type/size
Quantity/type/size
Quantity/type/size

NA
NA
NA
NA
NA

E.2.3

N/A

BOP Ram Configuration (normal)

Upper
Middle Upper
Middle Lower
Lower
E.2.4

Annular Preventer

Quantity
Make/Type
Size
Working pressure
Bottom connection

N/A

Top connection

Page 32 of 61
Revised: 30/05/15

Teras Titanium

E.2.5

Kill Line Valves

N/A

Quantity
Make/Type
Size
Working pressure
Gasket type
Hydraulic/manual/non-return
Quantity
Make/Type
Size
Working pressure
Gasket type
Hydraulic/manual/non-return
Quantity
Make/Type
Size
Working pressure
Gasket type
Hydraulic/manual/non-return
E.2.6 Choke Line Valves

N/A

Quantity
Make/type
Size
Working pressure
Gasket type
Hydraulic/manual
Quantity
Make/type
Size
Working pressure
Gasket type
Hydraulic/manual
E.3

High Pressure Blowout (13-5/8 10,000 PSI)

All appropriate components H2S rated


E.3.1

Yes/no:

Ram Type Preventers

Quantity
Make/model
Type (single/double/triple)
Size
Working pressure
Ram locks
Type (manual/hydraulic)
H2S service
Side Outlets
Size
WP
Bottom connection
Shear ram boosters

Quantity
Make/model
Type (single/double/triple)
Size
Working pressure
Ram locks
Type (manual/hydraulic)
H2S service
Side Outlets
Size
WP
Bottom connection
Shear ram boosters

Yes/no:
Yes/no:

Yes/no:

Yes/no:
Yes/no:

Yes/no:

Page 33 of 61
Revised: 30/05/15

Yes

1
Cameron Type U
Single
13-5/8''
10,000 psi
Yes
Hyd
Yes
2
4-1/16''
10,000 psi
13-5/8'' 10,000 psi Flanged BX-159
Yes

1
Cameron Type U
Double
13-5/8''
10,000 psi
Yes
Hyd
Yes
4
4-1/16''
10,000 psi
13-5/8'' 10,000 psi Flanged BX-159
Yes

Teras Titanium

E.3.2

Available Rams (installed & spare)

Quantity/type/size
Quantity/type/size
Quantity/type/size
Quantity/type/size
Quantity/type/size
Quantity/type/size
Quantity/type/size

3 sets / Drill pipe Rams / 5''


1 set / Variable Rams / 4-1/2'' To 7''
1 set / Variable Rams / 3-1/2'' To 5''
1 set Blind Shear
1 set 2-7/8'' x 5''

Casing Rams
13-5/8
9-5/8
7
E.3.3

01 Set
01 Set
01 Set

BOP Ram Configuration (normal)

Upper
Upper Middle
Middle
Middle Lower
Lower
E.3.4

4-1/2' x 7''
N/A
Blind Shear
N/A
5''

Annual Preventer

Quantity
Make/type
Size
Working pressure
Bottom connection
Top connection
E.3.5

1
Hydril Type GK
13-5/8''
5000 PSI
13-5/8'' 5000 PSI Studded BX - 160
13-5/8'' 10000 PSI Glanded BX - 159

Kill Line Valves

Quantity
Make/type
Size
Working pressure
Gasket type
Hydraulic/manual/non-return
SR #
E.3.6

2
Cameron / Type F Gate valve
2-1/16''
10,000 psi
GY6F7069 / 100304

Choke Line Valves

Quantity
Make/type
Size
Working pressure
Gasket type
Hydraulic/manual
SR #

1
Cameron / Type F Gate valve
4-1/16''
10,000 psi
N/A
Manual
3004011-1-8367

Quantity
Make/type
Size
Working pressure
Gasket type
Hydraulic/manual
SR #

1
Cameron / Type FCC Gate valve
4-1/16''
10,000 psi

E.4.0

N/A

OTHER BLOWOUT PREVENTERS

All appropriate components H2S rated


E.4.1

8004011-2

Yes/no:

Ram Type Preventers

Quantity
Make/model
Type (single/double/triple)
Size
Working pressure
Ram locks
Type (manual/hydraulic)
H2S service
Side outlets

N/A

Yes/no:
Yes/no:
Page 34 of 61

Revised: 30/05/15

Teras Titanium

Bottom connection
Top connection
Shear ram boosters
Quantity
Make/model
Type (single/double/triple)
Size
Working pressure
Ram locks
Type (manual/hydraulic)
H2S service
Side outlets
Bottom connection
Top connection
Shear ram boosters
E.4.2

Yes/no:

Yes/no:
Yes/no:

Yes/no:

Available Rams (installed & spare)

N/A

Quantity/type/size
Quantity/type/size
Quantity/type/size
Quantity/type/size
Quantity/type/size
Quantity/type/size
Quantity/type/size
Quantity/type/size
Quantity/type/size
Quantity/type/size
E.4.3

BOP Ram Configuration (normal)

N/A

Upper
Upper Middle
Middle
Middle Lower
Lower
E.4.4

Annular Preventer

N/A

Quantity
Make/type
Size
Working pressure
Bottom connection
Top connection
E.4.5

Kill Line Valves

N/A

Quantity
Make/type
Size
Working pressure
Gasket type
Hydraulic/manual/non-return
Quantity
Make/type
Size
Working pressure
Gasket type
Hydraulic/manual/non-return
Quantity
Make/type
Size
Working pressure
Gasket type
Hydraulic/manual/non-return

Page 35 of 61
Revised: 30/05/15

Teras Titanium

E.4.6

Choke Line Valves

N/A

Quantity
Make/type
Size
Working pressure
Gasket type
Hydraulic/manual
Quantity
Make/type
Size
Working pressure
Gasket type
Hydraulic/manual
E.5

BOP CONTROL SYSTEM

E.5.1

Accumulator Unit

Make/model
SR #
Location
Fluid reservoir capacity
Oil/water mix. rate
Glycol reservoir capacity
Total accumulator capacity (w/o precharge)
System working pressure
Control manifold model
SR #
Regulator type
Total useful accumulator volume
Total nominal bottles capacity
Bottle working pressure

Koomey, Model T 20180-35, Type 80


12458
U.S. gal

280 USG

U.S. gal
3,000 psi
Koomey, Model SU2KB55 "S" Series
Manifold
GU2KB6S
U.S. gal

11 USG per Bottle , Total 18 Bottles


Yes/no:

Plus percent additional volume


E.5.2

Accumulator Hydraulic Pumps

Electric Driven

Triplex Model 20-315-20-3


with 20 hp motor

Air Driven

Three (3)
Koomey Model 25A Air Pump

E.5.3

Primary Control Panel

Control panel make/model

Location
Panel controls for the following functions:
Annular
Rams Top
Blind / Shear
Rams Bottom
Choke Line HCR
Kill line HCR
Jacks or spare HCR
Diverter System

Rig Floor
Yes/no:
Yes/no:
Yes/no:
Yes/no:
Yes/no:
Yes/no:
Yes/no:
Yes/no:
Yes/no:
Yes/no:
Yes/no:
Yes/no:

E.5.4

Remote Control Panels

Make/model

One (1) Koomey , Model Arc-5 Auxiliary


Air Remote Control Panel

Location

Rig Floor
Page 36 of 61

Revised: 30/05/15

Teras Titanium

Location
Location
Ability to operate main closing unit

Port side Main Deck


Yes/no:

Yes

System routing (direct or through panel)


Remote control of - system pressure

Yes/no:

Yes

Remote control of - annular pressure

Yes/no:

Yes

E.6

CHOKE MANIFOLD
Yes

All appropriate components H2S rated

Yes/no

E.6.1 Choke Manifold


Nominal size
Minimum ID
Maximum W P
Quantity of fixed chokes
Quantity of adjustable chokes
Quantity of power chokes
Power choke remote control panel
Glycol injection
E.7

Quantity
Make/Type
ID
Working pressure
H2S service

Quantity
Make/Type
ID
Working pressure
Fire resistant

E.9.1

Yes/no:

1
Flexible Choke Line
3-1/16''
15,000 psi
Yes

Yes/no:

1
Flexible Kill Line
3-1/16''
15,000 psi
Yes

Yes/no:

One (2)
Fleximak
1-1/2
5000 psi
Yes

Yes/no:

12
Phoenix Beattie / Fireshield 5000 hose
1''
5000 psi
Yes

BOP TESTING EQUIPMENT

N/A

Hydraulic BOP Test Pump

Make/model
Type
Pressure rating
Chart recorder
E.9.2

Yes/no:
Yes/no:

FLEXIBLE BOP CONTROL HOSES

Quantity
Make/Type
ID
Working pressure
Fire resistant

E.9

15,000 psi
1 Cameron
02no
01no

FLEXIBLE CHOKE & KILL LINES

Quantity
Make/Type
ID
Working pressure
H2S service

E.8

Size 2-1/16

Yes/no:

BOP Test Stump

Size
Size
Size
E.10
E.10.1

13- 5/8''

BOP HANDLING
BOP Hoist System

Make/type
Quantity of hoists

JD Neuhaus
2
Page 37 of 61

Revised: 30/05/15

Kerr Test Pump, Model KB3500


Plunger Pump
10,000 psi
Yes

Teras Titanium

Number of lift points on BOP


System safe working load (max BOP wt)

2
37.5 Ton

E.10.2

YES

Work Platforms

BOP work platform (adjustable/fixed/none)


Conductor pipe platform
E.10.3

Yes/no:

Conductor Pipe Tensioning System

N/A

Make/type
Tension capacity
number of lift points
Stroke
F.
F.1

MUD SYSTEM/BULK SYSTEM


HIGH PRESSURE MUD SYSTEM

System working pressure


System test pressure

5000 psi
5000 psi

F.1.1 Mud Pumps


Quantity
Make
Model
Type (Triplex/Duplex)
Mud pump drive motors/pump

Three (3)
National
12-P-160 w/ High Pressure Fluid ends
Triplex
Two (2) GE 752 Shunt wound Motor

SR # 7502931, 7490982, 7491357,


7533591, 7502902 & A-S10243.
Fluid end type
Pump stroke counter type
Supercharging pump type

Proximity Switch
Mission Magnum 6" x 8" x 14", 50 hp
TEFC motor, 1200 rpm
SR # M40782, M67196

Discharge/suction line ID
Mud Pump pulsation dampener type

5'' / 10''
Hydril K20- 5000, Model 100 with 5,000 psi W
P

Reset relief valve


Working flowrate per pump at 90% of max spm
5"
liners @ 0.0656 bbls
5-1/2" liners @ 0.0793 bbls
6"
liners @ 0.0944 bbls
6-1/2" liners @ 0.1108 bbls
7"
liners @ 0.1285 bbls
Quantity
Make
Model
Type (Triplex/Duplex)
Mud pump drive motors/pump
Fluid end type
Pump stroke counter type
Supercharging pump type
Discharge/suction line ID
Mud Pump pulsation dampener type
Reset relief valve
Working flowrate per pump at 90% of max spm

Retsco / 32400/ m2 2000--7500 psi

F.1.2

Transfer Pumps/Mixing Pumps

7.08 BPM
8.56 BPM
10.20 BPM
11.90 BPM
13.90 BPM

1.4.6.3

Mixing Pumps

Two (2)
Mission Magnum, Size 6" x 8" x 14"
480 VAC, 1100 rpm, 3 phase and 75 hp
TEFC motor

Driven by

GPM up to 3000

Page 38 of 61
Revised: 30/05/15

Teras Titanium

Transfer Pumps

Two (2) ,,SR #


Mission Magnum, Size 6" x 8"
One (1) - 75 hp, 1750 rpm TEFC motor
One (1) - 100 hp 1200 rpm motor

Driven by :

F.1.3

Booster Pump

Quantity
Make/type
Capacity (each)
Driven motor type
Drill Water Pump = 02no & Fire Pump = 01no
F.1.4

3
Mission Magnum 6'' X 8'' X 12
480 VAC, 50 HP
AC

Standpipe Manifold

Quantity of standpipes
Standpipe/ID
H-Type standpipe manifold
Kill line outlet
Fill-up line outlet
Bleed-off line outlet

2
Yes/no:
Yes/no:
Yes/no:
Yes/no:

Yes
Yes
Yes
Yes

Quantity
Make/Type
ID x length
Working pressure
Snubbing lines

Yes/no:

2
Copper state Class D
3-1/2'' X 75 FT.
7500 PSI
Yes

Quantity
Make/Type
ID x length
Working pressure
Snubbing lines

Yes/no:

F.1.5

F.1.6

Rotary Hoses

Cementing Hose

Quantity
Type (armor sheath/flexible steel pipe)
Length
ID
Working pressure

1
FLEXIBLE
65 FT
5''
150 psi

Quantity
Type (armor sheath/flexible steel pipe)
Length
ID
Working pressure
F.1.7

High Pressure Flexible Steel Pipe

Make/type
Integral connections/fittings (non-threaded)
ID
Working pressure
Section length

N/A
Yes/no:

Section length
Sweep swivels, make/type
Suitable for H2S service
F.2
F.2.1

LOW PRESSURE MUD SYSTEM


Mud Processing Tank

Sand trap tank, usable volume


Degasser tank, usable volume
Yes/no:
Desander tank, usable volume
Yes/no:
Desilter tank, usable volume
Page 39 of 61
Revised: 30/05/15

176 bbls
72 bbls
NO
72 bbls
NO
72 bbls

Teras Titanium

Yes/no:
Mud cleaner tank, usable volume
Yes/no:
Centrifuge tank, usable volume
Yes/no:

No
72 bbls
No
72 bbls
No

Other tank, usable volume


Yes/no:
Total usable capacity
F.2.2

176 bbls

Mud Tanks

Quantity
Total capacity (usable)
Usable capacity No. 1

Three (3)
1403.5 bbls
425.5 bbls

Height
Mixer
Mud guns
Usable capacity No. 2

Yes/no:
Yes/no:

10 ft
Yes
No
489 bbls

Height
Mixer
Mud guns
Usable capacity No. 3

Yes/no:
Yes/no:

10 ft
Yes
NO
489 bbls

F.2.3

Pill/Slug Tank

Capacity (usable)
Mud agitator
Mud guns

Yes/no:
Yes/no:

Capacity (usable)
Mud agitator
Mud guns

Yes/no:
Yes/no:

F.2.4

Trip/Stripping Tanks

Capacity (usable)
Capacity/foot
Level indicator
Electric pump make
Facility for casing fill-up
Alarm and strip chart recorder
F.2.5

63.5 bbls
No
No

40 bbls
Yes/no:

Yes
Hallco 2500 Supreme

Yes/no:
Yes/no:

Yes
No

Chemical Mixing Tank

Capacity (Usable)
Chemical mixer type
F.2.6

Shale Shakers

Primary

Three (3)
Derrick
GPM up to 3400
Noise level : 75 DB @ 3 meters / 80 DB
@ 1 meter

Driven by :

Eight (8) Martin Engineering 70 CDX 188340-VM, TENV Class 1, Group C & D, Three
phase induction motor

F.2.7

Desander

Quantity
Make/Model
Type
Nominal flow rate
Number of cones

One (1)
Derrick, Model 1-HI-G
Derrick,
Three (3) 10" Cones

Page 40 of 61
Revised: 30/05/15

Teras Titanium

Feed pump make/model


Is pump dedicated to desander
F.2.8

Mission Magnum 6" x 8" x 14" w/ 100 hp


motor
Yes/no:

Yes

Desilter

Quantity
Make/model
Type
Nominal flow rate
Number of cones

One (1)
Derrick
Derrick
N/A
Twenty (20) 4" Cones

Feed pump make/model

Mission Magnum 6" x 8" x 14" w/ 100 hp


motor

Is pump dedicated to desilter


F.2.9

Mud Cleaner

Quantity
Make/model
Type
Nominal flow rate
Number of cones

1
Derrick
1000 GPM
N/A

Feed pump make/model


F.2.10

Mud/Gas Separator (Poor Boy)

Make/Type
Dimensions (height x OD)
Gas discharge line ID
Gas discharge location, primary
Can discharge be tied into burner system
Vacuum breaker
Mud seal height
Pressured gauge
Calculated gas throughput

Yes/no:
Yes/no:
Yes/no:

Velath Engineering Work


45 ft
6''
Top of Derrick
N/A
No
N/A
Yes
N/A

F.2.11 Degasser
Make/Type
Nominal flow rate
Feed pump make/model
F.2.12

Yes/no:

Mud Agitators

Quantity
Make/Model
Driven by motor of power
Located in tanks

Three (3)
Derrick KF97 AM256
15 hp / 480 Volts
Bottom Port on each tank

Quantity
Make/Model
Motor of power
Impeller Speed

Three (3)
GN Solids Control / GNJBQ150A
20HP (15kw)
60/72 rpm

F.2.13

N/A

Mud Centrifuge

Quantity
Make/Model
Feed pump make
Is feed pump dedicated to centrifuge (s)
F.2.13

Yes/no:

Mud Laboratory and Facilities

Separate room

Yes/no:

Yes

Equipped with
Air conditioning
Positive pressure

Yes/no:
Yes/no:

Elect. Phone. Water


Yes
Yes

Page 41 of 61
Revised: 30/05/15

Derrick Vacu - Flo, Model 10310-00


N/A
N/A

Teras Titanium

F.3
F.3.1

BULK SYSTEM
Barite/Bentonite Silos

Quantity
Capacity of each silo
Locations
Type weight loadcell
Pressure rating
Relief valve(s) installed
F.3.2

Surge Tank for Barite/Bentonite

Quantity
Capacity of each tank
Type weight loadcell
Pressure rating
Relief valve(s) installed
F.3.4

Yes/no:

4 Tanks
1268 cu. Ft
STB Side
N/A
42 PSI
Yes

Cement Silos

Quantity
Capacity of each silo
Locations
Type weight loadcell
Pressure rating
Relief valve(s) installed
F.3.3

Yes/no:

4 Tanks
1268 cu. Ft
Port Side
N/A
42 PSI
Yes

N/A

Yes/no:

Mud Hopper

Quantity
Make/model

Feed pump make/model


Is feed pump dedicated to mud hopper(s)
F.3.5

Three (3)
One (1) Crester located in Chemical room and
Two (2) 6 ft Mission High Shear Venturi

Yes/no:

Surge Tank for Cement

N/A

Quantity
Capacity of each tank
Type weight loadcell
Pressure rating
Relief valve(s) installed
F.3.6

Yes/no:

Bulk Transfer System

Port Take on lines

Independent air system for the silos and surge

Rig air
Yes/no:
Yes/no:

Yes

Air reduced from main air supply through


Separate volume tank and drier

Yes/no:

Yes

G.

CASING/CEMENTING EQUIPMENT

N/A

G.1

CASING EQUIPMENT

N/A

G.1.1

Drive Hammer

N/A

Make/type
Maximum casing/conductor OD
G.1.2

API Casing Drifts

N/A

For Casing OD, weight, quantity


For Casing OD, weight, quantity
For Casing OD, weight, quantity
For Casing OD, weight, quantity
For Casing OD, weight, quantity
For Casing OD, weight, quantity
Page 42 of 61
Revised: 30/05/15

Teras Titanium

G.1.3

Clamp-On Type Casing Protectors

N/A

For casing OD, quantity


For casing OD, quantity
For casing OD, quantity
For casing OD, quantity
For casing OD, quantity
For casing OD, quantity
G.1.4

Side Door Casing Elevator

Quantity
For OD casing
Make/Type
Capacity

Quantity
For OD casing
Make/Type
Capacity
Quantity
For OD casing
Make/Type
Capacity
G.1.5

Single Joint Elevators

Quantity
For OD casing
Make/Type

2
5
Varco

Quantity
For OD casing
Make/Type
Quantity
For OD casing
Make/Type
Quantity
For OD casing
Make/Type
Quantity
For OD casing
Make/Type
Quantity
For OD casing
Make/Type
G.1.6

Slip Type Elevator/Spiders

Quantity
Make/Type
Pneumatic/manual
Capacity
Slips for OD casing sizes

Three (3)
Varco
Manual
350 Ton
13-3/8

Quantity
Make/Type
Pneumatic/manual
Capacity
Slips for OD casing sizes
Quantity
Make/Type
Pneumatic/manual
Capacity
Slips for OD casing sizes
Page 43 of 61
Revised: 30/05/15

Teras Titanium

G.1.7

Casing Slips

Quantity
Make/Type
For OD casing
Quantity
Make/Type
For OD casing
Quantity
Make/Type
For OD casing
Quantity
Make/Type
For OD casing
G.1.8

Casing Bowls

Quantity
Make/Type
For OD casing (max/min)
Quantity
Make/Type
For OD casing (max/min)
Quantity
Make/Type
For OD casing (max/min)
G.1.9

Manual Casing Tongs

Quantity (sets)
Make/Type
W /jaws for OD casing (max/min)
Quantity (sets)
Make/Type
W /jaws for OD casing (max/min)
Quantity (sets)
Make/Type
W /jaws for OD casing (max/min)
G.1.10

Power Casing Tongs

Quantity
Make/Type
W /jaws for OD casing (maximum/minimum)
Max output torque
Torque indicator
Back-up arm

Yes/no:
Yes/no:

Quantity
Make/Type
W /jaws for OD casing (maximum/minimum)
Max output torque
Torque indicator
Back-up arm

Yes/no:
Yes/no:

G.1.11 Power Unit For Casing & Tubing Tongs


Quantity
Make/type
Capacity (ea)
Output pressure
Dedicated unit
G.1.12

N/A

Yes/no:

Casing Circulating Head (Swedge)

N/A

For OD casing
Type of connection
Page 44 of 61
Revised: 30/05/15

Teras Titanium

For OD casing
Type of connection
For OD casing
Type of connection
For OD casing
Type of connection
For OD casing
Type of connection
For OD casing
Type of connection
G.1.13

Casing Spears (International)

Quantity
Make/Type
For OD casing
For casing weight
Pack-off

N/A

Yes/no:

Quantity
Make/Type
For OD casing
For casing weight
Pack-off

Yes/no:

Quantity
Make/Type
For OD casing
For casing weight
Pack-off

Yes/no:

G.1.14

Casing Cutters (Internal)

N/A

Quantity
Make/Type
For OD casing (max/min)
Quantity
Make/Type
For OD casing (max/min)
Quantity
Make/Type
For OD casing (max/min)
G.1.15

Crossover to Handle Casing with

N/A

Quantity
For OD casing
Casing connection type
Drill pipe connection type
Rated capacity
Quantity
For OD casing
Casing connection type
Drill pipe connection type
Rated capacity
Quantity
For OD casing
Casing connection type
Drill pipe connection type
Rated capacity

Page 45 of 61
Revised: 30/05/15

Teras Titanium

G.1.16

Casing Scrapers

N/A

Quantity
Make
For OD casing
For casing weight
OD body
Connection type
Blade type (roller/fixed)
Quantity
Make
For OD casing
For casing weight
OD body
Connection type
Blade type (roller/fixed)
Quantity
Make
For OD casing
For casing weight
OD body
Connection type
Blade type (roller/fixed)
Quantity
Make
For OD casing
For casing weight
OD body
Connection type
Blade type (roller/fixed)
G.2

CEMENTING EQUIPMENT

G.2.1

Cement Unit

Owner
Free placement basis
Make/Type
No. of triplex pumps
Maximum working pressure
Maximum flowrate (total)
Unit powered by (electric or diesel)
Recirculating mixing system

NA
Yes/no:

Yes/no:

Liquid additive system


Premix/batch tank

Yes/no:
Yes/no:

Pressure recorder
Desionmeter recording device

Yes/no:
Yes/no:

G.2.2

Cementing Manifold

Discharge manifold working pressure


Cement pump discharge lines min. ID
Cement pump disc. Lines working pressure
Manifold safety pressure relief valve
G.2.3

Yes/no:

Cementing Standpipe

Quantity
Working pressure
ID
Connection to choke manifold
Connection to standpipe manifold
G.2.4

N/A

1
5000 PSI
Yes/no:
Yes/no:

Cementing Kelly

N/A

Quantity
Nominal size OD
Total length
Page 46 of 61
Revised: 30/05/15

Yes
Yes

Teras Titanium

Working length
Connection type
Cement head
G.2.5

Yes/no:

Cementing Tubing

N/A

Size
Length
X-overs to drillpipe specified in Section D.1.3.
H.
H.1

Yes/no:

INSTRUMENTATION/COMMUNICATION

N/A

DRILLING INSTRUMENTATION AT DRILLERS POSIT

H.1.1

ION

Weight Indicator

Make/Type
Sensor type
H.1.2

N/A

Martin Decker/Analog
Pancake

Standpipe Pressure Gauges

Quantity
Make/Type
Maximum Pressure reading

One(1)
Martin Decker/Analog
5000psi

Quantity
Make/Type
Maximum Pressure reading

One(1)
MD TOTCO
5000

H.1.3

Choke Manifold Pressure Gauge

Quantity
Make/Type
Maximum pressure reading

Two(2)
Martin Decker
10K

Quantity
Make/Type
Maximum pressure reading

One(1)
Durant/Digital
10,000psi

H.1.4

Rotary Instrumentation

H.1.4.1

Tachometer

Make/type
Maximum RPM
H.1.4.2

Torque Indicator

Make/Type
Maximum torque
H.1.5
H.1.5.1

Top Drive Instrumentation


Tachometer

Make/type
Maximum RPM
H.1.5.2

NOV Analog
350RPM

Torque Indicator

Make/Type
Maximum torque
H.1.6

NOV Analog
51(FT/lbs X 1000)

Pump Stroke Counters

Quantity
Make/Type
Stroke indicator and cumulative

One(1)
Durant Digital
Durant Digital
Yes/no:

H.1.7

Tong Torque Indicator

Make/Type
Maximum torque

Varco
16000 ft lbs
Page 47 of 61

Revised: 30/05/15

Teras Titanium

H.1.8

Pit Volume Totalizer

Make/Model
Floats in active mud tanks

Yes/no:

MD TOTCO
Yes

Floats in reserve mud tanks

Yes/no:

Yes

Loss/Gain indicator

Yes/no:

Yes

H.1.9

Mud Flow Indicator

Make/Model

MD TOTCO

High/low alarm
Yes/no:
Yes/no:
Sensor location
H.1.10

Trip Tank Indicator

Make/Model
Chart recorder
Alarm

Yes/no:
Yes/no:

Make/Model
Chart recorder
Alarm

Yes/no:
Yes/no:

H.1.11

MD TOTCO
Yes
Yes

Automatic Driller (see B.2.1)

Make/Type
H.1.12

Yes
Yes
Flow Line

NOV / Wild Cat Services

Remote Choke Control Unit (see E.5)

H.1.13 Crown Clearance Indicator


Make/type
H.2

Crown -O-matic

DRILLING PARAMETER RECORDER

Quantity
Make/Type
Location 1
Location 2
Location 3

Three(3)
MD TOTCO
Drillers Shack
OIM office
Co. Man Office

Number of parameters recorded


Parameter recorded
Parameter recorded
Parameter recorded
Parameter recorded
Parameter recorded
Parameter recorded
Parameter recorded
Parameter recorded

Stand Pipe
Casing Pressure
Strokes
Trip Tank
Pit Levels
Flow
Total Strokes
Ton miles

H.3

INSTRUMENTATION AT CHOKE MANIFOLD

H.3.1 Standpipe Pressure Gauge


(Drillpipe pressure gauge)
Quantity
Make/Type
Pressure range (maximum)
Visible from choke operating position

Yes/no:

H.3.2 Choke Manifold Pressure Gauge


(Casing pressure gauge)
Quantity
Make/Type
Pressure range
Visible from choke operating position

Yes/no:
Page 48 of 61

Revised: 30/05/15

Teras Titanium

H.4
H.4.1

INSTRUMENTATION AT STANDPIPE
STANDPIPE PRESSURE GAUGE

Quantity
Make/Type
Pressure range
Visible from drillers position
Visible from choke operating system
H.5
H.5.1

DEVIATION EQUIPMENT
Deviation Recorder

Quantity
Make/Type
Deviation range

degree/degree:

Quantity
Make/Type
Deviation range

degree/degree:

H.5.2

Slickline Unit (see B.2.4)

H.6

RIG COMMUNICATION SYSTEMS

H.6.1

Rig Telephone System

No. of stations
Make/Type
Explosion proof
H.6.2

Public Address System

Can be combined with H.6.1 above


No. of stations
Make/Type
Explosion proof
H.6.3

Yes/no:

Twenty-three (23)
Gia-Tronic PA / GA System
Yes

Yes/no:
Yes/no:

Yes
Twenty Three(23)
Gia-Tronic PA / GA System
Yes

Drill Floor Talkback System

No. of stations
Location
Location
H.6.4

Hand-Held VHF Radios

Quantity
Quantity intrinsically safe
H.6.5

Six (6) , Icom


Yes

Crane Communication System

Quantity
Make/type
Explosion proof
Part of rig telephone system (H.6.1)
Part of public address system (H.6.2)

Yes/no:
Yes/no:
Yes/no:

One
Gaitronics PA/GA System
Yes
Yes
Yes

Recorder
Sea water temperature (make/model)
Recorder

Yes/no:

No

Yes/no:

No

H.7.2

Yes/no:

H.7

ENVIRONMENTAL INSTRUMENTATION

H.7.1 Temperature Indicators


Air temperature (make/model)

Barometric Pressure Indicators

Make/Model
Recorder

Yes/no:
Page 49 of 61

Revised: 30/05/15

No

Teras Titanium

H.7.3

Humidity Sensing Indicator

Yes/no:

Make/Model
Recorder

Yes/no:

H.7.4

Yes/no:

Wind Speed/Direction Meter

No

Make/Model
Recorder

Yes/no:

No

H.7.5

Yes/no:

N/A

Wave Profile Recorder

Make/Model
Recorder
H.7.6

Current Indicator

Make/model
Located at
Recorder
H.7.7

H.8.1

N/A

Yes/no:

Weather Facsimile

Make/model
Located at
Recorder
H.8

Yes/no:

N/A

Yes/no:

NAVIGATION INSTRUMENTATION
Gyro Compass

Make/model

One (1) W EEMS and PLATH Hand held


Compass

Located at
H.8.2

Depth Sounder

N/A

Make/model
Located at
Recorder
H.8.3

Radar

N/A

Quantity
Make/model
Located at
Bandwidth
H.9
H.9.1

EXTERNAL COMMUNICATIONS EQUIPMENT


SSB Transceiver

Location(s)
Quantity
Make/Model
Power
Frequency ranges (low/high)
(Synthesized crystal)
Facsimile capable (see also H.9.9)
Telex capable (see also H.9.10)
Location(s)
Quantity
Make/Model
Power
Frequency ranges (low/high)
(Synthesized crystal)
Facsimile capable (see also H.9.9)
Telex capable (see also H.9.10)

Yes/no:
Yes/no:

Radio Room
1
Sailor, Model CU5100 / TU5250
250w
High
Synthesized
No
Yes

Yes/no:
Yes/no:

Tour Pusher Office


1
Sailor, Model CU5100 / TU5250
250w
High
Synthesized
No
Yes

Page 50 of 61
Revised: 30/05/15

Teras Titanium

H.9.2

E.P.I.R.Bs

Quantity
Make/Model
Locations(s)

One(1)
Jotron/ TRON 40S
Control Room Deck

Quantity
Make/Model
Locations(s)
H.9.3

Marine VHF Radio

Quantity
Make/Model

Four(4)
Sailor Model RT5022 / ICOM / IC-M504

Power
Channels
Location

25w
All Marine Channels
Radio Room

Quantity
Make/Model
Power
Channels
Location

One (1)
Sailor Model RT
25w
All Marine Channels
Tour Pusher Office

H.9.4

N/A

Aircraft Radio Beacon Transmitter

Quantity
Make/Model
Power
H.9.5

Aeronautical VHF Transceiver

Quantity
Make/Model
Power
Frequency range (low/high)
(Synthesized/crystal)
Location(s)
H.9.6

Three(3)
ICOM IC A110/IC-A3/IC-A6

Watch Receiver
Sailor DSC W /K Receiver
Four(4)
MF/HF-CU5100 / TU5250 VHF RT5022
MF/HF DSC Freq VHF Ch. 70

Quantity
Make/Model
Frequency
H.9.7

Satellite Communication System

Make/Model
Type
Facsimile capable (see also H.9.9)
Telex capable (see also H.9.10)
Location(s)
H.9.8

Inmarsat C Sailor TT-3000E


Yes/no:
Yes/no:

Cellular

Number of phone lines


H.9.9

Facsimile

Make/model
Connected to
Make/model
Connected to
H.9.10

Telex

Make/model
Connected to
Make/model
Connected to
Page 51 of 61
Revised: 30/05/15

Yes
Radio Room

Teras Titanium

H.9.11

Scrambler

Make/model
Connected to
Make/model
Connected to
H.9.12

Other Communication Systems

Make/model
Connected to

F33/KVH TRACPHONE
Radio Room

Make/model
Connected to
I.
I.1

PRODUCTION TEST EQUIPMENT


BURNERS

N/A

Make/type
Quantity
Capacity
Weight
Water requirement at 100 psi
I.2

BURNER BOOMS

Make/type
Quantity
Length
Horizontal
Maximum wind speed
Walkway and handrails
Burner platform size
Burner mounting rotatable
I.3
I.3.1

Yes/no:
Yes/no:
N/A

Oil Line

Yes/no:

Gas Line

ID
Working pressure
Extended beyond burner by
Connection type at burner end
H2S
Pressure gauge connection at barge end
I.3.3

Yes/no:

PIPING ON BURNER BOOMS

ID
Working pressure
Connection type at burner end
H2S
Pressure gauge connection at barge end
I.3.2

N/A

N/A

Yes/no:

Water Line

N/A

ID
Working pressure
Connection type at burner end
Pressure gauge connection at barge end
I.3.4

Air Line

N/A

ID
Working pressure
Connection type at burner end
Pressure gauge connection at barge end
I.3.5

Pilot Gas line

N/A

ID
Working pressure
Connection type at burner end
Page 52 of 61
Revised: 30/05/15

Teras Titanium

Pressure gauge connection at rig end


I.4

SPRINKLER SYSTEM

System in place
Pump source
I.5
I.5.1

Yes/no:

FIXED PIPING FOR WELL TESTING

N/A

Drill floor To Separator Area

Type (threaded/welded/both)
Quantity
Size ID
Working pressure
Connection on drill floor
Connection at separator
Number of valves/lines
Size of valves
H2S
I.5.2

N/A

N/A

Yes/no:

Separator Area to Burner Booms

N/A

Service (oil/gas)
Type (threaded/welded/both)
Quantity
Size ID
Working pressure
Connection at separator
Connection at boom
Number of valves/lines
Size of valves
H2S
Valves installed near separator area for
switching gas to either burner
Service (oil/gas)
Type (threaded/welded/both)
Quantity
Size ID
Working pressure
Connection at separator
Connection at boom
Number of valves/lines
Size of valves
H2S
Valves installed near separator area for
switching gas to either burner
I.5.3

Yes/no:
Yes/no:

Yes/no:
Yes/no:

Water Lines To Burner Booms

N/A

Type (threaded/welded/both)
Quantity
Size ID
Working pressure
Number of valves required
Size of valves
Pump source
Rated line capacity at 300 psi
I.5.4

Air System To Burners Rooms

Type (threaded/welded/both)
Quantity
Size ID
Working pressure
Non-return valves fitted
Air source
I.5.5

N/A

Yes/no:

Oil Storage Tank To Overboard

N/A

Type (threaded/welded/both)
Quantity
Page 53 of 61
Revised: 30/05/15

Teras Titanium

Size ID
Working pressure
Connection at separator area
I.5.6

Separator To Vent Stack Of Rig

N/A

Type (threaded/welded/both)
Quantity
Size ID
Working pressure
Connection at separator area
I.6
I.6.1

AUXILIARY POWER AVAILABILITY


For Field Laboratory

N/A

Quantity
Volts
Frequency
Breaker
I.6.2

For Crude Transfer Pump

N/A

Quantity
Volts
Frequency
Breaker
I.6.3

For Electric Heaters

N/A

Quantity
Volts
Frequency
Breaker
J.

WORKOVER TOOLS

K.

ACCOMMODATION

K.1

N/A

OFFICES

K.1.1

Company Representatives Office

Quantity
Complete with desk, filing cabinet(s) and
Quantity with unrestricted view to drill floor
K.1.2

One (1)

Contractor Representatives Office

Quantity
Quantity with unrestricted view to drill floor

Yes/no:

K.1.3

Yes/no:

Control room

Two (2)

Quantity

K.1.4

One (1) Includes Radio room, Jacking control


and Main Fire and Gas alarm Panel
Radio room

Quantity
K.1.5

See K.1.3
Helicopter Ready Room

Quantity
K.1.6

Hospital Room

Number of beds/bunks
Dangerous drugs locker

Yes/no:

Page 54 of 61
Revised: 30/05/15

Five (5) Beds


Yes

Teras Titanium

K.2

LIVING QUARTERS

K.2.1 Accommodation for Companys personnel


Total beds
K.2.3

110

Mess Seating Capacity

Main mess

49 each

K.2.4 Meeting Rooms


Quantity
K.2.5

One (1)
Recreation Rooms

Yes

Quantity
Recreation facilities
K.2.6

Other Rooms

Change Rooms
Prayer Rooms
Cinema
Other (GYM)
L.
L.1

1
1
1
1

SAFETY EQUIPMENT
GENERAL SAFETY EQUIPMENT

L.1.1

General Personnel Protective Gear

Safety glasses
Safety hats (contractor/everyone/not supplied)
Safety boots (contractor/everyone/not supplied)
Safety clothing
Ear protection (contractor/everyone/not supplied)
Rubber gloves
Rubber aprons
Rubber gloves - elbow length
Fullface visors
Eye shields (for grinders)
Dust masks
Explosion proof hand torches
Safety belts c/w lines
L.1.2 Decontamination Stations
L.1.2.1

Eye Wash Stations

Quantity - fixed
Make/model
Location(s)

Four (4)
One each in Rig floor, Mud pits, Chemical room
and Shale shaker

Quantity - fixed
Make/model
Location(s)
L.1.2.2

Safety Showers

Quantity
Location(s)

05no
02 Mud Pit, 01 Rig Floor, 01 Shaker & 01
S/Room

Page 55 of 61
Revised: 30/05/15

Teras Titanium

L.1.3

Derrick Safety Equipment

Derrick safety belts


Geronimo line

NA
Yes/no:

Derrick safety belts


L.1.4

Derrick Climbing Assistant

01 Set

Make/Type
L.1.5

Fresh Air Blowers (Bug Blowers)

Quantity
Make/Type
Located at

L.2
L.2.1

12no
05 Engine Room, 03 Mud Pump Room, 01
Shale Shaker, 02 Rig Floor & 01 Derrick

GAS/FIRE/SMOKE DETECTION
H2S Monitoring System

Make/Type
Sampling points at:
Flow line
Rig Floor
Shale Shakers
Mud pit room
Mud pump room

Rexnord Series 740 A Gas monitor w/ a


Model 226123 Controller w/ Four channel
Yes/no:
Yes/no:
Yes/no:
Yes/no:
Yes/no:

Alarms at

Yes
Yes
Yes
Alarm set at 5 PPM (Low level) and 10
PPM (High level

Yes/no:
Central control panel
Local alarm (audible/visual/both)
L.2.2

Both

Combustible Gas Monitoring System

Make/Type

Three (3) Rexnord Series880A Gas monitor


w/ a Model 225474 controller w/
18 Channels

Sampling points at:


Flow line
Rig Floor
Shale Shakers
Mud pit room
Mud pump room

Yes/no:
Yes/no:
Yes/no:
Yes/no:
Yes/no:

Alarms at

YES
YES
YES
YES
YES
Alarm set at 20 % LEL (Low level) and
40 % LEL (High level)

Yes/no:
Central control panel
Local alarm (audible/visual/both)
L.2.3

Both

H2S Detectors (Portable)

Quantity
Make/Type

Six (6)
Industrial Scientific MSA , Model T-40

Stain tubes for H2S: measuring range


L.2.4

Explosimeters

Quantity
Make/Type
Page 56 of 61
Revised: 30/05/15

Teras Titanium

L.2.5

CO2 Gas Detectors (Portable)

Quantity
Make/Type
Stain tubes for CO2: measuring range
L.2.6

O2 Meter (Portable)

Quantity
Make/type
L.2.7 Fire/Smoke Detectors
Make/type
Fire detection
Smoke detection
Central control panel

Yes/no:
Yes/no:
Yes/no:

Pyrotronic System 3
Yes
Yes

Alarms
Pull boxes
L.3
L.3.1

FIRE FIGHTING EQUIPMENT


Fire Pumps

Quantity
Make/Model
Type
Output (each)
Location

One (1)
Peerless, Model 10 lb-4
4 Stage
350 GPM
(Alternative Fire Pump) : Normal use of below
Pumps are Drill Water pumps

Quantity
Make/Model
Type
Output (each)
Location
All off take points supplied by all pumps
L.3.2

Two (2),
Peerless, Model 10 lb
350 GPM
Port P tank room
Yes/no:

Hydrants and Hoses

Eighteen(18)
10 each 1-1/2" Hose station
8 each 2-1/2" Hose station
All stations with 50 ft Hose length

Hydrants positioned such that any point may be


Yes/no:
L.3.3

Portable Fire Extinguishers

Quantity (total)

88 each

Type 1 - CO2
Type 2- Dry chemical
Type 3 - Foam

27 each
57 each
4 each

Water
Halon
L.3.4

Fire Blankets

Quantity
Location(s)
L.3.5

Two (2)

Fixed Foam System

Make/Type
Quantity of foam concentrate stored
Foam type
Application rate
Foam nozzles
Automatically injected into fixed
Yes/no:
Page 57 of 61
Revised: 30/05/15

Teras Titanium

L.3.6

Helideck Foam System

Make/Type

2 each Feecon Foam/water Guns Model


FVB-2-600
1 each Foam/water single wheel Model
8393H
2 each Foam applicators
1 each Foam tank Model SNPH w/
capacity 200 gal
1 each Demco pump Model MX w/ 50 hp
motor delivering 500GPM @ 150 psi

Quantity of monitors
Quantity of foam concentrated stored
Foam type
Application rate

Two (2)
200 gal
AFFF 3%

L.3.7

YES

Fixed Fire Extinguishing System

Protected spaces
Automatic shutdown of ventilation fans

Yes/no:

L.3.8

Yes/no:

Manual Water Deluge System

Protected spaced
Protected spaced
Water supplied from fire main line
L.3.9

Tank capacity
Salt water backup
Type (wet pipe/dry pipe)

L.4.1

Yes/no:

Yes/no:

Yes/no:

BREATHING APPARATUS
General Sets

Quantity
Make
Type (demand/positive pressure)
Cascade system quick connects
Cylinder duration
Located at
Located at
Located at
Located at
Located at
Located at
L.4.2

Rig Floor

Water Sprinkler System

Automatic activation
Working pressure

L.4

Yes/no:

Escape sets

Quantity
Make
Type (demand/positive pressure)
Cascade system quick connect
Cylinder duration

Yes/no:

Located at
L.4.3

Cascade Stations

Quantity
Make/type
Manifold locations/outlets at location
Manifold locations/outlets at location
Manifold locations/outlets at location
Manifold locations/outlets at location
Manifold locations/outlets at location
Page 58 of 61
Revised: 30/05/15

Yes

Yes
40 psi

Teras Titanium

Manifold locations/outlets at location


L.4.4 Breathing Air Recharge Compressor
Quantity
Make/Type
Compressed air storage capacity
Located at
L.4.5

Compressed Air Breathing Apparatus

Make
Type (demand/positive pressure)
Air line length
Compressed air storage capacity
Including
Yes/no:
Yes/no:
Yes/no:
Yes/no:
Yes/no:
L.4.6

Breathing Air Purity Test Equipment

Quantity
Make/Type
L.5
L.5.1

EMERGENCY FIRST AID EQUIPMENT


First Aid Kits

Quantity

L.5.2

Five (5)
2 each in Crash Box, 1 each in Two
Capsules and 1 each in Sick Bay

Burn Kits

Quantity
L.5.3 Resuscitators
Quantity
Charged (spare) oxygen cylinders
L.5.4

Stretchers

Quantity
Type
Located at
Quantity
Type
Located at
L.6

HELIDECK RESCUE EQUIPMENT

YES

L.6.1 Storage Boxes


Quantity
Construction
Max height open
L.6.2 Equipment
Aircraft axe
Large firemans rescue axe
Crowbar 3 ft
Heavy duty hacksaw (with spare blades)
Grapnel hook with 16ft wire rope attached
Quick release knife
Bolt croppers

Yes/no:
Yes/no:
Yes/no:
Yes/no:
Yes/no:
Yes/no:
Yes/no:
Page 59 of 61

Revised: 30/05/15

Teras Titanium

L.7

EMERGENCY WARNING ALARMS

Approved system to give warning of

Activated from drill floor


L.8

SURVIVAL EQUIPMENT

L.8.1 Lifeboats
Make/Type
Quantity
Capacity
Locations (frwd/aft/Port/stbd)
Fire protection

Yes/no:

Yes

Radio/EPIRB (see section H.9)

Yes/no:

NA

Make/Type
Quantity
Capacity
Locations (frwd/aft/Port/stbd)
Fire protection
Radio/EPIRB (see section H.9)

Yes/no:
Yes/no:

L.8.2

Life rafts

Make/type
Quantity
Capacity
Davit launched
Locations (frwd/aft/Port/stbd)
Make/type
Quantity
Capacity
Davit launched
Locations (frwd/aft/Port/stbd)
L.8.3

JIANGYINSHI BEIHAI / JYB75F


Two (2)
55 man each

Yes/no:

BF Goodrich
Four (4)
25 man each
Yes (Alexander Davit Launch)

Yes/no:

Fast Rescue Boat

Make/Type

Narwhal, Model SV - 400 Solas Rescue


Boat

Engine power

40 hp

L.8.4

Personal Flotation Devices

Make/Type

Safeguard West, Model S225RT Life


Jackets

Quantity

162 each

L.8.5

Survival Suits

Make/Type
Quantity
L.8.6 Life Ring Buoys
Make/type
Quantity total

Nine (9)

Make / Type
Quantity
Make / Type
Quantity
L.8.7

Work Vests

Quantity

Ten (10)
Page 60 of 61

Revised: 30/05/15

Teras Titanium

L.8.8

Escape Ladders/Nets

Make/Type
Quantity
Make/Type
Quantity

M.
M.1

POLLUTION PREVENTION EQUIPMENT


SEWAGE TREATMENT

Make/model
System type

OmniPure Model 12-MC

M.2 GARBAGE COMPACTION


Make/model
System type

Dolphin 1787

Make/model
System type

M.3 GARBAGE DISPOSAL/GRINDER


Make/model
System type

Dolphin

M.4 INCINERATOR

N/A

Make/model
System type

M.5 OILY WATER SEPARATOR


Quantity
Make/model
System type
Nominal throughput

1
BOSS 107C
Recovered System
45 GPM

Page 61 of 61