Documente Academic
Documente Profesional
Documente Cultură
clear airborne pollutants and odors from the air so its more
Table of Contents
Certified - Panasonic ventilation fans are certified by
building programs.
steel body.
Easy Installation - Detachable duct adapters, adjustable
mounting brackets (up to 24" o.c.), fan/motor units that
easily detach from the housing and uncomplicated wiring
all lend to user-friendly installation. Select models also
feature double-hanger bar systems allowing for ideal
positioning.
Safety - Equipped with thermal cut-out fuse.
WhisperValue-Lite Super Low Profile Ceiling Mount Fan With Light_ ______________29
prevents backdraft.
Illumination - Compact fluorescent lamps with 10,000
hours of rated life and a 4-Watt night light are available on
select models.
Good
Why is ventilation
necessary?
Ideally, an airtight home designed with both continuous and intermittent ventilation will
contribute to a healthy and comfortable living environment for the entire family.
Airtight Homes
Homes designed and built in recent years
are more airtight and energy efficient than
in the past. To obtain this airtight design,
Continuous Ventilation
Biological Pollutants
smokers as well.
react to them.
air quality.
Bad
Intermittent Ventilation
Sizing
Information and Instructions
Airtight Homes
The first step when sizing for a ventilating
fan is to determine the application. Decide
whether you are sizing for intermittent or
continuous ventilation (see pages 6 and 7).
If intermittent, determine which application,
(i.e. bathroom, kitchen or other). Use the
following industry recommendations to
determine Air Changes per Hour (ACH) for
your specific application.
Intermittent (spot) ventilation:
The Home Ventilating Institute (HVI)
recommends the following Air Changes per
Hour (ACH). (See HVI on page 13)
I. Bathrooms - 8 ACH or 1 CFM/sq ft
II. Kitchens - 15 ACH or 2 CFM/sq ft
III. Other Rooms - 6 ACH or .75 CFM/sq ft
Continuous (whole house)
ventilation:
Most building codes have adopted the
American Society of Heating, Refrigerating,
and Air Conditioning Engineers (ASHRAE)
Standard 62. The most current version,
ASHRAE 62.2-2007, calls for continuous
mechanical ventilation as shown below.
I. House or apartment - 7.5 CFM per
person plus 1 CFM per 100 square feet
The second step is to calculate the area
being ventilated. Calculate square feet
or cubic feet depending on which sizing
method you choose.
No Duct work
No duct equals
zero static pressure
and maximum
air flow.
FIG. A
4"
Smooth Metal
6"
8"
Flex Aluminum
Insulated Flex
Terminal
Wall Cap
30 feet
30 feet
40 feet
40 feet
Device
Roof Jack
30 feet
30 feet
40 feet
40 feet
Elbow
Adjustable
15 feet
15 feet
20 feet
20 feet
Material
FIG. B
4" duct
FV-08VK3
FV-08VQ5
8 ft x 10 ft = 80 sq ft
FV-11VF2
4" duct
FV-11VFL2
4" duct
FV-11VH2
4" duct
FV-11VHL2
4" duct
FV-11VQ5
4" duct
FV-11VQL5
4" duct
4" duct
15 ft + 15 ft + 30 ft = 60 ft EDL
FIG. C
Installation
A practical guide to Panasonic
fan installation
Proper fan installation is necessary to
trusses.
Best
PVC or Galvanized
Better
Aluminum Flex
Poor
Vinyl
resistance.
Elbows: Rule number one is to avoid
Insulation.
4" dryer-hood
type vent with
backdraft flap(s).
optimum airflow.
Duct adapter with junction box is
installed before drywall, (bottom edge
flush with bottom face of drywall).
FIG. F
FIG. D
Correct
Incorrect
10
FIG. G
FIG. E
Preferred
Typical
performance.
Note: If duct is in
the attic, to avoid
possible condensation
problems, be sure it is
either under loose fill
insulation or it is fully
insulated to minimum of
R-5 with duct wrap.
11
Ventilation Controls
12
are protected.
ENERGY STAR
ENERGY STAR
Min.
Max.
Min.
Rated
Specifications
CFMs/Watt
Sones
Warranty
1.4
2.0
1 year
60%
2.8
2.0
1 year
70%
2.8
3.0
1 year
70%
In-Line Fans
2.8
N/A
1 year
N/A
www.energystar.gov
interaction. The ventilation system will
remain on and continue working for
a duration after the occupant has left
the room, much like a delay off timer.
Select WhisperGreen Premier fans
have occupancy sensors integral to the
fan grille. Dehumidistats can be used to
turn a ventilation system on/off when
relative humidity reaches a certain level.
These controls are most likely to be used
in bathrooms to evacuate excessive
moisture. Dehumidistats have a few
disadvantages. One disadvantage
is that seasonal changes in outdoor
relative humidity necessitate seasonal
readjustments to function optimally.
Another disadvantage of a dehumidistat
is that they are often mistaken for
thermostats and set at 70 and never
adjusted. Finally, it does not automatically
remove odors.
Automatic timers: Automatic timers
operate fans at programmed times
throughout the day. Typically a 24-hour
programmable timer is used to run a
fan in morning and evening hours when
there is a high demand for ventilation. For
continuous ventilation, the control can be
programmed to operate throughout the
day to help evacuate any accumulation of
VOCs or other indoor air pollutants.
Controls can also be used in combination
with each other to provide both
intermittent and continuous ventilation.
For example, a programmable timer
may be used to cycle the fan on and
off throughout the day to address
overall indoor air quality. WhisperGreen
Premier fans have been designed as
an ideal double-duty fan providing both
intermittent and continuous ventilation
with a DC motor activated by built-in
speed, delay and occupancy controls.
The key to selecting the right control
or combination of controls is to first
understand the occupants lifestyle and
ventilation needs. Then select a control
that provides proper ventilation with little
or no involvement by the occupant.
particular model.
details.
performance.
Wauconda, IL 60084
Association.
California Title 24
ASHRAE 62.2-2007
ASHRAE 62.2
of air flow.
Green FAQs
0-1 BR
2-3 BR
4-5 BR
6-7 BR
>7 BR
<1500
30
45
60
75
90
1501-3000
45
60
75
90
105
3001-4500
60
75
90
105
120
4501-6000
75
90
105
120
135
6001-7500
90
105
120
135
150
>7500
105
120
135
150
165
15 CFM
Second Bedroom
7.5 CFM
14
Floor area
Total
38.5 CFM
air quality.
can be tolerated.
FAQs
1. What is a sone?
ways:
2. What is CFM?
CFM, or Cubic Feet per Minute is a
measurement of rate of air flow. The
larger the CFM, the more powerful the
fan.
kitchen area.
Motor Production.
Panasonic motor production is
fully automated, with an automatic
defect detecting system. The quality
assurance program is exemplary,
inexpensive fans.
Selective Application.
Fan Housing.
The fan housing is made of heavygauge zinc-galvanized steel and
FIG. I
required to be IC rated?
Tip Speed.
16
Quiet Motor.
ducting.
ceiling?
the sink.
17
Built-in Controls
Single Speed
WhisperGreen Gen 3
Static Pressure in inches w.g.
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.1
0.25
135
0.25
70
75
60
59
50
54
40
39
30
32
130
135
110
111
90
93
70
71
50
53
50
54
80
79
130
<0.3
0.4
<0.3
0.3
<0.3
0.3
<0.3
<0.3
<0.3
<0.3
<0.3
0.7
<0.3
0.6
<0.3
0.6
<0.3
0.4
<0.3
<0.3
<0.3
0.3
<0.3
0.4
<0.3
0.7
Characteristics
7.0
11.0
5.4
10.1
5.0
8.7
4.3
7.5
3.7
6.6
3.2
5.8
11.9
21.5
9.0
15.6
6.2
12.5
4.1
9.8
2.4
5.9
4.3
7.5
7.0
11.0
11.9
21.5
12.1
7.6
13.3
7.7
13.6
7.7
12.4
7.7
12.8
7.1
11.4
6.7
11.2
6.4
12.5
7.3
15.2
7.8
18.7
7.9
23.3
10.0
12.4
7.7
12.1
7.6
11.2
6.4
Speed (RPM)
832
1130
791
1125
773
1106
749
1101
740
1093
745
1087
662
917
643
912
580
900
506
874
430
781
749
1101
832
1130
662
917
0.02
0.01
0.03
0.01
0.05
0.01
0.05
0.02
0.05
0.03
0.06
0.04
0.01
0.12
0.03
0.09
0.02
0.07
0.04
0.01
0.06
0.03
0.05
0.02
0.02
0.01
0.01
0.12
Current (amps)
120/60
120/60
Yes
FV-08VKS3: No,
Yes
FV-08VKM3: Yes
FV-13VKS3: No,
FV-13VKM3: Yes
Single Speed
79
0.4
0.25
FV-13VK3
80
Fits in 2 x 8 construction
0.1
FV-08VK3
<0.3
0.25
FV-05VK3
Noise (sones)
0.1
FV-13VKS3/13VKM3
FV-13VKM3)
FV-08VKS3/08VKM3
Built-in COnrols
120/60
120/60
120/60
Yes
Yes
Yes
No
No
No
No
Yes
Yes
No
No
Yes
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
UL tub/Shower Enclosure
Yes
Yes
Yes
Yes
Yes
Approved Code/Standard/
Yes
Yes
Yes
Yes
Yes
Regulation
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A=not applicable
w.g.=water gauge
S.P.=static pressure
4" duct
6" duct
4" duct
6" duct
FV-08VKM3
18
Panasonic ventilation fans may qualify for an energy saving rebate. Rebate programs are often provided by local utility
companies and based on ENERGY STAR guidelines. Check with your local utility company for details.
FV-13VKM3
FV-05VK3/FV-08VK3/FV-08VKS3
FV-13VK3/FV-13VKS3
19
Built-in Controls
Single Speed
WhisperGreen-Lite Gen 3
Static Pressure in inches w.g.
4" duct
FV-13VKL3/FV-13VKSL3
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
136
60
60
50
52
40
42
30
35
130
136
110
115
90
91
70
69
50
56
80
79
130
<0.3
0.5
<0.3
0.5
<0.3
0.5
<0.3
0.5
0.8
1.3
0.6
1.2
0.3
1.1
<0.3
0.9
<0.3
0.8
<0.3
0.6
0.8
1.3
Characteristics
7.4
12.4
6.0
11.6
5.3
9.0
4.2
7.8
3.8
6.7
3.5
6.2
14.4
24.7
11.0
20.0
8.0
15.3
6.1
10.8
4.2
8.7
7.4
12.4
14.4
24.7
11.2
6.6
11.9
6.8
12.1
7.2
12.5
7.0
11.1
6.6
8.8
5.8
9.0
5.5
10.1
5.8
11.5
6.1
12.0
6.7
12.3
6.7
11.2
6.6
9.0
5.5
Speed (RPM)
866
1166
815
1157
675
941
765
1106
758
1084
611
879
742
968
707
972
676
969
669
932
648
939
866
1166
742
968
Current (amps)
0.01
0.02
0.03
0.02
0.05
0.09
0.04
0.02
0.06
0.05
0.04
0.06
0.04
0.15
0.05
0.12
0.03
0.09
0.03
0.01
0.04
0.01
0.01
0.02
0.04
0.15
120/60
120/60
120/60
120/60
Yes
Yes
Yes
Yes
Approved Code/
Standard/
Regulation
FV-08VKSL3: No,
FV-08VKML3: Yes
FV-13VKSL3: No,
Yes
FV-13VKML3: Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
Yes
Yes
1 x 32
Lamp Watts
1 x 32
1 x 32
1 x 32
84
84
84
84
3,500
3,500
3,500
3,500
10,000
10,000
10,000
10,000
Lamp Model #
LPFHT32E35
LPFHT32E35
LPFHT32E35
LPFHT32E35
UL tub/Shower Enclosure
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
FV-13VKML3
0.1
78
0.25
0.6
20
0.1
70
6" duct
0.25
<0.3
FV-08VKL3/FV-08VKSL3
6" duct
0.1
79
Light
Specifications
Fits in 2 x 8 construction
0.25
0.6
FV-08VKML3
0.1
80
0.25
<0.3
Advanced
Features
0.1
FV-13VKL3
Noise (sones)
0.25
FV-08VKL3
4" duct
0.1
FV-13VKSL3/13VKML3
Single Speed
FV-08VKSL3/08VKML3
Bilti-in C0ntrols
N/A=not applicable
w.g.=water gauge
S.P.=static pressure
Panasonic ventilation fans may qualify for an energy saving rebate. Rebate programs are often provided by local utility
companies and based on ENERGY STAR guidelines. Check with your local utility company for details.
21
WhisperCeiling
Characteristics (HVI
Certified Data for 0.1" S.P.)
Approved Code/Standard/
Regulation
FV-05VQ5
FV-08VQ5
FV-11VQ5
FV-15VQ5
FV-20VQ3
FV-30VQ3
FV-40VQ3
0.1
0.1
0.1
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
348
0.25
0.25
0.25
50
36
80
62
110
91
150
127
190
144
290
257
380
Noise (sones)
<0.3
0.5
<0.3
0.4
<0.3
0.5
<0.3
0.5
1.3
N/A
2.0
N/A
3.0
N/A
11.0
11.5
14.7
14.5
21.1
20.7
28.4
27.3
42
42
64
62
112
111
4.7
3.2
5.8
4.5
5.3
4.5
5.3
4.7
4.5
3.4
4.6
4.1
3.4
3.1
Speed
731
1060
829
1089
950
1161
691
911
696
871
877
990
736
823
Current
0.09
0.10
0.12
0.12
0.18
0.17
0.24
0.23
0.35
0.35
0.53
0.52
0.94
0.92
120/60
Yes
UL Tub/Shower Enclosure
Yes
Yes
Yes
Yes
N/A=not applicable
w.g.=water gauge
S.P.=static pressure
6" duct
6" duct
FV-20VQ3/FV-30VQ3
22
Panasonic ventilation fans may qualify for an energy saving rebate. Rebate programs are often provided by local utility
companies and based on ENERGY STAR guidelines. Check with your local utility company for details.
FV-05VQ5/FV-08VQ5/FV-11VQ5
FV-15VQ5
6" duct
FV-40VQ3
23
THROUGH-THE-WALL FAN
FV-08WQ1 70 CFM
Exterior Hood
included
WhisperLite
Characteristics
(HVI Certified Data
for 0.1" S.P.)
FV-08VQL5
FV-11VQL5
0.1
0.25
0.1
0.25
0.1
0.25
80
62
110
90
150
128
Noise (sones)
<0.3
0.4
0.5
0.6
0.9
1.0
14.9
14.7
23.4
23.0
31.8
30.9
5.5
4.3
4.7
3.9
4.8
4.2
Speed
863
1117
1006
1193
800
988
Current
0.12
0.12
0.20
0.19
0.27
0.26
120/60
120/60
120/60
Yes
Yes
Yes
Lamp Watts
1 x 32
1 x 32
1 x 32
84
84
84
3,500
3,500
3,500
Lamp Model #
FHT32E35*
FHT32E35*
FHT32E35*
10,000
10,000
10,000
Lamp Watts
UL Tub/Shower Enclosure
Yes
Yes
Yes
Light
Specifications
Night-Light
Approved Code/
Standard/
Regulation
FV-15VQL5
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A=not applicable
w.g.=water gauge
S.P.=static pressure
6" duct
WhisperWall
Characteristics
(HVI Certified Data
for 0.1" S.P.)
Installation
Approved Code/
Standard/
Regulation
New Construction
0.03
70
Noise (sones)
1.1
18
3.9
Speed
660
Current
0.20
120/60
Yes
up to 10
Bird Screen
Yes
Spring Damper
Yes
Painted Galvanized
Yes
10-1/4
UL Tub/Shower Enclosure
Yes
Yes
3 year warranty
FV-08WQ1
Yes
N/A=not applicable
w.g.=water gauge
S.P.=static pressure
8" diam.
opening
3 year warranty
Remodeling
FV-08WQ1
FV-08VQL5/FV-11VQL5
FV-15VQL5
25
5-5/8"
Depth
WhisperFit
Characteristics
(HVI Certified Data
for 0.1" S.P.)
5-5/8"
Depth
FV-05VF2
4" Duct
4" Duct
FV-11VF2
3" Duct
4" Duct
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
50
30
50
31
80
60
70
53
110
94
90
78
Noise (sones)
0.4
N/A
0.5
N/A
0.8
N/A
0.8
N/A
1.5
N/A
1.5
N/A
15.0
14.7
15.0
14.8
24.5
24.3
24.3
24.0
33.5
33.2
33.8
33.5
3.3
2.0
3.3
2.1
3.3
2.5
2.9
2.2
3.3
2.8
2.7
2.3
Speed
637
932
741
978
757
956
845
1007
830
Current
0.13
0.12
0.13
0.12
0.20
0.20
0.20
0.20
0.28
0.28
120/60
0.28
120/60
120/60
Yes
Yes
Yes1
UL Tub/Shower Enclosure
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
3" Duct
Approved Code/
Standard/
Regulation
FV-08VF2
3" Duct
Characteristics
(HVI Certified Data
for 0.1" S.P.)
0.28
FV-05VFL2
4" Duct
Light Specifications
N/A=not applicable
w.g.=water gauge
S.P.=static pressure
Night-Light
Approved Code/
Standard/
Regulation
FV-08VFL2
3" Duct
4" Duct
FV-11VFL2
3" Duct
4" Duct
3" Duct
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
50
35
50
35
80
63
70
57
110
96
90
78
Noise (sones)
<0.3
N/A
<0.3
N/A
0.5
N/A
0.6
N/A
1.3
N/A
1.5
N/A
0.25
32.8
16.6
16.5
16.6
16.5
29.7
29.1
29.4
28.7
33.6
33.2
33.3
3.0
2.1
3.0
2.1
2.7
2.2
2.4
2.0
3.3
2.9
2.7
2.4
Speed
703
917
769
989
828
981
937
1067
906
1033
1048
1162
Current
0.14
0.14
0.14
0.14
0.25
0.24
0.25
0.24
0.28
0.28
0.28
0.27
WhisperFit-Lite
120/60
120/60
120/60
Yes
Yes
Yes1
Lamp Watts
2x18
2x18
2x18
84
84
84
3,500
3,500
3,500
Lamp Model #
FDS18E35/4*
FDS18E35/4*
FDS18E35/4*
10,000
10,000
10,000
Lamp Watts
UL Tub/Shower Enclosure
Yes
Yes
Yes1
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A=not applicable
w.g.=water gauge
S.P.=static pressure
*Lamp contains mercury. Dispose according to local, state and Federal laws.
3 year warranty
14-1/2" or 22-1/2
4"
4" duct
3"
14-1/2" or 22-1/2
4"
3 year warranty
5-5/8"
10-1/4"
3"
5-5/8
10-1/4"
14-1/2"
10-1/4
10-1/4
14-1/2"
INCLUDED:
4 to 3 inch adaptor
2-7/8
13"
13"
FV-05VF2/FV-08VF2/FV-11VF2
26
Panasonic ventilation fans may qualify for an energy saving rebate. Rebate programs are often provided by local utility
companies and based on ENERGY STAR guidelines. Check with your local utility company for details.
13
13
FV-05VFL2/FV-08VFL2/FV-11VFL2
27
3-3/4"
Depth
3-3/4"
Depth
WhisperValue
Characteristics
(HVI Certified Data
for 0.1" S.P.)
FV-08VS1
FV-10VS1
0.1
0.25
0.1
0.25
0.1
0.25
50
37
80
65
100
90
Noise (sones)
0.8
N/A
1.4
N/A
1.5
N/A
15.8
15.3
23.3
23.6
36.4
36.1
3.2
2.4
3.4
2.8
2.9
2.7
Speed (RPM)
759
948
878
1026
840
979
Current (amps)
0.04
0.04
0.11
0.11
0.30
Approved Code/
Standard/ Regulation
FV-05VS1
4" Oval Duct
120/60
120/60
0.30
120/60
UL Tub/Shower Enclosure
Yes
Yes
Yes
UL Wall Installation
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Motor/Grille
Assembly
Complete
Fan Unit
Master
Pack
FV-05-08VSA1
FV-05VSB1
FV-05VS1
FV-05-08VSA1
FV-08VSB1
FV-08VS1
FV-05-08VSA1
FV-10VSB1
FV-10VS1
Light Specifications
Night-Light
0.1
0.25
0.1
80
67
100
0.25
90
Noise (sones)
1.3
N/A
1.5
N/A
36.3
24.4
24.9
36.6
3.3
2.7
2.9
2.6
Speed (RPM)
944
1063
911
1019
Current (amps)
0.11
0.11
0.30
0.30
120/60
120/60
UL Tub/Shower Enclosure
Yes
Yes
Yes
Yes
Yes
Yes
Lamp Watts
2x18
2x18
84
84
3,500
3,500
Lamp Model #
FDS18E35/4*
FDS18E35/4*
10,000
10,000
Lamp Watts
N/A=not applicable
w.g.=water gauge
S.P.=static pressure
Universal
Housing Can
Motor/Grille
Assembly
Complete
Fan Unit
Master
Pack
FV-08VSLA1
FV-08VSLB1
FV-08VSL1
FV-08VSLA1
FV-10VSLB1
FV-10VSL1
5/8
4-
3-1/16
3-3/4
5/
3-1/16
3-3/4
14-1/2
10-1/4
14-1/2
10-1/4
10-1/4
10-1/4
13
13
Panasonic ventilation fans may qualify for an energy saving rebate. Rebate programs are often provided by local utility
companies and based on ENERGY STAR guidelines. Check with your local utility company for details.
Approved Code/
Standard/ Regulation
14-1/2 or 22-1/2
14-1/2 or 22-1/2
4-
28
Characteristics
(HVI Certified Data
for 0.1" S.P.)
FV-10VSL1
3 year warranty
FV-08VSL1
4" Oval Duct
3 year warranty
WhisperValue-Lite
N/A=not applicable
w.g.=water gauge
S.P.=static pressure
FV-10VS1
13
13
FV-08VSL1/FV-10VSL1
29
WINTER
OUTSIDE
SUMMER
Cool
INSIDE
40 CFM
20 CFM
10 CFM
0.1
0.1
0.1
40
20
10
30
20
10
N/A
Noise (sones)
0.8
<0.3
23
21
17
Speed
1479
1292
1095
Current
0.15
0.10
0.09
120/60
Motor Type
Condenser
Ball
Yes
2 x Sirocco
Supply Filter
MERV 6
66% at 30 CFM
Apparent Sensible
Effectiveness
Fits in 2x 8 construction
Thermal fuse protection
Note:
3 year warranty
Without ERV
N/A=not applicable
w.g.=water gauge
S.P.=static pressure
2 x 4" ducts
Warm
13-1/2 to 16
7-7/8
18-1/2
13-1/2
13-1/2 to 16
Inside
Outside
Balanced Ventilation
Panasonic WhisperComfort spot ERVs use two ducts one to exhaust stale air and the other to supply fresh air
from outside. Its low-rate, continuous run helps ensure
chemicals and indoor pollutants are vented out and
replaced with fresh air.
6-5/8
22-1/8
4" duct
Warm
Characteristics
2 x 4 inch ducts
FV-04VE1
WhisperComfort
20-3/4
16-3/4
30
Panasonic ventilation fans may qualify for an energy saving rebate. Rebate programs are often provided by local utility
companies and based on ENERGY STAR guidelines. Check with your local utility company for details.
FV-04VE1
31
WhisperWarmTM
Characteristics
(HVI Certified Data for
0.1" S.P.)
Specifications
FV-11VHL2 INCLUDES:
2 Panasonic 18-Watt
CFL/3500 Kelvin/
High CRI/1200 Lumens
each/ENERGY STAR
qualified/10,000 hours rated
average life/equivalent to
100-Watt incandescent lamp/
electronic ballast for flickerfree operation
3 year warranty
ASHRAE 62.2, LEED for Homes, ENERGY STAR IAP, CA Title
24, EarthCraft and WA Ventilation Code compliant
4" duct
4" duct
Installation
Light Specifications
14-1/2 or 22-1/2
4
16
7-3/4
11-1/2
Heater
14-1/2
32
Panasonic ventilation fans may qualify for an energy saving rebate. Rebate programs are often provided by local utility
companies and based on ENERGY STAR guidelines. Check with your local utility company for details.
0.1
0.25
0.1
110
89
110
0.25
89
Noise (sones)
0.6
N/A
0.7
N/A
30.7
30.5
30.6
30.5
3.6
2.9
3.6
2.9
Speed (RPM)
778
935
812
956
Current (amps)
0.25
0.25
0.25
0.25
120/60
120/60
Motor Type
Condenser
Condenser
Ball
Ball
Yes
Yes
Sirocco
Sirocco
N/A
N/A
17-3/8 x 12-5/8
17-3/8 x 12-5/8
18-1/8L x 135/16W
18-1/8L x 14-1/8W
2 x 18W
Lamp Watts
N/A
N/A
84
N/A
3,500
N/A
10,000
Lamp Model #
N/A
FDS18E35/4*
N/A
Yes
Yes
Directional Louver
N/A
N/A
1,400
1,400
90
90
25
25
Combined
Amps
12.2
12.5
Shipping
20.1
22.7
14-1/8
FV-11VH2
FV-11VHL2
18-1/8
FV-11VHL2
FV-11VH2
*Lamp contains mercury. Dispose according to local, state and Federal laws.
33
REMO T E M O U N T I N - L I N E FA N
Housing:
WhisperLine
Characteristics
(HVI Certified Data
for 0.2 S.P.)
Motor:
FV-20NLF1
FV-30NLF1
FV-40NLF1
0.2
0.3
0.4
0.2
0.3
0.4
0.2
0.3
0.4
0.2
0.3
0.4
120
105
82
240
225
200
340
322
302
440
425
408
Noise (sones)
1.0
1.4
1.7
2.1
36
57
98
132
3.3
4.2
3.5
3.3
Speed
1590
1260
1337
1150
Accessory
Kit
Model No.
Description
Inlet Grille
Backdraft Damper
Clamp
FV-NLF04G
1 (4")
Y-Adaptor
-
FV-NLF06G
1 (6")
PC-NLF04S
1 (4")
1 (4")
PC-NLF06S
1 (6")
1 (6")
PC-NLF04D
2 (4")
2 (4")
12
1 (4"- 4"x 2)
1 (6"- 6"x 2)
Current
0.31
0.46
0.86
1.10
120/60
120/60
120/60
120/60
Yes
Yes
Yes
Yes
PC-NLF06D
2 (6")
2 (6")
12
PC-NLF64D
2 (4")
2 (4")
12
1 (6"- 4"x 2)
9-1/2
9-1/2
9-1/2
9-1/2
PC-NLF86Y
8"-6" Y-Adaptor
1 (8"- 6"x 2)
Installation
Approved Code/
Standard/
Regulation
FV-10NLF1
UL Tub/Shower Enclosure
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Note: Sones were measured at manufacturers facility in a sound-proof room at intake side from a distance of 5 ft.
To ensure quiet operation of ENERGY STAR qualified in-line and remote fans, each fan should be installed using
sound attenuation techniques appropriate for the installation. For bathroom and general ventilation applications, at
least 8 feet of insulated flexible duct must be installed between the exhaust or supply grille(s) and the fan.
Y-Adaptor
Yes
N/A=not applicable
w.g.=water gauge
S.P.=static pressure
34
WhisperLine Dimensions
Fan Model
FV-10NLF1
13-3/8"
9-1/2"
17-5/16"
7-7/8"
12-5/8" - 22-3/4"
5/16"
4"
11"
FV-20NLF1
13-3/8"
9-1/2"
21-5/8"
9-7/16"
12-5/8" - 24-7/16"
5/16"
6"
11"
FV-30NLF1
15-11/32"
10-5/8"
23-5/8"
11"
12-5/8" - 26"
5/16"
6"
12-1/8"
FV-40NLF1
16-1/2"
13-3/8"
22"
11"
12-5/8" - 26"
5/16"
8"
14-7/8"
Panasonic ventilation fans may qualify for an energy saving rebate. Rebate programs are often provided by local utility
companies and based on ENERGY STAR guidelines. Check with your local utility company for details.
35
T-Bar Ceiling
CEILIN G R A D I AT I O N D A M P E R
PC-RD05C3
FV-GL3MTL
CLASSIFIED
See details on UL
classification marking on
each product
File # R16724
Characteristics
E
AT
ST
FV-GL3MTL
14-1/5
13
1.1
1.3
1.5
Traditional
Traditional
Commercial
F IR
Material
ABS
ABS
26 Gauge
Galvanized Steel
UL Approved1
Yes
Yes
Yes
HVI Certified1
Yes
Yes
Yes
Yes
Yes
Yes
RoHs Compliant
Yes
Yes
Yes
AL
TE
FV-GL3TDB
13
A
ST
FV-GL3TDA
Shipping
Gross Weight (lbs)
E MAR
SH
R VI C
TIN
I SOF CALIFO G
FILE:# 3225-1598:100
File # WHI-495-PSH-0177,-0178
Damper
Model
PC-RD05C3
WhisperGreen:
FV-13VK3, FV-08VK3, FV-05VK3
WhisperCeiling:
FV-15VQ5, FV-11VQ5,
FV-08VQ5, FV-05VQ5
PA S S I V E I N L E T V E N T
*PBB and PBDE are flame retardants used in some plastics.
FV-GKF32S1
WhisperFit:
FV-11FV2, FV-08VF2, FV-05VF2
WhisperValue:
FV-10VS1, FV-08VS1, FV-05VS1
Applicable Models
NI
FV-GL3TDB
FV-GL3TDA
Panasonic Passive Inlet provides makeup (outside) air to help balance indoor vs.
outdoor air pressure.
Passive Inlet
Specifications
Features
Installation
FV-GKF32S1
CFM Settings
12 & 18
Yes
Yes
Bug Screen
Yes
3 x 12 Sleeve Included
Yes
Body
ABS & PP
3 inch
Yes
37
Locate
MAX CFM TABLE using Q5 Dual Adapter and 3-4" and 4-6" increasers
WhisperLine In-Line Bathroom (to achieve 8 ACH as per HVI)
50 cfm
40 cfm
40 cfm
40 cfm
3"
40 cfm
30 cfm
30 cfm
30 cfm
4"
50 cfm
40 cfm
40 cfm
40 cfm
3"
40 cfm
30 cfm
30 cfm
30 cfm
4"
50 cfm
50 cfm
50 cfm
50 cfm
4"
50 cfm
50 cfm
40 cfm
40 cfm
6"
50 cfm
50 cfm
50 cfm
50 cfm
4" Oval
50 cfm
50 vfm
40 cfm
40 cfm
4"
70 cfm
60 cfm
60 cfm
50 cfm
3"
50 cfm
40 cfm
30 cfm
30 cfm
4"
70 cfm
60 cfm
60 cfm
50 cfm
FV-08VK3
4"
80 cfm
80 cfm
80 cfm
70 cfm
FV-08VKL3
4"
80 cfm
80 cfm
80 cfm
70 cfm
FV-08VKM3
4"
80 cfm
80 cfm
80 cfm
70 cfm
Longest duct run from grille to fan and to the outside exhaust point
Installation Kit
20 feet
30 feet
40 feet
50 feet
75 feet
50
PC-NLF04S
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
75
PC-NLF06S
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
PC-NLF06S
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
PC-NLF06D
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
PC-NLF06D
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
PC-NLF06S
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-20NLF1
FV-20NLF1
PC-NLF06D
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-20NLF1
FV-20NLF1
PC-NLF06D
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-20NLF1
FV-20NLF1
PC-NLF06S
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
PC-NLF06D
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
PC-NLF06D
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
PC-NLF06D
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
PC-NLF06D + PC-NLF06S
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
PC-NLF06D
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-30NLF1
PC-NLF06D + PC-NLF06S
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
PC-NLF06D
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
PC-NLF06D + PC-NLF06S
FV-20NLF1
FV-20NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
250
PC-NLF06D + PC-NLF06S
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
275
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
100
125
150
175
200
225
FV-08VKML3
4"
80 cfm
80 cfm
80 cfm
70 cfm
FV-08VKS3
4"
80 cfm
80 cfm
80 cfm
70 cfm
300
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-08VKSL3
4"
80 cfm
80 cfm
80 cfm
70 cfm
325
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
4"
70 cfm
60 cfm
60 cfm
60 cfm
PC-NLF06D x 2 +PC-NLF86Y
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
6"
80 cfm
80 cfm
80 cfm
80 cfm
FV-40NLF1
FV-40NLF1
NA
NA
NA
4"
70 cfm
60 cfm
60 cfm
60 cfm
PC-NLF06D x 2 +PC-NLF86Y
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
375
PC-NLF06D x 2 +PC-NLF86Y
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
6"
80 cfm
80 cfm
80 cfm
80 cfm
400
PC-NLF06D x 2 +PC-NLF86Y
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-08VS1
4" Oval
70 cfm
70 cfm
60 cfm
60 cfm
FV-08VSL1
4" Oval
70 cfm
70 cfm
60 cfm
60 cfm
FV-10VS1
4" Oval
100 cfm
90 cfm
80 cfm
70 cfm
FV-10VSL1
4" Oval
100 cfm
90 cfm
80 cfm
70 cfm
4"
90 cfm
80 cfm
70 cfm
70 cfm
House Sq Ft
PICKUPS
Installation kit
20 feet
30 feet
40 feet
50 feet
75 feet
3"
60 cfm
50 cfm
40 cfm
40 cfm
750
PC-NLF04S
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
4"
90 cfm
80 cfm
70 cfm
70 cfm
3"
60 cfm
50 cfm
40 cfm
40 cfm
4"
90 cfm
80 cfm
90 cfm
90 cfm
4" to 6"
adapter
110 cfm
110 cfm
110 cfm
110 cfm
4"
90 cfm
80 cfm
90 cfm
4" to 6"
adapter
110 cfm
110 cfm
110 cfm
4"
90 cfm
80 cfm
90 cfm
FV-11VHL2
FV-11VQ5
FV-11VQL5
350
750
PC-NLF04D
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
1,000
PC-NLF04S
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
1,000
PC-NLF04D
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
1,250
PC-NLF06S
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
1,250
PC-NLF06D
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
1,500
PC-NLF06S
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
90 cfm
1,500
PC-NLF06D
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
FV-10NLF1
2,000
PC-NLF06D
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
110 cfm
2,500
PC-NLF06D
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
3,000
PC-NLF06D
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
90 cfm
3,000
PC-NLF06D + PC-NLF06S
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
6"
110 cfm
110 cfm
110 cfm
110 cfm
3,500
PC-NLF06D
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
4"
90 cfm
80 cfm
90 cfm
90 cfm
3,500
PC-NLF06D + PC-NLF06S
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
6"
110 cfm
110 cfm
110 cfm
110 cfm
4,000
PC-NLF06D
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
4,000
PC-NLF06D + PC-NLF06S
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-20NLF1
FV-13VK3
6"
130 cfm
130 cfm
130 cfm
130 cfm
4,500
PC-NLF06D
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-13VKL3
6"
130 cfm
130 cfm
130 cfm
130 cfm
4,500
PC-NLF06D + PC-NLF06S
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-13VKM3
6"
130 cfm
130 cfm
130 cfm
130 cfm
5,000
PC-NLF06D + PC-NLF06S
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-13VKML3
6"
130 cfm
130 cfm
130 cfm
130 cfm
5,000
Two PC-NLF06D
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
5,500
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-13VKS3
6"
130 cfm
130 cfm
130 cfm
130 cfm
5,500
PC-NLF06D + PC-NLF06S
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-30NLF1
FV-13VKSL3
6"
130 cfm
130 cfm
130 cfm
130 cfm
6,000
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
6,000
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
6,500
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-15VQ5
38
4"
30 cfm
FV-11VH2
100 feet
30 cfm
FV-11VFL2
80 feet
40 cfm
FV-11VF2
60 feet
50 cfm
FV-08VQL5
40 feet
3"
FV-08VQ5
Duct size
6"
150 cfm
150 cfm
140 cfm
140 cfm
FV-15VQL5
6"
150 cfm
150 cfm
140 cfm
140 cfm
6,500
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-20VQ3
6"
190 cfm
180 cfm
170 cfm
170 cfm
7,000
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
7,500
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-40NLF1
FV-30VQ3
6"
260 cfm
240 cfm
230 cfm
220 cfm
FV-40VQ3
6"
340 cfm
320 cfm
300 cfm
280 cfm
39
Single Speed
Built-in Controls
Single Speed
Built-in Controls
Single Speed
FV-08VK3
Single Speed
Built-in Controls
FV-13VKL3
Airflow (CFM)
Built-in Controls
Airflow(CFM)
FV-13VKM3/S3
Airflow (CFM)
FV-13VKML3/SL3
Airflow(CFM)
FV-08VKML3/SL3
FV-08VKL3
Performance Curves
FV-08VKM3/S3
FV-05VK3
Airflow(CFM)
Airflow (CFM)
Airflow (CFM)
Airflow (CFM)
Single Speed
FV-13VK3
Static Pressure(inch w.g.)
Airflow (CFM)
41
4" Duct
1.60
1.40
1.20
FV-40VQ3
1.00
20 Feet
0.80
40 Feet
0.60
80 Feet
60 Feet
100 Feet
0.40
FV-08VQL5
Static Pressure(inch w.g.)
FV-40VQ3
FV-15VQ5
0.00
Airflow(CFM)
FV-08VQ5
4" Duct
Airflow(CFM)
6" Duct
0.70
0.60
0.50
FV-20VQ3
20 Feet
0.40
40 Feet
60 Feet
0.30
80 Feet
100 Feet
6" Duct
Airflow(CFM)
4" Duct
50
100
150
200
Airflow(CFM)
1.00
0.80
FV-30VQ3
0.60
20 Feet
40 Feet
60 Feet
80 Feet
Airflow(CFM)
6" Duct
0.20
Airflow(CFM)
100 Feet
FV-15VQL5
0.40
FV-30VQ3
Static Pressure(inch w.g.)
4" Duct
0.00
6" Duct
FV-11VQ5
0.10
FV-11VQL5
0.20
Airflow(CFM)
FV-20VQ3
4" Duct
6" Duct
0.20
Performance Curves
FV-05VQ5
0.00
Airflow(CFM)
43
FV-05VF2
3" duct
0.35
0.30
20 Feet
0.25
40 Feet
0.20
60 Feet
0.15
80 Feet
0.10
100 Feet
0.35
0.30
20 Feet
0.25
40 Feet
0.20
60 Feet
0.15
80 Feet
0.10
100 Feet
0.00
20
40
FV-05VF2
4" duct
60
80
Airflow(CFM)
20
40
20 Feet
0.40
40 Feet
0.30
60 Feet
0.20
100 Feet
50
0.50
0.50
FV-08VF2
4" duct
20 Feet
FV-11VHL1
0.40
0.40
20 Feet
40 Feet
40 Feet
0.30
0.30
60
60 Feet
Feet
80 Feet
0.00
0.00
20 Feet
0.35
40 Feet
0.30
0.25
60 Feet
50 50 75
0.45
FV-05VFL2
4" duct
0.40
20 Feet
0.35
0.30
40 Feet
0.25
60 Feet
80 Feet
0.15
100 Feet
100 Feet
0.10
0.05
20
40
0.00
60
80
Airflow(CFM)
20
40
60
80
Airflow(CFM)
FV-08VFL2
0.70
0.60
FV-08VFL2
3" duct
0.50
20 Feet
0.40
40 Feet
0.30
60 Feet
80 Feet
0.20
0.00
100 100
125
Airflow(CFM)
Airflow(CFM)
0.70
0.60
50
20 Feet
0.40
40 Feet
0.30
60 Feet
80 Feet
100 Feet
0.10
0.00
FV-08VFL2
4" duct
0.50
0.20
100 Feet
0.10
25
0.50
FV-08VFL2
100 Feet
00
0.55
0.20
80 Feet
0.10
100
Feet
80 Feet
0.10
0.10
100
Airflow(CFM)
FV-05VFL2
3" duct
0.40
0.00
0.60
0.60
0.20
0.20
80 Feet
0.10
0.00
Static
Static Pressure(inch
Pressure(inch w.g.)
w.g.)
FV-08VF2
3" duct
0.45
0.15
60
80
Airflow(CFM)
FV-08VF2
0.50
0.50
0.05
FV-08VF2
0.60
0.55
0.20
0.05
0.05
0.00
0.40
0.40
0.45
0.45
FV-05VFL2
FV-05VFL2
FV-05VF2
100
Airflow(CFM)
50
100
Airflow(CFM)
FV-11VFL2
0.90
0.80
FV-11VF2
3" duct
0.70
0.60
20 Feet
0.50
40 Feet
0.40
60 Feet
0.30
0.20
0.80
FV-11VF2
4" duct
0.70
0.60
20 Feet
0.50
40 Feet
0.40
60 Feet
80 Feet
0.30
100 Feet
0.20
80 Feet
100 Feet
0.00
0
25
50
75
100
125
Airflow(CFM)
0.90
0.80
FV-11VFL2
3" duct
0.70
25
50
75
100
125
Airflow(CFM)
40 Feet
0.40
60 Feet
80 Feet
0.30
80 Feet
100 Feet
0.20
100 Feet
40 Feet
0.40
60 Feet
0.00
FV-11VFL2
4" duct
0.70
0.50
0.50
0.20
0.80
20 Feet
20 Feet
0.30
0.90
0.60
0.60
0.10
0.10
0.10
0.10
0.00
0.90
FV-11VFL2
Static Pressure(inch w.g.)
FV-11VF2
FV-11VF2
Performance Curves
FV-05VF2
25
50
75
100 125
Airflow(CFM)
0.00
25
50
75
100 125
Airflow(CFM)
45
Airflow(CFM)
0.70
0.60
40 Feet
0.30
80 Feet
0.10
0.00
20 Feet
0.40
FV-10NLF1
0.50
0.20
0.80
Airflow(CFM)
60 Feet
100 Feet
20
40
60
Airflow(CFM)
0.70
40 Feet
0.50
80 Feet
20 Feet
0.60
60 Feet
0.40
100 Feet
0.70
0.60
FV-20NLF1
20 Feet
0.50
40 Feet
0.40
60 Feet
0.30
100 Feet
Airflow(CFM)
80 Feet
0.70
0.60
0.50
50
0.20
0.10
0.40
FV-04VE1
(Exhaust)
FV-04VE1
(Supply)
0.30
20 Feet
40 Feet
60 Feet
0.20
80 Feet
100 Feet
0.10
1.00
0.90
FV-30NLF1
20 Feet
40 Feet
0.60
0.50
0.40
0.30
0.20
Airflow(CFM)
10
20
30
40
50
60
Airflow(CFM)
75
100
125
Airflow(CFM)
0.70
0.60
0.50
FV-11VHL2
20 Feet
40 Feet
60 Feet
80 Feet
100 Feet
0.40
60 Feet
0.30
100 Feet
0.20
0.10
0.00
0.00
50
80 Feet
0.10
46
1.10
0.70
25
1.20
0.80
FV-11VHL2
Static Pressure(inch w.g.)
FV-30NLF1
FV-04VE1
FV-11VH2
20 Feet
40 Feet
60 Feet
80 Feet
100 Feet
0.40
0.30
FV-10VS1
0.50
Airflow(CFM)
FV-11VH2
0.00
0.80
0.00
FV-40NLF1
0.80
0.90
0.10
0.90
0.20
1.00
FV-20NLF1
1.10
0.00
FV-10VSL1
1.20
0.10
1.30
0.20
FV-08VS1
1.40
0.30
FV-40NLF1
FV-10NLF1
FV-08VSL1
Performance Curves
FV-05VS1
0.00
25
50
75
100
125
Airflow(CFM)
47
Complete Specifications
*Lamp contains mercury. Dispose according to local, state and Federal laws.
WhisperGreen
FV-08VKS3 | FV-08VKM3
Static pressure in inches w. g.
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
80
79
70
75
60
59
50
54
40
39
30
90
93
70
71
50
53
9.8
2.4
FV-08VK3
FV-08VKSL3 | FV-08VKML3
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
50
54
80
79
130
135
80
79
70
78
60
60
50
52
40
42
30
35
130
136
110
115
90
91
70
69
50
56
80
<0.3
0.6
<0.3
0.6
<0.3
0.5
<0.3
0.5
<0.3
0.5
<0.3
0.5
0.8
1.3
0.6
1.2
0.3
1.1
<0.3
0.9
<0.3
0.8
9.0
4.2
7.8
3.8
6.7
3.5
6.2
8.0
15.3
6.1
10.8
4.2
7.0
11.1
6.6
7.0
11.0
5.4
10.1
5.0
8.7
4.3
7.5
3.7
6.6
3.2
5.9
4.3
7.5
7.0
7.4
12.4
6.0
11.6
5.3
12.1
7.6
13.3
7.7
13.6
7.7
12.4
7.7
12.8
7.1
11.4
6.7 11.2 6.4 12.5 7.3 15.2 7.8 18.7 7.9 23.3 10.0
12.4
7.7
12.1
7.6
6.6
11.9
6.8
FV-13VKSL3 | FV-13VKML3
FV-08VKL3
FV-05VQ5
FV-08VQ5
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25
0.1
0.25 0.1
79
130
136
50
36
80
62
110
91
150
127
190
144
290
257
380
348
<0.3
0.6
0.8
1.3
1.3
N/A
2.0
N/A
8.7
7.4
12.4
14.4
24.7
42
42
64
62
4.5
5.3
4.5
FV-20VQ3
FV-30VQ3
0.1
0.25
0.1
0.25
62
110
90
150
128
3.0
0.5
0.6
0.9
1.0
112
80
11.2
6.4
11.2
12.1
7.2
12.5
8.8
5.8
9.0
5.5
10.1
5.8
11.5
6.1
12.0
6.7
12.3
6.7
11.2
6.6
9.0
5.5
4.7
5.3
4.7
4.5
3.4
4.6
4.1
3.4
3.1
5.5
4.8
4.2
917
866 1166
941
879
742
968
707
972
676
969
669
932
648
939
866
1166
742
968
911
696
871
877
990
736
823
988
Current
0.02 0.01 0.03 0.01 0.05 0.01 0.05 0.02 0.05 0.03 0.06 0.04 0.01 0.12 0.03 0.09 0.02 0.07 0.04 0.01 0.06 0.03
0.01 0.02
0.03 0.02 0.05 0.09 0.04 0.02 0.06 0.05 0.04 0.06 0.04 0.15 0.05 0.12 0.03 0.09 0.03 0.01 0.04 0.01
0.01
0.02
0.04
0.15
0.09 0.10 0.12 0.12 0.18 0.17 0.24 0.23 0.35 0.35 0.53 0.52 0.94 0.92 0.12 0.12 0.20 0.19 0.27 0.26
4.3
4.7
3.9
120/60
120/60
120/60
120/60
120/60
120/60
120/60
120/60
120/60
120/60
120/60
Motor Type
DC
DC
DC
DC
DC
DC
DC
DC
DC
Condenser
Condenser
Ball
Ball
Ball
Ball
Ball
Ball
Ball
Ball
Ball
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Sirocco
Sirocco
Sirocco
Sirocco
Sirocco
Sirocco
Sirocco
Sirocco
Sirocco
Sirocco
Sirocco
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10-1/2
10-1/2
10-1/2
10-1/2
10-1/2
10-1/2
10-1/2
10-1/2
10-1/2
13
13
FV-08VKS3: No
FV-08VKM3: Yes
FV-13VKS3: No
FV-13VKM3: Yes
13
13
13
No
No
No
13
FV-08VKSL3: No
Single Speed
Ball
Yes
Built-in Controls
Ball
Single Speed
13
FV-08VKML3: Yes
FV-13VKSL3: No
FV-13VKML3: Yes
13
13
No
No
Advanced
Yes
Yes
No
No
No
Yes
Yes
No
No
Features
Yes
Yes
No
No
No
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
4 or 6
4 or 6
4 or 6
Yes
10-1/2
13
12-3/16
13
13
13
4 or 6
14-3/4
15
15
4 or 6
17-11/16
13
13
Yes
Yes
Yes
Yes
1 x 32
1 x 32
1 x 32
1 x 32
84
84
84
84
84
3,500
3,500
3,500
3,500
3,500
10,000
10,000
10,000
10,000
Lamp Model #
LPFHT32E35*
LPFHT32E35*
Shipping
12.1
12.6
12.1
12.1
12.6
13.4
13.9
13.4
13.9
UL Tub/Shower Enclosure
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10,000
LPFHT32E35*
4
10.4
10.4
10.4
11.5
17.2
18.3
27.3
12.6
12.6
Yes
Yes
Approved Code/
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Standard/ Regulation
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
FV-08WQ1
Static pressure in inches w. g.
Characteristics
(HVI Certified Data
for 0.1 S.P.)
Specifications
0.03
WhisperFit
FV-05VF2
4" Duct
0.1
3" Duct
0.25
0.1
WhisperFit-Lite
FV-08VF2
0.2 5
4" Duct
0.1
FV-11VF2
3" Duct
0.25
0.1
0.25
4" Duct
0.1
FV-05VFL2
3" Duct
0.25
0.1
0.25
4" Duct
0.1
70
50
30
50
31
80
60
70
53
110
94
90
78
Noise (sones)
1.1
0.4
N/A
0.5
N/A
0.8
N/A
0.8
N/A
1.5
N/A
1.5
N/A <0.3
18
0.1
0.25
0.1
0.25
4" Duct
0.1
0.25
3" Duct
0.1
0.25
FV-10VS1
FV-08VSL1
FV-10VSL1
0.1
0.1
0.1
0.25
0.1
0.25
0.1
0.25
0.25
0.25
Night-Light Specs
40 CFM
20 CFM
10 CFM
0.1
0.1
0.1
Exhaust 40
Exhaust 20
Exhaust 10
FV-11VH2
Shipping
Approved Code/
Standard/ Regulation
FV-20NLF1
FV-30NLF1
FV-40NLF1
0.25
0.1
0.25
0.2
0.3
0.4
0.2
0.3
0.4
0.2
0.3
0.4
0.22
0.3
0.4
110
89
110
89
120
105
82
240
225
200
340
322
302 440
425
408
96
90
78
50
37
80
65
100
90
80
67
100
90
Supply 30
Supply 20
Supply 10
N/A
0.5
N/A
0.6
N/A
1.3
N/A
1.5
N/A
0.8
N/A
1.4
N/A
1.5
N/A
1.3
N/A
1.5
N/A
0.8
<0.3
N/A
0.6
N/A
0.7
N/A
1.0
1.4
1.7
2.1
15.0 14.7 15.0 14.8 24.5 24.3 24.3 24.0 33.5 33.2 33.8 33.5 16.6 16.5 16.6 16.5 29.7 29.1 29.4 28.7
33.6
33.2 33.3
32.8
15.8
15.3
23.3
23.6
36.4
36.1
24.4
24.9
36.6
36.3
23
21
17
30.7
30.5
30.6
30.5
36
57
98
132
3.6
2.9
3.6
2.9
3.3
4.2
3.5
3.3
1292
1095
778
935
812
956
1590
1260
1337
1150
0.10
0.09
0.25
0.25
0.25
0.25
3.9
3.3
2.0
3.3
2.1
3.3
2.5
2.9
3.0
2.1
3.0
2.1
2.7
2.2
2.4
2.4
3.2
2.4
3.4
2.8
2.9
2.7
3.3
2.7
2.9
2.6
Speed
660
637
932
741
978
757
956
2.7
2.3
917
769
989
828
981
937 1067
2.0
906
3.3
1033 1048
2.9
2.7
1162
759
948
878
1026
840
979
944
1063
911
1019
1479
N/A
0.13 0.12 0.13 0.12 0.20 0.20 0.20 0.20 0.28 0.28 0.28 0.28 0.14 0.14 0.14 0.14 0.25 0.24 0.25 0.24
0.28
0.28 0.28
0.27
0.04
0.04
0.11
0.11
0.30
0.30
0.11
0.11
0.30
0.30
0.15
Current
0.20
120/60
120/60
120/60
120/60
120/60
120/60
120/60
0.31
0.46
0.86
1.10
120/60
120/60
120/60
120/60
24
26
Motor Type
Condenser
Condenser
Condenser
Condenser
Condenser
Condenser
Condenser
Condenser
Sleeve
Ball
Ball
Ball
Ball
Ball
Ball
Ball
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Propeller
Sirocco
Sirocco
Sirocco
Sirocco
2 x Sirocco
Sirocco
Sirocco
Yes
Yes
MERV 6
Yes
Yes
Yes
Yes1
Yes
Yes
Yes1
4/3
4/3
2x4
N/A
8-1/2
10-7/8
10-7/8
10-7/8
10-7/8
19-1/2 x 14-1/4
17-3/8 x 12-5/8
17-3/8 x 12-5/8
N/A
10-1/4
13
13
13
20-3/4 x 16-3/4
18-1/8Lx 13-5/16
18-1/8 x 14-1/8
9-1/2
13
2x18
2x18
84
84
3,500
3,500
10,000
10,000
Lamp Model #
FDS18E35/4*
FDS18E35/4*
Yes
2x18 watts
84
3,500
10,000
FDS18E35/4*
4
Yes
Directional Louver
Yes
1,400
80
Combined
FV-10NLF1
0.1
Heater
FV-11VHL2
110
N/A <0.3
13.7
WhisperLine
57
Lamp Watts
Light Specifications
WhisperWarm
FV-04VE1
70
Supply Filter
Installation
WhisperComfort
FV-08VS1
63
2.8
50
0.25
3" Duct
WhisperValue-Lite
FV-05VS1
80
3.3
35
0.1
4" Duct
FV-11VFL2
35
2.2
50
3" Duct
0.25
WhisperValue
FV-08VFL2
13
1 x 32
LPFHT32E35* LPFHT32E35*
Night-Light Specs
10-1/2
Lamp Watts
WhisperWall
48
5.8
FV-15VQ5
Light
3.2
FV-11VQ5
832 1130 791 1125 773 1106 749 1101 740 1093 745 1087 662 917 643 912 580 900 506 874 430 781
Specifications
WhisperLite
FV-13VKL3
Speed
32
FV-13VK3
WhisperCeiling
FV-05VK3
Built-in Controls
Specifications
0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25
<0.3 0.4 <0.3 0.4 <0.3 0.3 <0.3 0.3 <0.3 <0.3 <0.3 <0.3 <0.3 0.7 <0.3 0.6 <0.3 0.6 <0.3 0.4 <0.3 <0.3
Noise (sones)
Characteristics
(HVI Certified Data
for 0.1 S.P.)
WhisperGreen-Lite
FV-13VKS3 | FV-13VKM3
24
24
Amps
12.1
12.8
12.1
UL Tub/Shower Enclosure
Yes
11.2
11.2
Yes
11.2
14.3
14.3
14.3
9.7
9.7
Yes
Yes
9.9
12.3
12.5
Yes
24
No
28.2
31.5
No
14
17
Yes
UL Wall Installation
Yes
No
No
Yes
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
49
Notes:
50
51
www.panasonic.com/building