Security Level
Prerequisites
The TCP/IP protocol is installed on the SMT PC.
Procedure
1. To set the IP address of the PC, perform the following steps where the Windows
XP operating system is taken as an example: On Windows XP, choose Start >
Setting > Control Panel.
2. Double-click Network Connections in the displayed Control Panel window. Rightclick Local Area Connection in the displayed dialog box.
3. Choose Properties from the shortcut menu. The Local Area Connection
Properties dialog box is displayed.
4. Select Internet Protocol (TCP/IP), and click Properties. The Internet Protocol
(TCP/IP) Properties dialog box is displayed.
5. Select Use the following IP address.
6. Enter the correct IP address, subnet mask, and default gateway. Ensure that the IP
address of the SMT PC is in the same network segment as the IP addresses
(192.168.0.72/255.255.255.0) of the BTS so that a maintenance channel on the
BTS side can be established.
7. Click OK to complete the settings.
Parent topic: Starting the Site Maintenance Terminal System
Prerequisites
The IP address and subnet mask of the SMT PC are set correctly. The IP address is in
the same network segment as the IP address (192.168.0.72/255.255.255.0) of the BTS.
Procedure
1.
2.
Connect the SMT PC to the BTS through an Ethernet cable. One end is connected to
the Ethernet port on the main control board of the basic cabinet, and the other end is
connected to the Ethernet port on the SMT PC (usually a portable PC).
Open the MS-DOS Prompt dialog box.
2016-05-23
Page1, Total4
Document Title
3.
Security Level
If the PC is Windows 2000/XP operating system based, choose Start > Run
on the SMT. In the Run dialog box, run the cmd command. The MS-DOS Prompt
dialog box is displayed.
Run ping 192.168.0.72 to verify the network connection between the computer and
the BTS.
NOTE:
The IP address of the BTS is 192.168.0.72.
If the returned information is similar to that given in the example, the SMT PC and the
BBU can communicate normally.
Pinging 192.168.0.72 with 32 bytes of data:
Pinging 192.168.0.72 with 32 bytes of data:
Reply from 192.168.0.72: bytes=32 time=1ms TTL=253
Reply from 192.168.0.72: bytes=32 time=1ms TTL=253
Reply from 192.168.0.72: bytes=32 time=1ms TTL=253
Reply from 192.168.0.72: bytes=32 time=1ms TTL=253
Ping statistics for 192.168.0.72:
Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),
Approximate round trip times in milli-seconds:
Minimum = 1ms, Maximum = 1ms, Average = 1ms
Parent topic: Starting the Site Maintenance Terminal System
Prerequisites
Procedure
1.
2.
3.
The BTS should be support the function that need enter User Name and
Password information.
The default User Name and Password are both admin.
2016-05-23
Page2, Total4
Document Title
Security Level
If the SMT PC fails to communicate with the BTS, the Communication failed
dialog box is displayed, as shown in Figure 2. Go to 4.
2016-05-23
Page3, Total4
Document Title
4.
Security Level
Click Yes.
The Set Communication Port Parameter dialog box is displayed, as shown in Figure
3.
Figure 3 Set Communication Port Parameter dialog box
5.
In the Select Communication Port area, click Network Port. In the Configure IP
area, set the IP address to 192.168.0.72.
6.
Click OK.
The Site Maintenance Terminal System window is displayed, as shown in Figure 1.
2016-05-23
Page4, Total4