Sunteți pe pagina 1din 10

FT-8 MobilePac: 60Hz-13.

8kV, Liquid Fuel WI-42 & DRY


Notes Applicable to Performance and Emissions Data
Standard MobilePac Performance, Sea Level, 60% RH
CustCpy_StdMP_60-138_LF_MJ_R2-090911.xls
W A R N IN G -- T h i s d o c u m e n t c o n ta in s t e ch n ic a l d a ta t h e e x p o r t o f w h i c h is o r
m a y b e r e s tr ic te d b y t h e E x p o rt A d m in i s tra ti o n A c t a n d th e E x p o rt
A d m in is t ra ti o n R e g u l a t io n s ( E A R ), 1 5 C .F .R . p a rt s 7 3 0 - 7 7 4 . D i v e r s i o n c o n t r a r y
t o U . S . la w is p r o h i b i te d . T h e e x p o r t, re e x p o r t , t ra n s f e r o r r e -t ra n s f e r o f th is
t e c h n ic a l d a t a to a n y o th e r c o m p a n y , e n t it y, p e rs o n , o r d e s ti n a t io n , o r fo r a n y
u s e o r p u r p o s e o t h e r th a n th a t f o r w h i c h th e te c h n ic a l d a ta w a s o ri g i n a l ly p r o v i d e d
b y P & W , i s p r o h i b ite d w it h o u t p r io r w r i tte n a p p r o v a l fro m P & W a n d a u t h o r iz a tio n
u n d e r a p p l ic a b l e e x p o rt c o n t ro l la w s .
E A R E x p o rt C la s s if ic a ti o n : E C C N 9 E 9 9 1

Notes:
0. All Performance/Emissions Data submitted are subject to the sum of the following notes, and the most recent version of PWPS "Factory
and Field Tests" at the time of the proposal offering. Notes included herein shall supersede any notes in the Contract, Specifications,
Terms & Conditions to the contrary; and shall have the highest level of hierarchy in all related documents.
1. All data is presented on an estimated basis. Should a job progress to needing guaranteed values, then customer/site specific performance
shall be issued, with appropriate guarantee margins added. In addition, the following notes are being presented as our customary
practices related to performance and emissions guarantees.
2. The minimum operating compressor inlet temperature for the MobilePac is -58 deg F.
3. The minimum operating temperature the MobilePac package can be operated in is -40 deg F.
4. The MobilePac consists of one turbine (1-GT) driving one generator. Rates are shown as per MP.
5. Liquid fuel supplied to gas turbines must meet PWPS fuel specification FR-1.
6. Water used for burner injection must meet PWPS specification AR-1 (demin water).
7. DRY performance data is based on the standard combustor without water injection.
8. Water injected data is shown for liquid fuel WI-42 ppmvd NOx @ 15% O2.
9. All emission concentration data (ppmvd and/or mg/Nm3) are corrected to 15% O2, on a dry basis.
10. All data supplied based on sea level altitude and 60% relative humidity.
11. Inlet loss estimated at 2.5 in W.C. with 2-stage inlet filter. No correction of test results for inlet loss.
12. Exhaust loss for all cases estimated at 1.0 in W.C. for standard exhaust stack. There will be no correction of test results
for exhaust loss in simple-cycle.
13. Stack Exhaust Velocity based on Exhaust Gas Vol Flow Rate and Exhaust Exit Area (81.546 sq ft).
14. Secondary (enclosure) cooling air is mixed with primary exhaust flow, before stack exit.
15. Data designated as "primary exhaust" is referenced to the GT exhaust and does not include secondary (enclosure) cooling air.
16. All data submitted is based upon DBAX 62-170 generator operating at 60Hz and 0.9 power factor @ 13.8kV.
17. Net Power = Power measured at the generator terminals, minus auxiliary loads for power island.
18. GSU losses and BOP loads are not included in Net Power output or Net Heat Rate determinations.
19. Performance Acceptance Test for GT Net Power Output and GT Net Heat Rates to be conducted per PWPS test procedures,
instrumentation, and calculations; all being in general accordance with ASME PTC-22 and PTC-19.1. PWPS does not acknowledge
ISO 2314 for performance testing.
20. Performance acceptance testing for GT Net Power Output and GT Net Heat Rate shall be furnished by PWPS through independent
third party contractor.
21. Test boundary shall be LPC Inlet Temperature as defined by the average dry bulb temperature, at the inlet filter faces.
22. Site performance to be corrected for changes in LPC inlet temperature, ambient pressure, and relative/specific humidity.
23. Thermal performance tests must be conducted in "New & Clean" condition, with less than 100 fired-hours. If Units are dispatched for
Commercial Operation, or operated by Purchaser for more than 100 fired-hours, then thermal performance will
have been deemed to have been met, and any thermal performance testing would be conducted and reported as "Information Only".
24. While guarantees have been provided for multiple configurations (i.e. water injected vs. dry operation) per fuel, PWPS will only test
and be required to demonstrate Guaranteed performance for one configuration per fuel.
25. Approximately 60 days prior to performance testing of the units, Purchaser will be provided with correction curves for the GT power
and heat rate, as well as draft performance acceptance test procedures. Curves and procedures will not be issued with RFQ responses.
26. Emission data is representative of steady-state operation, and may not be indicative of emissions during transient operation.
Demonstration of (G) emission concentrations for NOx, CO and VOC's are based on 1-hour averages, after operation under steady-state
conditions for 1-hour. "Steady state" shall be defined as less than +/-2% variation from the average for power output, which is in
alignment for the PTC-22 (1997) gas turbine code for steady state conditions. Compliance with guarantees shall be based on the
average of stack traverse's.
27. Applications that utilize CEM systems, must use a multi-point, multiple probe system to read emissions concentrations in the backpass.
This averaging system is required to prevent emission compliance issues related to diluent stratification associated with the addition of
secondary (enclosure) cooling air, and the use of noise attenuation baffles in the stack.
28. Performance and emissions are based upon assumed fuel compositions shown on Sheet - 2. Significant changes from these
characteristics can change the performance and emissions quoted. PWPS reserves the option to correct performance for LHV/HCR.
29. SO2 data is estimated from Sulfur contents stated on Sheet - 2, which PWPS does not control and therefore can't guarantee.
30. Tested NOx concentrations shall be corrected lower for liquid fuel bound nitrogen (FBN) in excess of 0.015% by weight.
31. All emission measurements to be by US EPA methods. All emissions measurements for engine tuning, demonstration of emissions
guarantees and/or Air Permit compliance (and related procedures), to be furnished by Purchaser, and shall conform to PWPS
Quality Assurance procedure: "McHale PWPS EmissionsTuningQAProcedure 0001ETQAR2.pdf"
32. Volatile Organic Compounds (VOC) are defined as non methane, non ethane, with > 85% of the composition being ethene.
Values shown are based upon PWPS experience and measurement using EPA Method 25A (total UHC) on liquid fuel.
33. Testing for PM10 shall conform to PWPS Quality Assurance documentation in addition to EPA Reference Method 5 (filterable)
and R/M 202 (condensable/back half) fractions. Volumetric flow rate for determination of PM10 to be per EPA Method 19,
which utilized fuel flow, O2%, and F-factors.
34. Particulate samples shall be drawn isokinetically, with a minimum of 3-hour sample duration and are to consist of 3-tests.
35. Water and fuel samples must be taken during PM10 testing and be analyzed for conformance to FR-1, FR-2 and AR-1 specifications. If
sample results are outside of specification, any suspect PM10 test shall be rejected and retested at the expense of the customer.
36. In the event that the customer does not provide emissions measurements for tuning of water injection systems which meet the
requirements of the PWPS Emissions Quality Assurance document, then PWPS reserves the right to tune water/fuel ratios in
accordance with our default levels.
37. In the event that the customer does not conduct emissions testing for the verification of compliance with PWPS emissions guarantees,
or if such testing is not in accordance with PWPS Emissions Quality Assurance document, the achievement of substantial
completion of the project by PWPS shall not be delayed.
38. If future emissions tuning or testing are required after the initial commissioning period when staffed by PWPS personnel and/or
contractors, the additional mobilizations/demobilizations and provision of technical teams for the tuning and/or testing shall be at the
customers expense.
Sheet 1 of 6

FT-8 MobilePac: 60Hz-13.8kV, Liquid Fuel WI-42 & DRY


Assumed Fuel Properties
Standard MobilePac Performance, Sea Level, 60% RH

ECCN9E991

The following fuel properties are assumed as representative of site fuels in lieu of specified data.

Std. No.-2 Fuel Oil


Carbon
Hydrogen
Nitrogen
Oxygen
Sulfur Max
Total

Weight %
87.12
12.80
0.015
0.010
0.050
100.0

Units
Hydrogen to Carbon Ratio
Higher Heating Value
Lower Heating Value
Ratio HHV/LHV
Specific Gravity

CustCpy_StdMP_60-138_LF_MJ_R2-090911.xls
Sheet - 2

Btu/lb
kJ/kg
Btu/lb
kJ/kg

0.1470
19,553
45,480
18,360
42,705
1.065
0.816

FT-8 MobilePac: 60Hz-13.8kV, Liquid Fuel WI-42


Estimated Performance and Emissions, Base-Load Data
Standard MobilePac Performance, Sea Level, 60% RH

ECCN9E991

Configuration: Liquid Fuel WI-42 ppmvd NOx, DBAX 62-170 Generator,60 Hz, 13.8kV, 0.9Pf, Simple-Cycle.
Performance Data
Fuel Type
Number of GT's in Operation
Water Injection In-Service
Percent of MobilePac Rating
Compressor Inlet Temperature
Ambient Pressure
Relative Humidity
Inlet Loss
Exhaust Loss
Fuel LHV
Ratio of HHV to LHV
Gross Power Output per MP, ref Gen Term
Gross Heat Rate, LHV, ref Gen Term
Power Isle Aux Loads
Net Power Output
Net Heat Rate, LHV
Fuel Flow, per MP
Burner Water Injection Flow, per MP

No.
Yes / No
%
Deg F
Psia
%
Inch H20
Inch H20
Btu/lb

Liquid
1
Yes
100
-4.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
5.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
10.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
16.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
23.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
32.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
41.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
50.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
59.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
68.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
77.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
86.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
95.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
104.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
113.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
122.0
14.70
60.0
2.5
1.0
18,360
1.065

MWe
Btu/kWhr
kW
MWe
Btu/kWhr
lbs/hr
gal/min

28.448
9,185
172
28.276
9,241
14,232
28.0

28.464
9,231
172
28.292
9,287
14,311
28.7

28.451
9,258
172
28.279
9,315
14,347
29.1

28.486
9,290
172
28.314
9,346
14,413
29.7

28.497
9,327
172
28.325
9,384
14,477
30.3

28.511
9,379
172
28.339
9,436
14,564
31.1

27.922
9,451
172
27.750
9,509
14,373
31.0

26.109
9,589
172
25.937
9,653
13,636
29.4

25.095
9,702
172
24.923
9,769
13,261
28.8

24.068
9,829
172
23.896
9,899
12,884
28.2

23.029
9,966
172
22.857
10,041
12,501
27.5

22.054
10,110
172
21.882
10,190
12,144
26.9

21.169
10,255
172
20.997
10,339
11,824
26.4

20.271
10,414
172
20.099
10,503
11,497
25.9

19.385
10,586
172
19.213
10,681
11,177
25.3

18.602
10,764
172
18.430
10,864
10,905
24.8

42
50.5
24.8
18.2
5.0
2.09
9.57
15.93
18.00

42
50.8
22.7
16.7
5.0
2.10
9.57
16.02
18.00

42
50.1
21.5
15.6
5.0
2.08
9.55
15.81
18.00

42
47.6
21.8
15.0
5.0
1.97
9.52
15.00
18.00

42
46.2
20.9
14.0
5.0
1.91
9.49
14.59
18.00

42
44.9
20.0
13.0
5.0
1.86
9.44
14.17
18.00

42
43.6
19.3
12.2
5.0
1.80
9.40
13.75
18.00

42
42.4
18.6
11.4
5.0
1.75
9.35
13.36
18.00

42
41.2
17.9
10.7
5.0
1.71
9.31
13.01
18.00

42
40.1
17.4
10.1
5.0
1.66
9.26
12.65
18.00

42
39.0
16.9
9.6
5.0
1.61
9.21
12.29
18.00

42
38.0
16.3
9.0
5.0
1.58
9.16
12.00
18.00

262.9
665
28.70
7,524
92.3
5.54
15.53
3.19
0.89
74.8

259.5
684
28.67
7,557
92.7
5.81
15.40
3.25
0.89
74.7

254.9
698
28.65
7,521
92.2
6.02
15.33
3.27
0.89
74.5

246.8
704
28.63
7,324
89.8
6.12
15.38
3.21
0.89
74.4

241.2
716
28.60
7,237
88.7
6.40
15.33
3.20
0.88
74.2

235.7
728
28.56
7,154
87.7
6.77
15.26
3.20
0.88
73.9

230.1
740
28.51
7,066
86.6
7.24
15.18
3.19
0.87
73.5

224.7
752
28.44
6,986
85.7
7.85
15.06
3.18
0.87
73.0

219.5
764
28.35
6,914
84.8
8.64
14.91
3.17
0.86
72.4

214.4
775
28.24
6,843
83.9
9.64
14.71
3.16
0.85
71.6

209.2
786
28.11
6,769
83.0
10.88
14.47
3.15
0.84
70.7

204.5
797
27.93
6,719
82.4
12.46
14.15
3.14
0.83
69.4

Emissions & Exhaust Conditions at Stack Exit, After Addition of Secondary (Enclosure) Cooling Air*
NOx
ppmvd
42
42
42
42
NOx, as NO2, per MP
lbs/hr
49.6
49.9
50.0
50.2
CO
ppmvd
32.6
29.6
28.0
26.4
CO, per MP
lbs/hr
23.5
21.4
20.3
19.3
VOC as C1
ppmvd
5.5
5.0
5.0
5.0
VOC as C1, per MP
lbs/hr
2.25
2.07
2.07
2.08
SO2
ppmvd
9.57
9.57
9.56
9.57
SO2, per MP
lbs/hr
15.65
15.74
15.78
15.85
TSP/PM10, Filterable and Cond, per MP
lbs/hr
18.00
18.00
18.00
18.00
Exhaust Gas Flow, per MP **
Exhaust Gas Temperature **
Exhaust Gas Molecular Weight, Wet
Exhaust Gas Vol Flow Rate, per MP **
Stack Exhaust Exit Velocity, per MP **
H2O
O2
CO2
A
N2

lbs/sec
Deg F
ACFS
FPS
% Vol wet
% Vol wet
% Vol wet
% Vol wet
% Vol wet

273.7
608
28.74
7,422
91.0
4.94
15.88
3.02
0.90
75.3

270.0
627
28.73
7,457
91.4
5.12
15.77
3.08
0.89
75.1

268.1
638
28.72
7,476
91.7
5.22
15.71
3.11
0.89
75.1

265.7
650
28.71
7,499
92.0
5.36
15.62
3.15
0.89
75.0

* All concentrations corrected to 15% O2


** Secondary (Enclosure) Cooling Air Mixed with Primary Exhaust
All data are estimates.
CustCpy_StdMP_60-138_LF_MJ_R2-090911.xls

Sheet-3

FT-8 MobilePac: 60Hz-13.8kV, Liquid Fuel WI-42


Estimated Performance and Emissions, Part-Load Data
Standard MobilePac Performance, Sea Level, 60% RH

ECCN9E991

Configuration: Liquid Fuel WI-42 ppmvd NOx, DBAX 62-170 Generator,60 Hz, 13.8kV, 0.9Pf, Simple-Cycle.
Performance Data
Fuel Type
Number of GT's in Operation
Water Injection In-Service
Percent of MobilePac Rating
Compressor Inlet Temperature
Ambient Pressure
Relative Humidity
Inlet Loss
Exhaust Loss
Fuel LHV
Ratio of HHV to LHV
Gross Power Output per MP, ref Gen Term
Gross Heat Rate, LHV, ref Gen Term
Power Isle Aux Loads
Net Power Output
Net Heat Rate, LHV
Fuel Flow, per MP
Burner Water Injection Flow, per MP

No.
Yes / No
%
Deg F
Psia
%
Inch H20
Inch H20
Btu/lb

Liquid
1
Yes
100
23.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
95
23.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
85
23.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
75
23.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
65
23.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
50
23.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
59.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
95
59.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
85
59.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
75
59.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
65
59.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
50
59.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
100
86.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
95
86.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
85
86.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
75
86.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
65
86.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
Yes
50
86.0
14.70
60.0
2.5
1.0
18,360
1.065

MWe
Btu/kWhr
kW
MWe
Btu/kWhr
lbs/hr
gal/min

28.497
9,327
172
28.325
9,384
14,477
30.3

27.072
9,378
172
26.900
9,438
13,828
28.3

24.222
9,532
172
24.050
9,601
12,576
24.7

21.373
9,761
172
21.201
9,841
11,363
21.4

18.523
10,072
172
18.351
10,167
10,162
18.2

14.248
10,776
172
14.076
10,907
8,362
13.8

25.094
9,702
172
24.922
9,769
13,260
28.8

23.838
9,783
172
23.666
9,854
12,702
27.1

21.329
9,983
172
21.157
10,064
11,597
23.9

18.820
10,247
172
18.648
10,341
10,503
20.8

16.310
10,607
172
16.138
10,721
9,423
17.9

12.546
11,780
172
12.374
11,944
8,050
14.7

22.054
10,110
172
21.882
10,190
12,144
26.9

20.951
10,207
172
20.779
10,291
11,647
25.4

18.746
10,440
172
18.574
10,537
10,660
22.5

16.540
10,751
172
16.368
10,864
9,686
19.7

14.335
11,167
172
14.163
11,303
8,719
17.1

11.027
12,470
172
10.855
12,667
7,489
14.1

42
35.4
46.6
23.9
12.3
3.62
9.57
11.18

42
29.1
61.9
26.1
23.7
5.71
9.58
9.20

42
46.2
20.9
14.0
5.0
1.91
9.48
14.59

42
44.3
22.7
14.6
5.0
1.83
9.49
13.97

42
40.4
26.5
15.5
5.0
1.67
9.49
12.76

42
36.6
31.7
16.8
5.1
1.56
9.50
11.55

42
32.8
37.4
17.8
7.7
2.08
9.51
10.37

42
28.0
43.8
17.8
10.9
2.52
9.52
8.85

42
42.4
18.6
11.4
5.0
1.75
9.34
13.36

42
40.6
20.2
11.9
5.0
1.68
9.36
12.81

42
37.2
23.9
12.9
5.0
1.54
9.37
11.73

42
33.7
27.6
13.5
5.0
1.40
9.38
10.65

42
30.4
33.2
14.6
5.7
1.43
9.40
9.59

42
26.1
38.6
14.6
8.2
1.77
9.43
8.24

229.6
586
28.77
6,093
74.7
4.23
16.62
2.58
0.90
75.7

212.6
552
28.81
5,451
66.8
3.67
17.12
2.30
0.90
76.0

241.3
716
28.60
7,241
88.8
6.40
15.33
3.20
0.88
74.2

237.1
705
28.61
7,047
86.4
6.22
15.48
3.12
0.88
74.3

228.5
685
28.64
6,666
81.8
5.86
15.77
2.96
0.89
74.5

219.6
664
28.66
6,283
77.0
5.50
16.07
2.80
0.89
74.7

210.1
642
28.68
5,894
72.3
5.14
16.38
2.62
0.89
75.0

199.6
617
28.70
5,465
67.0
4.66
16.83
2.36
0.90
75.2

224.8
752
28.44
6,991
85.7
7.85
15.06
3.18
0.87
73.0

220.8
741
28.45
6,805
83.4
7.68
15.20
3.10
0.87
73.1

212.9
721
28.47
6,445
79.0
7.34
15.49
2.94
0.87
73.4

204.6
701
28.49
6,082
74.6
7.00
15.77
2.78
0.88
73.6

195.8
680
28.51
5,713
70.1
6.65
16.07
2.62
0.88
73.8

186.2
654
28.54
5,305
65.1
6.18
16.51
2.37
0.88
74.1

Emissions & Exhaust Conditions at Stack Exit, After Addition of Secondary (Enclosure) Cooling Air*
NOx
ppmvd
42
42
42
42
NOx, as NO2, per MP
lbs/hr
50.5
48.2
43.8
39.6
CO
ppmvd
24.8
27.1
32.8
38.6
CO, per MP
lbs/hr
18.2
18.9
20.8
22.1
VOC as C1
ppmvd
5.0
5.0
5.5
8.2
VOC as C1, per MP
lbs/hr
2.09
2.00
2.01
2.70
SO2
ppmvd
9.58
9.57
9.57
9.57
SO2, per MP
lbs/hr
15.92
15.21
13.83
12.50
Exhaust Gas Flow, per MP **
Exhaust Gas Temperature **
Exhaust Gas Molecular Weight, Wet
Exhaust Gas Vol Flow Rate, per MP **
Stack Exhaust Exit Velocity, per MP **
H2O
O2
CO2
A
N2

lbs/sec
Deg F
ACFS
FPS
% Vol wet
% Vol wet
% Vol wet
% Vol wet
% Vol wet

262.6
664
28.70
7,508
92.1
5.54
15.53
3.19
0.89
74.8

258.8
652
28.71
7,317
89.7
5.33
15.70
3.10
0.89
75.0

249.7
629
28.73
6,910
84.7
4.95
16.01
2.93
0.89
75.2

* All concentrations corrected to 15% O2


** Secondary (Enclosure) Cooling Air Mixed with Primary Exhaust
All data are estimates.
CustCpy_StdMP_60-138_LF_MJ_R2-090911.xls

Sheet-4

239.9
608
28.75
6,504
79.8
4.59
16.31
2.76
0.90
75.4

FT-8 MobilePac: 60Hz-13.8kV, Liquid Fuel - DRY


Estimated Performance and Emissions, Base-Load Data
Standard MobilePac Performance, Sea Level, 60% RH

ECCN9E991

Configuration: Liquid Fuel- Std. Combustor-DRY, DBAX 62-170 Generator,60 Hz, 13.8kV, 0.9Pf, Simple-Cycle.
Performance Data
Fuel Type
Number of GT's in Operation
Water Injection In-Service
Percent of MobilePac Rating
Compressor Inlet Temperature
Ambient Pressure
Relative Humidity
Inlet Loss
Exhaust Loss
Fuel LHV
Ratio of HHV to LHV
Gross Power Output per MP, ref Gen Term
Gross Heat Rate, LHV, ref Gen Term
Power Isle Aux Load
Net Power Output
Net Heat Rate, LHV
Fuel Flow, per MP
Burner Water Injection Flow, per MP

No.
Yes / No
%
Deg F
Psia
%
Inch H20
Inch H20
Btu/lb

Liquid
1
No
100
-4.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
5.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
10.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
16.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
23.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
32.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
41.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
50.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
59.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
68.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
77.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
86.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
95.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
104.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
113.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
122.0
14.70
60.0
2.5
1.0
18,360
1.065

MWe
Btu/kWhr
kW
MWe
Btu/kWhr
lbs/hr
gal/min

28.160
8,814
114
28.046
8,850
13,518
0.0

28.171
8,852
114
28.057
8,888
13,583
0.0

28.176
8,875
114
28.062
8,911
13,619
0.0

28.134
8,903
114
28.020
8,939
13,643
0.0

27.284
8,966
114
27.170
9,004
13,324
0.0

25.868
9,080
114
25.754
9,120
12,793
0.0

24.063
9,235
114
23.949
9,279
12,104
0.0

22.590
9,392
114
22.476
9,440
11,556
0.0

21.433
9,539
114
21.319
9,590
11,136
0.0

20.391
9,688
114
20.277
9,742
10,759
0.0

19.421
9,841
114
19.307
9,899
10,410
0.0

18.509
10,003
114
18.395
10,065
10,084
0.0

17.662
10,174
114
17.548
10,240
9,787
0.0

16.866
10,352
114
16.752
10,423
9,510
0.0

16.077
10,547
114
15.963
10,622
9,236
0.0

15.390
10,742
114
15.276
10,822
9,004
0.0

396
438.5
22.0
14.9
5.0
1.92
9.62
14.66
18.00

399
424.3
21.8
14.1
5.0
1.85
9.60
14.07
18.00

396
397.8
22.1
13.5
5.0
1.75
9.57
13.31
18.00

398
382.0
21.9
12.8
5.0
1.67
9.53
12.71
18.00

407
376.2
21.2
11.9
5.0
1.61
9.48
12.25
18.00

416
371.9
20.4
11.1
5.0
1.55
9.45
11.83
18.00

425
367.5
19.7
10.4
5.0
1.50
9.40
11.45
18.00

435
364.2
18.9
9.7
5.0
1.46
9.36
11.09
18.00

446
362.3
18.3
9.0
5.0
1.41
9.31
10.77
18.00

456
360.6
17.6
8.5
5.0
1.37
9.26
10.46
18.00

466
357.5
17.0
8.0
5.0
1.33
9.21
10.16
18.00

476
356.1
16.4
7.5
5.0
1.30
9.16
9.90
18.00

255.1
682
28.98
7,338
90.0
2.88
16.3
3.04
0.91
76.9

247.9
691
28.96
7,190
88.2
2.97
16.3
3.01
0.91
76.8

239.6
696
28.94
6,987
85.7
3.08
16.4
2.96
0.91
76.7

232.4
705
28.92
6,832
83.8
3.25
16.4
2.92
0.91
76.5

226.2
716
28.89
6,721
82.4
3.52
16.3
2.90
0.91
76.3

220.4
728
28.85
6,621
81.2
3.87
16.3
2.88
0.90
76.0

214.9
739
28.80
6,530
80.1
4.34
16.2
2.87
0.90
75.6

209.6
751
28.73
6,446
79.1
4.96
16.1
2.86
0.89
75.2

204.6
763
28.64
6,376
78.2
5.76
15.9
2.85
0.89
74.5

199.7
775
28.53
6,309
77.4
6.78
15.7
2.84
0.88
73.7

194.8
786
28.39
6,242
76.5
8.06
15.5
2.82
0.87
72.7

190.2
798
28.21
6,191
75.9
9.66
15.2
2.82
0.85
71.5

Emissions & Exhaust Conditions at Stack Exit, After Addition of Secondary (Enclosure) Cooling Air*
NOx
ppmvd
337
360
373
390
NOx, as NO2, per MP
lbs/hr
378.5
406.3
421.7
441.7
CO
ppmvd
27.9
25.4
24.1
22.6
CO, per MP
lbs/hr
19.0
17.5
16.6
15.6
VOC as C1
ppmvd
5.0
5.0
5.0
5.0
VOC as C1, per MP
lbs/hr
1.95
1.96
1.97
1.97
SO2
ppmvd
9.62
9.62
9.62
9.62
SO2, per MP
lbs/hr
14.87
14.94
14.98
15.01
TSP/PM10, Filterable and Cond, per MP
lbs/hr
18.00
18.00
18.00
18.00
Exhaust Gas Flow, per MP **
Exhaust Gas Temperature **
Exhaust Gas Molecular Weight, Wet
Exhaust Gas Vol Flow Rate, per MP **
Stack Exhaust Exit Velocity, per MP **
H2O
O2
CO2
A
N2

lbs/sec
Deg F
ACFS
FPS
% Vol wet
% Vol wet
% Vol wet
% Vol wet
% Vol wet

268.5
628
28.99
7,351
90.1
2.61
16.5
2.94
0.92
77.0

264.6
648
28.99
7,384
90.5
2.69
16.4
2.99
0.92
77.0

262.5
660
28.99
7,403
90.8
2.75
16.3
3.02
0.92
76.9

260.0
673
28.98
7,422
91.0
2.82
16.3
3.05
0.91
76.9

* All concentrations corrected to 15% O2


** Secondary (Enclosure) Cooling Air Mixed with Primary Exhaust
All data are estimates.
CustCpy_StdMP_60-138_LF_MJ_R2-090911.xls

Sheet-5

FT-8 MobilePac: 60Hz-13.8kV, Liquid Fuel - DRY


Estimated Performance and Emissions, Part-Load Data
Standard MobilePac Performance, Sea Level, 60% RH

ECCN9E991

Configuration: Liquid Fuel- Std. Combustor-DRY, DBAX 62-170 Generator,60 Hz, 13.8kV, 0.9Pf, Simple-Cycle.
Performance Data
Fuel Type
Number of GT's in Operation
Water Injection In-Service
Percent of MobilePac Rating
Compressor Inlet Temperature
Ambient Pressure
Relative Humidity
Inlet Loss
Exhaust Loss
Fuel LHV
Ratio of HHV to LHV
Gross Power Output per MP, ref Gen Term
Gross Heat Rate, LHV, ref Gen Term
Power Isle Aux Load
Net Power Output
Net Heat Rate, LHV
Fuel Flow, per MP
Burner Water Injection Flow, per MP

No.
Yes / No
%
Deg F
Psia
%
Inch H20
Inch H20
Btu/lb

Liquid
1
No
100
23.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
95
23.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
85
23.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
75
23.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
65
23.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
50
23.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
59.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
95
59.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
85
59.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
75
59.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
65
59.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
50
59.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
100
86.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
95
86.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
85
86.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
75
86.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
65
86.0
14.70
60.0
2.5
1.0
18,360
1.065

Liquid
1
No
50
86.0
14.70
60.0
2.5
1.0
18,360
1.065

MWe
Btu/kWhr
kW
MWe
Btu/kWhr
lbs/hr
gal/min

27.284
8,966
114
27.170
9,004
13,324
0.0

25.920
9,031
114
25.806
9,071
12,750
0.0

23.192
9,207
114
23.078
9,252
11,629
0.0

20.463
9,448
114
20.349
9,501
10,531
0.0

17.735
9,772
114
17.621
9,836
9,440
0.0

13.642
10,507
114
13.528
10,595
7,807
0.0

21.433
9,539
114
21.319
9,590
11,136
0.0

20.361
9,640
114
20.247
9,694
10,691
0.0

18.218
9,881
114
18.104
9,944
9,805
0.0

16.075
10,201
114
15.961
10,274
8,932
0.0

13.932
10,619
114
13.818
10,707
8,058
0.0

10.717
11,883
114
10.603
12,011
6,936
0.0

18.509
10,003
114
18.395
10,065
10,084
0.0

17.584
10,125
114
17.470
10,192
9,697
0.0

15.733
10,415
114
15.619
10,491
8,924
0.0

13.882
10,787
114
13.768
10,877
8,156
0.0

12.031
11,620
114
11.917
11,732
7,615
0.0

9.255
12,683
114
9.141
12,841
6,393
0.0

255
199.2
42.9
20.4
10.4
2.83
9.61
10.38

208
134.2
58.0
22.8
20.5
4.62
9.61
8.59

407
376.2
21.2
11.9
5.0
1.61
9.48
12.25

384
340.6
23.1
12.5
5.0
1.54
9.49
11.76

345
280.3
27.1
13.4
5.0
1.41
9.49
10.79

307
227.5
32.4
14.6
5.4
1.39
9.50
9.82

274
182.9
38.3
15.6
8.1
1.88
9.51
8.86

246
141.2
45.3
15.8
11.7
2.33
9.52
7.63

435
364.2
18.9
9.7
5.0
1.46
9.36
11.09

413
332.4
20.7
10.1
5.0
1.40
9.37
10.67

370
274.2
24.4
11.0
5.0
1.29
9.38
9.82

333
225.2
28.5
11.7
5.0
1.18
9.40
8.97

327
206.1
29.5
11.3
5.0
1.10
9.41
8.38

267
141.5
39.6
12.8
8.7
1.61
9.44
7.03

224.0
597
28.97
5,966
73.2
2.37
17.2
2.47
0.92
77.1

208.1
560
28.96
5,348
65.6
2.14
17.6
2.20
0.92
77.2

226.2
716
28.89
6,721
82.4
3.52
16.3
2.90
0.91
76.3

222.6
705
28.89
6,554
80.4
3.45
16.4
2.83
0.91
76.3

215.2
684
28.89
6,218
76.3
3.33
16.7
2.69
0.91
76.4

207.3
663
28.88
5,880
72.1
3.20
16.9
2.54
0.91
76.4

198.9
641
28.88
5,534
67.9
3.07
17.1
2.39
0.91
76.5

189.8
614
28.88
5,152
63.2
2.87
17.5
2.16
0.91
76.6

209.6
751
28.73
6,446
79.1
4.96
16.1
2.86
0.89
75.2

206.3
741
28.73
6,292
77.2
4.90
16.2
2.79
0.89
75.2

199.4
720
28.72
5,979
73.3
4.79
16.4
2.65
0.90
75.2

192.2
700
28.72
5,662
69.4
4.67
16.6
2.52
0.90
75.3

189.1
688
28.72
5,517
67.7
4.55
16.8
2.38
0.90
75.3

176.3
651
28.72
4,976
61.0
4.35
17.2
2.15
0.90
75.4

Emissions & Exhaust Conditions at Stack Exit, After Addition of Secondary (Enclosure) Cooling Air*
NOx
ppmvd
396
370
328
289
NOx, as NO2, per MP
lbs/hr
438.5
391.9
316.5
252.1
CO
ppmvd
22.0
24.4
29.2
35.5
CO, per MP
lbs/hr
14.9
15.7
17.2
18.8
VOC as C1
ppmvd
5.0
5.0
5.0
6.7
VOC as C1, per MP
lbs/hr
1.92
1.84
1.68
2.03
SO2
ppmvd
9.62
9.61
9.61
9.61
SO2, per MP
lbs/hr
14.66
14.03
12.79
11.58
Exhaust Gas Flow, per MP **
Exhaust Gas Temperature **
Exhaust Gas Molecular Weight, Wet
Exhaust Gas Vol Flow Rate, per MP **
Stack Exhaust Exit Velocity, per MP **
H2O
O2
CO2
A
N2

lbs/sec
Deg F
ACFS
FPS
% Vol wet
% Vol wet
% Vol wet
% Vol wet
% Vol wet

255.1
682
28.98
7,338
90.0
2.88
16.3
3.04
0.91
76.9

251.2
669
28.97
7,144
87.6
2.80
16.4
2.96
0.91
76.9

242.7
644
28.97
6,753
82.8
2.66
16.7
2.80
0.92
76.9

233.6
621
28.97
6,362
78.0
2.52
16.9
2.63
0.92
77.0

* All concentrations corrected to 15% O2


** Secondary (Enclosure) Cooling Air Mixed with Primary Exhaust
All data are estimates.
CustCpy_StdMP_60-138_LF_MJ_R2-090911.xls

Sheet-6

Plot_Gross Power
E. Standard Performances- CustCpy_StdMP_60-138_LF_MJ_R2-090911.xls

Pratt and Whitney

Figure 11005, 09/09/2011


Standard MobilePac Performance
Estimated "Base Load" Gross Power Output vs Compressor Inlet Temperature
FT8 MobilePac, 60Hz-13.8kV-0.9Pf, Liquid Fuel-WI42 & DRY
Sea Level, 60% RH, 2.5 in W.C. Inlet Loss, 1.0 in Exhaust Loss

ECCN9E991

35

HEP 23697

MWGENLIM_0.9Pf

Est. Gross Power Output per MP, ref Gen Term (MW)

33

Gross Power_LF-WI42
Gross Power_LF-DRY

31

29

27

25

23

21

19

Note: Gross Power Output is based upon


output measured at the generator terminals.

17

15
-10

10

20

30

40

50

60

70

80

Compressor Inlet Temperature , deg F

90

100

110

120

130

Plot_Gross Heat Rate


E. Standard Performances- CustCpy_StdMP_60-138_LF_MJ_R2-090911.xls

Pratt and Whitney

Figure 11006, 09/09/2011


Standard MobilePac Performance
Estimated "Base Load" Gross Heat Rate (LHV) vs Compressor Inlet Temperature
FT8 MobilePac, 60Hz-13.8kV-0.9Pf, Liquid Fuel-WI42 & DRY
Sea Level, 60% RH, 2.5 in W.C. Inlet Loss, 1.0 in Exhaust Loss

ECCN9E991

10,900

Liquid Fuel LHV = 18,360 Btu/lb

Gross Heat Rate_LF-WI42

Est. Gross Heat Rate, LHV, ref Gen Term (Btu/kWhr)

10,700

Gross Heat Rate_LF-DRY

10,500
10,300
10,100
9,900
9,700
9,500
9,300
9,100
8,900
8,700
-10

10

20

30

40

50

60

70

80

Compressor Inlet Temperature , deg F

90

100

110

120

130

Plot_Net Power
E. Standard Performances- CustCpy_StdMP_60-138_LF_MJ_R2-090911.xls

Pratt and Whitney

Figure 11007, 09/09/2011


Standard MobilePac Performance
Estimated "Base Load" Net Power Output vs Compressor Inlet Temperature
FT8 MobilePac, 60Hz-13.8kV-0.9Pf, Liquid Fuel-WI42 & DRY
Sea Level, 60% RH, 2.5 in W.C. Inlet Loss, 1.0 in Exhaust Loss

ECCN9E991

29
Net Power_LF-WI42
Net Power_LF-DRY

Est. Net Power Output, per MP (MW)

27

25

23

21

19

17
Net Power Output = Gross Power Output at generator terminal - PI Aux Load

15
-10

10

20

30

40

50

60

70

80

Compressor Inlet Temperature , deg F

90

100

110

120

130

Plot_Net Heat Rate


E. Standard Performances- CustCpy_StdMP_60-138_LF_MJ_R2-090911.xls

Pratt and Whitney

Figure 11008, 09/09/2011


Standard MobilePac Performance
Estimated "Base Load" Net Heat Rate (LHV) vs Compressor Inlet Temperature
FT8 MobilePac, 60Hz-13.8kV-0.9Pf, Liquid Fuel-WI42 & DRY
Sea Level, 60% RH, 2.5 in W.C. Inlet Loss, 1.0 in Exhaust Loss

ECCN9E991

10,900

Liquid Fuel LHV = 18,360 Btu/lb

Net Heat Rate_LF-WI42

10,700

Net Heat Rate_LF-DRY

Est. Net Heat Rate - LHV (Btu/kWhr)

10,500
10,300
10,100
9,900
9,700
9,500
9,300
Note: Net Power Output and Net Heat Rates are based upon output
measured at the generator terminals, minus power island aux. loads.

9,100
8,900
8,700
-10

10

20

30

40

50

60

70

80

Compressor Inlet Temperature , deg F

90

100

110

120

130

S-ar putea să vă placă și