Quiz on Power System Study

1. Which of the following is not the source of short circuit current?


A.
B.
C.
D.

Generator
Transformer
Induction Motor
None of these.

2. Which of the following unsymmetrical fault is series fault?


A.
B.
C.
D.

LLG
Two phase open fault
Line to ground fault
None of these.

3. Which of the following statement is correct for series reactor?


A.
B.
C.
D.

It limits the voltage of the system


It limits the normal load current of the system
It limits the current during fault
It limits the rate of change of voltage during fault

4. If unbalanced current phasor having phase sequence RYB in clockwise direction, is


resolved into three balanced current pahsors then which of the statement is correct?
A.
B.
C.
D.

In positive phase sequence phasor, Y current phasor lags R current phasor by 120o
In positive phase sequence phasor, Y current phasor leads R current phasor by 120o
In negative phase sequence phasor, Y current phasor lags R current phasor by 120o
None of these

5. What may be consequence of short circuit fault in the near by network:


A.
B.
C.
D.

Voltage dip
Loss of Machine synchronization
Disturbance in dynamic stability
All the above

Page 1 of 3

6. Time for operation of a relay based on IEC Standard Inverse curve is equal to:
A.
B.
C.
D.

TMS x [1.4/ ((I/Ir) .02 1)]


TMS x [0.14/ ((I/Ir) .02 1)]
[1.4/ ((I/Ir) .02 1)]
TMS x [14/ ((I/Ir) .02 1)]

7. Two 132/33 kV transformers of same %age impedance are running in parallel. MVA
rating of Transformer-1 is 100 MVA and that of Transformer-2 is 50 MVA. At the time
of three phase fault in 33kV side, in what ratio transformers will share the fault current?
A.
B.
C.
D.

1:2
2:1
1:1
None of these.

8. Maximum fault current in LT side of any transformer:


A.
B.
C.
D.

Proportional to age impedance of that transformer


Inversely proportional to age impedance of that transformer
Equal to age impedance of that transformer
No relation with age impedance of that transformer

9. If loads are not balanced then which of the following study is applicable for load flow?
A. Single phase load flow study
B. Three phase load flow study
C. Both
10. If a 132/33kV transformer is connected in parallel with another 132/33kV transformer
then fault level of 33kV bus will:
A. Increase
B. Decrease
C. Remain same.
11. If a 132/33kV transformer is connected in parallel with another 132/33kV transformer
then fault level of 132 kV bus will:
A. Increase
B. Decrease
C. Remain same.

Page 2 of 3

12. Etap software is used for:


A.
B.
C.
D.

Load flow study


Short Circuit study
Transient stability study
All of above

13. Power Plot software is used for:


A.
B.
C.
D.

Relay characteristic
Short Circuit study
Transient stability study
All of above

Page 3 of 3