2.

Specification
2-1. GSM General Specification

G S M 85 0

E G S M 9 00

DCS1800

PCS1900

WCDMA
21 0 0

WCDMA
90 0

W C MD A
85 0

WCDMA
19 0 0

F r e q.
B a n d[ M H z ]
Uplink/
D o wn l i n k

8 2 4 ~ 8 49
8 6 9 ~ 8 94

880~915
925~960

1 7 1 0 ~ 1 7 85
1 8 0 5 ~ 1 8 80

1 8 5 0 ~ 1 9 10
1 9 3 0 ~ 1 9 90

1 9 2 2 ~ 1 9 77
2 1 1 2 ~ 2 1 67

880~915
925~960

824~849
869~894

1 8 5 2 ~ 1 9 07
1 9 3 2 ~ 1 9 87

A R FC N
range

1 2 8 ~ 2 51

0 ~ 1 24 &
9 7 5 ~ 1 0 23

512~885

512~810

U L:
9 6 1 2 ~ 9 8 88
D L:
10 5 6 2 ~ 1 0 83 8

U L:
2 7 1 2 ~ 2 8 63
D L:
2 9 3 7 ~ 3 0 88

U L:
4 1 3 2 ~ 4 2 33
D L:
4 3 5 7 ~ 4 4 58

U L:
9 6 1 2 ~ 9 8 88
D L:
10 5 6 2 ~ 1 0 83 8

T x /R x
spacing

4 5 MH z

4 5 MH z

9 5 MH z

8 0 MH z

1 9 0 MH z

4 5 MH z

4 5 MH z

8 0 MH z

Mod. Bit
rate/
B i t P e r i od

2 7 0. 8 3 3 k b ps
3 . 6 9 2u s

2 7 0 .8 3 3 k b p s
3 . 6 9 2u s

2 7 0 .8 3 3 k b p s
3 . 6 9 2u s

2 7 0 .8 3 3 k b p s
3 . 6 9 2u s

3 .8 4 M c p s

3 .8 4 M c p s

3 .8 4 M c p s

3 .8 M c p s

Time Slot
P er i o d /
F ra m e
Period

5 7 6 . 9u s
4 . 6 1 5m s

5 7 6 . 9u s
4 . 6 1 5m s

5 7 6 . 9u s
4 . 6 1 5m s

5 7 6 . 9u s
4 . 6 1 5m s

F r a me L e n g th :
10ms
S l ot l e n g t h:
0 . 6 6 7m s

F r a me L e n g th :
10ms
S l ot l e n g t h:
0 . 6 6 7m s

F r a me L e n g th :
10ms
S l ot l e n g t h:
0 . 6 6 7m s

F r a me L e n g th :
10ms
S l ot l e n g t h:
0 . 6 6 7m s

M o d ul a t i o n

0 .3 G M S K

0 .3 G M S K

0 .3 G M S K

0 .3 G M S K

QPSKHQPSK

QPSKHQPSK

QPSKHQPSK

QPSKHQPSK

M S P owe r

3 3 dB m ~ 5 dB m

3 3 dB m ~ 5 dB m

3 0 dB m ~ 0 dB m

3 0 dB m ~ 0 dB m

24dBm~
-5 0 d B m

24dBm~
-5 0 d B m

24dBm~
-5 0 d B m

24dBm~
-5 0 d B m

P owe r C l a s s

5 p c l ~ 1 9 pc l

5pcl ~ 19pcl

0pcl ~ 15pcl

0pcl ~ 15pcl

3(max+24dBm)

3(max+24dBm)

3(max+24dBm)

3(max+24dBm)

Sensitivity

-1 0 2 d B m

-1 0 2 d B m

-1 0 0 d B m

-1 0 0 d B m

- 10 6 . 7 d B m

- 10 6 . 7 d B m

- 10 6 . 7 d B m

- 10 6 . 7 d B m

TDMA Mux

Cell Radius

3 5K m

35Km

2Km

2Km

2Km

2Km

2Km

2Km

2-1

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

Specification

2-2. GSM Tx Power Class


TX Power
control

TX Power
GSM850

level

control

TX Power
EGSM900

control

level

TX Power
DCS1800

level

control

PCS1900

level

332 dBm

332 dBm

303 dBm

303 dBm

312 dBm

312 dBm

283 dBm

283 dBm

292 dBm

292 dBm

263 dBm

263 dBm

272 dBm

272 dBm

243 dBm

243 dBm

252 dBm

252 dBm

223 dBm

223 dBm

10

232 dBm

10

232 dBm

203 dBm

203 dBm

11

212 dBm

11

212 dBm

183 dBm

183 dBm

12

192 dBm

12

192 dBm

163 dBm

163 dBm

13

172 dBm

13

172 dBm

143 dBm

143 dBm

14

152 dBm

14

152 dBm

124 dBm

124 dBm

15

132 dBm

15

132 dBm

10

104 dBm

10

104 dBm

16

113 dBm

16

113 dBm

11

84 dBm

11

84 dBm

17

93dBm

17

93dBm

12

64 dBm

12

64 dBm

18

73 dBm

18

73 dBm

13

44 dBm

13

44 dBm

19

53 dBm

19

53 dBm

14

25 dBm

14

25 dBm

15

05 dBm

15

05 dBm

2-2

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

Specification

2-3. LTE General Specification

LTE Ban d1

LTE Ba nd3

LTE Ba nd5

LTE Ba nd7

LTE Ba nd8

LTE Ban d20

Fr eq .
B an d[ M Hz]
U p li nk/
Dow nli nk

19 20~ 198 0
21 10~ 217 0

1 710 ~178 5
1 805 ~188 0

824 ~849
869 ~894

2 500 ~257 0
1 805 ~188 0

8 80~ 914 .9
9 25~ 959 .9

832 ~862
791 ~821

ARFCN
r a nge

UL:
180 00~ 185 99
DL:
0~5 99

UL:
19 200 ~199 50
DL:
1 805 ~188 0

UL:
20 400 ~206 49
DL:
2 400 ~264 9

UL:
2 500 ~257 0
DL:
2 620 ~269 0

UL:
21 450 - 217 99
DL:
3 450 - 379 9

UL:
24 150 ~244 50
DL:
6150 ~645 0

Tx/Rx
sp acing

19 0M Hz

95 MHz

45 MHz

12 0M Hz

45M HZ

- 41M Hz

Cha nnel
Ba nd wi dt h

5 /10/1 5/20 MH z

1 . 4/3/5 /10/1 5/20


MHz

1. 4/3/5 /10 M Hz

5 /10/1 5/20 MHz

1. 4/3/5 /10M Hz

5 /10/1 5/20 MHz

M od ul ati o n

QPS K , 16 /64QAM

QPS K , 16 /64QAM

QPS K , 16 /64QAM

QPS K , 16 /64QAM

Q PS K , 16 /64QAM

QPS K , 16 /64QAM

MS Pow er
( M PR )

-3 5~ 25 . 7 dB m

-35~25. 7 d Bm

-3 5~2 5. 7 d Bm

-35~25. 7 d Bm

-3 5~2 5. 7 d Bm

-35~25. 7 d Bm

S ens i t i v i t
( QPS K )
( B W 1 0M Hz)

-9 4 dB m

- 92 dB m

-9 2 d Bm

- 95 dB m

- 95 dB m

- 94 dB m

Cel l Ra di us

> 5 Km

> 5 Km

> 5 Km

> 5 Km

> 5 Km

> 5 Km

2-3

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

3. Operation Instruction and Installation


Main Function
Phone (Dialer)
Contacts
Messaging
Samsung Apps
Calculator
Calendar
Camera
Clock
Email
Gallery
Internet
Memo
Mini diary
Music Player
My files
Settings
ThinkFree
Video player
Voice recorder
Widget
Picture frame
Widget
Days
Widget
Buddies now
Widget
Email
Widget
Dual clock

3-1

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

9. Reference Abbreviate
Reference Abbreviate
AAC: Advanced Audio Coding.
AVC : Advanced Video Coding.
BER : Bit Error Rate
BPSK: Binary Phase Shift Keying
CA : Conditional Access
CDM : Code Division Multiplexing
C/I : Carrier to Interference
DMB : Digital Multimedia Broadcasting
EN : European Standard
ES : Elementary Stream
ETSI: European Telecommunications Standards Institute
MPEG: Moving Picture Experts Group
PN : Pseudo-random Noise
PS : Pilot Symbol
QPSK: Quadrature Phase Shift Keying
RS : Reed-Solomon
SI : Service Information
TDM : Time Division Multiplexing
TS : Transport Stream

9-1

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

1. Safety Precautions
1-1. Repair Precaution
Before attempting any repair or detailed tuning, shield the device from RF noise or static
electricity discharges.
Use only demagnetized tools that are specifically designed for small electronic repairs,
as most electronic parts are sensitive to electromagnetic forces.
Use only high quality screwdrivers when servicing products. Low quality screwdrivers can
easily damage the heads of screws.
Use only conductor wire of the properly gauge and insulation for low resistance, because of
the low margin of error of most testing equipment.
We recommend 22-gauge twisted copper wire.
Hand-soldering is not recommended, because printed circuit boards (PCBs) can be easily
damaged, even with relatively low heat. Never use a soldering iron with a power rating of
more than 100 watts and use only lead-free solder with a melting point below 250C (482F).
Prior to disassembling the battery charger for repair, ensure that the AC power is disconnected.
Always use the replacement parts that are registered in the SEC system. Third-party replac
ement parts may not function properly.

1-1

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

Safety Precautions

1-2. ESD(Electrostatically Sensitive Devices) Precaution


Many semiconductors and ESDs in electronic devices are particularly sensitive to static discha
rge and can be easily damaged by it. We recommend protecting these components with cond
uctive anti-static bags when you store or transport them.
Always use an anti-static strap or wristband and remove electrostatic buildup or dissipate
static electricity from your body before repairing ESDs.
Ensure that soldering irons have AC adapter with ground wires and that the ground wires are
properly connected.
Use only desoldering tools with plastic tips to prevent static discharge.
Properly shield the work environment from accidental electrostatic discharge before opening
packages containing ESDs.
The potential for static electricity discharge may be increased in low humidity environments,
such as air-conditioned rooms. Increase the airflow to the working area to decrease the
chance of accidental static electricity discharges.

1-2

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

6. Level 1 Repair
6-1. S/W Download
6-1-1. Pre-requsite for S/W Downloading
- Diagram of connection

Data Cable

Mobile Phone(with Battery)

PC

6-1-2. How to download S/W


1) Downloading Binary Files
Binary file for downloadingI739.
cpall_XXXX.rom: this is the code binary file.
(file size is about 40MB)
2) Pre-requidsite for Downloading
Downloader Program (Odin3.exe)
I739 Mobile Phone
Data Cable
Binary file
3) Boot the mobile phone by pressing home key + PWR key + Voice down key at the same
time, If you do properly, you can see the some message on the main LCD, such as the
following so to say.
USB DLOAD
VIA CHEKER BOOT
FIxx 11:05:08

6-1

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

Level 1 Repair

4) Load the binary download program by executing the (Odin3.exe)

5) Press "PIT" button described in below picture to open the phone software.
Then select "ARUBA_DUOS_XXX.pit"from the file directory.

6-2

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

Level 1 Repair

6) Press "Bootloader" button described in below picture to open the phone software
and select "BOOTLOADER_I739KEALJ3_XXX.md5"from the file directory.

7) Press "PDA" button described in below picture to open the phone software
and select "CODE_I739KEALJ3_XXX.md5"from the file directory.

6-3

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

Level 1 Repair

8)

Press "PHONE" button described in below picture to open the phone software

and select "MODEM_I739KEALJ3_XXX.md5"from the file directory.

9) Press "CSC" button described in below picture to open the phone software
and select "csc_I739KEALJ3_XXX.md5"from the file directory.

6-4

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

Level 1 Repair

10) Now press the button start to download the software.

11) Well done. It's time to enjoy a break while waiting for the downloading.
After finishing the phone binary download, the Odin3 will show Pass, then download is
completed.
[Option]
If you need rebuild again, you can rebuild using home key + Power on + voice
down after finished downloading.
Caution. Do not disconnect during the S/W downloading.

6-5

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

Level 1 Repair

6-2. Calibration
6-2-1. Pre-requsite for calibration
- Diagram of connection

GPIB

Power Supply

Cable

(E3632A)
Adapter

Power

Serial
Cable

Supply
GPIB Cable
Cable

PC
Anyway
Jig
IF Cable
RF

HP8960 or

Cable

CMU200

Mobile
Phone

- Service Parts
Anyway Jig

Adaptor

GH99-36900B

ETA0U42CBC

IF Cable

RF Cable

GH39-01290A

GH39-00985A

- Standard Parts
Power Supply Cable

Serial Cable

GPIB Cable

- HP8960 has to be satisfied the condition like below to do calibration.


Option list

E1968A-202

GSM & EDGE mobile test application


6-6

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

Level 1 Repair

upgrade need
Phase & Ampl vs Time

Firmware

Hardware

GSM Polar cal option


(WCDMA - Qualcomm solution)

CDMA2000 TA

CDMA2000 mobile test

E1968A A.06.56

GSM/GPRS/EDGE

E1987A Fast switching A.06.19 GSM/GPRS/EDGE/WCDMA/HSDPA/CDMA2000


E1962B B.10.11

IS-2000/IS-95/AMPS

002

002 RF source 2

003

003 Flexible radio

6-7

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

Level 1 Repair

Firmware

Select this menu for details

License status summary

GSM
WCDMA
CDMA

Phase & Ampl vs Time Option


GSM Polar Cal Option(WCDMA - Qualcomm Solution),
If no option, it is impossible to do GSM EDGE cal of WCDMA.
(GSM Tx Power error)

6-8

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

Level 1 Repair

- CMU200 has to be satisfied the condition like below to do calibration.


H/W Option
Option No.

Option Name

CMU200

Main Frame

CMU-B11/B12

OCXO

Option Description
Need to have one of those.
It may needed when the DUT based on

CMU-B21(v14)

Universal Signaling AGERE chipset, because it need a live for


Unit

GSM, it need CMU-B54(v14).


BCH signal for Calibration. To working

GSM/
EGPRS

This is daughter board for GSM Signaling.

CMU-B54(v14)*

It's attached on the B21(v14).


Support DSP measurement, and also works

GPRS/

as a buffer. It needed to support support up


CMU-U65(v04)

DSP for Wideband


Measurement

to 128 steps, CMU-U65(v04) support up to


500 steps.
Dynamic Power" Calibration. In case of
"Polar Modulation" CMU-U65(v02) only
"Polar Modulation" test and "EDGE

CMU200

Main Frame

CMU-B11/B12

OCXO

Need to have one of those.


It may needed when the DUT based on

CMU-B21(v14)

Universal Signaling AGERE chipset, because it need a live for


Unit

GSM, it need CMU-B54(v14).

WCDMA/
GSM/
EGPRS
GPRS/

BCH signal for Calibration. To working


CMU-B66**
CMU-B68

Versatile Baseband Baseband board for UL, but it's now


Unit (Tx)

included in CMU-B68. So no longer exist.

Versatile Baseband
Unit (Tx + Rx)

Baseband board for WCDMA UL/DL


Support DSP measurement, and also works

CMU-U65(v04)***

DSP for Wideband as a buffer. It needed to support "Polar


Measurement

Modulation" test and "EDGE Dynamic


Power" Calibration.

S/W Option
GSM/

Option No.

Option Name

Option Description

CMU-K21*

GSM900-MS

Signaling SW for GSM 900 Band


6-9

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

Level 1 Repair

GPRS/

CMU-K22*

GSM1800-MS

Signaling SW for GSM 1800 Band

EGPRS

CMU-K23*

GSM1900-MS

Signaling SW for GSM 1900 Band

CMU-K24*

GSM850-MS

Signaling SW for GSM 850 Band

CMU-K48

IQvsSlot

SW support "Polar Modulation Calibration"

WCDMA/
GSM/

CMU-K65

GPRS/
EGPRS

WCDMA-UE : Txtests(3GPP/FDD)

SW support Tx Measurement of WCDMA

WCDMA-UE : DLCMU-K66

Generator(3GPP/F

SW Support DL Generator for WCDMA.

DD)
*These options were needed because some old phones needed to have a live BCH to do a
Rx Calibration(AFC and AGC).
**CMU-B66 may can be found at the HW option list. But this option is no longer exist,
because it's now included in the option CMU-B68, only in case of very old CMU200 which
supporting the WCDMA Testing.
***CMU-U65 has 2 kind of revision. The difference is the amount of buffer memory inside.
This influence to the "Polar Modulation Calibration" test, in case of CMU-U65(v02) only
supports up to 128 steps of test, CMU-U65(v04) supports up to 500 Steps. Currently
Samsung UMTS calibration doing that with about 300 steps, so it requires CMU-U65(v0.4)
6-2-2. How to do calibration
1) Download the the latest calibration program from anysvc, and unpack the .zip file in
the same folder.
- SCH-I699_RFCAL_VXXX.exe
- SCH-I699_RFCAL_VXXX.zip
2) Check solution and the relay control switch setting of anyway jig.
- Solution switch : 4
No

Solution

NXP Swift, Broadcom

- Relay control switch : all switches must be turn off.

6-10

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

Level 1 Repair

Solution Switch

Relay Control Switch

3) Run the execution file(.exe).


- SCH-I699_RFCAL_VXXX.exe
4) Setting the Config Test
Select a final calibration program version.
Select "PBA SKIP"
Select "End Mode", enter the channel "2XXXX". (eg. 20283)
Click the button, 'OK'.

6-11

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

Level 1 Repair

5) Write the "PCB Version" and "ROM Version "and click "VERSION SET" button.
After ,you click "Auto/Manual" button when the button changed to be available.

6-12

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

Level 1 Repair

6) Connect a mobile phone, The calibration is progressed automatically.

6-13

Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsungs written authorization is strictly prohibited.

Level 1 Repair

8) If the calibration is completed rightly, it shows the content, 'PASS'.

6-14