Documente Academic
Documente Profesional
Documente Cultură
1. Introduction
Wireless Communication Frequency
Wireless Communication Distance
Wireless Communication Rate
Display
Division
Serial Interface
Connect by RS232
Weight Unit
Decimal System/Hexadecimal System
External AC Adapter
Rechargeable Internal Battery
Operating Temperature
Storage Temperature
Relative Humidity
Dimensions
Weight
Version
430 MHz
30M/1500M (optional)
9600bps
XK315A1W: 6-digit 0.8 inches red LED
XK315A1GB-W: 6-digit 0.8 inches green LED
XK315A1GB-5-W: 6-digit 0.8 inches green LED
1/2/5/10/20/50/0.1/0.2/0.5/0.01/0.02/0.05/0.001/0.002/0.005
RS232 interface with continuous data output
Baud rate 1200, 2400, 4800, 9600
Optional RS485 interface
Display, computer, printer, etc.
kg/lb/UU (user unit should be set in factory)
lb and UU can be in two systems
100-240VAC 50/60Hz
6V/4AH
10 C to +40 C
25 C to +55 C
10% to 85% non-condensing
XK315A1W: 220140130 (mm)
XK315A1GB-W: 260222161 (mm)
XK315A1GB-5-W: 26516258 (mm)
2kg
VER 22.0
2. Wireless Connection
Note: One wireless indicator only can connect with one wireless weighing transmitter, and both
wireless communication frequencies should be same. Wireless communication frequencies are set in
factory and user cannot change. Regular wireless communication frequency is 430MHz
If user wants to use two or more than two set of wireless weighing indicator and wireless weighing
transmitter, wireless communication frequencies must be different. Please let salesman know and
wireless communication frequencies will be set in factory.
1. Connect wireless weighing transmitter with load cell.
2. Switch on wireless weighing transmitter until the wireless function works.
3. Switch on wireless weighing indicator and calibrate.
4. In configuration mode, set Con to Con=78.
5. When indicator wireless lamp flashes, wireless weighing transmitter and wireless weighing indicator
are connecting.
6. Then, to calibrate wireless weighing indicator and configure.
7. RS-232C D-B 9: Pin 3 Output (TXD) and Pin 5 Signal Ground (GND)
8.
: Battery capacity
: Weight stable
0: Zero mode
UU: User weighing unit mode
4. Configuration
1. Correct connect load cell wireless weighing transmitter wireless weighing indicator
2. Configure as follow step
3. Press * to configure and next step
Step
1
Operation
Displaying
Press 0 000000
On
999999
Descriptions
In switch off states, press 0 key and ON to switch on
indicator. Segment checks, and displays [UE-22.0] to configure and
calibrate
Press *
Press *
Press
Select division
Press
Or 0
0.001-0.002-0.005-10-20-50-100-200-500-0.10-0.20-0.50-1-2
-5-0.1-0.2-0.5-0.01-0.02-0.05
Factory default d = 0.01
Press *
Press
Press
6000
000000
001000
015000
Press *
Press
Press
Or 0
FLt 1
Filter range: 0 ~ 2
0-fastest 2-slowest
Digit flashes
Factory default Filter = 2
Press *
Press
Press
Or 0
AUtP00
Press *
Press
Press
Or 0
Adr 00
Select address:
Continuous data output , Adr=00 or Adr=99
Communicate is by modbus between 01-95
Factory default Address = 00
Press *
Press
Or 0
b 2400
b 4800
Press *
Confirm configuration
and automatic
and automatic
and automatic
and automatic
and automatic
and automatic
5. Wireless Communicate
After above configuration, set the wireless communicate
Step
Operation
Displaying
Descriptions
Press
Press
Press
Press
Press
*
*
*
*
*
CAL SP
-SEt-
-A-d-
FACT
Con
Press
Con 78
Press *
Press *
ConSEA
Press
Con xx
Con-78
Press
2300
Press *
2300
2300
6. Calibrate
After above setting, calibrate indicator directly:
Step
Operation
Displaying
Descriptions
Press *
Press
CAL SP
CAL 00
Press *
------
3000
Set ZERO
After several seconds, indicator displays maximum weight
Display weight
Press
Press
Or 0
000000
Press *
------
2000
3000
002000
Operation
Displaying
Press *
CAL SP
Press *
-SEt-
Press *
-A -d-
Press
43125
Press *
Descriptions
Indicator in calibration mode
8. Factory Set
Step
Operation
Displaying
Press *
CAL SP
Press *
-SEt-
Press *
-A -d-
Press *
FACt
Press
Descriptions
Indicator in calibration mode
9. Weighing Unit
Step
Operation
Displaying
Press *
On
000000
999999
Press
2.0000
Select unit
Press
000000
Digit flash
Press
0
01.6535
Press *
HE
Descriptions
Press
HE
Digit flash
Press
0
HE
Change digit
Press *
d 0. 0.0
Press
0
d 0. 0
Change situation
10
Press *
10. Operation
1. ON/OFF Press ON switch on indicator; and press OFF to switch off indicator.
2. ZERO Press 0 for more than two seconds when Weight is 2F.S, weight is ZERO and
0 will be displayed
3.
TARE
a. Weight tare When T turns off and weight is 0 stable, press 0 to display Zero and
T turns on
b. Remove tare When T turns on, press 0 to clear tare and T turn off
c. Number tare Press to set tare. Press to enter tare (unit is kg), and press 0
to save tare and T turns on
d. Accumulation
In manual accumulation mode, weight is 20d stable, press to accumulate
weight and display accumulation times, e.g.: n 12
Note: one weighing result only can accumulate one time, next accumulation weight must after weight
20d.
4. High resolution In weighing mode, press to display the weight in X10 resolution and last
decimal point turns on. Press again to show regular weighing resolution.
Note: In lb and UU mode, indicator has no high resolution function.
5. Display accumulation (in weighing mode)
Step
Operation
Displaying
Descriptions
Press *
12
Press
23
Press
L506.5
Operation
Displaying
Press *
Press *
Aut 0
12
Descriptions
Display accumulation times
Select manual/automatically accumulation
Aut=0: regular weighing mode and manual accumulation
Aut=1: regular weighing modeautomatically accumulation after
stable, and -AUT- turns on
Aut=2: regular weighing modesave weight automatically after
stable, accumulate finial weight which is unload 20d, -AUT-
turns on
Aut=3: animal weighing mode, accumulate automatically finial
Press
Press
Or 0
Aut 0
Change mode
Press *
Press
Or 0
Press *
7. Clear accumulation
Press * to display accumulation data and press 0 to clear
accumulation data.
8. Enter number Press to move flashing digit, press to increase flashing digit and press
0 to decrease flashing digit.
9. Rechargeable internal battery Switch on indicator and display Pbt 85 means battery capacity is
85%
10. Remind charge battery
battery. When battery capacity is 10%, display flashes to remind user charge battery immediately.
11. Over-discharge protection
When battery capacity is 0%, indicator will switch off automatically to
protect battery.
12. Save power mode In switch off automatically mode, display to save power after three
minutes no operation.
13. Switch off automatically In switch off automatically mode, indicator will switch off after 30 minutes
no operation.
14. Full charge battery operation
Indicator can work 30 hours continually.
15. kglbUU
Press * more than 2 second to change weighing unit. The change order is
kglbUUkg.
16. When wireless weighing transmitter battery capacity is 10%, up digit displays b, e.g.: b 3.00
Operation
Displaying
Load samples
press
Cnt000
press
Cnt030
27
Descriptions
Display weighing of samples
press
or 0
4
press *
30
press
27
2. Operation put the weight on scale, number is weight when indicator displays
54, and number
is amount when indicator displays C 60. Press to change weight and amount displaying. After
the sample weight is stable, press to displays accumulate weight and amount.
3. Display and clear accumulated data
Step
Operation
Displaying
Descriptions
Press *
Press
Press *
Press
Press *
Press
Press
Press *
Press *
10
Press 0 C
C: 54pcs
Accumulation mode
NO: 0002
S: 5.82kg
Accumulation with counting mode:
NO: 0002
C: 108pcs
S: 5.82kg
16. Services
The Warranty time is in one year after sale date of non-human failure. Indicator is lifelong service.
(NOTE: Battery is not under warranty)
Meaning
OUEr
Weight > FS + 9d
OUEr