Sunteți pe pagina 1din 37

PrM Procedure- BSS

Document History
Document Author

S. Santhosh

GNSC Chennai VF

Santhosh.s@nsn.com

Document Contributor(s)
Document Approver

Siva M

FM- Manager- VF

siva.m@nsn.com

Document Release Authority

Sivasankara
Kumar

Customer Operation
Manager- VF

sivasankara.kumar@nsn.
com

Versions
Date

Name

20.08.2010

S.Santhosh

Version
Version 2.0

Nokia Siemens Networks

Contents of change
Updated Version

Page 1 , Total
39

PrM Procedure- BSS

1
1.1

BSS Health Check Report Work Instructions


Step 1: Enter the site

https://wahlogon.inside.nokiasiemensnetworks.com/Citrix/MetaFrame/auth/login.aspx

Nokia Siemens Networks

Page 2 , Total
39

PrM Procedure- BSS

1.2

Step 2: Login using your NSN-INTRA Login and Password

Nokia Siemens Networks

Page 3 , Total
39

PrM Procedure- BSS

1.3

Step 3: Choose the Citrix Icon for the respective Client

Nokia Siemens Networks

Page 4 , Total
39

PrM Procedure- BSS

1.4

Step 4: Choose the Circle for which you require the Data

Nokia Siemens Networks

Page 5 , Total
39

PrM Procedure- BSS

1.5

Step 5: Choose the Icon Administration

Nokia Siemens Networks

Page 6 , Total
39

PrM Procedure- BSS

1.6

16

Step 6: Choose the Icon SSH client

Nokia Siemens Networks

Page 10, Total 39

PrM Procedure- BSS

1.7

16

Step 7: Update Host and User Name to connect

Nokia Siemens Networks

Page 11, Total 39

PrM Procedure- BSS

1.8

16

Step 8: Enter your password for Authentication

Nokia Siemens Networks

Page 12, Total 39

PrM Procedure- BSS

1.9

16

Step 9: Run Health Check script using the command sh fm_health.sh

Nokia Siemens Networks

Page 13, Total 39

PrM Procedure- BSS

1.10 Step 10: The Raw files are stored in the Daily folder.

16

Nokia Siemens Networks

Page 14, Total 39

PrM Procedure- BSS

1.11 Step 11: Download the Raw files from SSH Client:

16

Nokia Siemens Networks

Page 15, Total 39

PrM Procedure- BSS

1.12 Step 12: Save the raw files in the local drive:

16

Nokia Siemens Networks

Page 16, Total 39

PrM Procedure- BSS

1.13 Step 13: Run the Health Check Macro in the mentioned path:

16

Nokia Siemens Networks

Page 17, Total 39

PrM Procedure- BSS

1.14 Step 14: After double clicking the Nokia_HC Macro


We will get the window as attached below. Here we have to choose the value of I based
upon the number of circles for which we are running the Macro. For the below one I am
running the Health check macro for UPW circle only. If we want Gujarat also, then the value of i
should be from 1 to 5.

16

Nokia Siemens Networks

Page 18, Total 39

PrM Procedure- BSS

1.15 S t e p 15: Click the Command Button1 to run the Macro:

16

Nokia Siemens Networks

Page 19, Total 39

PrM Procedure- BSS

1.16 Step 16: Once the macro was run,


The Health Check files are automatically stored in the Modified folder (Note the Path of
Folder):

1.17 Step 17: The face of the Health Check file is shown below.
Note the various files of Health Check Report and the status of the entire BSC:

2009-11-16

Nokia Siemens Networks

Page 20, Total 39

PrM Procedure- BSS

1.18 Step 18: The below mentioned window


Is the one we have finally, after finishing the HC report. Note the difference between this one and
the one which is above. If the problem is corrected then we have to replace the NOK with OK.
For example let us take the CGR problem in CNDBSC28. We gave reset to those circuits
and all the circuits are working now. Then we have to replace the NOK (see above fig) with
OK (below fig).

2009-11-16

Nokia Siemens Networks

Page 21, Total 39

PrM Procedure- BSS

1.19 Step 19: Please find the Action Taken sheet:

2009-11-16

Nokia Siemens Networks

Page 22, Total 39

PrM Procedure- BSS

1.20 Step 20: Check the Blocked Alarms list.


This is to verify whether there were any important alarms blocked in the Network.

2009-11-16

Nokia Siemens Networks

Page 23, Total 39

PrM Procedure- BSS

1.21 COMMAND s related to Health Check Report:

1.21.1

ZIFO:OMU:MEASUR;

To check the status of Measurement files:


If Files are not transferred then we have to inform to OSS. If needed, we have to co- ordinate
with the Field Engineers.

2009-11-16

Nokia Siemens Networks

Page 24, Total 39

PrM Procedure- BSS

1.21.2

ZNEL;
To check the status of Signalling Links:

2009-11-16

Nokia Siemens Networks

Page 25, Total 39

PrM Procedure- BSS

1.21.3

ZFXO:BCSU=0&&6:BTS;
To check the status of GPRS links:

1.21.4

ZCEL:CGR=1;
To check the status of CGR:

2009-11-16

Nokia Siemens Networks

Page 26, Total 39

PrM Procedure- BSS

1.21.5

ZCEL:CGR=1,FORM=EXT,ST=BL-SY;
To see the circuits which are in BL-SY state

1.21.6

ZCEC:
To give reset to the circuits:
ZCEC:ETPCM=512,CRCT=1-1&&-31:BL;
ZCEC:ETPCM=512,CRCT=1-1&&-31:NU;
ZCEC:ETPCM=512,CRCT=1-1&&-31:BL;
ZCEC:ETPCM=512,CRCT=1-1&&-31:WO;

2009-11-16

Nokia Siemens Networks

Page 27, Total 39

PrM Procedure- BSS

2009-11-16

Nokia Siemens Networks

Page 28, Total 39

PrM Procedure- BSS

1.21.7 ZICL;

To check the status of Command Calender:

2009-11-16

Nokia Siemens Networks

Page 29, Total 39

PrM Procedure- BSS

If there is no Command calendar, then the command to create it are:

ZIEE:WSB,:MMDIRE,:BACKUP,CMD,VB:; Y
ZWKS:MODE=DATA:;
/* CNTRL+C */
ZICI::BACKUP,:DATE=,TIME=23-30,PTYPE=DA,PNBR=1,NBR=255,:; ZICL;
ZAHO::NR=2518;
ZACA:2518;

1.21.8 ZDRI;
To check the Synchronization Inputs:

Nokia Siemens Networks

Page 30, Total 39

PrM Procedure- BSS

To disconnect and connect the syn input


ZDRD:2M1; ZDRC:2M1;

Nokia Siemens Networks

Page 31, Total 39

PrM Procedure- BSS

Nokia Siemens Networks

Page 32, Total 39

PrM Procedure- BSS

1.21.9

ZUSI:COMP;

To Check the status of Computer Units(BCSU, MCMU, OMU & EMB), clock units:

Nokia Siemens Networks

Page 33, Total 39

PrM Procedure- BSS

1.21.10

ZUSI:CLS,1;

Nokia Siemens Networks

Page 34, Total 39

PrM Procedure- BSS

To Diagnoise the Units: Make the unit to SPARE state and move it to TE-EX state, diagnose
the unit, see the current diagnose and History to find whether the unit is OK or NOT OK.
ZUSC:BCSU,0:TE;
ZUDU:BCSU,0;
ZUDQ;
ZUDH;

Nokia Siemens Networks

Page 35, Total 39

PrM Procedure- BSS

If unit is NOK OK then replace the Faulty Card and again diagnoise it and move it to the original
state.

Nokia Siemens Networks

Page 36, Total 39

PrM Procedure- BSS

1.21.11

ZISI::FDU;

To Check the status of I/O units(FDU & WDU):

1.21.12

ZISI::WDU;

To Diagnoise the Units: Make the Unit to TE-ID state, see the current diagnoise and
History to find whether the unit is OK or NOT OK.
ZISC::FDU,0:TE-ID;
ZUDD:OMU:FDU,0;
ZUDQ;
ZUDH;

Nokia Siemens Networks

Page 37, Total 39

PrM Procedure- BSS

Nokia Siemens Networks

Page 38, Total 39

PrM Procedure- BSS

If unit is NOT OK then replace the Faulty Unit and again diagnoise it and move it to the original
state.

Nokia Siemens Networks

Page 39, Total 39

PrM Procedure- BSS

1.22 More Commands Related to HealthCheck


No.
1

FORM DESCRIPTION

COMMANDS

All BSC units Working Status

ZUSI:ALL;

I/O Device Working Status

ZISI

Software Fall back in WDU & Safe copy


in MO/External drive

ZWKS, ZIPS, ZIBC

Consistency Check for SW Packages

ZWQB

Major & Critical Alarms to be verified

ZAHO,ZAHP,ZEOL
(7745)

3
4
5

6
7
8
9

All the SYNC inputs are connected and


clocks units ok
All BCF Synch settings / DAC values to
be checked
All computer / sig unit CPU utilization &
sigload observation

ZDRI
ZEOL (7601)

Should be in synch with the BSC

ZDOI & ZOLT

Signaling load should be within 200 milli Er &


CPU utilization should be optimum

10
11

Checking the status of all Gb links

ZUSI:TCSM,
ZDTF & ZCEL,
ZWGO
ZFXI, ZFWO

Checking the status of TRX'S AND TS'S

ZEEL:BL;

12

The LAPD of the BCCH TRX is 32 Kbps


if the LU or Paging is high for specific
BTS
MBCCH /MBCCB defined and optimum
SDCCHs are defined per sector
Optimize the time slots defined for
GPRS/EDGE on BTS
Proper distribution between AMR and
Non-AMR CGRs/ TCSMs

13
14
15
16
17

Vrification of all transcoders, circuits & its


LAPD

20
21

ZERO:BCF=BCF
ID;
ZEQO:BTS=x:GPR
S;
AS per MSC CGR
Report
ZNLI, ZNEL

X.25 state

ZQLI and ZQLP

BSC external alarm ok


19

ZDSB

SIGNALLING link STATE

18

BSC/Critical node redundant


power
supply availability
Equal Distribution of CCS7 and LAPD
signalling links
Active Alarm in BSC

Expected Results
All the Computer Units are in WO-EX or SPEX state
All the I/O interfaces, Both WDU, external
backup device(FDU,MO etc) are in working
condition
Recent Fall Back & its Backup of the same to
be available
Both BU & FB Package should pass the
consistency checks
All Major alarms currently active to be
cleared. Any major or critical alarm in history
needs to be analysed.
All BSC synch inputs should be connected
with no errors

ZWAT,ZAHO(4000
series
alarm)
ZAHO
in
case0020of BSC

All transcoders, LAPD & circuits should be in


working state
All Gb links should be in operational state
No Time Slots in BL-SYS, BL-TRX or BLRSL state
Decrease the paging
Optimum channel definition verified
Verify CDED, CDEF and CMAX Values
Proper distribution as per load verified
All link should be working and unique to be
distributed on ET/STMU cards
Need to check
X.25 state (redundancy
mode ) and its adjancency state
BSC equipped with
whenever requires

tested

ext

Redundant source requires

ZNEL
ZAHO

Nokia Siemens Networks

Act on the alarm based on severity

Page 40, Total 39

alarm