Sunteți pe pagina 1din 64

No

4
5

10

11

Ericsson
Parameter

Object

Nokia
Default

Unit

Utran Cell
accessClassNBarred
0 (=not barred)
Indicates whether access class N (N=0 to 15) is barred or not. 0=not barred, 1=barred

Object

WCEL
Define whether the cell is barred or not. UE will
even for emergency call purpose.

Utran Cell
cellReserved
NOT_RESERVED WCEL
Indicates if this cell shall be reserved for operator use. If it is reserved, there will be no service Indicates if this cell shall be reserved for operat
to the UEs.
service to the UEs.. When cell status is "not ba
the UEs assigned to Access Class 11 or 15 ma
PLMN. UEs assigned to Access Class in the ra
if cell status "barred" is indicated.

Utran Cell
treSelection
2 s
WCEL
Time-to-trigger for cell reselection in seconds. Value launched by System information (SIB3). The UE triggers the reselection of a new cell if
The UE reselects new cell if the cell reselection criteria are fulfilled during this time interval.
during the time interval Treselection.
UtranCell

qQualMin

-18

dB

Minimum required (acceptable) quality level in the cell (dB).


UtranCell

qRxLevMin

-115

WCEL

The minimum required quality level in the cell (


dBm

WCEL

Minimum required (acceptable) RX level in the cell.

The minimum required RX level in the cell.

ExternalUtranCell
qQualMin
100
dB
Minimum required (acceptable) quality level in neighbor cell (dB) for cell reselection to that
cell. If neighbor cell belong to same RNC, then the Object of parameter will be UtranCell.100 :
Indicates that the minimum quality level has not been specified by the operator. The
parameter is then not present in SIB11 for this neighbour. The UE will use the serving cell
value (UtranCell MO value) instead.

HOPI
Determines the minimum required CPICH Ec/N
measurement result of the inter-frequency neig
becomes possible.

ExternalUtranCell
qQualMin
100
dB
Minimum required (acceptable) quality level in neighbor cell (dB) for cell reselection to that
cell. If neighbor cell belong to same RNC, then the Object of parameter will be UtranCell.100 :
Indicates that the minimum quality level has not been specified by the operator. The
parameter is then not present in SIB11 for this neighbour. The UE will use the serving cell
value (UtranCell MO value) instead.

HOPS
Determines the minimum required CPICH Ec/N
measurement result of the neighbouring cell be
possible.

ExternalUtranCell
qRxLevMin
100
dBm
Minimum required (acceptable) RX level in neighbor cell (dBm). If neighbor cell belong to
same RNC, then object parameter will be UtranCell. 100 : Indicates that the minimum Rx level
has not been specified by the operator. The UE will use the serving cell value (UtranCell MO
value) instead.

HOPS
The parameter determines the minimum requir
measurement result of the neighbouring cell m
possible.

ExternalUtranCell
qRxLevMin
100
dBm
Minimum required (acceptable) RX level in neighbor cell (dBm). If neighbor cell belong to
same RNC, then object parameter will be UtranCell. 100 : Indicates that the minimum Rx level
has not been specified by the operator. The UE will use the serving cell value (UtranCell MO
value) instead.

HOPI
The parameter determines the minimum requir
measurement result of inter-frequency neighbo
selection is possible.

ExternalGsmCell
qRxLevMin
-105
Minimum required (acceptable) RX level in the cell. (dBm).

dBm

HOPG
Determines the minimum required RSSI level w
GSM neighbour cell must exceed before the ce

WCEL

Defines whether intra-frequency cell re-selectio


barred. When a cell's status is "barred", the UE
cell, except in some cases for an emergency ca

11

12

When the cell is barred, the UE must check be


period, whether the status of the barred cell ha

13

WCEL

UtranCell

qHyst1

dB

WCEL
Qhyst1 is used for TDD and GSM cells, and for
Hysterisis value that is read in the system information of serving cell, and used for cell ranking selection quality measure is set to CPICH RSC
and cell reselction process. It is used when qualMeasQuantity is set to CPICH RSCP
UtranCell

qHyst2

dB

14

WCEL
Qhyst2 is used for FDD cells when cell selectio
to CPICH Ec/No.

Hysterisis value that is read in the system information of serving cell, and used for cell ranking
and cell reselction process. It is used when qualMeasQuantity is set to CPICH Ec/No

15

16

17

18

19

20

UtranCell
maxTxPowerUl
24
dBm
The maximum UE transmission power on the RACH when accessing the system.Used in UE
functions for cell selection/reselection in idle mode and connected mode. Also used by
UTRAN to control the maximum TX power level an UE may use.If the current UE uplink
transmit power is above the indicated power value, the UE shall decrease the power to a level
below the power value.

WCEL
This parameter defines the maximum transmis
It is signaled to UE in the Maximum allowed UL
when a radio link is set up.

ExternalUtranCell
maxTxPowerUl
100
dBm
The maximum UE transmission power on the RACH when accessing the system.Used in UE
functions for cell selection/reselection in idle mode and connected mode. Also used by
UTRAN to control the maximum TX power level an UE may use.If the current UE uplink
transmit power is above the indicated power value, the UE shall decrease the power to a level
below the power value.Special values:100: Indicates that the maximum UL transmission power
has not been specified by the operator. The parameter is then not present in SIB11 for this
neighbour. The UE will use the serving cell value (UtranCell MO value) instead.

ADJI
This parameter indicates the maximum transm
when accessing inter-frequency neighbouring c
parameter in the cell re-selection procedure. If
lower than the value of the parameter, the UE a
the minimum required CPICH Ec/No level, whic
neighbouring cell must exceed before the cell r

ExternalUtranCell
maxTxPowerUl
100
dBm
The maximum UE transmission power on the RACH when accessing the system.Used in UE
functions for cell selection/reselection in idle mode and connected mode. Also used by
UTRAN to control the maximum TX power level an UE may use.If the current UE uplink
transmit power is above the indicated power value, the UE shall decrease the power to a level
below the power value.Special values:100: Indicates that the maximum UL transmission power
has not been specified by the operator. The parameter is then not present in SIB11 for this
neighbour. The UE will use the serving cell value (UtranCell MO value) instead.

ADJS

ExternalGsmCell
maxTxPowerUl
100
dBm
The maximum UE transmission power on the RACH when accessing the system.Used in UE
functions for cell selection/reselection in idle mode and connected mode. Also used by
UTRAN to control the maximum TX power level an UE may use.If the current UE uplink
transmit power is above the indicated power value, the UE shall decrease the power to a level
below the power value.Special values:100: Indicates that the maximum UL transmission power
has not been specified by the operator. The parameter is then not present in SIB11 for this
neighbour. The UE will use the serving cell value (UtranCell MO value) instead.

ADJG
This parameter indicates the maximum transm
when accessing the GSM neighbouring cell on
in the cell re-selection procedure. If the maximu
the value of the parameter, the UE adds the po
minimum required CPICH Ec/No level, which th
neighbouring cell must exceed before the cell r

UtranCell
sIntraSearch
0
dB
The decision on when measurements on intra frequencies shall be performed. If Squal <=
sIntraSearch, UE performs intra-frequency measurements.

WCEL

UtranCell

WCEL

sInterSearch

dB

This parameter indicates the maximum transm


when accessing the neighbouring cell on the R
cell re-selection procedure. If the maximum out
value of the parameter, the UE adds the power
required CPICH Ec/No level, which the measur
must exceed before the cell re-selection is pos

The threshold for intra-frequency measuremen


Note: If no threshold is given, MS performs me

20

The decision on when measurements on inter frequencies shall be performed. If Squal <=
sInterSearch, the UE performs inter frequency measurements.

The threshold for inter-frequency measuremen


Note: If no threshold is given, MS performs me

21

UtranCell
sRatSearch
2
dB
The decision on when measurements on GSM frequencies shall be performed is made using
this parameter in relation with Squal. If S_qual > this parameter, no need for UE to perform
measurements on GSM cells.
If S_qual <= this paramter, UE shall perform measurment on GSM cells.

WCEL
The RAT-specific threshold for inter-RAT meas
given, MS performs measurements.

WCEL

Threshold for skipping inter-RAT measurement


threshold in the serving UTRA cell, the UE doe
measurements. Needed only if HCS is used.

22

23

UtranRelation
qOffset1sn
0
dB
HOPI
Signal strength offset between souce and target cells. used when the IE
This parameter is used in the cell re-selection a
"cell_selection_and_reselection_quality_measure" in SIB 11/22 is set to "CPICH RSCP". This value of this parameter is subtracted from the m
is configured through UtranCell::qualMeasQuantity.
frequency neighbour cell before the UE compa
selection/ranking criteria.

24

UtranRelation
qOffset1sn
0
dB
HOPS
Signal strength offset between souce and target cells. used when the IE
This parameter is used in the cell re-selection a
"cell_selection_and_reselection_quality_measure" in SIB 11/22 is set to "CPICH RSCP". This value of this parameter is subtracted from the m
is configured through UtranCell::qualMeasQuantity.
cell before the UE compares the quality measu
criteria.
GsmRelation

25

qOffset1sn

dB

HOPG

Signal strength offset between source and target cells. Dependencies:Used when the IE
This parameter is used in the cell re-selection a
"cell_selection_and_reselection_quality_measure" in SIB 11/12 is set to "CPICH RSCP". This cells. The value of this parameter is subtracted
is configured through UtranCell::qualMeasQuantity.
neighbour cell before the UE compares the qua
selection/ranking criteria.
HOPI

26

UtranRelation
qOffset2sn
0
dB
Signal strength offset between souce and target cells. used when the IE
"cell_selection_and_reselection_quality_measure" in SIB 11/22 is set to "CPICH Ec/No".

27

UtranRelation
qOffset2sn
0
dB
Signal strength offset between souce and target cells. used when the IE
"cell_selection_and_reselection_quality_measure" in SIB 11/22 is set to "CPICH Ec/No".

HOPS
This parameter is used in the cell re-selection a
value of this parameter is subtracted from the m
cell before the UE compares the quality measu
criteria.

This parameter is used in the cell re-selection a


value of this parameter is subtracted from the m
frequency neighbour cell before the UE compa
selection/ranking criteria.

ADJG
The parameter indicates whether the GSM neig
Information Block 11&12&18 for the cell selecti
GSM neighbour cell is included in the system in
parameter is "yes". The parameter AdjgSIB doe
CELL_DCH state of connected mode. That is,
for the inter-system handover regardless of the

ADJI

28

29

This parameter indicates whether the inter-freq


System Information Block 11&12&18 for the ce
procedures. The inter-frequency neighbour cell
when the value of the parameter is "yes". Note:
interfrequency measurements in CELL_DCH st
frequency neighbour cells are monitored for the
the value of the parameter AdjiSIB
ADJS

30

The parameter indicates whether the intra-frequ


System Information Block 11&12&18 for the ce
procedures. The intra-frequency neighbour cell
when the value of the parameter is "yes".The p
intrafrequency measurements in CELL_DCH st
frequency neighbour cells are monitored for the
value of the parameter AdjsSIB.

30

PlmnIdentityGroup
31

PlmnIdentityGroup
32

34

35

1 -

WCELL
Unique country identification. MCC consist 3 di
the PLMN uniquely (globally).

plmn.mnc

1 -

WCELL
Unique network identification within country. MN
together with MCC identifies the PLMN uniquel

The MNC part of a PLMN identity used in the radio network. Range: 0-999
UtranCell

33

plmn.mcc

The MCC part of a PLMN identity used in the radio network. Range: 0-999

primaryScramblingCode

The primary downlink scrambling code to be used in the cell.Disturbances:Changing this


attribute may affect ongoing traffic.Range:0-511
UtranCell
sHcsRat
-105
dB
RAT specific threshold in the serving cell used in the inter-RAT measurement rules.This
parameter is used by the UE to decide when to start GSM measurements for cell reselection,
if the serving cell is indicated to belong to a Hiearachical Cell Structure (HCS).GSM
measurements in idle mode and state CELL_FACH are started by the UE when RSCP <=
qRxLevMin + sHscRat.

WCEL
The RAT specific threshold for inter-RAT meas
used.

t3212
UtranCell
Periodic update timer for LA update.

RNC
The timeout value, in decihours (6 min), for per
CS domain. (Part of CS domain specific NAS S
location update shall not be used.

10

decihour(6min)

Paging
36

cnDrxCycleLengthCs
6 10(2^k)ms
Core Network DRX cycle length coefficient (k) for UEs in idle mode, circuit switched. The cycle
length is calculated as the k'th potential of 2, where k = 6..9. For example, 6 corresponds to
cycle length 640 ms, 7 corresponds to cycle length 1280 ms, etc.
Paging

37

cnDrxCycleLengthPs
7 10(2^k)ms
Core Network DRX cycle length coefficient (k) for UEs in idle mode, packet switched. The
cycle length is calculated as the k'th potential of 2, where k = 6..9. For example, 6
corresponds to cycle length 640 ms, 7 corresponds to cycle length 1280 ms, etc.

Paging
38

WCEL
Identifies the downlink scrambling code of the P
CPICH (Common Pilot Channel) of the Cell.

utranDrxCycleLength
5
10(2^k)ms
The DRX cycle length coefficient (k) for UEs in URA_PCH. The DRX cycle length is the
frequency with which the Ue listens on the paging channel. The parameter is applicable for
both UTRAN and CN initiated paging in URA_PCH. Value mapping:
The cycle length is calculated as the k'th power of 2, where k = 3..9. For example, 6
corresponds to cycle length 640 ms, 7 corresponds to cycle length 1280 ms, etc.

RNC
The DRX cycle length used for CN domain to c
reception. This parameter is given for CS doma
duration of the DRX cycle is 2 <power> k frame
length coefficient for CN.)
RNC
The DRX cycle length used for CN domain to c
reception. This parameter is given for CS doma
duration of the DRX cycle is 2 <power> k frame
length coefficient for CN.)

WCEL
The DRX cycle length used by UTRAN to coun
reception.(The duration of the DRX cycle is 2 <
where 'k' is the used DRX cycle length coefficie

Sid
39

noOfMaxDrxCycles
1
Paging notification duration. To notify UEs in IDLE mode about a system information update,
the RNC sends a paging message on the PCH at every page occasion of a number of
maximum DRX cycles.
Sid

40

41

sib7ExpirationTimeFactor

WCEL

SIB7 use expiration time as re-read mechanism. The expiration time is sib7RepPeriod times
sib7ExpirationTimeFactor. Note that the following mapping applies between the configured
value and the value sent in the RRC message System Information Block Type 7: Configured
value <=> IE value sent in SIB7. 1 <=> IE not sent , 2 <=> 1, 4 <=> 2, 8 <=> 3, 16 <=>
4, 32 <=> 5, 64 <=> 6, 128 <=> 7, 256 <=> 8

This parameter sets the SIB7 expiration timer f


formula: MAX([320ms], SIB_REP x value of 'SI

UtranCell

fachMeasOccaCycLenCoeff

41

Fach Measurement Occasion Cycle Length coefficient.A factor used when the UE performs
inter-frequency and inter-system measurements. The UE uses this parameter to calculate the
interval length in order to determine the repeating cycle of the measurement. Value mapping:
0 : not broadcasted in SIB 11, 1 : not used, 2 : not used, 3 : used when inter frequency and
GSM neighbours,4 : used when inter freqency or GSM neighbours,5 - 12 not used.
UtranCell

42

43

interFreqFddMeasIndicator
FALSE
Inter-frequency FDD measurement indicator. Value mapping: FALSE = No, TRUE = Yes

44

HOPI
This parameter is used in the cell ranking betw
inter-frequency neighbour cell has the same HC
neighbour cell has a different HCS priority leve
cell re-selection between GSM and WCDMA ce
Penalty Time) from the measured CPICH RSC
The alternative values are the following: 3 dB, 6
and 'Infinity'.

HOPS
This parameter is used in the cell ranking betw
neighbour cell has the same HCS priority level
has a different HCS priority level, the offset valu
selection between GSM and WCDMA cells. Th
Time) from the measured CPICH RSCP of the
are the following: 3 dB, 6 dB, 9 dB, 12 dB, 15 d

HOPG
This parameter is used in the cell ranking betw
GSM neighbour cell has the same HCS priority
neighbour cell has a different HCS priority leve
cell re-selection between GSM and WCDMA ce
Penalty Time) from the measured RSSI level o
values are the following: 3 dB, 6 dB, 9 dB, 12 d

HOPI
This parameter is used in the cell ranking betw
frequency neighbour cell has the same HCS pr
neighbour cell has a different HCS priority leve
cell re-selection between WCDMA cells. The o
from the measured CPICH Ec/No of the inter-fr
values are the following: 2 dB, 3 dB, 4 dB, 6 dB

HOPS
This parameter is used in the cell ranking betw
cell has the same HCS priority level as the serv
different HCS priority level, the offset value is a
between WCDMA cells. The offset is subtracte
measured CPICH Ec/No of the neighbour cell.
2 dB, 3 dB, 4 dB, 6 dB, 8 dB, 10 dB, 12 dB and

47

46

45

48
-

49

WCEL
This parameter defines the HCS priority level fo
HCS priority and value 7 indicates the highest H
needed if HCS is not used.

WCEL

49

This parameter indicates whether the serving c


Structure (HCS), or not.

50

WCEL
Quality threshold level (CPICH Ec/No) for apply
selection for a cell. Needed only if HCS is used

HOPI
Defines the threshold level which must be exce
frequency neighbour cell before the hierarchica

HOPS
Defines the threshold level which must be exce
neighbouring cell before the hierarchical cell re

HOPG
Defines the threshold which must be exceeded
GSM neighbour cell before the hierarchical cell

HOPI
Defines the time period during which the Temp
selection procedure for the inter-frequency neig

HOPS
Defines the time period during which the Temp
selection procedure for the neighbour cell in qu

HOPG
Determines the time period during which the Te
selection procedure for the GSM neighbour cel

WCEL
The duration for evaluating the allowed amount
reselections during the time period defined by T
been detected. Needed only if HCS is used.

WCEL
Cell reselection hysteresis for reverting from UE
additional time period before UE reverts to lownumber of cell reselections during the time peri
exceeds NCr, UE continues measurements dur
TCrmaxHyst. Needed only if HCS is used.

WCEL
This parameter defines the maximum number o
reselections during the TCrmax time period exc
been detected. Needed only if HCS is used. No

62

HOPG
Defines the priority level of GSM neighbour cel
procedure. 0 indicates the lowest HCS priority a
Lower HCS priority values are meant for larger
values are meant for smaller pico/micro cells.

61

60

59

58

HOPS
Defines the priority level of neighbouring cell in
procedure. 0 indicates the lowest HCS priority a
Lower HCS priority values are meant for larger
values are meant for smaller pico/micro cells.

57

56

55

54

HOPI
Defines the priority level of the inter-frequency
selection procedure. 0 indicates the lowest HCS
HCS priority. Lower HCS priority values are me
HCS priority values are meant for smaller pico/

53

52

51

63

WCEL
Threshold for intra and interfrequency measure
the serving cell, the UE initiates measurements
neighbouring cells of the serving cell

Nokia
Parameter

Default

Unit

CellBarred
1 (=not barred)
Define whether the cell is barred or not. UE will not allowed to camp on barred cell,
even for emergency call purpose.
Cell_Reserved
1 (=not reserved)
Indicates if this cell shall be reserved for operator use. If it is reserved, there will be no
service to the UEs.. When cell status is "not barred" and "reserved" for operator use,
the UEs assigned to Access Class 11 or 15 may select/re-select this cell if in the home
PLMN. UEs assigned to Access Class in the range 0 to 9 and 12 to 14 shall behave as
if cell status "barred" is indicated.

Treselection
1 s
The UE triggers the reselection of a new cell if the cell reselection criteria are fulfilled
during the time interval Treselection.
QqualMin

-18

dB

The minimum required quality level in the cell (Ec/No).


QrxlevMin

-115

dBm

The minimum required RX level in the cell.


AdjiQqualMin
-18
dB
Determines the minimum required CPICH Ec/No level which must be exceeded by the
measurement result of the inter-frequency neighbour cell before the cell re-selection
becomes possible.

AdjjsQqualMin
-18
dB
Determines the minimum required CPICH Ec/No level which must be exceeded by the
measurement result of the neighbouring cell before the cell re-selection becomes
possible.

AdjsQrxlevMin
-115
dBm
The parameter determines the minimum required CPICH RSCP level which the
measurement result of the neighbouring cell must exceed before the cell re-selection is
possible.

AdjiQrxlevMin
-115
dBm
The parameter determines the minimum required CPICH RSCP level which the
measurement result of inter-frequency neighbouring cell must exceed before the cell reselection is possible.

AdjgQrxlevMin
-101
dBm
Determines the minimum required RSSI level which the measurement result of the
GSM neighbour cell must exceed before the cell re-selection becomes possible.
IntraFreq_Cell_Reselect_Ind

0 (=allowed)

Defines whether intra-frequency cell re-selection is allowed or not when the cell is
barred. When a cell's status is "barred", the UE is not permitted to select/re-select this
cell, except in some cases for an emergency call.
Tbarred

20

When the cell is barred, the UE must check between the time interval Cell barred
period, whether the status of the barred cell has changed.
Qhyst1
0
dB
Qhyst1 is used for TDD and GSM cells, and for FDD cells when cell selection and reselection quality measure is set to CPICH RSCP.
Qhyst2
2
dB
Qhyst2 is used for FDD cells when cell selection and re-selection quality measure is set
to CPICH Ec/No.

UEtxPowerMaxDPCH
24
dBm
This parameter defines the maximum transmission power level a UE can use on DPCH.
It is signaled to UE in the Maximum allowed UL TX power IE of a proper RRC message,
when a radio link is set up.

AdjiTxPwrRACH
24
dBm
This parameter indicates the maximum transmission power level that a UE can use
when accessing inter-frequency neighbouring cell on the RACH. The UE uses the
parameter in the cell re-selection procedure. If the maximum output power of the UE is
lower than the value of the parameter, the UE adds the power difference (dB value) to
the minimum required CPICH Ec/No level, which the measurement result of the
neighbouring cell must exceed before the cell re-selection is possible.

AdjsTxPwrRACH

24

dBm

This parameter indicates the maximum transmission power level that a UE can use
when accessing the neighbouring cell on the RACH. The UE uses the parameter in the
cell re-selection procedure. If the maximum output power of the UE is lower than the
value of the parameter, the UE adds the power difference (dB value) to the minimum
required CPICH Ec/No level, which the measurement result of the neighbouring cell
must exceed before the cell re-selection is possible.
AdjgTxPwrRACH
24
dBm
This parameter indicates the maximum transmission power level that a UE can use
when accessing the GSM neighbouring cell on the RACH. The UE uses the parameter
in the cell re-selection procedure. If the maximum output power of the UE is lower than
the value of the parameter, the UE adds the power difference (dB value) to the
minimum required CPICH Ec/No level, which the measurement result of the
neighbouring cell must exceed before the cell re-selection is possible.

Sintrasearch

14

dB

The threshold for intra-frequency measurements, and for the HCS measurement rules.
Note: If no threshold is given, MS performs measurements.
Sintersearch

dB

The threshold for inter-frequency measurements, and for the HCS measurement rules.
Note: If no threshold is given, MS performs measurements.
Ssearch_RAT
2
dB
The RAT-specific threshold for inter-RAT measurement rules. Note: If no threshold is
given, MS performs measurements.

Slimit_SearchRAT

dB

Threshold for skipping inter-RAT measurement rules in HCS. Above this RAT specific
threshold in the serving UTRA cell, the UE does not need to perform any inter-RATm
measurements. Needed only if HCS is used.
AdjiQoffset1
0
dB
This parameter is used in the cell re-selection and ranking between WCDMA cells. The
value of this parameter is subtracted from the measured CPICH RSCP of the interfrequency neighbour cell before the UE compares the quality measure with the cell reselection/ranking criteria.
AdjsQoffset1
0
dB
This parameter is used in the cell re-selection and ranking between WCDMA cells. The
value of this parameter is subtracted from the measured CPICH RSCP of the neighbour
cell before the UE compares the quality measure with the cell re-selection/ranking
criteria.
AdjgQoffset1

dB

This parameter is used in the cell re-selection and ranking between WCDMA and GSM
cells. The value of this parameter is subtracted from the measured RSSI of the GSM
neighbour cell before the UE compares the quality measure with the cell reselection/ranking criteria.
AdjiQoffset2

0.4

dB

This parameter is used in the cell re-selection and ranking between WCDMA cells. The
value of this parameter is subtracted from the measured CPICH Ec/No of the interfrequency neighbour cell before the UE compares the quality measure with the cell reselection/ranking criteria.
AdjsQoffset2
0.4
dB
This parameter is used in the cell re-selection and ranking between WCDMA cells. The
value of this parameter is subtracted from the measured CPICH Ec/No of the neighbour
cell before the UE compares the quality measure with the cell re-selection/ranking
criteria.
AdjgSIB
1 (=YES)
The parameter indicates whether the GSM neighbour cell is included in the System
Information Block 11&12&18 for the cell selection and re-selection procedures. The
GSM neighbour cell is included in the system information when the value of the
parameter is "yes". The parameter AdjgSIB does not affect GSM measurements in
CELL_DCH state of connected mode. That is, all GSM neighbour cells are monitored
for the inter-system handover regardless of the value of the parameter AdjgSIB.
AdjiSIB

Yes (1)

This parameter indicates whether the inter-frequency neighbour cell is included in the
System Information Block 11&12&18 for the cell selection and re-selection
procedures. The inter-frequency neighbour cell is included in the system information
when the value of the parameter is "yes". Note: The parameter AdjiSIB does not affect
interfrequency measurements in CELL_DCH state of connected mode. That is, all interfrequency neighbour cells are monitored for the inter-frequency handover regardless of
the value of the parameter AdjiSIB
AdjsSIB

Yes (1)

The parameter indicates whether the intra-frequency neighbour cell is included in the
System Information Block 11&12&18 for the cell selection and re-selection
procedures. The intra-frequency neighbour cell is included in the system information
when the value of the parameter is "yes".The parameter AdjsSIB does not affect
intrafrequency measurements in CELL_DCH state of connected mode. That is, all intrafrequency neighbour cells are monitored for the soft(er) handover regardless of the
value of the parameter AdjsSIB.
MCC
1 0-999
Unique country identification. MCC consist 3 digits. MCC together with MNC identifies
the PLMN uniquely (globally).
MNC
1 0-999
Unique network identification within country. MNC consists of two or three digits. MNC
together with MCC identifies the PLMN uniquely (globally).
PriScrCode
Identifies the downlink scrambling code of the Primary
CPICH (Common Pilot Channel) of the Cell.
SHCS_RAT
1
dB
The RAT specific threshold for inter-RAT measurement rules. Needed only if HCS is
used.

CS_T3212
0
decihour(6min)
The timeout value, in decihours (6 min), for periodic location updating. Given only for
CS domain. (Part of CS domain specific NAS System information in SIB1). 0=periodic
location update shall not be used.
CNDRXLength
640ms (=6)
The DRX cycle length used for CN domain to count paging occasions for discontinuous
reception. This parameter is given for CS domain and PS domain separately. (The
duration of the DRX cycle is 2 <power> k frames, where 'k' is the used DRX cycle
length coefficient for CN.)
CNDRXLength
640ms (=6)
The DRX cycle length used for CN domain to count paging occasions for discontinuous
reception. This parameter is given for CS domain and PS domain separately. (The
duration of the DRX cycle is 2 <power> k frames, where 'k' is the used DRX cycle
length coefficient for CN.)
UTRAN_DRX_length
320 ms (5)
The DRX cycle length used by UTRAN to count paging occasions for discontinuous
reception.(The duration of the DRX cycle is 2 <power> k frames,
where 'k' is the used DRX cycle length coefficient for UTRAN.)

SIB7factor

This parameter sets the SIB7 expiration timer for the UE according to the following
formula: MAX([320ms], SIB_REP x value of 'SIB7 expiration time factor').

AdjiTempOffset1
6
dB
This parameter is used in the cell ranking between GSM and WCDMA cells when the
inter-frequency neighbour cell has the same HCS priority level as the serving cell. If the
neighbour cell has a different HCS priority level, the offset value is applied for the HCS
cell re-selection between GSM and WCDMA cells. The offset is subtracted (during
Penalty Time) from the measured CPICH RSCP of the inter-frequency neighbour cell.
The alternative values are the following: 3 dB, 6 dB, 9 dB, 12 dB, 15 dB, 18 dB, 21 dB
and 'Infinity'.
AdjsTempOffset1
10
dB
This parameter is used in the cell ranking between GSM and WCDMA cells when the
neighbour cell has the same HCS priority level as the serving cell. If the neighbour cell
has a different HCS priority level, the offset value is applied for the HCS cell reselection between GSM and WCDMA cells. The offset is subtracted (during Penalty
Time) from the measured CPICH RSCP of the neighbour cell. The alternative values
are the following: 3 dB, 6 dB, 9 dB, 12 dB, 15 dB, 18 dB, 21 dB and 'Infinity'
AdjgTempOffset1
6
dB
This parameter is used in the cell ranking between GSM and WCDMA cells when the
GSM neighbour cell has the same HCS priority level as the serving cell. If the GSM
neighbour cell has a different HCS priority level, the offset value is applied for the HCS
cell re-selection between GSM and WCDMA cells. The offset is subtracted (during
Penalty Time) from the measured RSSI level of the GSM neighbour cell. The alternative
values are the following: 3 dB, 6 dB, 9 dB, 12 dB, 15 dB, 18 dB, 21 dB and 'Infinity'.

AdjiTempOffset2
10
dB
This parameter is used in the cell ranking between WCDMA cells when the interfrequency neighbour cell has the same HCS priority level as the serving cell. If the
neighbour cell has a different HCS priority level, the offset value is applied for the HCS
cell re-selection between WCDMA cells. The offset is subtracted (during Penalty Time)
from the measured CPICH Ec/No of the inter-frequency neighbour cell. The alternative
values are the following: 2 dB, 3 dB, 4 dB, 6 dB, 8 dB, 10 dB, 12 dB and 'Infinity'

AdjsTempOffset2
3
dB
This parameter is used in the cell ranking between WCDMA cells when the neighbour
cell has the same HCS priority level as the serving cell. If the neighbour cell has a
different HCS priority level, the offset value is applied for the HCS cell re-selection
between WCDMA cells. The offset is subtracted (during Penalty Time) from the
measured CPICH Ec/No of the neighbour cell. The alternative values are the following:
2 dB, 3 dB, 4 dB, 6 dB, 8 dB, 10 dB, 12 dB and 'Infinity'
1(R99)
0(HSDPA)
HCS_PRIO
This parameter defines the HCS priority level for a cell. Value 0 indicates the lowest
HCS priority and value 7 indicates the highest HCS priority. This parameter is not
needed if HCS is not used.

UseOfHCS

0 (=not used)
1 (=used)

This parameter indicates whether the serving cell belongs to a Hierarchical Cell
Structure (HCS), or not.
AdjiHCSpriority
Defines the priority level of the inter-frequency neighbour cell in the hierarchical cell reselection procedure. 0 indicates the lowest HCS priority and 7 indicates the highest
HCS priority. Lower HCS priority values are meant for larger macro cells and higher
HCS priority values are meant for smaller pico/micro cells.
AdjsHCSpriority
Defines the priority level of neighbouring cell in the hierarchical cell re-selection
procedure. 0 indicates the lowest HCS priority and 7 indicates the highest HCS priority.
Lower HCS priority values are meant for larger macro cells and higher HCS priority
values are meant for smaller pico/micro cells.
AdjgHCSpriority
Defines the priority level of GSM neighbour cell in the hierarchical cell re-selection
procedure. 0 indicates the lowest HCS priority and 7 indicates the highest HCS priority.
Lower HCS priority values are meant for larger macro cells and higher HCS priority
values are meant for smaller pico/micro cells.
-24
QHCS
dB
Quality threshold level (CPICH Ec/No) for applying prioritised hierarchical cell reselection for a cell. Needed only if HCS is used.
AdjiHCSthreshold
Defines the threshold level which must be exceeded by the CPICH Ec/No of the interfrequency neighbour cell before the hierarchical cell re-selection becomes possible
AdjsHCSthreshold
Defines the threshold level which must be exceeded by the CPICH Ec/No of the
neighbouring cell before the hierarchical cell re-selection becomes possible
AdjgHCSthreshold
Defines the threshold which must be exceeded by the RSSI measurement result of the
GSM neighbour cell before the hierarchical cell re-selection becomes possible
AdjiPenaltyTime
0
s
Defines the time period during which the Temporary Offset 1/2 is applied in the cell reselection procedure for the inter-frequency neighbour cell.
AdjsPenaltyTime
0
s
Defines the time period during which the Temporary Offset 1/2 is applied in the cell reselection procedure for the neighbour cell in question.
AdjgPenaltyTime
0
s
Determines the time period during which the Temporary Offset 1 is applied in the cell reselection procedure for the GSM neighbour cell in question.
TCrmax
0
s
The duration for evaluating the allowed amount of cell reselections. If the number of cell
reselections during the time period defined by TCrmax exceeds Ncr, high mobility has
been detected. Needed only if HCS is used.
TCrmaxHyst
0
s
Cell reselection hysteresis for reverting from UE high-mobility measurements. The
additional time period before UE reverts to low-mobility measurements. When the
number of cell reselections during the time period defined by TCrmax no longer
exceeds NCr, UE continues measurements during the time period defined by
TCrmaxHyst. Needed only if HCS is used.
NCr
8
This parameter defines the maximum number of cell reselections. If the number of cell
reselections during the TCrmax time period exceeds the value of NCr, high mobility has
been detected. Needed only if HCS is used. Not used if TCrmax equals 'not used'

SsearchHCS
11
dB
Threshold for intra and interfrequency measurement rules in HCS. Below this limit in
the serving cell, the UE initiates measurements of all intra and inter-frequency
neighbouring cells of the serving cell

No

Object

Ericsson
Parameter

Default

Unit

Nokia
Parameter

Object

Rrc
1

t305
3 RNC
T305
The maximum time between adjacent Cell Updates (UE in CELL_FACH The periodic cell update/URA update timer (MS timer).
state) or URA Update (UE in URA_PCH state). Infinity means no
update.
UtranCell
rlFailureT
Guard period before sending RL Failure.
rlFailureT > (nInSyncInd * 10 ms)

10 s

RNC
T_RLFailure
If L1 timer T_RLFAILURE expires, a radio link is moved to the Out-of
state. The Radio Link Failure procedure is triggered after a period of t
after T_RLFAILURE has elapsed with a persisting out-of-sync indicat

UtranCell
nOutSyncInd
10
Number of frames to be considered for out-of-sync detection.

RNC
NOutSynchInd
The T_RLFAILURE timer is started after a number of consecutive Ou
indications equal to the value of N_OUTSYNC_IND are received.

UtranCell
nInSyncInd
3
Number of frames to be considered for in-sync detection.
(nInSyncInd * 10 ms) < rlFailureT

RNC
NInSynchInd
This parameter defines the number of successive in-sync indications
which the BTS triggers the Synchronisation indication procedure. A ra
is moved to the In-sync state after a number of consecutive In-sync
indications equal to the value of N_INSYNC_IND.

Rcs

5min

SecurityHandling
6

ciphering

Indicates whether ciphering is used or not.The value of this attribute


should reflect the configuration of the connected SGSN node.Value
mapping:0=off, 1=on
UeRcTrCh

cchWaitCuT

Waiting timer for cell update.

blerQualityTargetDl

BLER Quality Target DL.This attribute is valid only if CRC is used. MOM
value = 10 Log10(transport channel highest quality (BLER)).Value
mapping:-63: 0.0000005 = 0.00005 %...,-60: 0.000001 = 0.0001 %,...,25: 0.003 = 0.3 %,...,-20: 0.01 = 1 %,...,0: 1 = 100 %

RncFunction

emergencyCallRedirec OFF
t

RNC
EmergencyCallRedirect
This parameter enables/disables the redirect feature for emergency c
GSM on connection creation. When this parameter is enabled, all em
calls are directed to the GSM network.
10

10

RNC
CellDCHtestTmr
The timer CellDCHtestTmr defines the maximum time an inactive MS
allowed to remain in the CELL_DCH state. In the expiry of the timer, t
is switched to the CELL_FACH state if the parameter ToCellFACHinT
equal to 'Yes' and the procedures in the CELL_FACH state continue
normal. If ToCellFACHinTest is equal to 'No', an Iu release procedure
initiated and the MS is switched to the idle mode.

ChannelSwitching inactivityTimer
30
s
RNC
InactivityTimerDownlinkDCH
Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on downlink DCH before release proc
Default values: 8 kbps: 5 s 16 kbps: 5 s 32 kbps: 5 s 64 kbps: 3 s 128
s 256 kbps: 2 s 320 kbps: 2 s 384 kbps: 2 s
ChannelSwitching

11

WCEL
DLreferenceTargetBLER
The parameter defines the downlink target BLER for the reference se
the downlink power allocation.Reference service is used in the determ
of themaximum downlink code channel transmission power.Value of t
parameter is the log10 of the BLER value.

ChannelSwitching downswitchTimer
DownswitchTimer from DCH to FACH/RACH

inactivityTimer

30

RNC

InactivityTimerDownlinkDCH128

11

12

13

14

15

16

17

18

19

Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on downlink DCH before release proc
Timer is defined separately for each bit rate. Parameter value 255 (in
means that NRT DCH inactivity supervision is not used.

ChannelSwitching inactivityTimer
30
s
RNC
InactivityTimerDownlinkDCH16
Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on downlink DCH before release proc
Timer is defined separately for each bit rate. Parameter value 255 (in
means that NRT DCH inactivity supervision is not used.

ChannelSwitching inactivityTimer
30
s
RNC
InactivityTimerDownlinkDCH256
Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on downlink DCH before release proc
Timer is defined separately for each bit rate. Parameter value 255 (in
means that NRT DCH inactivity supervision is not used.

ChannelSwitching inactivityTimer
30
s
RNC
InactivityTimerDownlinkDCH32
Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on downlink DCH before release proc
Timer is defined separately for each bit rate. Parameter value 255 (in
means that NRT DCH inactivity supervision is not used.

ChannelSwitching inactivityTimer
30
s
RNC
InactivityTimerDownlinkDCH320
Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on downlink DCH before release proc
Timer is defined separately for each bit rate. Parameter value 255 (in
means that NRT DCH inactivity supervision is not used.

ChannelSwitching inactivityTimer
30
s
RNC
InactivityTimerDownlinkDCH384
Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on downlink DCH before release proc
Timer is defined separately for each bit rate. Parameter value 255 (in
means that NRT DCH inactivity supervision is not used.

ChannelSwitching inactivityTimer
30
s
RNC
InactivityTimerDownlinkDCH64
Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on downlink DCH before release proc
Timer is defined separately for each bit rate. Parameter value 255 (in
means that NRT DCH inactivity supervision is not used.

ChannelSwitching inactivityTimer
30
s
RNC
InactivityTimerDownlinkDCH8
Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on downlink DCH before release proc
Timer is defined separately for each bit rate. Parameter value 255 (in
means that NRT DCH inactivity supervision is not used.

ChannelSwitching inactivityTimer
30
s
RNC
InactivityTimerUplinkDCH
Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on uplink DCH before release proced
Default values: 8 kbps: 5 s 16 kbps: 5 s 32 kbps: 5 s 64 kbps: 3 s 128
s 256 kbps: 2 s 320 kbps: 2 s 384 kbps: 2 s
ChannelSwitching

20

inactivityTimer

30

RNC

InactivityTimerUplinkDCH128

20

21

22

23

24

25

26

27

Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on uplink DCH before release proced
Timer is defined separately for each bit rate. Parameter value 255 (in
means that NRT DCH inactivity supervision is not used.

ChannelSwitching inactivityTimer
30
s
RNC
InactivityTimerUplinkDCH16
Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on uplink DCH before release proced
Timer is defined separately for each bit rate. Parameter value 255 (in
means that NRT DCH inactivity supervision is not used.

ChannelSwitching inactivityTimer
30
s
RNC
InactivityTimerUplinkDCH256
Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on uplink DCH before release proced
Timer is defined separately for each bit rate. Parameter value 255 (in
means that NRT DCH inactivity supervision is not used.

ChannelSwitching inactivityTimer
30
s
RNC
InactivityTimerUplinkDCH32
Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on uplink DCH before release proced
Timer is defined separately for each bit rate. Parameter value 255 (in
means that NRT DCH inactivity supervision is not used.

ChannelSwitching inactivityTimer
30
s
RNC
InactivityTimerUplinkDCH320
Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on uplink DCH before release proced
Timer is defined separately for each bit rate. Parameter value 255 (in
means that NRT DCH inactivity supervision is not used.

ChannelSwitching inactivityTimer
30
s
RNC
InactivityTimerUplinkDCH384
Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on uplink DCH before release proced
Timer is defined separately for each bit rate. Parameter value 255 (in
means that NRT DCH inactivity supervision is not used.

ChannelSwitching inactivityTimer
30
s
RNC
InactivityTimerUplinkDCH64
Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on uplink DCH before release proced
Timer is defined separately for each bit rate. Parameter value 255 (in
means that NRT DCH inactivity supervision is not used.

ChannelSwitching inactivityTimer
30
s
RNC
InactivityTimerUplinkDCH8
Time not including data transmission, after which UTRAN will send IU
The time indicating how long the radio and transmission resources ar
RELEASE REQUEST message to the CN for UEs in state CELL_FACH. reserved after silence detection on uplink DCH before release proced
Timer is defined separately for each bit rate. Parameter value 255 (in
means that NRT DCH inactivity supervision is not used.

28

RNC
ExtendedULDLactivationTmr
This parameter defines an extended Cell_FACH state inactivity super
time used by the RNC instead of the normal UL_DL_Activation_Time
to a value greater than zero, this value is used for all UEs not support
Cell/URA_PCH state.

RNC

29

UL_DL_activation_timer

29

30

31

32

This timer is used on MAC -c to detect idle periods on data transmiss


(NRT RBs and SRBs) for the UE, which is in Cell_FACH state. Based
timer the MAC -c shall give the No_Data indication to the RRC, which
can change the state of the RRC from Cell_FACH state to the Cell_P
state (or URA_PCH state).

hsdschInactivityTimer 10
ChannelSwitching
s
Timer for sending of IU RELEASE REQUEST message to the CN for
UE connections in RAB state PS Interactive 64/HS - HS-DSCH.

RNC
MACdflowutilTimetoTrigger
This parameter defines the low utilisation time to trigger the timer of t
throughput measurement of the MAC-d flow.

ulRlcBufUpswitch
RNC
256
bytes
Uplink threshold for channel switching from FACH/RACH to dedicated
channel.

RNC
TrafVolThresholdULHigh
The parameter defines the threshold of data in RLC buffer of RB in by
This threshold triggers the uplink traffic volume measurement report w
UE is in a Cell_DCH state and bit rate higher than 16 kbps is allocate
radio bearer. The parameter is sent to the UE using the RRC:
MEASUREMENT CONTROL message.

RNC
MaxCellReselections
Maximum allowed number of Cell Reselections in CELL_FACH or
CELL_PCH state before transition to URA_PCH state. Amount of cel
reselection is counted in both CELL_FACH and CELL_PCH states.

RNC
StandAloneDCCHBitRate
Parameter defines the bit rate to be used for the signalling radio bear
RRC connection establishment. This bit rate is used for RRC signallin
RAB has been established for the RRC connection.

33

34

35

36

37

RNC
TrafVolThresholdULLow
This parameter defines, in bytes, the threshold of data in the RLC buf
SRB0, SRB1, SRB2, SRB3, SRB4 and all NRT RBs that triggers the
traffic volume measurement report, when the UE is in Cell_FACH sta
Otherwise, UE sends data on RACH. This parameter is sent to the UE
an RRC: MEASUREMENT CONTROL message.

RNC
TrafVolThresholdDLLow
This parameter defines, in bytes, the threshold of data in the RLC buf
SRB3, SRB4 and all NRT RBs that triggers the downlink traffic volum
measurement report (capacity request) on MAC, when UE is in Cell_F
state. Otherwise, RNC sends data on FACH.

psStreamingInactivityT
RabHandling
imer
30
s
Timer for monitoring activity on the PS Streaming RAB. When the timer
expires, RNC will request the CN to release the PS Streaming
RAB.1=true, 0=False

38

RNC
MSActivitySupervision
The MSActivitySupervision timer is used in the RRC states CELL_PC
URA_PCH for supervising the inactivity of NRT RAB(s). The timer sta
when a state transition to either state is executed. The MSActivitySup
timer stops when any activity of NRT RAB(s) is detected and the MS
moved to the CELL_FACH or CELL_DCH state.

WCEL

InitialBitRateDL

38

The parameter defines the initial bit rate in the downlink that can be a
by the PS in the schedule situation. The PS does not schedule downl
DCH bit rates that are below the value of this parameter. The allocate
rate corresponds to the highest bit rate in the TFS from which the TFC
constructed. Note: If the maximum bit rate of the RAB is below the va
the minimum allowed bit rate (MinAllowedBitRate) or initial bit rate, it
allowed to schedule a lower NRT DCH bit rate. The maximum bit rate
RAB is used as a new minimum allowed bit rate or initial bit rate for th
connection in question.

39

Rcs
40

41

42

dchRcLostT
50
0.1s
Timer that is started when all radio links for a connection are lost. At
time-out, the radio connection is considered lost.

Rcs

hsDschRcLostT
100 0.1s
Controls the RCS timer for supervision of UL synch of RLS containing
the serving HS-DSCH Radio Link.Special values: 18000 indicates that
the RCS function is switched off. Used for test purposes.

RncFunction

hsOnlyBestCell
TRUE
RNC wide switch for selecting only the best cell for HS.
CoverageRelation

43

hsPathlossThreshold

170
dB
Maximum pathloss allowed for Serving HS-DSCH cell selection to
validate the target cell for selection.
CoverageRelation

44

agpsEnabled

TRUE

Indicates if A-GPS is enabled or not for a cell.


45

47

48

coverageIndicator
1
Defines whether the coverage area of the source cell and the target cell
are indicated to overlap, i.e. approximately the same coverage area, or
whether the coverage area of the target cell is indicated to cover the
source cell or it is contained in the source cell.
ExternalUtranCell

46

WCEL
InitialBitRateUL
The parameter defines the initial bit rate in the uplink that can be alloc
the PS in schedule situation. PS does not schedule uplink NRT DCH
below the value of this parameter. The allocated bit rate corresponds
highest bit rate in the TFS from which the TFCS is constructed. Note:
maximum bit rate of the RAB is below the value of minimum allowed
(MinAllowedBitRateUL) or initial bit rate, it is allowed to schedule a low
DCH bit rate. The maximum bit rate of the RAB is used as a new min
initial bit rate for the RRC connection in question.

WSMLC
NetworkBasedAGPS
This parameter enables and disables Network based AGPS
using the external reference network feature. If the
LCS functionality is disabled, the NW-based A-GPS is
disabled as well.

tCell
UtranCell
Timing delay used for defining start of SCH, CPICH and the DL
scrambling
UtranCell codes. nmo
1
-

WCEL
Tcell
Each cell in a BTS uses a System Frame Number (SFN) counter, wh
the
Number (BFN) counter delayed by a number of chips
RNCBTS Frame
PS_NMO

Default = MODE_II = 1
Network operation mode that indicates whether the Gs interface

In Operation Mode I it is possible to have combined CS and PS side


via SGSN. In Operation Mode II the combined paging procedure is no

att
UtranCell
TRUE
Indicates to the UE whether IMSI attach/detach is allowed.This helps to
facilitate the avoidance of unnecessary paging attempts. The value is
sent on the BCCH.

RNC
CSAttachDetachAllowed
Defines whether IMSI attach and detach are allowed or not. 0 = MSs
apply IMSI attach and detach procedure, 1 = MSs shall apply IMSI at
detach procedure. Parameter is given only for CS domain. (Part of CS
domain specific NAS System information in SIB1.)

WCEL
T312Conn
The timer for supervising successful establishment of a physical chan
MS timer is used in connected mode)

WCEL
N312Conn
This parameter defines the maximum number of "in sync" indications
received from L1 during the establishment of a physical channel (MS
used in connected mode)

WCEL
T313
The radio link failure timer (MS timer).

WCEL
N313
This parameter defines the maximum number of successive "out of s
indications received from L1 (MS counter)

WCEL
N315
This parameter defines the maximum number of successive "in sync"
indications received from L1 while T313 is being activated (UE counte

RNC
T302
The CELL UPDATE/URA UPDATE retransmission timer (MS timer).
RNC
N302
CELL UPDATE/URA UPDATE retransmission counter (MS counter).

49
-

50
51

52
-

53
54
55

56
-

RNC
T307
The timer for transition to idle mode, when the timer T305 has expired
the MS detects an "out of service area" (MS timer)

Nokia
Default

30 min (3)
ate timer (MS timer).

Unit
-

2
s
, a radio link is moved to the Out-of-sync
edure is triggered after a period of time
with a persisting out-of-sync indication.

8
d after a number of consecutive Out-sync
_OUTSYNC_IND are received.

8
er of successive in-sync indications after
ronisation indication procedure. A radio link
a number of consecutive In-sync
_INSYNC_IND.

-2.2
nk target BLER for the reference service in
erence service is used in the determination
annel transmission power.Value of the
R value.

Disabled (0) he redirect feature for emergency calls to


en this parameter is enabled, all emergency
work.

0 s
s the maximum time an inactive MS is
CH state. In the expiry of the timer, the MS
ate if the parameter ToCellFACHinTest is
in the CELL_FACH state continue as
qual to 'No', an Iu release procedure is
o the idle mode.

5 s
adio and transmission resources are
n downlink DCH before release procedures.
s: 5 s 32 kbps: 5 s 64 kbps: 3 s 128 kbps: 2
kbps: 2 s
5 s

adio and transmission resources are


n downlink DCH before release procedures.
ch bit rate. Parameter value 255 (infinity)
upervision is not used.

5 s
adio and transmission resources are
n downlink DCH before release procedures.
ch bit rate. Parameter value 255 (infinity)
upervision is not used.

5 s
adio and transmission resources are
n downlink DCH before release procedures.
ch bit rate. Parameter value 255 (infinity)
upervision is not used.

5 s
adio and transmission resources are
n downlink DCH before release procedures.
ch bit rate. Parameter value 255 (infinity)
upervision is not used.

5 s
adio and transmission resources are
n downlink DCH before release procedures.
ch bit rate. Parameter value 255 (infinity)
upervision is not used.

5 s
adio and transmission resources are
n downlink DCH before release procedures.
ch bit rate. Parameter value 255 (infinity)
upervision is not used.

5 s
adio and transmission resources are
n downlink DCH before release procedures.
ch bit rate. Parameter value 255 (infinity)
upervision is not used.

5 s
adio and transmission resources are
n downlink DCH before release procedures.
ch bit rate. Parameter value 255 (infinity)
upervision is not used.

5 s
adio and transmission resources are
n uplink DCH before release procedures.
s: 5 s 32 kbps: 5 s 64 kbps: 3 s 128 kbps: 2
kbps: 2 s
5 s

adio and transmission resources are


n uplink DCH before release procedures.
ch bit rate. Parameter value 255 (infinity)
upervision is not used.

5 s
adio and transmission resources are
n uplink DCH before release procedures.
ch bit rate. Parameter value 255 (infinity)
upervision is not used.

5 s
adio and transmission resources are
n uplink DCH before release procedures.
ch bit rate. Parameter value 255 (infinity)
upervision is not used.

5 s
adio and transmission resources are
n uplink DCH before release procedures.
ch bit rate. Parameter value 255 (infinity)
upervision is not used.

5 s
adio and transmission resources are
n uplink DCH before release procedures.
ch bit rate. Parameter value 255 (infinity)
upervision is not used.

5 s
adio and transmission resources are
n uplink DCH before release procedures.
ch bit rate. Parameter value 255 (infinity)
upervision is not used.

5 s
adio and transmission resources are
n uplink DCH before release procedures.
ch bit rate. Parameter value 255 (infinity)
upervision is not used.

5 s
adio and transmission resources are
n uplink DCH before release procedures.
ch bit rate. Parameter value 255 (infinity)
upervision is not used.

0 s
ed Cell_FACH state inactivity supervision
he normal UL_DL_Activation_Timer. If set
value is used for all UEs not supporting the
0 s

etect idle periods on data transmission


which is in Cell_FACH state. Based on this
o_Data indication to the RRC, which further
rom Cell_FACH state to the Cell_PCH

0 s
s used in the RRC states CELL_PCH and
ctivity of NRT RAB(s). The timer starts
ate is executed. The MSActivitySupervision
RT RAB(s) is detected and the MS is
LL_DCH state.

0 s
lisation time to trigger the timer of the
AC-d flow.

1024 bytes. 1KB


bytes
(7)
old of data in RLC buffer of RB in bytes.
raffic volume measurement report when the
rate higher than 16 kbps is allocated for the
nt to the UE using the RRC:
sage.

256 bytes
(256)
bytes
he threshold of data in the RLC buffers of
4 and all NRT RBs that triggers the uplink
t, when the UE is in Cell_FACH state.
CH. This parameter is sent to the UE using
ROL message.

256 bytes
(256)
bytes
he threshold of data in the RLC buffers of
at triggers the downlink traffic volume
uest) on MAC, when UE is in Cell_FACH
a on FACH.

20 Reselections in CELL_FACH or
to URA_PCH state. Amount of cell
LL_FACH and CELL_PCH states.

13.6 kbps
be used for the signalling radio bearer at the
his bit rate is used for RRC signalling until a
RRC connection.
-

64 kbps

bit rate in the downlink that can be allocated


n. The PS does not schedule downlink NRT
alue of this parameter. The allocated bit
t rate in the TFS from which the TFCS is
m bit rate of the RAB is below the value of
AllowedBitRate) or initial bit rate, it is
DCH bit rate. The maximum bit rate of the
llowed bit rate or initial bit rate for the RRC

64 kbps
bit rate in the uplink that can be allocated by
does not schedule uplink NRT DCH bit rates
The allocated bit rate corresponds to the
hich the TFCS is constructed. Note: If the
elow the value of minimum allowed bit rate
t rate, it is allowed to schedule a lower NRT
te of the RAB is used as a new minimum or
ion in question.

Disabled (0) bles Network based AGPS


ork feature. If the
NW-based A-GPS is

Frame Number (SFN) counter, which is


unter delayed byNetwork
a number
of chips
defined II (1)
Mode
-of Operation

to have combined CS and PS side paging


he combined paging
IMSIprocedure is not
attach/detac
h allowed (1)

detach are allowed or not. 0 = MSs shall not


cedure, 1 = MSs shall apply IMSI attach and
ven only for CS domain. (Part of CS
rmation in SIB1.)

6
s
ful establishment of a physical channel (this
ode)

1
mum number of "in sync" indications
lishment of a physical channel (MS counter
3

mer).

20
mum number of successive "out of sync"
counter)

1
mum number of successive "in sync"
T313 is being activated (UE counter).

1000
ms
E retransmission timer (MS timer).
7
ransmission counter (MS counter).

30
s
de, when the timer T305 has expired, and
area" (MS timer)

No

Object

Ericsson
Parameter Default

primaryCpichP 300
ower
Power to be used for transmitting the PCPICH.

Nokia
Unit

Object

Parameter

UtranCell

0.1dBm

UtranCell
2

bchPower
-31
0.1 dB
BCH power is the power to be used for transmitting on the
BCH, relative to the primaryCpichPower value.

WCEL
PtxPrimaryCPICH
This is the transmission power of the primary common pilot channel.The P-CPI
physical channel carries the common pilots of the cell, which is defined in the c
The transmission power of the CPICH physical channel defines the actual cell s
means that the power is determined by radio network planning. The default valu
10% of the maximum transmitting power of WCDMA BTS
WCEL

PtxPrimaryCCPCH

BCH Power. This is the transmission power of the primary CCPCH relative to th
transmission power.

primarySchPo
wer
UtranCell
12
dB
WCEL
PtxPrimarySCH
Primary SCH power, relative to the primaryCpichPower value. This is the transmission power of the primary synchronisation channel. The pow
relative to the [FDD-primary CPICH power]. The primary SCH consists of a mod
code 256 chips in length: the Primary Synchronisation Code (PSC) transmitted
every slot. The PSC is the same for every cell in the system, and it enables the
slot synchronisation in the cell.
UtranCell

secondarySch
Power
-35
0.1dB
Secondary SCH power, relative to the primaryCpichPower
value.
4

aichPower
Rach
-6
dB
AICH power, to be used for transmitting on AICH, relative to
the primaryCpichPower value.

WCEL
PtxAICH
This is the transmission power of one Aquisition Indicator (AI) compared to CPI
power.

Fach

maxFach1Pow 18
er
0.1dB
Maximum power, to be used for transmitting the first FACH
channel, relative the primaryCpichPower value. The first
FACH is used for logical channels BCCH, CCCH and DCCH,
control signaling.

WCEL
PtxSecSCH
This is the transmission power of the secondary synchronisation channel relate
Primary CPICH transmission power. The secondary SCH consists of repeatedly
transmitting a length 15 sequence of modulated codes 256 chips in length. The
Secondary Synchronisation Codes (SSC), transmitted in parallel with the prima
This sequence on the secondary SCH enables the downlink frame synchronisa
indicates, to which code group the cell downlink scrambling code belongs.

Fach

WCEL
PtxSCCPCH1
This is the transmission power of the S-CCPCH channel, which carries a PCH
(containing PCCH), a FACH (containing DCCH/BCCH/CCCH) and a FACH (con
DTCH). Or alternatively (when standalone PCH is mapped to an another S-CCP
carries a FACH (containing DCCH/BCCH/CCCH) and a FACH (containing DTC
transmission power value is relative to the CPICH transmission power.

maxFach2Pow 15
0.1dB
er
Maximum power, to be used for transmitting the second FACH
channel, relative the primaryCpichPower value. The second
FACH is used for logical channel DTCH, traffic signaling.
-

pchPower
Pch
-4
dB
Maximum power to be used for transmitting the PCH, relative
to the primaryCpichPower value.

WCEL
PtxSCCPCH2
This is the transmission power of the S-CCPCH channel, which carries PCH (co
PCCH) only. This parameter is not needed if PCH and FACH's are multiplexed
S-CCPCH.

pichPower
Pch
-7
dB
PICH power is the power to be used for transmitting on the
physical channel carrying the paging indicators, relative to the
primaryCpichPower value.

WCEL
PTxPICH
This is the transmission power of the PICH channel. It carries the paging indica
tell the UE to read the paging message from the associated secondary CCPCH
transmission power value is relative to the CPICH transmission power.

Fach
10

11

pOffset1Fach
0 0.25 dB
Power offset for the TFCI. This parameter is applied to both
FACH and PCH. Disturbances: Changing this attribute may
affect ongoing traffic.Whenever its value is set, the FACH is
disabled automatically and then re-enabled.

WCEL
PowerOffsetSCCPCHTFCI
Defines the power offset for the TFCI symbols relative to the downlink transmis
power of a Secondary CCPCH. The TFCI field is offset relative to the power of
field. The power offsets vary in time according to the bit rate. Proposed values a
for 15 ksps; 3 dB for 30 ksps; and 4 dB for 60 ksps.

Fach

pOffset3Fach

0 0.25 dB
Power offset for the pilot. This parameter is applied to both
FACH and PCH. Disturbances: Changing this attribute may
affect ongoing traffic.Whenever its value is set, the FACH is
disabled automatically and then re-enabled.
Rach

12

constantValue
Cprach
-27 dB
Constant value used by the UE to calculate the initial power
on PRACH according to the Open loop power control
procedure.

Rach
13

maxPreamble
Cycle
4
Maximum number of preamble ramping cycle.

Rach
14

WCEL
RACH_tx_Max
Maximum number of RACH preamble cycles defines how many times the PRAC
amble ramping procedure can be repeated before UE MAC reports a failure on

powerOffsetP0

3 dB
Power step when no acquisition indicator is received.

Rach
15

powerOffsetPp
m
-4 dB
Power step between preamble and the message part.

WCEL
PowerRampStepPRACHpreamble
The power ramp step on PRACH preamble when no acquisition indicator (AI) is
by the UE

WCEL
PowerOffsetLastPreamblePRACHmessage
The power offset between the last transmitted preamble and the control part of
PRACH message (added to the preamble power to receive the power of the me
control part).

Rach
16

17

18

preambleRetra
nsMax
8
Maximum number of preambles in one preamble ramping
cycle.

WCEL
PRACH_preamble_retrans
The maximum number of preambles allowed in one preamble ramping cycle.

PowerControl

dlInitSirTarget

41 0.1dB

Required DL Initial SIR target for all RABs.

PowerControl

cBackOff
0 0.25dB
Used to back off the open loop power control estimate to a
conservative starting point.
PowerControl

19

20

21

ecNoPcpichDe
fault
-16 dB
The default value to be used in power calculations for Ec
divided by No.
dlPcMethod
PowerControl
65
dB
Selects the DL power control method at establishment of the
radio connection. sirMin
PowerControl
-82 0.1dB
The minimum allowed SIR target.
PowerControl

sirMax
100 0.1dB
The maximum allowed SIR target for 10 ms TTI users.
22

23

RNC
PowerBalancing
This parameter defines whether Power Balancing is used or not.

WBTS
SIRDPCCHInitialDCHMin
This parameter defines the minimum SIR target value for the UL DPCCH when
link
only has DCHs
configured in the uplink transfer direction. Minimum value o
WBTS
SIRDPCCHInitialDCHMax

This parameter defines the maximum SIR target value for the UL DPCCH when
link only has DCHs configured in the uplink transfer direction. Maximum value o
target is achieved by adding the value of the parameter to the initial SIR target
WBTS

DLTPCPatternPowerCount

23

24

RNC
StepSizeForDCHBLER
Weighting coefficient which defines how big the DCH BLER target impact to the
SIR is during the DCH Outer Loop Power Control Entity calculation.

RNC
MinPrefChange
When RNC calculates a new reference power for base stations, it is not update
base stations if it does not differ from the existing reference power in the base s
least by a value defined by this parameter.

RNC
AdjustmentPeriod
This parameter defines the period during which the DL transmitted power has to
corrected to the reference power. Setting this parameter to a small value makes
balancing faster, whereas setting it to a large value makes it slower.

RNC
AdjustmentRatio
This parameter defines the convergence rate (towards the reference power) use
associated Adjustment Period.If the value is zero, power is corrected to the DL
power.

RNC
MaxAdjustmentStep
Defines a time period (in terms of a number of slots) during which the accumula
adjustment will be no more than 1dB. This value does not include the DL inner
adjustment. A small amount of slots grants quick response times for power bala
may cause overestimations.

28

27

26

25

This parameter is used to calculate the value of IE DL TPC pattern 01 count, w


used when the uplink is out of synchronisation and the first radio link set toward
is set up. The computed IE is used to generate a sequence of TPC commands
progressively increase the UL DPCCH power by 0-24 dB over a four frame peri
sequences are repeated until synchronisation has been achieved.

Nokia
Default

Unit

33
dBm
he primary common pilot channel.The P-CPICH
mon pilots of the cell, which is defined in the cell setup.
ICH physical channel defines the actual cell size, which
ed by radio network planning. The default value is 5power of WCDMA BTS
-5 dB

on power of the primary CCPCH relative to the CPICH

-3
dB
he primary synchronisation channel. The power level is
H power]. The primary SCH consists of a modulated
ary Synchronisation Code (PSC) transmitted once
or every cell in the system, and it enables the downlink

-3
dB
he secondary synchronisation channel related to the
er. The secondary SCH consists of repeatedly
of modulated codes 256 chips in length. These are the
s (SSC), transmitted in parallel with the primary SCH.
SCH enables the downlink frame synchronisation, and
cell downlink scrambling code belongs.

-8
dB
one Aquisition Indicator (AI) compared to CPICH

0 dB
he S-CCPCH channel, which carries a PCH
aining DCCH/BCCH/CCCH) and a FACH (containing
ndalone PCH is mapped to an another S-CCPCH)
/BCCH/CCCH) and a FACH (containing DTCH).The
e to the CPICH transmission power.

0
dB
he S-CCPCH channel, which carries PCH (containing
needed if PCH and FACH's are multiplexed into same

-8
dB
he PICH channel. It carries the paging indicators which
sage from the associated secondary CCPCH. The
e to the CPICH transmission power.

2 dB
FCI symbols relative to the downlink transmission
e TFCI field is offset relative to the power of the data
e according to the bit rate. Proposed values are: 2 dB
4 dB for 60 ksps.
-

8
mble cycles defines how many times the PRACH preepeated before UE MAC reports a failure on RACH

2 dB
preamble when no acquisition indicator (AI) is detected

2 dB
transmitted preamble and the control part of the
eamble power to receive the power of the message

8 es allowed in one preamble ramping cycle.

0 (=Power Balancing is
not in use)
ower Balancing is used or not.

um SIR target value for the UL DPCCH when the radio


he uplink transfer6 direction.
Minimum value
dB
- of the SIR

um SIR target value for the UL DPCCH when the radio


he uplink transfer direction. Maximum value of the SIR
alue of the parameter to the initial SIR target value
3

e the value of IE DL TPC pattern 01 count, which is


chronisation and the first radio link set towards the UE
d to generate a sequence of TPC commands which
CCH power by 0-24 dB over a four frame period. These
hronisation has been achieved.

0.3
dB
s how big the DCH BLER target impact to the Delta
Power Control Entity calculation.

3
dB
ence power for base stations, it is not updated to the
om the existing reference power in the base stations at
rameter.

2
frame
during which the DL transmitted power has to be
Setting this parameter to a small value makes power
t to a large value makes it slower.

0
dB
gence rate (towards the reference power) used for the
e value is zero, power is corrected to the DL reference

8
slot
a number of slots) during which the accumulated power
dB. This value does not include the DL inner loop PC
ts grants quick response times for power balancing but

No

Ericsson
Parameter

Object

Nokia
Default

Unit

maximumTransmissionPower
UtranCell
400 0.1 dBm
WCEL
Maximum power for all downlink channels added together, that is allowed Maximum value for the linear sum of the power of all downlink physi
to be used simultaneously in a cell
to be used in a cell. The maximum transmission power of the cell is
parameters: PtxCellMax and MaxDLPowerCapability (the maximum

Hsdsch

numHsPdschCodes

5 -

WCEL

Number of codes of SF=16 used for the HS-PDSCH.

This parameter defines the HS-PDSCH code set. If the HSDPA dyn
functionality cannot be used or it is deactivated, the code set contain
code amount (5). If the HSDPA dynamic code allocation functionalit
activated, the code set contains more than one code amounts

UtranCell

aseDlAdm
240 ASE
Admission limit for admission on max capacity (ASE level) in DL. Used by
Admission Control in subfunction Admission Request Handler.

UtranCell

Object

aseUlAdm

160 ASE
Admission limit for admission on max capacity (ASE level) in UL. Used by
Admission
in subfunction Admission Request Handler.
UtranCell Control
hsdpaUsersAdm
10

Admission limit for the number of users assigned to the HS-PDSCH/HSSCCH in the cell. This limit is applicable both to HSDPA RAB setup and
to channel switching.

UtranCell

compModeAdm

15
Admission limit for number of RL in compressed mode in a cell.

UtranCell

dlCodeAdm

80 %
Admission limit used for admission based on DL channelization code tree
usage (percentage of the tree in use).Used by Admission Control in
subfunction Admission Request Handler.

UtranCell
pwrAdm
80 %
Admission limit for admission on DL cell carrier power.Rule: pwrAdm +
pwrAdmOffset + pwrOffset <= 100% ; pwrAdm >= beMarginDlPwr

WCEL
Maximum power for all downlink channels added together, that is all

UtranCell
pwrAdmOffset
Relative admission limit on DL cell carrier power. Rule:
pwrAdm+pwrAdmOffset+pwrOffset <= 100%

WCEL
The target value of the total transmitted power (PtxTarget) can be ex
parameter before the cell is considered to be overloaded in downlink
not admitted, if the total transmitted power exceeds the sum of the v
the PtxTarget. PtxOffset is used to calculate the first downlink overlo
RNC: PtxTargetBTS = PtxTarget+PrxOffset.

10 %

UtranCell

10

sf8Adm

10

Admission policy for admission on the number of Spreading Factor = 8


(traffic class=non-guaranteed, setup type=<all>) simultaneous
connections in a cell in DL (SF histogram).
Default setting is to disable the admission policy. Actual setting can
deviate from the default to limit the number of simultaneous high-bitrate
connections in a cell, typically to deal with limitations in the Transport
Network dimensioning (i.e. prevent all TN resources from being claimed
by the non-guaranteed traffic class connections).
Used by Admission Control in subfunction Admission Request Handler.

11

UtranCell

sf16Adm

16
Admission policy for admission on the number of Spreading Factor = 16
(traffic class=non-guaranteed, setup type=<all>) simultaneous
connections in a cell in DL (SF histogram).
Default setting is to disable the admission policy. Actual setting can
deviate from the default to limit the number of simultaneous high-bitrate
connections in a cell, typically to deal with limitations in the Transport
Network dimensioning (i.e. prevent all TN resources from being claimed
by the non-guaranteed traffic class connections).
Used by Admission Control in subfunction Admission Request Handler.

UtranCell

sf32Adm

UtranCell

sf16gAdm

16
Maximum number of radio links with Spreading Factor (SF) =16 in DL for
which new guaranteed admission requests will continue to be allowed.
Reaching or exceeding this number of radio links (any service class)
using DL SF = 16 will block setup/adding any more guaranteed service
class radio links requiring additional DL SF=16 for this cell.

UtranCell

sf4AdmUl

0
Admission limit (traffic class = non-guaranteed, admission class =
handover or other) for number of radio links with UL SF = 4.

UtranCell

sf8AdmUl

8
Admission limit (traffic class = non-guaranteed, admission class =
handover or other) for number of radio links with UL SF = 8.

UtranCell

sf16AdmUl

16
Admission limit (traffic class = non-guaranteed, admission class =
handover or other) for number of radio links with UL SF = 16.

UtranCell

sf8gAdmUl

12

16
Admission policy for admission on the number of Spreading Factor = 32
(traffic class=non-guaranteed, setup type=<all>) simultaneous
connections in a cell in DL (SF histogram).
Default setting is to disable the admission policy. Actual setting can
deviate from the default to limit the number of simultaneous high-bitrate
connections in a cell, typically to deal with limitations in the Transport
Network dimensioning (i.e. prevent all TN resources from being claimed
by the non-guaranteed traffic class connections). Note also that multiRAB (speech + packet) is considered to be a non-guaranteed traffic class
connection and is affected by this admission policy.Used by Admission
Control in subfunction Admission Request Handler.

13

14

15

16

17

18

8
Admission limit for RLs with spreading factor (SF) = 8 in UL (guaranteed
admission requests).
IubLink
dlHwAdm
100 %
Admission limit on RBS DL HW resource utilisation applicable to all
admission requests.

IubLink
19

20

ulHwAdm
100 %
Admission limit on RBS UL HW resource utilisation applicable to all
admission requests.

UtranCell

WCEL
The target for received total wideband interference power in a cell. A
admitted if the estimated non-controllable power exceeds this thresh
to calculate PrxTargetBTS, which is the first overload threshold for B
value of the PrxTarget is relative to the system noise; it gives an upp

iFCong

621
Threshold at which UL congestion is detected in the cell.
Default setting is to disable UL congestion measurements, in order to
prevent problems during upgrading.
UtranCell

21

iFHyst
6000 10ms
Hysterese time setting for detection of congestion in the UL RTWP in a
cell. The measured value has to be above the detection level (iFCong) for
more than iFHyst time before the situation is detected as congestion. In
the same way, UL congestion is considered to be resolved when the
measured value is below the resolve level (ifCong - iFOffset) for more
than iFHyst time (unless resolving of congestion is indicated earlier by
one of the periodic measurement reports). Default setting is to disable UL
congestion measurements, in order to prevent problems during
upgrading. Actual setting depends on the duration of peaks in UL RTWP
influenced by UE behaviour and power control settings (causes 'false'
congestion detection).

22

UtranCell

pwrHyst

300 ms
Hysterese time setting for detection of congestion in the DL transmitted
carrier power. The measured value has to be above the detection level
(pwrAdm + pwrOffset) for more than pwrHyst time before the situation is
detected as DL cell congestion. In the same way, DL cell congestion is
considered to be resolved when the measured value is below the resolve
level (pwrAdm) for more than pwrHyst time (unless resolving of
congestion is indicated earlier by one of the periodic measurement
reports). Default setting is to avoid false DL cell congestion detection.
Actual setting can deviate from the default depending on the duration of
peaks in DL transmitted carrier power influenced by UE behaviour and
power control settings (causes 'false' DL cell congestion detection).Used
by Congestion Control.

UtranCell

pwrOffset

5 %
Used by Congestion Control. Dependencies: pwrAdm + pwrOffset <= 100
%

UtranCell

releaseAseDl

1 ASE
Amount of ASE in DL to be released with each periodic congestion
resolve action targeting guaranteed traffic class connections in a cell.
Default setting is a reference case setting. Actual setting can deviate from
the default depending on the required speed to resolve the DL cell
congestion situation and the characteristics of the guaranteed traffic class
services in the network.
Used by Congestion Control.

UtranCell

releaseAseDlNg

3 ASE
Amount of ASE in DL to be released with each periodic congestion
resolve action targeting non-guaranteed traffic class connections in a cell.
Default setting is a reference case setting. Actual setting can deviate from
the default depending on the required speed to resolve the DL cell
congestion situation and the characteristics of the non-guaranteed traffic
class services in the network.Used by Congestion Control.

UtranCell

tmCongAction

23

24

25

26

2000 ms

26

27

28

Interval between periodic congestion resolve actions on guaranteed traffic


class connections in a cell. Default setting is a reference case setting.
Actual setting can deviate from the default depending on the required
speed to resolve the DL cell congestion situation and the characteristics
of the guaranteed traffic class services in the network.Used by
Congestion Control.

UtranCell

tmCongActionNg

800 ms
Interval between periodic congestion resolve actions on non-guaranteed
traffic class connections in a cell. Default setting is a reference case
setting. Actual setting can deviate from the default depending on the
required speed to resolve the DL cell congestion situation and the
characteristics of the non-guaranteed traffic class services in the
network.Used by Congestion Control.

UtranCell

tmInitialG

3000 ms
Minimum time before congestion resolve actions are initiated on
guaranteed traffic class connections in a cell (after detection of DL cell
congestion).Default setting is a reference case setting. Actual setting can
deviate from the default depending on the required speed to resolve the
DL cell congestion situation and the characteristics of the non-guaranteed
traffic class services in the network.Used by Congestion Control.

WCEL
Parameter defines the target scheduling threshold for HSDPA powe
to the HSDPA static resource allocation in RNC and ignored in the c
resource allocation. Depending on the setting of the parameter HSD
transmitted carrier power or the total non-controllable transmitted po
equal to PtxTargetHSDPA before the first HS-DSCH MAC-d flow ca
at least one HS-DSCH MAC-d flow is allocated in the cell, PtxTarge
PtxTarget as a target of PtxnonHSDPA in NRT DCH scheduling. If H
allocation is active, value of the parameter PtxMaxHSDPA added wi
parameter PtxTargetHSDPA must not exceed the cell maximum tran
the minimum of the following parameters: PtxCellMax and MaxDLPo
WCEL
This parameter defines the maximum allowed target level for DCH p
or more MAC-d flows is set up in the cell. The target level is determi
adjusted PtxTargetPS when HSDPA dynamic resource allocation is

29

30

WCEL
Parameter defines the maximum allowed HSDPA transmission pow

WCEL
This parameter defines the maximum downlink user bit rate allowed
domain RAB.

WCEL
Defines the noise level in the BTS digital receiver when there is no l
figure). This parameter is needed in noise rise calculations.

WCEL
This parameter defines how measurement values should be filtered
common measurement of the received total wideband power in a ce
value 2 means that both an old filtered measurement and a new me
of 50%. This is an appropriate default value when the measurement
reporting period 200 ms (two measurements to be filtered). A high v
emphasises the old filtered measurement result. A low value empha
measurement result. With value 0, old measurements are not consi
concerns 3GPP-specified NBAP-interface only.

WCEL

32

33

34

35

31

35

36

WCEL
This parameter defines the adjustment period - in terms of PtxTotal/
periods - of the target level for DCH packet scheduling (PtxTargetPS
flows is/are set up in the cell when HSDPA dynamic resource alloca
Conditions to adjust PtxTargetPS are checked every nth received m
BTS, where n is defined by this parameter.

WCEL
The target value of the total received power (PrxTarget) can be exce
parameter before the cell is considered to be overloaded in uplink. R
admitted if the total received power exceeds the sum of the values o
PrxTarget. PrxOffset is used to calculate the first uplink overload thr
PrxTargetBTS = PrxTarget+PrxOffset.

WCEL
Parameter is applicable to the HSDPA static resource allocation.The
transmitted non-HSDPA power (PtxTargetHSDPA) can be exceeded
parameter before the cell is considered to be overloaded in the dow
PtxNonHSDPA exceeds or equals PtxTargetHSDPA + PtxOffsetHSD
setting of the parameter HSDPAPriority, overload control actions tar
MAC-d flows or NRT DCHs are started.

37

38

This parameter defines how measurement values should be filtered


common measurement of the received total transmitted carrier powe
default value 2 means that both an old filtered measurement and a n
weight of 50%. This is an appropriate default value when the measu
and the reporting period 200 ms (two measurements to be filtered).
parameter emphasises the old filtered measurement result. A low va
measurement result. With value 0, old measurements are not consi
concerns 3GPP-specified NBAP-interface only.

Nokia
Parameter

Default

Unit

PtxCellMax
43
dBm
Maximum value for the linear sum of the power of all downlink physical channels that is allowed
to be used in a cell. The maximum transmission power of the cell is the minimum of the two
parameters: PtxCellMax and MaxDLPowerCapability (the maximum BTS power capability).

HSPDSCHCodeSet
This parameter defines the HS-PDSCH code set. If the HSDPA dynamic code allocation
functionality cannot be used or it is deactivated, the code set contains just one
code amount (5). If the HSDPA dynamic code allocation functionality can be used and it is
activated, the code set contains more than one code amounts

PtxTarget
42
dBm
Maximum power for all downlink channels added together, that is allowed to be used in a cell

PtxOffset
0.5
dB
The target value of the total transmitted power (PtxTarget) can be exceeded by the value of this
parameter before the cell is considered to be overloaded in downlink. Radio Access Bearer is
not admitted, if the total transmitted power exceeds the sum of the values of this parameter and
the PtxTarget. PtxOffset is used to calculate the first downlink overload threshold for BTS and
RNC: PtxTargetBTS = PtxTarget+PrxOffset.

PrxTarget
30 dB
The target for received total wideband interference power in a cell. An uplink RT RAB is not
admitted if the estimated non-controllable power exceeds this threshold. PrxTarget is also used
to calculate PrxTargetBTS, which is the first overload threshold for BSUL interference. The
value of the PrxTarget is relative to the system noise; it gives an upper threshold for the noise

PtxTargetHSDPA
42
dBm
Parameter defines the target scheduling threshold for HSDPA power allocation. It is applicable
to the HSDPA static resource allocation in RNC and ignored in the case of HSDPA dynamic
resource allocation. Depending on the setting of the parameter HSDPAPriority, either the total
transmitted carrier power or the total non-controllable transmitted power has to be below or
equal to PtxTargetHSDPA before the first HS-DSCH MAC-d flow can be allocated in the cell. If
at least one HS-DSCH MAC-d flow is allocated in the cell, PtxTargetHSDPA is used instead of
PtxTarget as a target of PtxnonHSDPA in NRT DCH scheduling. If HSDPA static resource
allocation is active, value of the parameter PtxMaxHSDPA added with the value of the
parameter PtxTargetHSDPA must not exceed the cell maximum transmission power defined by
the minimum of the following parameters: PtxCellMax and MaxDLPowerCapability. Otherwise
PtxTargetPSMax
40
dBm
This parameter defines the maximum allowed target level for DCH packet scheduling when one
or more MAC-d flows is set up in the cell. The target level is determined by the dynamically
adjusted PtxTargetPS when HSDPA dynamic resource allocation is used in the cell.

PtxMaxHSDPA
42
Parameter defines the maximum allowed HSDPA transmission power.

dBm

MaxBitRateDLPSNRT
384 kbps
This parameter defines the maximum downlink user bit rate allowed in a cell for an NRT PS
domain RAB.
PrxNoise
-101.9 dBm
dBm
Defines the noise level in the BTS digital receiver when there is no load (thermal noise + noise
figure). This parameter is needed in noise rise calculations.
PrxMeasFilterCoeff
2 This parameter defines how measurement values should be filtered before Node B reports the
common measurement of the received total wideband power in a cell to the RNC.The default
value 2 means that both an old filtered measurement and a new measurement have the weight
of 50%. This is an appropriate default value when the measurement period is 100 ms and the
reporting period 200 ms (two measurements to be filtered). A high value of this parameter
emphasises the old filtered measurement result. A low value emphasises the new
measurement result. With value 0, old measurements are not considered. This parameter
concerns 3GPP-specified NBAP-interface only.
PtxMeasFilterCoeff

2 -

This parameter defines how measurement values should be filtered before Node B reports the
common measurement of the received total transmitted carrier power in a cell to the RNC. The
default value 2 means that both an old filtered measurement and a new measurement have the
weight of 50%. This is an appropriate default value when the measurement period is 100 ms
and the reporting period 200 ms (two measurements to be filtered). A high value of this
parameter emphasises the old filtered measurement result. A low value emphasises the new
measurement result. With value 0, old measurements are not considered. The parameter
concerns 3GPP-specified NBAP-interface only.
PtxTargetPSAdjustPeriod
10
s
This parameter defines the adjustment period - in terms of PtxTotal/PtxNonHSPA reporting
periods - of the target level for DCH packet scheduling (PtxTargetPS) when one or more MAC-d
flows is/are set up in the cell when HSDPA dynamic resource allocation is used in the cell.
Conditions to adjust PtxTargetPS are checked every nth received measurement report from the
BTS, where n is defined by this parameter.
PrxOffset
6
dB
The target value of the total received power (PrxTarget) can be exceeded by the value of this
parameter before the cell is considered to be overloaded in uplink. Radio Access Bearer is not
admitted if the total received power exceeds the sum of the values of this parameter and the
PrxTarget. PrxOffset is used to calculate the first uplink overload threshold for BTS and RNC:
PrxTargetBTS = PrxTarget+PrxOffset.
PtxOffsetHSDPA
0.5
dB
Parameter is applicable to the HSDPA static resource allocation.The target value of the
transmitted non-HSDPA power (PtxTargetHSDPA) can be exceeded by the value of this
parameter before the cell is considered to be overloaded in the downlink. If the averaged
PtxNonHSDPA exceeds or equals PtxTargetHSDPA + PtxOffsetHSDPA, depending on the
setting of the parameter HSDPAPriority, overload control actions targeted either to HS-DSCH
MAC-d flows or NRT DCHs are started.

Ericsson
No

Object

Nokia

Parameter

Default

Unit

Object

Parameter

Hsdsch
operationalState
ENABLED (1) The operational state of the HSDPA resources in the cell.

WCEL
HSDPAenabled
The parameter enables / disables the use of HSDPA in the cell. If the
parameter is enabled (1) the system checks that the maximum amount o
HSDPA-capable BTSs and cells is not exceeded. If it is not possible to
activate HSDPA for a new BTS or cell then the activation does not succe
and error is printed out.

WCEL
MaxNbrOfHSSCCHCodes
This parameter defines the maximum number of HS-SCCH codes (SF 12
that can be reserved in one cell. More than one HS-SCCH code can be u
if the HSDPA code multiplexing functionality is in use. The actual numbe
reserved codes depends on for example HSDPA capabilities and HSDPA
code multiplexing support (RNC and BTS).

Carrier
hsPowerMargin
2 dB
The power margin the HSDPA scheduling is using when allocating
the remaining power of the cell carrier.
The margin is relative the maximum available power (Maximum
Transmission Power) of the RbsLocalCell.

Carrier
supportOf16qam
TRUE
This parameter controls the 16QAM support in the cell. If set to
TRUE, the capability of the UE decides whether 16QAM or QPSK is
used.

Hsdsch
cqiFeedbackCycle
8 ms
The duration of the CQI feedback cycle on HS-DPCCH.

Hsdsch
initialCqiRepetitionFactor
1
The initial number of repetitions for CQI report messages on HSDPCCH.
Must be set less than or equal to cqiFeedbackCycle / 2ms.
Hsdsch
initialAckNackRepetitionFactor
1
The initial number of repetitions for ACK/NACK feedback
transmissions on HS-DPCCH.

Hsdsch
deltaCqi1
4
The power offset for CQI report messages on HS-DPCCH for UE
Connections using one RLS.

Hsdsch
deltaCqi2
6
The power offset for CQI report messages on HS-DPCCH for UE
Connections using two or more RLSs.

10

Hsdsch
deltaAck1
5
The power offset for acknowledgement messages on HS-DPCCH for
UE Connections using one RLS.
Hsdsch
deltaAck2
7
The power offset for acknowledgement messages on HS-DPCCH for
UE Connections using two or more RLSs.
-

11

Hsdsch
deltaNack1
5
The power offset for non-acknowledgement messages on HSDPCCH for UE Connections using one RLS.

12

13

Hsdsch
deltaNack2
7
The power offset for non-acknowledgement messages on HSDPCCH for UE Connections using two or more RLSs.
Carrier

14

hsScchMaxCodePower

-20 0.1dB

14

HS-SCCH maximum code power relative PCPICH reference power.


This parameter also determines the fixed power level for HS-SCCH.
RncFunction hsCellChangeAllowed
TRUE (1)
Overall On/Off switch for serving HS-DSCH cell change

15

16
-

RNC
HSDPAMobility
Parameter enables/disables serving HS-DSCH cell change & SHO of the
associated DPCH.
If the value is disabled, basic mobility handling with switching to FACH/D
is utilised. If the value is enabled, SHO of the associated DPCH and serv
HS-DSCH cell change are utilised.

DirectedRRCForHSDPALay
erEnabled
WCEL
Enables / disables the use of the Directed RRC connection setup for the
HSDPA layer in the cell.

WCEL
SectorID
This parameter gives a unique identifier to a sector of the base station w
the cell belongs to. The RNC uses the sector identifier in order to integra
cells (carrier frequencies) which have equal coverage areas within one b
station. A cell does not belong to any particular sector when the value of
sector indentifier is zero

DRRCprxOffset
WCEL
This parameter determines the threshold level which the uplink load of th
source cell must exceed before the Admission control of the RNC may d
the RRC connection setup to another cell within the sector. The Admissio
control calculates the threshold level by adding the value of the paramete
the target value of the total received power (PrxTarget)

WCEL

17
-

18

DirectedRRCEnabled
WCEL
The parameter enables/disables the use of the directed RRC connection
setup in the cell.

DirectedRRCForHSDPALay
erEnhanc
RNC
When this parameter is enabled and the Directed RRC connection setup
HSDPA layer is enabled (DirectedRRCForHSDPALayerEnabled parame
enabled) in the cell, the following enhancements are in use:
1. The RNC takes into account the service requested in the RRC connec
request when making the decision of Directed RRC connection setup to
HSDPA layer. The services are defined with the
DRRCForHSDPALayerServices parameter.
2. The RNC supports more than 2 layers.
3. The RNC supports HSDPA load sharing between layers.
4. The RNC supports simultaneous use of Directed RRC Connection Se
and Directed RRC Connection Setup for HSDPA layer features (the
DirectedRRCEnabled and DirectedRRCForHSDPALayerEnabled parame
are enabled).

19

20

21

DRRCptxOffset

This parameter determines the threshold level which the downlink load o
source cell must exceed before the Admission control of the RNC may d
the RRC connection setup to another cell within the sector. The Admissio
control calculates the threshold level by adding the value of the paramete
the target value of the total transmitted power (PtxTarget)

21

DRRCprxMargin
WCEL
This parameter determines the threshold level which the uplink load of th
may not exceed in order for the Directed RRC Connection Setup to be
possible from another cell (source cell) of the same sector. The Admissio
control of the RNC calculates the threshold level by adding the value of t
parameter to the total received power level of the source cell.

DRRCptxMargin
WCEL
This parameter determines the threshold level which the downlink load o
cell may not exceed in order for the Directed RRC Connection Setup to b
possible from another cell (source cell) of the same sector. The Admissio
control of the RNC calculates the threshold level by adding the value of t
parameter to the total transmitted power level of the source cell.

22

23

Nokia
Default

Unit

Enabled(1)
sables the use of HSDPA in the cell. If the
e system checks that the maximum amount of
cells is not exceeded. If it is not possible to
BTS or cell then the activation does not succeed

3 maximum number of HS-SCCH codes (SF 128)


cell. More than one HS-SCCH code can be used
xing functionality is in use. The actual number of
n for example HSDPA capabilities and HSDPA
RNC and BTS).
-

Enabled(1)
s serving HS-DSCH cell change & SHO of the

ic mobility handling with switching to FACH/DCH


abled, SHO of the associated DPCH and serving
utilised.

1 carrier:
0(disabled),
2 carriers F1
Enabled(1) and F2
Disable(0)
of the Directed RRC connection setup for the

1 carrier site:
Disable(0)
2 carriers site:
Enabled(1) for both
F1&F2
ables the use of the directed RRC connection

Enabled(1)
abled and the Directed RRC connection setup for
irectedRRCForHSDPALayerEnabled parameter is
owing enhancements are in use:
ount the service requested in the RRC connection
ecision of Directed RRC connection setup to
are defined with the
vices parameter.
than 2 layers.
PA load sharing between layers.
taneous use of Directed RRC Connection Setup
ion Setup for HSDPA layer features (the
DirectedRRCForHSDPALayerEnabled parameters

sector 1=1
sector 2=2
sector 3=3
sector 6=1
sector 7=2
sector 8=3
que identifier to a sector of the base station where
C uses the sector identifier in order to integrate
which have equal coverage areas within one base
ong to any particular sector when the value of the

-1 dB
the threshold level which the uplink load of the
fore the Admission control of the RNC may direct
to another cell within the sector. The Admission
hold level by adding the value of the parameter to
received power (PrxTarget)

-3 dB

the threshold level which the downlink load of the


fore the Admission control of the RNC may direct
to another cell within the sector. The Admission
hold level by adding the value of the parameter to
transmitted power (PtxTarget)

0 dB
the threshold level which the uplink load of the cell
the Directed RRC Connection Setup to be
source cell) of the same sector. The Admission
es the threshold level by adding the value of the
ved power level of the source cell.

-0.5 dB
the threshold level which the downlink load of the
er for the Directed RRC Connection Setup to be
source cell) of the same sector. The Admission
es the threshold level by adding the value of the
mitted power level of the source cell.

Ericsson
No

Object

Nokia

Parameter

Default

Unit

Object

UeMeasControl
filterCoefficient1
2
Coefficient for layer 3 filtering before intra-frequency reporting evaluation.

UeMeasControl
measQuantity1
2=EcNo
Used by UE functions for intra-frequency measurements (in CELL_DCH). Quantity
to measure for the chosen mode. The value of this attribute will set the message
data CPICH_Ec/No or CPICH_RSCP accordingly
-

Handover
maxActiveSet
3
Maximum number of cells in active set.This attribute also controls the reporting
deactivation threshold, used to control intra-frequency measurements (event
1a).reporting deactivation threshold = maxActiveSet-1.The attribute also controls
the replacement activation threshold, used to control intra-frequency
measurements (event 1c).replacement activation threshold = maxActiveSet

FMCS
This parameter determines the maximum number of cells
soft/softer handover.

UtranCell
individualOffset
0
dB
Used in UE function event-reporting. This offset is added to the measured quantity
before the UE evaluates if an event has occured.
-

ADJS
The CPICH Ec/No Offset determines an offset value, whic
Ec/No measurement result of the neighbouring cell before
with the reporting criteria

RNC
This parameter indicates a user plane procedure support o
information is given separately for each neighboring RNC.
If the user plane is not supported between SRNC and DRN
procedure is not possible.
HOPS
Parameter indicates whether the neighbouring cell can par
is controlled by a RNC other than the local RNC.

ADJI
This parameter indicates whether the inter-frequency neigh
System Information Block 11&12&18 for the cell selection
The inter-frequency neighbour cell is included in the system
of the parameter is "yes".

ADJS
The parameter indicates whether the intra-frequency neigh
System Information Block 11&12&18 for the cell selection
The intra-frequency neighbour cell is included in the system
of the parameter is "yes".

5
6
7
8

UeMeasControl
reportingRange1a
6 (=3dB)
0.5dB
Used by UE functions for intra-frequency measurement reporting (in CELL_DCH).
Threshold used for addition-window in evaluation criteria for event type 1a.

FMCS
Addition Window determines the relative threshold (A_Win
the reporting range of event 1A. The threshold is either rel
measurement result of the best active set cell (M_best), or
measurement results (M_sum), depending on the value of
Weighting Coefficient (W). When the CPICH Ec/No measu
cell (M_new) enters the reporting range, the UE transmits
RNC in order to add the monitored cell into the active set:
W )* M_best - A_Win

UeMeasControl

FMCS

10

11

w1a

11

Weight factor to include active set cells other than the best in evaluation criteria for Active Set Weighting Coefficient (W) is used to weight eith
event 1a.
the best active set cell (M_best) or the sum of measureme
Used by UE functions for intra-frequency measurement reporting (in CELL_DCH). (M_sum) when the UE calculates the reporting range for th
1B (dropping of cell). The formula is: W * M_sum + ( 1 - W

UeMeasControl
hysteresis1a
0
dB
Hysteresis used in addition-window in evaluation criteria for event 1a to avoid ping
pong effects. Used by UE functions for intra-frequency measurement reporting in
CELL_DCH.

12

UeMeasControl
timeToTrigger1a
11 (=320ms) ms
Time in milliseconds (ms) between detection of event 1a and sending of the
measurement report.

FMCS
When a monitored cell enters the reporting range (addition
continuously stay within the reporting range for a given per
send a Measurement Report to the RNC in order to add th
1A). The length of this period is controlled by the paramete

UeMeasControl
reportingInterval1a
3 (=1s)
s
Interval of event-triggered periodical reporting in case of 'cell addition failure' or 'cell
replacement failure'. Indicates the interval in seconds (s) of periodical reporting
triggered by event 1a. Used by UE functions for intra-frequency measurement
reporting in CELL_DCH.

FMCS
When a monitored cell enters the reporting range and trigg
the UE transmits a Measurement Report to the RNC. If the
monitored cell to the active set, the UE continues reporting
reverting to periodical measurement reporting. The parame
determines the interval between periodical measurement r
triggered by the event 1A.

UeMeasControl
reportingRange1b
10 (=5dB)
dB
Used by UE functions for intra-frequency measurement reporting (in CELL_DCH).
Threshold used for dropwindow in evaluation criteria for event 1b.

FMCS
Drop Window determines the relative threshold (D_Win) w
calculate the reporting range of event 1B. The threshold is
Ec/No measurement result of the best active set cell (M_b
measurement results (M_sum), depending on the value of
Weighting Coefficient (W). When the CPICH Ec/No measu
cell (M_old) leaves the reporting range, the UE transmits a
RNC in order to remove the cell from the active set: M_old
M_best - D_Win

UeMeasControl
w1b
0
Weight factor to include active set cells other than the best in evaluation criteria for
event 1b. Used by UE functions for intra-frequency measurement reporting (in
CELL_DCH).

FMCS
Active Set Weighting Coefficient (W) is used to weight eith
the best active set cell (M_best) or the sum of measureme
(M_sum) when the UE calculates the reporting range for th
1B (dropping of cell). The formula is: W * M_sum + ( 1 - W

UeMeasControl
hysteresis1b
0
dB
Hysteresis used in the drop window in evaluation criteria for event type 1b. Used
by UE functions for intra-frequency measurement reporting in CELL_DCH.

13

14

15

16

17

18

19

UeMeasControl
timeToTrigger1b
12 (=640ms) ms
Time in milliseconds (ms) between detection of event 1b and sending of the
measurement report.

FMCS
When an active set cell leaves the reporting range (drop w
continuously stay outside the reporting range for a given p
can send a Measurement Report to the RNC in order to re
set (event 1B). The length of this period is controlled by the

UeMeasControl

FMCS

hysteresis1c

2 (=1dB)

dB

19

Used by UE functions for intra-frequency measurement reporting (in CELL_DCH). When the number of cells in the active set has reached the
Hysteresis used in replacement threshold in evaluation criteria for event 1c to avoid parameter MaxActiveSetSize and a monitored cell become
ping pong effects.
cell, the UE transmits a Measurement Report to the RNC i
cell with the monitored cell (event 1C). The parameter Rep
the margin by which the CPICH Ec/No measurement resul
must exceed the CPICH Ec/No measurement result of the
before the UE can send the event 1C triggered Measurem
>= MInAs + ReplacementWindow / 2

UeMeasControl
timeToTrigger1c
11 (=320ms) ms
Time in milliseconds (ms) between detection of event 1c and sending of the
measurement report.

FMCS
When the number of cells in the active set has reached the
cell enters the reporting range (replacement window), the m
continuously stay within the reporting range for a given per
send a Measurement Report to the RNC in order to replac
monitored cell (event 1C).

UeMeasControl
reportingInterval1c
3 (=1s)
s
Interval of event-triggered periodical reporting in case of 'cell addition failure' or 'cell
replacement failure'. Indicates the interval in seconds (s) of periodical reporting
triggered by event 1c.

FMCS
When the number of cells in the active set has reached the
cell becomes better than an active set cell, the UE transm
the RNC in order to replace the active cell with the monitor
is not able to replace the active cell with the monitored cel
after the initial report by reverting to periodical measureme
Replacement Reporting Interval determines the interval of
reports when such reporting is triggered by the event 1C

UeMeasControl
hysteresis1d
15 (=7.5dB) dB
Used by UE functions for intra-frequency measurement reporting (in CELL_DCH).
Hysteresis used in dropwindow in evaluation criteria for event type 1d.

RNC
Parameter determines the maximum allowed difference be
serving HS-DSCH cell. The window is relative to the best c
serving HS-DSCH cell change is outside of the window, se
procedure is initiated. The measured quantity is CPICH Ec
periodically from the UE.

23

UeMeasControl
hsHysteresis1d
10 (=1dB)
Sets the Event 1D hysteresis value specific for HS connections

24

UeMeasControl
timeToTrigger1d
14 (=2560ms)ms
Time in milliseconds (ms) between detection of event 1d and sending of the
measurement report.

25

UeMeasControl
hsTimeToTrigger1d
640
ms
Sets the Event 1D Time to Trigger value specific for HS connections

UeMeasControl
filterCoefficient2
2
Coefficient for layer 3 filtering before inter-frequency measurement reporting
evaluation.
dB
UeMeasControl
usedFreqRelThresh4_2bEcno
-1

20

21

22

26

27

dB

Relative threshold for event 2b vs event 2d, when the 2d measurement with
measurement quantity CPICH EC/NO was started.This parameter is used to
compute the absolute 2b Ec/No used frequency threshold, by adding it to the
current 2d Ec/No threshold (absolute 2b Ec/No used frequency threshold =
usedFreqThresh2dEcno + usedFreqRelThresh4_2bEcno). If the sum of the
calculation exceeds the maximum 3GPP value, the absolute 2b Ec/No threshold
value will be adjusted to the maximum value allowed by 3GPP before a
Measurement Control message is encoded and sent to the UE.
UeMeasControl

28

usedFreqRelThresh4_2bRscp

-3

dB

28

29

Relative threshold for event 2b vs event 2d when the 2d measurement with


measurement quantity CPICH RSCP was started.This parameter is used to
compute the absolute 2b Rscp threshold, by adding it to the current 2d Rscp
threshold (absolute 2b Rscp used frequency threshold = usedFreqThresh2dRscp +
usedFreqRelThresh4_2bRscp).If the sum of the calculation exceeds the maximum
3GPP value, the absolute 2b Rscp threshold value will be adjusted to the maximum
value allowed by 3GPP before a Measurement Control message is encoded and
sent to the UE.
UeMeasControl
usedFreqW4_2b
0
Weighting factor for measurement 4 event 2b for the currently used frequency.

30

UeMeasControl
hyst4_2b
Hysteresis for measurement 4 event 2b.

31

ms
UeMeasControl
timeTrigg4_2b
100
Time between detection of event 2b and sending of the measurement report, for
measurement 4.

32

dB
UeMeasControl
nonUsedFreqThresh4_2bEcno -13
Threshold for measurement 4 event 2b for the non-used frequencies when the
measurement quantity is Ec/No.

33

dBm
UeMeasControl
nonUsedFreqThresh4_2bRscp -105
Threshold for measurement 4 event 2b for the non-used frequencies when the
measurement quantity is RSCP.

34

UeMeasControl
nonUsedFreqW4_2b
0
Weighting factor for measurement 4 event 2b for the non-used frequencies.

35

dB
UtranCell
usedFreqThresh2dEcno
-12
Threshold for event 2d for the used frequency when the measurement quantity is
Ec/No.

36

dBm
UtranCell
usedFreqThresh2dRscp
-104
Threshold for event 2d for the used frequency when the measurement quantity is
RSCP.

37

dB
UeMeasControl
usedFreqThresh2dEcnoDrnc
-12
Threshold for event 2d for the used frequency for cells located in DRNC when the
measurement quantity is Ec/No.

38

dBm
UeMeasControl
usedFreqThresh2dRscpDrnc
-100
Threshold for event 2d for the used frequency for cells located in the DRNC when
the measurement quantity is RSCP.

39

ms
UeMeasControl
timeToTrigger2dEcno
320
Time in milliseconds (ms) between detection of event 2d and sending of the
measurement report, when the measurement quantity is CPICH EC/NO.

40

UeMeasControl
usedFreqW2d
0
Weighting factor for event 2d for the used frequency.

41

UeMeasControl
hysteresis2d
Hysteresis for event 2d.

dB

42

ms
UeMeasControl
timeToTrigger2dRscp
320
Time in milliseconds (ms) between detection of event 2d and sending of the
measurement report, when the measurement quantity is CPICH RSCP.
UeMeasControl

43

usedFreqRelThresh2fEcno

10 (=1dB)

dB

dB

43

Relative threshold for event 2f vs event 2d for the used frequency when the
measurement quantity is Ec/No.Note 1: The threshold for event 2d is configured
per cell in usedFreqThresh2dEcno. For DRNC cells, the global value
usedFreqThresh2dEcnoDrnc is used instead.Note 2: This parameter is used for
calculation of a threshold value for the used frequency for 2f events. The
calculated value is sent to the UE in a RRC Measurement Control message. If the
sum of the calculation (usedFreqRelThresh2fEcno + usedFreqThresh2dEcno), or
(usedFreqRelThresh2fEcno + usedFreqThresh2dEcnoDrnc) for DRNC cells,
exceeds the maximum 3GPP value 0dB, the value sent to the UE will be 0dB

44

UeMeasControl
usedFreqRelThresh2fRscp
3
dB
Relative threshold for event 2f vs event 2d for the used frequency when the
measurement quantity is RSCP.Note 1: the threshold for event 2d is configured per
cell in usedFreqThresh2dRscp. For DRNC cells, the global value
usedFreqThresh2dRscpDrnc is used instead.Note 2: This parameter is used for
calculation of a threshold value for the used frequency for 2f events. The
calculated value is sent to the UE in a RRC Measurement Control message. If the
sum of the calculation (usedFreqRelThresh2fRscp + usedFreqThresh2dRscp), or
(usedFreqRelThresh2fRscp + usedFreqThresh2dRscpDrnc) for DRNC cells,
exceeds the maximum 3GPP value -25dBm, the value sent to the UE will be 25dBm
-

45

UeMeasControl
usedFreqW2f
0
Weighting factor for event 2f for the used frequency.

46

UeMeasControl
hysteresis2f
Hysteresis for event 2f.

dB

47

ms
UeMeasControl
timeToTrigger2fEcno
1280
Time in milliseconds (ms) between detection of event 2f and sending of the
measurement report, when the measurement quantity is CPICH EC/NO.

48

ms
UeMeasControl
timeToTrigger2fRscp
1280
Time in milliseconds (ms) between detection of event 2f and sending of the
measurement report, when the measurement quantity is CPICH RSCP.
-

FMCI
This parameter indicates whether an inter-frequency hando
absolute CPICH Ec/No of the serving cell is enabled.
When the inter-frequency handover is enabled, the RNC s
CPICH Ec/No measurement in order to monitor the absolu
cell.
The measurement reporting criteria of the intra-frequency
are defined by the Intra-frequency Measurement Control p

FMCI
This parameter indicates whether an inter-frequency hando
absolute CPICH RSCP of the serving cell is enabled. Whe
is enabled, the RNC shall set up an intra-frequency CPICH
to monitor the absolute CPICH RSCP of the serving cell.T
criteria of the intra-frequency CPICH RSCP measurement
frequency Measurement Control parameters (FMCS objec

FMCS

49

50

51

If the inter-frequency or inter-RAT (GSM) handover caused


CPICH Ec/No is enabled, the RNC starts the inter-frequen
compressed mode when all active set cells have triggered
CPICH Ec/No. The RNC cancels the event 1F of an active
measurement result of the active set cell becomes better t
HHoEcNoCancel and the UE transmits the corresponding
Measurement Report to the RNC. The parameter HHoEcN
time period during which the CPICH Ec/No of the active se
threshold HHoEcNoCancel before the UE can trigger the r

51

FMCS
If the inter-frequency or inter-RAT (GSM) handover caused
CPICH Ec/No is enabled, the RNC starts the inter-frequen
compressed mode when all active set cells have triggered
CPICH Ec/No. The RNC cancels the event 1F of an active
measurement result of the active set cell becomes better t
HHoEcNoCancel and the UE transmits the corresponding
Measurement Report to the RNC.

FMCS
If the inter-frequency or inter-RAT (GSM) handover caused
CPICH Ec/No is enabled, the UE transmits an event 1F tri
the RNC when the CPICH Ec/No measurement result of a
worse than or equal to an absolute CPICH Ec/No threshold
HHoEcNoThreshold determines the absolute CPICH Ec/N
the UE to trigger the reporting event 1F. When the measur
set cells has become worse than or equal to the threshold
inter-frequency or inter-RAT (GSM) measurements in com
of hard handover

FMCS
If the inter-frequency or inter-RAT (GSM) handover caused
CPICH Ec/No is enabled, the UE transmits an event 1F tri
the RNC when the CPICH Ec/No measurement result of a
worse than the threshold HHoEcNoThreshold. The parame
determines the time period during which the CPICH Ec/No
stay worse than the threshold HHoEcNoThreshold before t
reporting event 1F.

FMCS
If the inter-frequency or inter-RAT (GSM) handover caused
CPICH RSCP is enabled, the RNC starts the inter-frequen
compressed mode when all active set cells have triggered
CPICH RSCP. The RNC cancels the event 1F of an active
measurement result of the active set cell becomes better t
HHoRscpCancel and the UE transmits the corresponding e
measurement report to the RNC.

FMCS
The parameter HHoRscpCancelTime determines the time
CPICH RSCP of the active set cell must stay better than th
before the UE can trigger the reporting event 1E.

FMCS

52

53

54

55

56
-

57

If the inter-frequency or inter-RAT (GSM) handover caused


RSCP is enabled, the UE transmits an event 1F triggered
RNC when the CPICH RSCP measurement result of an ac
than or equal to an absolute CPICH RSCP threshold. The
determines the absolute CPICH RSCP threshold which is
reporting event 1F.

57

FMCS
The parameter HHoRscpTimeHysteresis determines the ti
CPICH RSCP of the active set cell must stay worse than th
HHoRscpThreshold before the UE can trigger the reporting

ADJI
This parameter determines the minimum required CPICH
averaged measurement result of the best inter-frequency n
before the quality reason inter-frequency handover is poss

ADJI
This parameter indicates the maximum transmission powe
the DPCH in the neighbouring cell. The RNC uses the para
algorithm of the inter-frequency handover. If the maximum
lower than the value of the parameter, the RNC adds the p
the minimum required CPICH RSCP level, which the meas
neighbour cell must exceed before the handover is possibl

ADJI
This parameter determines the margin by which the averag
measurement result of the best inter-frequency neighbour
CPICH Ec/No measurement result of the best active set ce
inter-frequency handover is possible

ADJI
This parameter determines the minimum required CPICH
averaged measurement result of the best inter-frequency n
before the coverage reason inter-frequency handover is po

ADJI
This parameter determines the margin by which the averag
best active set cell must exceed the averaged propagation
frequency neighbour cell before the coverage reason interpossible.

58
59
-

60

61
62
63
64

65

UeMeasControl
utranFilterCoefficient3
2
Coefficient for layer 3 filtering of UTRAN quality before inter-RAT reporting
evaluation.

UeMeasControl
gsmFilterCoefficient3
1
Coefficient for layer 3 filtering of GSM quality before inter-RAT reporting evaluation.
-

66

67

UeMeasControl
utranRelThresh3aEcno
2
dB
Relative threshold for event 3a vs event 2d, when the 2d measurement with
measurement quantity CPICH EC/NO was started.This parameter is used to
compute the absolute 3a Ec/No threshold, by adding it to the current 2d Ec/No
threshold (absolute 3a Ec/No threshold = usedFreqThresh2dEcno +
utranRelThresh3aEcno).If the sum of the calculation exceeds the maximum 3GPP
value, the absolute 3a Ec/No threshold value will be adjusted to the maximum
value allowed by 3GPP before a Measurement Control message is encoded and
sent to the UE.
dB
UeMeasControl
utranRelThresh3aRscp
3
-

67

Relative threshold for event 3a vs event 2d when the 2d measurement with


measurement quantity CPICH RSCP was started.This parameter is used to
compute the absolute 3a Rscp threshold, by adding it to the current 2d Rscp
threshold (absolute 3a RSCP threshold = usedFreqThresh2dRscp +
utranRelThresh3aRscp).If the sum of the calculation exceeds the maximum 3GPP
value, the absolute 3a RSCP threshold value will be adjusted to the maximum
value allowed by 3GPP before a Measurement Control message is encoded and
sent to the UE.
-

68

UeMeasControl
utranW3a
Weighting factor for event 3a for UTRAN.

69

UeMeasControl
timeToTrigger3a
6 (=100ms) ms
Time in milliseconds (ms) between detection of event 3a and sending of the
measurement report.
-

70
71

72

FMCG
GSM HO caused by CPICH Ec/No

FMCG
GSM HO caused by CPICH RSCP

ExternalGsmCell individualOffset
0
dB
Used in UE function event-reporting.This offset is added to the measured quantity
before the UE evaluates if an event has occured.

ADJG
The parameter indicates whether the GSM neighbour cell
Information Block 11&12&18 for the cell selection and re-s
neighbour cell is included in the system information when
"yes".

73
-

75

76

77

78

GsmRelation
qOffset1sn
7
dB
Signal stength offset between source and target cells. Used when the IE
"cell_selection_and_reselection_quality_measure" in SIB 11/12 is set to "CPICH
RSCP". This is configured through UtranCell::qualMeasQuantity.

HOPG
This parameter is used in the cell re-selection and ranking
cells. The value of this parameter is subtracted from the m
the neighbouring cell before the UE compares the quality m
selection/ranking criteria

dBm
UeMeasControl
gsmThresh3a
-95
Threshold for event 3a for GSM. Range is valid for GSM carrier RSSI.

HOPG
This parameter determines the minimum required GSM RS
RSSI value of the GSM neighbour cell must exceed before
reason handover to GSM is possible

UeMeasControl
hysteresis3a
Hysteresis for event 3a.

dB

HOPG
This parameter determines the minimum required GSM RS
RSSI value of the GSM neighbour cell must exceed before
reason handover to GSM is possible

ExternalGsmCell bandIndicator
0 = DCS1800 Indicates the frequency band of the external GSM cell.

ADJG
This parameter indicates how to interpret the value of the p

ADJG
This parameter indicates the maximum transmission powe
a TCH in the GSM neighbour cell. The RNC uses the para
of the inter-RAT (GSM) handover. If the maximum output p
the value of the parameter, the RNC adds the power differ
minimum required GSM RSSI level, which the measureme
neighbour cell must exceed before the handover is possibl

79

Nokia
Parameter

Default

Unit

MaxActiveSetSize
3
This parameter determines the maximum number of cells which can participate in a
soft/softer handover.

AdjsEcNoOffset
0
dB
The CPICH Ec/No Offset determines an offset value, which the UE adds to the CPICH
Ec/No measurement result of the neighbouring cell before it compares the Ec/No value
with the reporting criteria
Supported (1)
IurUPSupport
This parameter indicates a user plane procedure support of the Iur connection. This
information is given separately for each neighboring RNC.
If the user plane is not supported between SRNC and DRNC, initiation of a soft handover
procedure is not possible.
EnableInterRNCsho
Yes(1)
Parameter indicates whether the neighbouring cell can participate in a soft handover, if it
is controlled by a RNC other than the local RNC.
AdjiSIB
Yes (1)
This parameter indicates whether the inter-frequency neighbour cell is included in the
System Information Block 11&12&18 for the cell selection and re-selection procedures.
The inter-frequency neighbour cell is included in the system information when the value
of the parameter is "yes".
AdjiSIB
Yes (1)
The parameter indicates whether the intra-frequency neighbour cell is included in the
System Information Block 11&12&18 for the cell selection and re-selection procedures.
The intra-frequency neighbour cell is included in the system information when the value
of the parameter is "yes".
AdditionWindow
3
dB
Addition Window determines the relative threshold (A_Win) used by the UE to calculate
the reporting range of event 1A. The threshold is either relative to the CPICH Ec/No
measurement result of the best active set cell (M_best), or to the sum of active set
measurement results (M_sum), depending on the value of the parameter Active Set
Weighting Coefficient (W). When the CPICH Ec/No measurement result of a monitored
cell (M_new) enters the reporting range, the UE transmits a Measurement Report to the
RNC in order to add the monitored cell into the active set: M_new >= W * M_sum + ( 1 W )* M_best - A_Win

ActiveSetWeightingCoefficient

Active Set Weighting Coefficient (W) is used to weight either the measurement result of
the best active set cell (M_best) or the sum of measurement results of all active set cells
(M_sum) when the UE calculates the reporting range for the events 1A (cell addition) and
1B (dropping of cell). The formula is: W * M_sum + ( 1 - W )* M_best

AdditionTime
320
ms
When a monitored cell enters the reporting range (addition window), the cell must
continuously stay within the reporting range for a given period of time before the UE can
send a Measurement Report to the RNC in order to add the cell into the active set (event
1A). The length of this period is controlled by the parameter Addition Time

AdditionReportingInterval
1
s
When a monitored cell enters the reporting range and triggers event 1A (cell addition),
the UE transmits a Measurement Report to the RNC. If the RNC is not able to add the
monitored cell to the active set, the UE continues reporting after the initial report by
reverting to periodical measurement reporting. The parameter Addition Reporting Interval
determines the interval between periodical measurement reports when such reporting is
triggered by the event 1A.

DropWindow
6
dB
Drop Window determines the relative threshold (D_Win) which is used by the UE to
calculate the reporting range of event 1B. The threshold is either relative to the CPICH
Ec/No measurement result of the best active set cell (M_best) or to the sum of active set
measurement results (M_sum), depending on the value of the parameter Active Set
Weighting Coefficient (W). When the CPICH Ec/No measurement result of an active set
cell (M_old) leaves the reporting range, the UE transmits a Measurement Report to the
RNC in order to remove the cell from the active set: M_old <= W * M_sum + ( 1 - W )*
M_best - D_Win

ActiveSetWeightingCoefficient
0
Active Set Weighting Coefficient (W) is used to weight either the measurement result of
the best active set cell (M_best) or the sum of measurement results of all active set cells
(M_sum) when the UE calculates the reporting range for the events 1A (cell addition) and
1B (dropping of cell). The formula is: W * M_sum + ( 1 - W )* M_best
-

DropTime
640
ms
When an active set cell leaves the reporting range (drop window), the cell must
continuously stay outside the reporting range for a given period of time before the UE
can send a Measurement Report to the RNC in order to remove the cell from the active
set (event 1B). The length of this period is controlled by the parameter Drop Time

ReplacementWindow

dB

When the number of cells in the active set has reached the maximum specified by the
parameter MaxActiveSetSize and a monitored cell becomes better than an active set
cell, the UE transmits a Measurement Report to the RNC in order to replace the active
cell with the monitored cell (event 1C). The parameter Replacement Window determines
the margin by which the CPICH Ec/No measurement result of the monitored cell (MNew)
must exceed the CPICH Ec/No measurement result of the an active set cell (MInAS)
before the UE can send the event 1C triggered Measurement Report to the RNC: MNew
>= MInAs + ReplacementWindow / 2

ReplacementTime
200
ms
When the number of cells in the active set has reached the maximum, and a monitored
cell enters the reporting range (replacement window), the monitored cell must
continuously stay within the reporting range for a given period of time before the UE can
send a Measurement Report to the RNC in order to replace an active set cell with the
monitored cell (event 1C).

ReplacementReportingInterval
1
s
When the number of cells in the active set has reached the maximum, and a monitored
cell becomes better than an active set cell, the UE transmits a Measurement Report to
the RNC in order to replace the active cell with the monitored cell (event 1C). If the RNC
is not able to replace the active cell with the monitored cell, the UE continues reporting
after the initial report by reverting to periodical measurement reporting. The parameter
Replacement Reporting Interval determines the interval of periodical measurement
reports when such reporting is triggered by the event 1C

HSDPAServCellWindow
4
dB
Parameter determines the maximum allowed difference between the best cell and the
serving HS-DSCH cell. The window is relative to the best cell in the active set. If the
serving HS-DSCH cell change is outside of the window, serving HS-DSCH cell change
procedure is initiated. The measured quantity is CPICH Ec/No, which is received
periodically from the UE.

IFHOcauseCPICHEcNo
Enabled(1)
This parameter indicates whether an inter-frequency handover caused by low measured
absolute CPICH Ec/No of the serving cell is enabled.
When the inter-frequency handover is enabled, the RNC shall set up an intra-frequency
CPICH Ec/No measurement in order to monitor the absolute CPICH Ec/No of the serving
cell.
The measurement reporting criteria of the intra-frequency CPICH Ec/No measurement
are defined by the Intra-frequency Measurement Control parameters (FMCS object)

1st carrier:Disable(0)
IFHOcauseCPICHrscp
2nd carrier:Enabled(1)
This parameter indicates whether an inter-frequency handover caused by low measured
absolute CPICH RSCP of the serving cell is enabled. When the inter-frequency handover
is enabled, the RNC shall set up an intra-frequency CPICH RSCP measurement in order
to monitor the absolute CPICH RSCP of the serving cell.The measurement reporting
criteria of the intra-frequency CPICH RSCP measurement are defined by the Intrafrequency Measurement Control parameters (FMCS object)
HHoEcNoCancelTime

640

ms

If the inter-frequency or inter-RAT (GSM) handover caused by low measured absolute


CPICH Ec/No is enabled, the RNC starts the inter-frequency or GSM measurement in
compressed mode when all active set cells have triggered the reporting event 1F for
CPICH Ec/No. The RNC cancels the event 1F of an active set cell if the CPICH Ec/No
measurement result of the active set cell becomes better than or equal to the threshold
HHoEcNoCancel and the UE transmits the corresponding event 1E triggered
Measurement Report to the RNC. The parameter HHoEcNoCancelTime determines the
time period during which the CPICH Ec/No of the active set cell must stay better than the
threshold HHoEcNoCancel before the UE can trigger the reporting event 1E.

HHoEcNoCancel
dB
-9
If the inter-frequency or inter-RAT (GSM) handover caused by low measured absolute
CPICH Ec/No is enabled, the RNC starts the inter-frequency or GSM measurement in
compressed mode when all active set cells have triggered the reporting event 1F for
CPICH Ec/No. The RNC cancels the event 1F of an active set cell if the CPICH Ec/No
measurement result of the active set cell becomes better than or equal to the threshold
HHoEcNoCancel and the UE transmits the corresponding event 1E triggered
Measurement Report to the RNC.

HHoEcNoThreshold
dB
-12
If the inter-frequency or inter-RAT (GSM) handover caused by low measured absolute
CPICH Ec/No is enabled, the UE transmits an event 1F triggered measurement report to
the RNC when the CPICH Ec/No measurement result of an active set cell becomes
worse than or equal to an absolute CPICH Ec/No threshold. The parameter
HHoEcNoThreshold determines the absolute CPICH Ec/No threshold which is used by
the UE to trigger the reporting event 1F. When the measured CPICH Ec/No of all active
set cells has become worse than or equal to the threshold in question, the RNC starts
inter-frequency or inter-RAT (GSM) measurements in compressed mode for the purpose
of hard handover

HHoEcNoTimeHysteresis
ms
200
If the inter-frequency or inter-RAT (GSM) handover caused by low measured absolute
CPICH Ec/No is enabled, the UE transmits an event 1F triggered measurement report to
the RNC when the CPICH Ec/No measurement result of an active set cell becomes
worse than the threshold HHoEcNoThreshold. The parameter HHoEcNoTimeHysteresis
determines the time period during which the CPICH Ec/No of the active set cell must
stay worse than the threshold HHoEcNoThreshold before the UE can trigger the
reporting event 1F.

1st carrier: -96


HHoRscpCancel
2nd carrier: -93
dBm
If the inter-frequency or inter-RAT (GSM) handover caused by low measured absolute
CPICH RSCP is enabled, the RNC starts the inter-frequency or GSM measurement in
compressed mode when all active set cells have triggered the reporting event 1F for
CPICH RSCP. The RNC cancels the event 1F of an active set cell, if the CPICH RSCP
measurement result of the active set cell becomes better than or equal to the threshold
HHoRscpCancel and the UE transmits the corresponding event 1E triggered
measurement report to the RNC.

HHoRscpCancelTime
640
ms
The parameter HHoRscpCancelTime determines the time period during which the
CPICH RSCP of the active set cell must stay better than the threshold HHoRscpCancel
before the UE can trigger the reporting event 1E.
HHoRscpThreshold

1st carrier: -101


2nd carrier: -98

dBm

If the inter-frequency or inter-RAT (GSM) handover caused by a low measured CPICH


RSCP is enabled, the UE transmits an event 1F triggered measurement report to the
RNC when the CPICH RSCP measurement result of an active set cell becomes worse
than or equal to an absolute CPICH RSCP threshold. The parameter HHoRscpThreshold
determines the absolute CPICH RSCP threshold which is used by the UE to trigger the
reporting event 1F.
HHoRscpTimeHysteresis
ms
200
The parameter HHoRscpTimeHysteresis determines the time period during which the
CPICH RSCP of the active set cell must stay worse than the threshold
HHoRscpThreshold before the UE can trigger the reporting event 1F.
AdjiMinRSCP
dBm
-96
This parameter determines the minimum required CPICH RSCP level which the
averaged measurement result of the best inter-frequency neighbour cell must exceed
before the quality reason inter-frequency handover is possible
AdjiTxPwrDPCH
dBm
24
This parameter indicates the maximum transmission power level that a UE may use on
the DPCH in the neighbouring cell. The RNC uses the parameter in the decision
algorithm of the inter-frequency handover. If the maximum output power of the UE is
lower than the value of the parameter, the RNC adds the power difference (dB value) to
the minimum required CPICH RSCP level, which the measurement result of the
neighbour cell must exceed before the handover is possible

AdjiEcNoMargin
2
dB
This parameter determines the margin by which the averaged CPICH Ec/No
measurement result of the best inter-frequency neighbour cell must exceed the averaged
CPICH Ec/No measurement result of the best active set cell before the quality reason
inter-frequency handover is possible
AdjiMinEcNo
dB
-10
This parameter determines the minimum required CPICH Ec/No level which the
averaged measurement result of the best inter-frequency neighbour cell must exceed
before the coverage reason inter-frequency handover is possible.
AdjiPlossMargin
dB
2
This parameter determines the margin by which the averaged propagation loss of the
best active set cell must exceed the averaged propagation loss of the best interfrequency neighbour cell before the coverage reason inter-frequency handover is
possible.
-

GSMcauseCPICHEcNo
GSM HO caused by CPICH Ec/No

Disable(0)

GSMcauseCPICHrscp
GSM HO caused by CPICH RSCP

Enabled(1)

AdjiSIB
Yes (1)
The parameter indicates whether the GSM neighbour cell is included in the System
Information Block 11&12&18 for the cell selection and re-selection procedures. The GSM
neighbour cell is included in the system information when the value of the parameter is
"yes".
AdjgQoffset1
0
dB
This parameter is used in the cell re-selection and ranking between WCDMA and GSM
cells. The value of this parameter is subtracted from the measured GSM carrier RSSI of
the neighbouring cell before the UE compares the quality measure with the cell reselection/ranking criteria
dBm
AdjgRxLevMinHO
-100
This parameter determines the minimum required GSM RSSI level which the averaged
RSSI value of the GSM neighbour cell must exceed before the coverage (or quality)
reason handover to GSM is possible
dBm
AdjgRxLevMinHO
-100
This parameter determines the minimum required GSM RSSI level which the averaged
RSSI value of the GSM neighbour cell must exceed before the coverage (or quality)
reason handover to GSM is possible
AdjgBandIndicator
This parameter indicates how to interpret the value of the parameter AdjgBCCH.
AdjgTxPwrMaxTCH
33
dBm
This parameter indicates the maximum transmission power level that an UE may use on
a TCH in the GSM neighbour cell. The RNC uses the parameter in the decision algorithm
of the inter-RAT (GSM) handover. If the maximum output power of the UE is lower than
the value of the parameter, the RNC adds the power difference (dB value) to the
minimum required GSM RSSI level, which the measurement result of the GSM
neighbour cell must exceed before the handover is possible

S-ar putea să vă placă și