Introduction
We are aiming for unsurpassed technology
in the area of safety and energy solutions
Samsung Techwin has leveraged outstanding technological competencies to emerge as a global leader
in energy and safety solutions.
We believe that creating new paradigms that are a step ahead of changing times is the only way to
sustain growth and elevate customer value in today's fast-paced business environment.
Samsung Techwin has played a pivotal role in the development of the precision machinery industry. we
are proactively addressing the dynamic marketplace, taking advantage of core competencies acquired
to date to restructure our business model for greater profitability.
Samsung Techwin is already a leader in security imaging, and now we are ready to make strides as a
top-tier maker of precision control devices and systems. Our product lines will span next-generation
"intelligent" robots for industrial, surveillance and medical applications as well as compressors and
generators for ships, offshore structures and renewable energy production.
Our commitment to excellence does not stop with technology development to ensure top quality. We
continue to transform and work hard in order to earn the trust of our customers. To this end our
corporate culture puts a priority on cultivating top-notch personnel, maintaining an open management
policy and sharing benefits.
We have taken on the creative challenge of applying cutting-edge technology to make life safer and
more convenient. Our ultimate goal is your well-being and happiness, and we invite you to watch how
we shape a better future for all.

Contents
Samsung
Smart Building
Smart Building Solution Management Software

Smart
Products

- Solution Overview & Features


- System Architecture

- Controllers
- Sensors

04

- Software application
- Smart Building Management
S/W Functions
08

10

BAS Products

12

Make the

Building
Smarter & Greener

with Samsung Techwin

Samsung Smart Building Solution 3

Samsung

Smart Building Solution


Samsung Smart Building Solution is an intelligent automated
system designed for buildings, which creates a comfortable
environment; utilizing integrated facility control, efficient
building operation and improved energy efficiency.

Smart User Experience


Convenient building operation with friendly UX(User eXperience)
Compatible with standard web browsers
Access anytime, anywhere via a web-based remote building
management system

Open structure for seamless


customized integration
Advanced scalability with standard OS(Windows
2008 server, Windows XP, Windows 7)
Support for standard protocols such as BACnet,
LonWorks, Modbus and oBIX(Open Building
Information eXchange)
Seamless integration regardless of manufacturer

Vivid video surveillance with CCTV integration


Real-time remote monitoring available with CCTV
Support 4-channel live view to enhance your central
management control
Auto video pop-up in case of events

Rapid response to events via


remote control
Auto E-mail alert in case of events
Support for surveillance cameras to control remotely
Integration with mobile devices enables real-time video
verification and energy analysis data monitoring

4 Samsung Smart Building Solution

Solution Overview & Features

Web-based remote building management system


Support for standard protocols such as BACnet, LonWorks,
Modbus and oBIX(Open Building Information eXchange)
Enhanced convenience with friendly UX(User eXperience)
Efficient building operation through energy saving
Seamless integration regardless of manufacturer
Remote video monitoring and auto video pop-up in
case of events
Auto e-mail alert in case of events
Scalable communication with standard protocols among
networks, controllers and sensors

Samsung Smart Building Solution 5

System architecture
Samsung Smart

Video
Matrix

BEMS Server

CCTV Monitor

Total Management Server

Ethernet TCP/IP,

HVAC

Lighting

Gateway

BACnet

Modbus

Gateway

LonWorks

Gateway

Power

Meters

BACnet,

Lighting Cont,

Lighting Cont,

LonWorks,

Building Energy
Management

Gateway
LonWorks

HVAC

Control

Gateway
Modbus

Access Control Server

TSM server

RGB

Power Meters

GAS Meters

Meters

Sensors
VAV

Sensor

VAV

Sensor

Lighting Cont,
Flow Meters

Sensors
Terminal Unit

Terminal Unit

Terminal Unit

Terminal Unit

Thermostats

Thermostats

Meters
Program Switch

Sensors

HVAC Control System


6 Samsung Smart Building Solution

Power / Lighting
Control System

Sensors

Building Energy
Management System

Building Solution
HVAC

Hot and Cold Water Control

Hot-water Supply Control Power Management

Matrix

Video/R
GB
Matrix

Boiler Control

Sunblind Control

Lighting Control

Security & Video


Surveillance

Web Based Monitoring Service


BUILDING NETWORK
PROTOCOL

ODBC

Firewall

Firewall
Modem

Internet
Browser

Modem

Web
Station

Internet

Mobile
Device

XML,

HTTP,

oBIX,

Sunblind

FOX
Access Control

IP CCTV

Gateway

NVR
ACU

TCP/IP

LonWorks

Speed Dome

NVR

Motor Controller
Fingerprint & RF

Fixed Dome

Box Cam
RF
Receiver

Monitor

Fingerprint Reader

RS-232/422/485

Modbus,

TCP/IP

Station

Fingerprint & RF

RF & Keypad

Zoom Cam
Network
Controller
Remote
Controller

Fingerprint Reader

Fingerprint Reader

Speed Dome
RF/LF Reader

Roll Screen
Video Server

Fixed Box
RF/LF Card

Roll Screen System

Security System
Samsung Smart Building Solution 7

Smart Building Management Software


Software Application

HVAC management

HVAC facility monitoring and control for pleasant


indoor environment

Power Monitoring

Status control of power supply, voltage in the electric


room and switches

Lighting Control

Monitoring and control of lighting appliances status


per floor

8 Samsung Smart Building Solution

Smart Building Management Software Function


Smart HMI

Graphic User Interface


A powerful graphic editor to create graphics for a variety of
animations and 3D symbols makes your surveillance and control
vivid on the screen.

Video surveillance screen


In sync with the IP cameras installed in the facility room, display
the event video in case of events and record the video with NVR
within a specific time limit.

Point monitoring and control


Collect data at a certain interval and in case of events, monitor
data by floor and by facilities and search by settpoint name

History
History data can be saved in various formats such as chart and
report form. Real-time and time-phased history management let
you check archive charts anytime. You can break down the charts
into a group for comparing data at a glance.

System monitoring
System Monitoring recognizes and displays the operation status
of each controller on the network. You can check every single I/O
operation status of connected controllers in detail.

Alarm
List of recent 5 alarms is always fixed at the bottom of the screen.
It can also be hidden. In case of events, alarm video pop-up is
generated for users immediate response. Past alarm videos
can be output in the time frame upon request through history
management.

Schedule
You can make a daily, holiday or weekday schedule and edit your
schedule with the simple click.

Samsung Smart Building Solution 9

Smart Products
BACnet controllers for optimum building operation
SMART Controllers for your building
Adopt

BACnet protocol, the international standard protocol


and two types of extension modules for enhanced flexibility
Built-in energy-efficient control logic for optimal management system
Default

SAG-B0640/B1280

Network gateway controller (64M/128M)


Control, monitoring, data logging, alarm, scheduling and network
management and web service integrated
Remotely send data to the standard Web browser
System integration software NiagaraAX technology adopted

SAC-B1612

BACnet Programmable Controller (28-point)


Programmable controller for customized control of HVAC facilities including
conditioner, refrigerator, boiler etc.

SAC-C1200I/C1212I
I/O Extension Module for SAC-B1612
I/O Extension Module for SAC-B1612

SAC-B0608

BACnet Programmable Controller (14-point)


Programmable controller for Rooftop Units, Fan coil Units, Chilled ceilings,
Heat pumps, Unit ventilators and air conditioning units

SAC-B0507V

BACnet VAV(Variable Air Volume) Controller


Controller for VAV Box control with its built-in actuator
Embedded air flow sensor, damper actuator and VAV application program

10 BAS Integrated building automation systems

Smart indoor sensor only for room


SMART Sensors for your building

SAF-S0100/S0400

LCD Communicating Sensor (Temperature / Humidity)


Control rooms temperature, humidity level
System status indicator
Energy efficiency indicating with leaf icon for occupant's greener habit

SAF-S0500

Adjustable Thermostat Sensor


View the space temperature
Adjust the setpoint
Apply occupancy overrides
Built-in LAN port

Sunblind Controller

SMART Sunblind controllers for your building

SAC-L0404S/L0408S
Sunblind Controller

Integration with building system via standard protocol Lontalk


Sunblind control according to sunlight and room occupancy optimizes
energy savings made as a result of HVAC parameters

Samsung Smart Building Solution 11

Samsung

Smart Building
Solution

BAS Products
Software
Mobile Application
Network Control Unit
HVAC Controller
Sensor
Sunblind Controller

SAS-B1000/B2000
Web-oriented multi-protocol building automation management software

Technical Specifications
SAS-B1000

SAS-B2000

Device
Supported device

Gateway

Max. Register device

Unlimited

Interconnection with
Energy management S/W

O ( option )

Type
Period
Record count
History
Chart builder
Types of
graph
Type
Schedule
Order
Function
Supported
format
Video
Supported
Resolution
Driver
Graphic
Object
Monitoring Registration
Point
Group
Registration
Main pop-up
Authority
User
User
management
Expiration
Type

Graph, Table
Min 1 sec.
Depends on SAG-Bxxx series
Comparison of two more histories by graph

Function

Key Features
SAS-B1000

for small enterprise system

SAS-B2000

for large enterprise system

- Stable system operation : web-based remote building management system based on


Niagara platform
- Total management with just one S/W : HVAC, power, lighting, sunblind, CCTV
- Easy-to-use: Manage everything within 3 clicks
- Maximum user convenience: bookmark, point search
- Compatibility: Open protocols supported (BACnet, oBIX, Modbus, Onvif)
- Scalability : Configurable from small system to large system
- Optimum customization : Intuitive UI and management
- Multi-site monitoring and control
- Seamless 3rd party system integration with various drivers
- Alarm monitoring: video, message pop-up in case of alarms
- Video surveillance: Compatible with standard protocol (Onvif)
Real-time remote monitoring available with CCTV
- System monitoring: Monitoring I/O operation status of controllers
- Schedule: set operation schedule(daily, holiday, weekday)
- Point control: search or bookmark certain facility for easier management

Filtering
Alarm

General

Memo
Priority
E-mail
Video
verification

OS
System requirements
(Recommended)

Main Functions

System requirements
(Minimum)

Line, Area, Bar, Stacked bar, Discrete Line, Discrete Area, Pie
Day/Week/Holiday/D-day
Boolean, Numeric, Enumerate, String, Calender
LiveView(up to 4 channel), PTZ/Preset Control, Video pop-up in case of events
MPEG-4
640 X 480
Onvif 1.2 supported
Max 500 per screen
100
8 per group
500
Available
Admin, Operator
50
Configurable per ID
Off, normal, Fault
Source state, Ack state, point, Alarm class, Priority, Normal time, Ack
time, User, Alarm data, Last update
Saving the generated alarm notes
Setting the alarm class priority (Low, Normal, Emergency, High)
Sending by class
Video verification of camera linked to the point
Windows XP professional, windows 7 32 bit, windows server 2008(IIS disabled)
CPU: Dual Core 2.0GHz, RAM: 2GB
HDD: 500GB, Resolution: 1280x960
Web browser: Internet Explorer 7.0, 8.0, Network: 1GB with RJ-45 connector
CPU: Intel Pentium IV, RAM: 1GB
HDD: 100GB, Resolution: 1280x960
Web browser: Internet Explorer 7.0, 8.0, Network: 10/100MB with RJ-45 connector
* Specifications are subject to change without notice.

Option S/W
Video surveillance
In sync with the IP cameras installed
in the facility room, display the event
video upon triggering an alarm and
record the video with NVR within a
specific time limit.

History
History data can be saved in various
formats such as chart and report
form. Real-time and time-phased
history management let you check
archive charts anytime. You can
break down the charts into a group
for comparing data at a glance.

Point monitoring and control

Alarm Monitoring

Collect data at a certain interval and In case of alarm occurring, video pops
in case of events, monitor data by up automatically. You can extract realfloor and by facilities and search by time or time-phased archives.
settpoint name

System monitoring

Schedule

System Monitoring recognizes You can make a daily, holiday or


and displays the operation status weekday schedule and edit your
of each controller on the network. schedule with the simple click.
Yo u c a n c h e c k e v e r y s i n g l e
I/O operation status of connected
controllers in detail.

SAS-E1000

Station for Energy Management

SAS-E2000

Point for Energy Management

SAS-D1000

BACnet IP driver 500 points

SAS-D1100

Additional BACnet 500 points

SAS-D3000

Modbus TCP driver 500 points

SAS-D3100

Additional Modbus TCP 500 points

SAS-D4000

oBIX driver 500 points

SAS-D4100

Additional oBIX 500 points

SAS-D5000

MsSQL driver

SAS-D6000

ONVIF driver

13

Mobile Application
Mobile multi-site building automation management software

Technical Specifications
Function

History

Type

Graph, Table

Period

Min 1 sec.

Record count

Depends on SAG-Bxxx series

Chart builder

Comparison of two more histories by graph

Types of graph Line, bar


Schedule

Video

Key Features
- Remote building total management and system monitoring via mobile devices
- Multiple building management with a single device
- Convenient building operation with intuitive UI
- Enhanced esthetic with elaborated graphical control
- Real-time energy consumption monitoring: building management cost reduction
- Auto alarm pop-up for immediate response
- Integrated system control: HVAC, power, light, sunblind and energy management
- Bookmark: quick link to frequently managed floors, equipments and important alarms
- In case of alarms, real-time video verification enables rapid responses.
- Compatibility: open protocols supported(oBIX)

Graphic
Monitoring
User
management

Alarm

Type

Day/Week/Holiday/D-day

Order

Boolean, Numeric, Calendar

Function

Video pop-up in case of events, 1CH live view

Supported
format

H.264, MJPEG

Supported
resolution

640 X 480

Object

Max 500 per screen

Registration

100

Authority

Admin, Operator

User

50

Expiration

Configurable per ID

Type

Offnormal, Fault

Alarm verification

Alarm history verification(Ack)

Video verification Video verification of camera linked to the point

General
OS

Android Honeycomb

Supported device

Galaxy Tab 10.1


* Specifications are subject to change without notice.

Key Functions

Equipment control

Schedule monitoring

Alarm list

Energy management

Video verification

Point control and monitoring of each


equipment. Control categorized per floor
and equipments and administrators.

Daily, holiday, regular day schedule.


Controlled points output: Boonlean,
Numeric

Occurred alarm monitoring per sites point


Alarm list per point, alarm description
monitoring

Energy management through comparison


between current energy consumption
and target energy consumption

Real-time video monitoring via IP camera


installed in machine room. Auto video
pop-up in case of alarm

System status
Connection status of each devices

14

Configuration

History

Point search, control

User configuration(user ID, p/w),


application settings etc.

History graph created per each control


point. Multiple graphs comparison at
once

Control point search and management.


Categorization possible

SAG-B0640 / B1280
Network Control Unit (64M/128M)

Technical Specifications
SAG-B0640

SAG-B1280

Operational
IBM PowerPC 405 EP 250MHz
64MB DDR RAM
64MB Serial Flash

Processor
Memory

IBM Power PC 440 524MHz


128MB DDR RAM
128MB Serial Flash

Network
2 Ethernet Ports - 10/100Mbps (RJ-45 connectors)
1 RS-232 Port (9-pin D-shell connector)
1 RS-485 non-isolated port (3 screw connector on base board)
1 One 20-Pin Euro-DIN Connector (for I/O and Power modules)
2 communication card option slots
X
1

Methods

USB port

Operating Systems
QNX RTOS, IBM J9 JVM Java Virtual Machine, NiagaraAX

Type

Key Features

Mechanical

Control and management of external devices over the Internet

Material

 ontrol, monitoring, data logging, alarm, scheduling and network management


C
and web service integrated

Cooling
Dimensions (WxHxD)
Weight

Remotely send data to the standard Web browser

Information integration from multi gateways via software

Chassis: plastic
Cover: plastic
Internal air convention
160 X 122 X 62 mm (6.3''x 4.8''x 2.4'') (including connectors)
0.708Kg (1 lb 9 oz)

Environmental

 nhanced flexibility by adopting system integration software Niagara AX


E
technology

OperatingTemperature
Storage Temperature
Humidity

0C to 50C (32F ~122F)


0C to 60C (32F ~140F)
5% ~ 95% RH

Stand-alone control, power management and integrated application

* Specifications are subject to change without notice.

 BIX client/server and Niagara Network (Fox) Niagara client/server drivers


O
included

Recommended Peripherals
Other Products (H/W)

Dimensions

SAG-M0200

SAG-P1000

Dual port RS-485 option card

24V AC/DC, 50/60Hz Power


Supply Module. DIN rail
mountable

Unit: mm (inch)

Other Products (S/W)

122(4.8'')

160(6.3'')

SAG-D0200

Driver for MS/TP BACnet communications over RS-232 or RS-485 port

SAG-D0300

BACnet IP client license

SAG-D0400

Modbus driver license over serial

SAG-D0500

Modbus driver license over Ethernet

SAG-D0600

Extended memory part for 64Mb to 128Mb (SAG-B0640)

SAG-D0700

Extended memory part for 128Mb to 256Mb (SAG-B1280)

SAG-D0800

Web user interface engine license

SAG-D1000

Web programming tool license (SAG-D0800 required)

62(2.4'')

15

SAC-B1612
BACnet Programmable Controller (28-point)
- 16 UI, 12 UO
Technical Specifications
SAC-B1612
Points

28-point controller

Universal inputs

16

SAF-S0100 inputs

12

Universal outputs

12

Max. extension module

Electrical
Voltage

24VAC, 15%, 50/60Hz, Class 2

Protection

3.0A user-replaceable fuse

Power Consumption

22 VA Typical + all output loads, max 65VA

Communication

Key Features

Baud Rate

9,600/19,200/ 38,400/ 76,800 bps

Addressing

DIP switch(0-127)

Hardware

 rogrammable controller for customized control of HVAC facilities including


P
conditioner, refrigerator, boiler etc.
16 UI, 12 UO(software configurable)
 nhanced scalability with I/O extension module(up to 2) supporting up to 40
E
inputs and 36 outputs

Processor

STM32(ARM Cortex M3) MCU, 32 bit

CPU speed

72 MHz

Memory

1 MB Non-volatile Flash (applications), 2 MB Non-volatile Flash (storage), 96 kB RAM

Status Indicator

Green LEDs : Power Status & LAN Tx


Orange LEDs : Controller Status & LAN Rx

Environmental

GUI-based HVAC control sequence programming tool provided

Operating Temperature

0C to 50C ; 32F to 122F

Support NiagaraAX-based S-Controller Pro

Storage Temperature

-20C to 50C ; -4F to 122F

 uilt-in resistors and jumpers to control I/O eliminating the need for external
B
resistor

Humidity

0 ~ 90% RH

 ugged hardware Inputs and Outputs minimizing the need for external
R
protection components

Material

ABS

Color

Casing: Black / Connectors: Gray

Dimensions (W x H x D)

195.6mm x 119.4mm x 50.8mm (7.7 x 4.7 x 2.0)

Weight

0.53kg (1.17lbs)

Installation

Direct din-rail mounting

Mechanical

Inputs
Universal, Software Configurable
Voltage

- 0 to 10V DC (40k input impedance)


- 0 to 5V DC (high input impedance)

Current

0 to 20mA with 249 jumper configurable internal resistor

Digital

Dry Contact

Input
Pulse
types

Dimensions

Unit: mm (inch)

Resistor

Power supply output

195.60(7.70)

UI1 to UI4; 50Hz maximum; Min 10ms On/10ms Of - SO output compatible


UI5 to UI16: 1Hz maximum; Min 500ms On/500ms Off - Dry contact
0 to 350 K. All thermistor types that operate in this range are supported.
The following temperature sensors are pre-configured:
- Thermistor : 10K Type 2, 3 (10K @ 25C; 77F)
- Platinum : Pt1000 (1K @ 0C; 32F)
- Nickel : RTD Ni1000 (1K @ 0C; 32F)
RTD Ni1000 (1K @ 21C; 69.8F)
15VDC; maximum 320mA (16 inputs x 20mA each)

Output

57.20
(2.25)
119.40
(4.70)

158.70(6.25)

50.80(2.00)

Universal

0-10VDC linear, digital 0-12VDC (on/off), floating PWM, or 0-20mA (jumper


configurable); software configurable. Built-in snubbing diode to protect
against back EMF, for example when used with a 12VDC relay.
- PWM control : adjustable period from 2 to 65 sec.
- Floating control : requires two consecutive outputs

Min pulse on/off: 500msec.

Adjustable drive time period
- HOA : Hand-Off-Auto switch (when equipped)
Hand position potentiometer range: 0-12.5VDC
- 60mA max. @ 12VDC (60C; 140F)

Load resistance

Minimum 200 for 0-10VDC and 0-12VDC outputs


Maximum 500 for 0-20mA output

Reset fuse

60mA @ 60C; 140F


100mA @ 20C; 68F
* Specifications are subject to change without notice.

16

SAC-C1200I/C1212I
I/O Extension Module for SAC-B1612

Technical Specifications
SAC-C1200I

SAC-C1212I

Electrical
Voltage
Protection
Power Consumption

SAC-C1200I

Key Features

24-point I/O extension module

12 UI, 12 UO(software configurable)

64 MHz

Memory

64 KB Non-volatile Flash, 20 KB RAM


Green LED : Power Status & LAN Tx
Orange LED : Module Status & LAN Rx

Operating Temperature
Storage Temperature
Humidity

0C to 50C; 32F to 122F


-20C to 50C; -4F to 122F
Less than 90% RH

Mechanical

General Features
I/O Extension Module for SAC-B1612
 rogrammable controller for customized control of HVAC facilities including
P
conditioner, refrigerator, boiler etc.

GUI-based HVAC control sequence programming tool provided

Support NiagaraAX-based S-Controller Pro

STM32(ARM Cortex M3) MCU, 32 bit

CPU speed

Environmental

12-point input extension module

SAC-C1212I

Processor

Status Indicator

SAC-C1200I

RS-485
38,400 bps
DIP switch(0-127)

Hardware

SAC-C1212I

Max 50 VA

Communication
Communication Bus
Baud Rate
Addressing

24VAC, 15%, 50/60Hz, Class 2


3.0A user-replaceable fuse
22 VA Typical + all output loads
Max 16VA

Material

ABS

Color

Casing: Black / Connectors: Gray

Dimensions (W x H x D)

195.6mm x 119.4mm x 50.8mm (7.7 x 4.7 x 2.0)

Weight

0.53kg (1.17lbs)

Inputs
Voltage
Current

 uilt-in resistors and jumpers to control I/O eliminating the need for external
B
resistor
 ugged hardware Inputs and Outputs minimizing the need for external
R
protection components

Digital
Input Pulse
types

Resistor

Power supply output

Universal, Software Configurable


- 0 to 10V DC (40k input impedance)
- 0 to 5V DC (high input impedance)
0 to 20mA with 249 jumper configurable internal resistor
Dry Contact
1Hz maximum, 500ms On/500ms Off - Dry contact
0 to 350 K. All thermistor types that operate in this range are supported.
The following temperature sensors are pre-configured
- Thermistor : 10K Type 2, 3 (10K @ 25C; 77F)
- Platinum : Pt1000 (1K @ 0C; 32F)
- Nickel : RTD Ni1000 (1K @ 0C; 32F)
RTD Ni1000 (1K @ 21C; 69.8F)
15VDC; maximum 240mA (12 inputs x 20mA each)

Output

Dimensions

Universal

0-10VDC linear, digital 0-12VDC (on/off), floating PWM, or 0-20mA (jumper


configurable); software configurable. Built-in snubbing diode to protect
against back EMF, for example when used with a 12VDC relay.
- PWM control : adjustable period from 2 to 65 sec.
- Floating control : requires two consecutive outputs3

Min pulse on/off: 500msec.

Adjustable drive time period
- HOA : Hand-Off-Auto switch (when equipped)
Hand position potentiometer range: 0-12.5VDC
- 60mA max. @ 12VDC (60C; 140F)

Load resistance

Minimum 200 for 0-10VDC and 0-12VDC outputs


Maximum 500 for 0-20mA output

Reset fuse

60mA @ 60C; 140F


100mA @ 20C; 68F

Unit: mm (inch)

195.60(7.70)

57.20
(2.25) 119.40
(4.70)

* Specifications are subject to change without notice.


158.70(6.25)

50.80(2.00)

17

SAC-B0608
BACnet Programmable Controller (14-point)
- 6 UI, 8 UO
Technical Specifications
SAC-B0608

Electrical
Voltage
Protection
Power Consumption

24VAC; 15%; 50/60Hz; Class 2


2.0A user-replaceable fuse
14 VA Typical + all output loads, max 23VA

Communication
EOL resistor
Baud Rate
Addressing

Built-in, jumper selectable


9,600/19,200/ 38,400/ 76,800 bps
DIP switch

Hardware
Processor
CPU speed
Memory

Key Features

 rogrammable controller for customized control of HVAC facilities including


P
conditioner, refrigerator, boiler etc.

6 UI, 8 UO(software configurable)

GUI-based HVAC control sequence programming tool provided

Support NiagaraAX-based S-Controller Pro

Status Indicator

Environmental
Operating Temperature
Storage Temperature
Humidity

 uilt-in resistors and jumpers to control I/O eliminating the need for external
B
resistor
 ugged hardware Inputs and Outputs minimizing the need for external
R
protection components

STM32(ARM Cortex M3) MCU, 32 bit


68 MHz
384 KB Non-volatile Flash(applications), 1MB Non-volatile Flash (storage),
64KB RAM
Green LEDs : Power Status & LAN Tx
Orange LEDs : Controller Status & LAN Rx
0C to 50C; 32F to 122F
-20C to 50C; -4F to 122F
Less than 90% RH

Mechanical
Material
Color
Dimensions (W x H x D)
Weight
Installation

ABS
Casing: Black / Connectors: Gray
144.8 x 119.4 x 50.8 mm (5.7 x 4.7 x 2.0)
0.44kg (0.97lbs)
Direct din-rail mounting

Inputs
Voltage
Current
Digital
Input
Pulse
types

Resistor

Power supply output

Dimensions

Unit: mm (inch)

Output

Digital

144.78(5.70)

57.15
(2.25)

119.38
(4.70)

Universal

107.95(4.25)

50.80
(2.00)

Universal, Software Configurable


- 0 to 10V DC (40k input impedance)
- 0 to 5V DC (high input impedance)
0 to 20mA with 249 jumper configurable internal resistor
Dry Contact
Dry contact; 500ms minimum ON/OFF
0 to 350 K. All thermistor types that operate in this range are supported.
The following temperature sensors are pre-configured:
- Thermistor : 10K Type 2, 3 (10K @ 25C; 77F)
- Platinum : Pt1000 (1K @ 0C; 32F)
- Nickel : RTD Ni1000 (1K @ 0C; 32F)
RTD Ni1000 (1K @ 21C; 69.8F)
15VDC; maximum 120mA (6 inputs x 20mA each)
24VAC Triac, digital (on/off), floating, or PWM; software configurable
0.5A continuous
1.0A @ 15% duty cycle for a 10-minute period
- PWM control: adjustable period from 2 to 65sec
- Floating control:
Min pulse on/off: 500msec.
Adjustable drive time period
External power supply
0-10VDC linear, digital 0-12VDC (on/off), floating or PWM; software configurable.
Built-in snubbing diode to protect against back EMF, for example when
used with a 12VDC relay.
- PWM control: adjustable period from 2 to 65sec.
- Floating control:
Min pulse on/off: 500msec.
Adjustable drive time period
- 60mA max. @ 12VDC (60oC; 140oF)
- Minimum resistance 200
- Auto-reset fuse
60mA @ 60oC; 140oF
100mA @ 20oC; 68oF
* Specifications are subject to change without notice.

18

SAC-B0507V
BACnet VAV(Variable Air Volume)

Technical Specifications
SAC-B0507V

Electrical
Voltage
Protection
Power Consumption

24VAC, 15%, 50/60Hz, Class 2


2.0A user-replaceable fuse
3.0A user-replaceable fuse for triacs when using the internal power supply
14 VA typical plus all external loads 85 VA maximum

Communication
Communication Bus
EOL resistor
Baud Rate
Addressing

BACnet MS/TP
Built-in, jumper selectable
9,600/19,200/ 38,400/ 76,800 bps
Field configurable with any SAF-S0100 model

Hardware
Processor
CPU speed
Memory

Key Features

Status Indicator

 ontroller only for VAV box control


C

Meets the requirements of VAV zone applications, including:
- Cooling only VAV boxes
- Cooling with Reheat VAV boxes
- Parallel Fan VAV boxes
- Series Fan VAV boxes
- Dual-Duct VAV system

Accurate on-board air flow sensor for precise air flow monitoring and control at
low and high air flow rates

Built-in actuator with a brushless motor and integrated position feedback
system

Integrated VAV Performance Assessment Control Charts (VPACC) control
sequences auto-detecting abnormal operation of VAV

Covering all industry-standard VAV applications

R ugged hardware Inputs and Outputs minimizing the need for external
protection components

Operating Temperature
Storage Temperature
Humidity

Environmental

Material
Color
Dimensions (W x H x D)
Weight
Motor
Torque
Rotation degree
Fits Shaft Diameter

Belimo LMZS-H brushless DC motor


35 in-lb, 4 Nm
95 adjustable
5/16 ~ ", 8.5 ~ 18.2mm

Inputs
Voltage
Current
Digital
Input Pulse
types

Differential Pressure
Range Accuracy
Power supply output

181.7(7.15)

ABS
Casing: Black / Connectors: Gray
214.3 x 122.7 x 63.0 mm (8.4''x 4.8''x 2.5'' inches)
0.42kg (0.92lbs)

Integrated Damper Actuator

Unit: mm (inch)

32.63
(1.28)

0C to 50C; 32F to 122F


-20C to 50C; -4F to 122F
Less than 90% RH

Mechanical

Resistor

Dimensions

STM32(ARM Cortex M3) MCU, 32 bit


68 MHz
384 KB Non-volatile Flash, 1MB Non-volatile Flash, 64KB RAM
Green LEDs : Power Status & LAN Tx
Orange LEDs : Controller Status & LAN Rx

Universal, Software Configurable


- 0 to 10V DC (40k input impedance)
- 0 to 5V DC (over 40k input impedance)
0 to 20mA with 249 jumper configurable internal resistor
Dry Contact
Dry contact; 500ms minimum ON/OFF
0 to 350 K. All thermistor types that operate in this range are supported.
The following temperature sensors are pre-configured:
- Thermistor : 10K Type 2, 3(10KO @ 25C; 77F)
- Platinum : Pt1000(1K @ 0C; 32F)
- Nickel : RTD Ni1000(1K @ 0C; 32F)
RTD Ni1000(1K @ 21C; 69.8F)
0 ~ 500 Pa (0 ~ 2.0 in. W.C.)
5.5% of reading over operating temperature range
15VDC, max 80mA (4 inputs x 20mA)

122.7(4.83)

Output

Digital

SAC-B0507V

Universal
19.05
(0.75)

125.4(4.94)
15
(0.59)

24VAC Triac, digital (on/off), floating, or PWM; software configurable


0.5A continuous
1.0A @ 15% duty cycle for a 10-minute period
- PWM control: adjustable period from 2 to 65sec.
- Floating control:
Min pulse on/off: 500msec.
Adjustable drive time period
External power supply
0-10VDC linear, digital 0-12VDC (on/off), floating or PWM; software configurable.
Built-in snubbing diode to protect against back EMF, for example when
used with a 12VDC relay.
- PWM control: adjustable period from 2 to 65sec.
- Floating control:
Min pulse on/off: 500msec.
Adjustable drive time period
- 60mA max. @ 12VDC (60C; 140F)
- Minimum resistance 200
- Auto-reset fuse
60mA @ 60C; 140F
100mA @ 20C; 68F
* Specifications are subject to change without notice.

19

SAF-S0100/S0400
LCD Communicating Sensor (Temperature / Humidity)

Technical Specifications
SAF-S0100

SAF-S0400

Electrical
Voltage

16V DC max, Class 2

Power Consumption

400mW typical

LCD Display
Type

47 X 30 mm (1.85 X1.18 inches) with backlight

Symbols

Language-independent icons for mode and operating status

Temperature
resolution

0.1C; 0.1F

Environmental

Key Features

SAF-S0100

5C ~ 40C (-20~+50%)

Humidity

0 ~ 95% RH

Mechanical

LCD communicating sensor to measure the rooms temperature level

SAF-S0400

Operating(Storage)

LCD communicating sensor to measure the rooms temperature, humidity level


Encourage occupants to have greener habits with leaf icon while saving energy costs.

Material

ABS

Color

White

Dimensions (W x H x D) 83.55 x 117.27 x 26.83 mm (3.29 x 4.62 x 1.06 inches)


Weight

0.18 kg (0.4 lbs)

Temperature Sensor

Low energy efficiency

Moderate energy efficiency Higher energy efficiency

Highest energy efficiency

Simple and slim style sensors


Control the room temperature to enhance occupants convenience
Quick access to the network with the built-in LAN port
Extended operation for non-business hours for maintaining comfort as well as
saving power consumption
Release/ set HVAC mode, set point and fan speed
Show the system information including temperature, set point, occupancy and
HVAC mode on the LCD display
Reduce setup cost and enhance system maintenance using single CAT 5e cable

Dimensions

Unit: mm (inch)

Type

10K NTC Thermistor

Range

5C to 40C; 41F to 104F

Accuracy

0.5C; 0.9F

Resolution

0.1C; 0.18F

Humidity Sensor
Function

Communications
Rate

38,400 bps

Communications

RS-485

Wiring

Cable length: 200m (650ft) maximum

Cable Type

T568B Cat 5e network cable, 4 twisted pairs

Connectors

IN : RJ-45
OUT: RJ-45 (pass-through for daisy chain connection)
Network Access Jack: 3.5mm (1/8) stereo plug connector

Daisy-chaining

Ranging from 4 to 12 SAF-S0100/SAF-S0400 sensors depending on the


controller model - See the controllers datasheet
* Specifications are subject to change without notice.

83.55
(32.9)

3.00typ
(0.12)

84.10
(3.31)

60.00
(2.36)

117.27(4.62)

60.00
(2.36)

7.00
(0.28)

26.83
(1.06)

20

Mounting base plate shown detached

SAF-S0500
Adjustable Thermostat Sensor

Technical Specifications
SAF-S0500

Environmental
Operating
Temperature

0C to 50C; 32F to 122F

Storage Temperature

-20C to 70C; -4F to 158F

Humidity

0 ~ 90% RH

Communication
LAN Access Jack

Audio Jack, 1/8"(3.5mm)

Mechanical

Key Features

Material

ABS

Color

White

Dimensions (W x H x D)

117 x 84 x 40 mm (4.62" x 3.29" x 1.58)

Slim, compact style and clean lines well received by architects and building owners

Weight

0.18kg (0.4lbs)

Control the room temperature inside to enhance occupants convenience

Installation

Wall mounting through mounting holes (see figure above for hole positions)

 xtended operation for non-business hours for maintaining comfort as well as


E
saving the power consumption

Output

Occupancy status with an LED indicator


Fan speed selector for improved personal comfort
 ccurate temperature monitoring while some models have setpoint override
A
for increased individual comfort
 uick access to the network as soon as the controller gets started with the
Q
built-in LAN port
Mounted on the wall or the electric cabinet with a separate sub-base

Types

10K Type II Thermistor (10k @ 25C; 77F)

Range

0C to 50C; 32F to 122F

Accuracy

0.5C, 0.9F

Functions
Setpoint Adjustment

10k linear rotary potentiometer

Occupancy override

Momentary push-button switch short-circuits the thermistor

LED

Green, powered by 12 VDC or 24 VAC

Fan speed Selection

5-position rotary-switch with factory-programmed resistance values

Auto

Off

2,500

Fan speed 1

5,000

Fan Speed 2

7,500

Fan speed 3

10,000
* Specifications are subject to change without notice.

Dimensions

Unit: mm (inch)

84(3.29)

25.4
(1.00)

3.00typ
(0.12)

84(3.31)

60(2.36)

117(4.62)

60(2.36)

7.00
(0.28)

Mounting base plate shown detached

21

SAP-E1000/E1100/E2000/E2100
Enclosure for controllers

SAP-E1000
SAP-E1100

SAP-E2000
SAP-E2100

Technical Specifications

Key Features

SAP-E1000

SAP-E1000

Medium Cabinet(SAP-E2100 including intercom)


Preventing physical damage with curved edge
Front-Acrylic cut-out for intercom setting

SAP-E2000

SAP-E2100

Steel

Material

SAP-E2000

Intercom

Compact Cabinet(SAP-E1100 including intercom)

SAP-E1100

Color

Silver

Dimensions (WxHxD)

750 x 900 x 300 mm (29.5''x 35.4''x 11.8'') 800 x 1,500 x 300 mm(31.5''x 59''x 11.8'')
39 kg (86 lbs)

Weight

62 kg (137lbs)
* Intercoms require additional order.
* Specifications are subject to change without notice.

Dimensions

Unit: mm

300
800(11.8'')
300

750(29.5'')
750

750

1500(59'')
1500(59'')

900
900(35.4'')
900

SAP-E1000 / SAP-E1100
22

SAP-E2000 / SAP-E2100

SAC-L0404S/L0408S
Sunblind Controllers (4CH/8CH)

Technical Specifications
SAC-L0404S

SAC-L0408S

Electrical
Voltage

230VAC 50/60Hz

Protection

Fuse or circuit breaker 16A

Hardware
SAC-L0404S

Inputs

RJ-9 (Max 4)

Outputs

On/Off, 230 VAC / 5 A

EMC

EN61000-6-x, EN61000-4-x

Status Indicator

Power supply LED


Outputs status LED
Network status LED

Control Range

Max 4 blinds

SAC-L0408S

Key Features

Material

Integration with building system via standard protocol Lontalk

Polycarbonate
Plate

Black

Cover

Black

 unblind control according to sunlight and room occupancy optimizes energy


S
savings made as a result of HVAC parameters

Color

A comprehensive sunblind controller range: 4 or 8 sunblinds control, 230VAC

Mechanical Protection

IP 20

One controller to manage sunblinds in several rooms (depending on installation)

Dimensions (W x H x D)

290 x 154 x 50mm

 rders emitted by a remote control, presence and Lux level measure information
O
given by multi-sensors

Box (W x H x D)

300 x 200 x 55 mm

Weights

1.2Kg

Modular solution : it can be adapted to an office repartitioning

Network

Installation on a double DIN rail or fixed onto the wall

Interface

Pluggable connectors: Easier connection in ceilings


 Pin service : push button in front of the controllers

Environmental

Max 8 blinds

Mechanical

LonWorks FTT-10A 78kbps, twisted pair

Operating Temperature

+5 ~ +45

Storage Temperature

-20 ~ +70

Humidity

+20% ~ +90% RH

Security

EN60669-2-1
* Specifications are subject to change without notice.

Dimensions

Unit: mm

290mm

90mm

154mm

275mm

6.5mm

6.5mm