Datasheet - Sensor Clamps 200

Sensor mounting clamps can be used for mounting WT100 series sensors as an alternative to stud
welding on pipes operating up to 200C(390F).

Table of Contents
System Documentation ......................................................................................................................................................... 2
Clamp Specifications .............................................................................................................................................................. 2
Details

................................................................................................................................................................................. 3

Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK
www.permasense.com
support@permasense.com
+44 20 3002 0922

System Documentation
Installation
guide
Sensor
Clamps Series
2

Datasheet
Sensor Clamps
200

Datasheet
WT100

Clamp Specifications
Material Specifications
Clamp material
Coating
Stud material
Pipe operating temperature

Stainless Steel 316L


Intertherm 228 + Grey : Ral code 7004
Stainless Steel 316L
-30 to 200C (-22 to 390F)

Supplied hardware
Part
Clamp half (2 halves make one ring)
Clamp bolt M16 X 130
M16 washer
M16 disc springs
M16 Nordlock washer
M16 Nut
M8 nut on each stud

Number
4
4
8
64
4
4
12

Material
SS316L
A4
A4
SS302
A4
A4
A4

Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK
www.permasense.com
support@permasense.com
+44 20 3002 0922

Details
Mechanical details
Nominal pipe
DIA (Inches)
Weight Kg [lb]
Fully
assembled
Number of
sensor
mounting
positions
Torque Nm
[lbf.ft]
Disc Spring
configuration
on every M16
bolt

10

12

14

16

18

20

24

[15.44]
7

[17.64]
8

[19.85]
9

[22.05]
10

[24.26]
11

[26.46]
12

[30.87]
14

[33.08]
15

[37.49]
17

6 equispaced. See Figure 2.


30 [22]
4 - 4 - 4 - 4 See Figure 1.

Figure 1 : Disc springs configuration on an M16 fixing


assembly

Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK
www.permasense.com
support@permasense.com
+44 20 3002 0922

Dimensions
Clamp dimensions are shown in Figure 2:

Figure 2 : Clamp dimensions. See table below.


Nominal pipe DIA
(Inches)
[Inches]
A
mm
[Inches]
B
mm
[Inches]
C
mm
[Inches]
D
mm
[Inches]
E
mm
[Inches]
F
mm

10

12

14

16

18

20

24

[6.77]
172

[8.82]
224

[10.94]
278

[12.99]
330

[14.17]
360

[16.22]
412

[18.27]
464

[20.31]
516

[24.33]
618

[4.76]
121
[5.35]
136
[9.72]
247
[11.54]
293
[1.57]
40

[5.79]
147
[6.38]
162
[11.85]
301
[13.90]
353
[1.57]
40

[6.85]
174
[7.44]
189
[14.21]
361
[16.26]
413
[1.57]
40

[7.87]
200
[8.46]
215
[16.26]
413
[17.95]
456
[1.57]
40

[8.46]
215
[9.06]
230
[17.52]
445
[19.80]
503
[1.57]
40

[9.49]
241
[10.08]
256
[19.49]
495
[21.69]
551
[1.57]
40

[10.51]
267
[11.10]
282
[21.69]
551
[24.06]
611
[1.57]
40

[11.54]
293
[12.13]
308
[23.78]
604
[26.14]
664
[1.57]
40

[13.54]
344
[14.13]
359
[27.83]
707
[30.20]
767
[1.97]
50

Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK
www.permasense.com
support@permasense.com
+44 20 3002 0922
Revision 1, 16/12/2013 Permasense Ltd. Permasense is a registered trademark of Permasense Ltd.