Agenda
Introduction
System and Transformer Design 800 kV HVDC
Dielectric Stress and Insulation Design
Projects, Developments and Trends
Page 2
25.10.2010
Introduction
China Project Overview
1. Hami C. China
800 kV, 6400 MW, 2018
2. Xijaba Shanghai
800 kV, 6400 MW, 2011
3. Xiluodu Hanzhou
800 kV, 6400 MW, 2015
Jilin
4. Xiluodu Hunan
800 kV, 6300 MW, 2013
Liaoning
Heilongjiang
12
23
14
13
16
Xinjiang
Beijing
Inrfar Mongolia
Gansu
Shandong
Shanxi
22
Henan
Jiangsu
Shaanxi
Anhuj
Shanghai
2
Hubai
Sichuan &
Chongqing
Xizang
Jiangxi
Hunan
Guizhou
Yunnan
8
11
18
19
Qinghai
16
Hebei
17
Ningxia
Tianjin
21
15
Zheijang
Fujian
Taiwan
Guangdong
Guangxi
Page 3
25.10.2010
10
Bangkok
9. Nuozhadu Guangdong
800 kV, 5000 MW, 2015
10. Jinghong Thailand
3000 MW, 2013
20
Hainan
Introduction
HVDC (High Voltage Direct Current) Transmission is more efficient for Long
Distances (>600km) or Cable Links (>50km) than HVAC (HV Alternating Current)
AC
DC
AC line cost
[$]
cost benefit
AC transmission
Page 4
25.10.2010
cost benefit
DC transmission
[miles]
Advantages of HVDC:
- Low Line Cost, but Converter Cost
- No capacitive charging currents less losses and CO2 emissions
- Firewall function for grids
- Load flow regulation (HVDC Plus)
- Connection for different frequencies
- High Transmission Power density
(usage of less land or space)
- Offshore connections for
wind parks
or oil rigs (substitution of CO2
emissions from diesel generators)
Introduction
HVDC at 800 kV for economical, long-distance electricity transfer
= HVDC 800 kV
Page 5
25.10.2010
Introduction
800 kV DC Overhead Line Towers
Page 6
25.10.2010
Introduction
Clear economical advantage of an 800 kV HVDC solution
AC
765 kV
Page 7
25.10.2010
DC
500 kV
DC
800 kV
System Design
Comparison of schematics of 500 kV and 800 kV HVDC systems
500kV HVDC
single phase
3 winding
transformers
or
single phase
2 winding
transformers
800 kV
single phase
2 winding
transformer
+250 kV
+500 kV
+250 kV
-500 kV
-250 kV
25.10.2010
+200 kV
+200 kV
+800 kV
+200 kV
+200 kV
-250 kV
Page 8
800kV HVDC
-200 kV
-200 kV
System Design
Insulation Coordination - Insulation Levels
BIL / SIL: 1800 kV / 1600 kV
25.10.2010
Receiving Station
Yunnan - Guangdong
- 800 k
- 400
+ 400
+ 80
Page 10
25.10.2010
0 kV
DC
k V DC
kV D
V DC
Transformer Design
1.3
Lower Yoke
Insulating system
is to design both
for AC and DC
Page 11
25.10.2010
1.1
2.1
Valve
Winding
2.2
Tap
HV
Winding
1.1
Valve
Winding
Core
2.1
HV
Winding
Upper Yoke
Tap
Upper Yoke
Core
1.3
2.2
Lower Yoke
Insulating system
is to design only
for AC
Insulating system
is to design only
for AC
Insulating system
is to design both
for AC and DC
AC Voltage
Switching Impulse
0
1.0
Spannung
voltage U(t)/
Spannung
voltage U(t)/0
1.0
0.5
0
-0.5
-1.0
0
10
20
Zeit t
time
30
ms
0.2
0.5
1.0
1.5
2.0 2.5
Zeit t
time
3.0
ms
4.0
1.0
Spannung
voltage U(t)/0
Spannung
voltage U(t)/
0.4
1.0
0.8
0.6
0.4
0.2
Page 12
0.6
0
0
50
0
0
0.8
10
20
30
25.10.2010
40 50
Zeit t
time
60
80
0.8
0.6
0.4
0.2
0
0
4
Zeit t
time
voltage U(t)/
1.0
0.8
0.6
0.4
0.2
0
30
60
time t
min
120
voltage U(t)/
Usual cycle:
90min(-) PR 90min(+) PR 45 min(-)
Applied DC voltage duration 90 min,
negative polarity
First PR within 1min2min
90 min positive polarity
Second PR within 1min..2min
45 min negative polarity
0
-0.5
-1.0
PD-measurement
Page 13
25.10.2010
40
90
135
time t
min
225
D 0 r E
J E
Permittivity
pressboard / oil r ratio = 2
Page 14
25.10.2010
Conductivity
pressboard / oil ratio > 50
10-16
10 -1 2
1 0 -12
10
-1 3
10
-13
Pressboard
10-18
O il
-1
Conductivity
Leitfhigkeit
[S m[S
] m-1]
1 0 -11
-1
-1
Conductivity
Leitfhigkeit
[S m[S]m ]
10 -1 1
Pressboard
RIP
RIP
10-13
P res sb o ard , H
P re s sb o a rd , H
-15
10
10-10
10 -1 4
1 0 -14
10 -1 5
P res sb o ard , T
1 0 -15
P re s s b o a rd , T
10-12
Oil
l
Porzellan
10-7
1
1
10
1 00
Field
S tre n1gth
10
00
F el ds t r ke
1 00 0
[k1V
/m m ]
00 0
20
10-9
40
20
40
[k V / m m ]
Page 15
25.10.2010
Porcelain
60
80
100
120
60
80
Temperature
[C]100
120
Temperatur [C]
Applied Voltage
Equipotential Lines
1.00
Page 16
25.10.2010
Page 17
25.10.2010
Page 18
25.10.2010
Page 19
25.10.2010
Commercial Operation:
2009 Pole 1
1,418 km
5,000 MW
2010 Pole 2
+/- 800 kV DC
Yunnan-Guangdong
Quelle: Prof, Retzmann
Page 20
25.10.2010
Page 21
25.10.2010
Page 22
25.10.2010
Page 23
25.10.2010
Page 24
25.10.2010
Page 25
25.10.2010
800 kV DC
800 kV DC
2 x 400 kV DC
Page 26
25.10.2010
800 kV DC
Page 27
25.10.2010
400 kV DC
Page 28
25.10.2010
Page 29
29
02-2010
25.10.2010
800 kV DC
Dr. MarioESchenk,
T PS SL/Re
Frank Trautmann
Yunnan-Guangdong
UHV DC Converter
800 kV DC
Page 30
25.10.2010
Xiangjiaba-Shanghai
Shanghai
Leshan
Chongqing
Xiangjiaba
Xiluodu left
Xiluodu right
Nanhui
Wuhan
Xiangjiaba
Xiluodu-Zh
uzhou
Xiluodu
left
Xiluodu rightXiluodu-Zhe
xi
Zhexi
Changsha
970km
Zhuzhou
km
1728
2,071 Km
6,400 MW
+/- 800 kV DC
Guangdong
Quelle: Prof, Retzmann, Siemens
Page 31
25.10.2010
2000
2008
in operation
in operation
Page 32
25.10.2010
in operation
Study
Sunan
Leshan
Chongqing
To Sichuan Power Grid
Jinping Plant I
Jinping Plant I I
Guandi
Linping
Xichang
Wuhan
Changsha
2,237 km
* 6.4 GW
initially
* 7,200 MW
+/- 800 kV DC
Planned for 2013
Guangdong
25.10.2010
840 km
Shanghai
1. 800 kV
Yunnan
Guangdong
2. 800 kV
Xiangjiaba
Shanghai
3. 800 kV
Study
1. 1100 kV
Study
5000 MW
250 MVA
li0
525 kV/3
168.85 kV/3
6400 MW
321 MVA
li0
530 kV/3
170.3 kV/3
7200 MW
360 MVA
li0
530 kV/3
170.3 kV/3
Rated Power
System
Transformer
Vectorgroup
Ratio
Weights
Total
Oil
Insulationlevel
Line (HV)
Valve (LV)
AC (60min)
LI
SI Potential
DC (2h)
PR -/+/(90/90/45)min
Page 34
25.10.2010
512 t
142 t
909 kV
912
1254 kV
969 kV
551.8 t
148.8 t
912 kV
912 kV
LI 1550 kV SI 1175 kV AC 680 kV
912
1800 kV
1600 kV
1258 kV
970 kV
912
1258 kV
970 kV
Transforming know-how
into solutions.
Siemens Transformers.
25.10.2010
Mario Schenk
Director Engineering and R&D, Power Transformers Nuremberg
1991
till 1997
1997-2002
2002
11/2002-10/2007
2004-2006
since 11/2007
Page 36
25.10.2010
Electrician
Electrical Engineering (HV and High Current)
(Dipl.-Ing. TU Dresden and Virginia Tech)
Doctorate, Scientific Assistant (Dr.-Ing. TU Dresden)
Thermal Design of High Voltage Equipment
ABB Switzerland AG
R&D, Design of Generator Circuit Breakers
SGB Regensburg (SGB/SMIT Group)
Director R&D, Director Engineering
Executive MBA
(Northwestern University Chicago, WHU Koblenz)
Siemens AG, Power Transformers Nuremberg
Director Engineering and R&D
responsible for R&D, Electrical Design
Mechanical Design and Production Technology