Documente Academic
Documente Profesional
Documente Cultură
SecretInternal public
Preparedby
Viki Zhang
Date
2012-02-29
Checked by
Date
2012-02-29
Approved by
Patrick Ren
Date
2012-02-29
Revision History
Date
Revision History
2012-02-29
First Release
Note
1/9
Address: HYT Tower, Hi-Tech Industrial Park North, Nanshan District, Shenzhen, ChinaPost Code:518057Fax: +86-755-86137136
Hotline: +86-755-86137081
http://www.hytera.com
Purpose
Through config M30(PSTN gateway), to achieveRD98X(Firmware R4.0 and above) phone interconnect
feature.
2.
PSTN Gateway
PSTN Net
2/9
Address: HYT Tower, Hi-Tech Industrial Park North, Nanshan District, Shenzhen, ChinaPost Code:518057Fax: +86-755-86137136
Hotline: +86-755-86137081
http://www.hytera.com
PSTN Net
The radio send Access code to enter PSTN system, to establish a call
The radio send De-Access codeto to quit PSTN system.
3.
2)
3)
RF detect cable
4)
Tuning tool
5)
M30 connect cable (To connect the M30&RD98Xs DB26 port, need to DIY)
3/9
Address: HYT Tower, Hi-Tech Industrial Park North, Nanshan District, Shenzhen, ChinaPost Code:518057Fax: +86-755-86137136
Hotline: +86-755-86137081
http://www.hytera.com
4.
Pin
Name
Type
+12VDC
+12VDC input
GND
Ground
Electrical Specifications
Note
10.5V-15.0V
Repeater
pin#4
SWB+
output
13.2V15%, output 1A, M30 rated
current 150mA
Connect to repeater pin #17
DISC
Discriminator
audio input
GND
Ground
-40 to +10dBm.Hi/Lo
selector
50k input.25mV to 6V
p-p
audio
TX AUD
Transmit
output
GND
Ground
PTT
Push-To-Talk
output
COR IN
Carrier
input
detect
DECODE
PL/DPL
Tone
Validation Input
<1.5V or >3.5V
NC
10
AUX
OUT
Auxiliary Output
NC
4/9
Address: HYT Tower, Hi-Tech Industrial Park North, Nanshan District, Shenzhen, ChinaPost Code:518057Fax: +86-755-86137136
Hotline: +86-755-86137081
http://www.hytera.com
2)
J1
+12V DC IN
GND
DISC
GND
TX AUDIO
GND
PTT
COR IN
DECODE
AUX OUT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
1
2
3
4
5
6
7
8
9
10
PSTN M30
J2
1
2
DB26-GPIO4
SWB+
5
GND
MIC-IN
RX AUDIO
9
10
11
12
13
14
15
DB26-PTT
17
18
19
20
21
22
23
24
25
26
RD980 DB26
5.
Unmodified (JP7)
Modified (JP7)
Change JP8 wire jumper: JP8 can only on position B or C.When the pin#3 of repeater is active by
low level,JP8 should be on position C. Otherwise, When the pin#3 of repeater is active by high
level,JP8 should be on positionB.Because we set RD98X is active by low level, so JP8 is on
position C.
Address: HYT Tower, Hi-Tech Industrial Park North, Nanshan District, Shenzhen, ChinaPost Code:518057Fax: +86-755-86137136
Hotline: +86-755-86137081
http://www.hytera.com
3)
Connect analyzer(HP8921A), RD98X, M30 and the cables we mentioned above( include RF detect cable,
one end to analyzer Audio-In port, another to detect the mainboards signal.
4)
Adjust the DISC audio in gain: Let analyzer produce a 3KHz frequency deviation/1KHz modulated audio
signal, to let it DB26 pin produce 1KHz/800mV audio, adjust RECEIVE LEVEL(R4) on M30 panel.Let
IC U1s pin#14 is 1Vp-p. It means the AC LEVEL of analyzers DUPLEX TEST is 1V.The detail steps as
follows:
Set RD98X under the current analog channel(we already know the Tx/Rx frequency is
463.075/453.075MHz), the setting of analyzer as below:
Input a -47dBm RF signal, use RF detect cable to detect R6 on M30 mainboard. And use the tuning
tool to adjust M30 RECEIVE LEVEL on rear panel, to let AC LEVEL on analyzer is 1V.
6/9
Address: HYT Tower, Hi-Tech Industrial Park North, Nanshan District, Shenzhen, ChinaPost Code:518057Fax: +86-755-86137136
Hotline: +86-755-86137081
http://www.hytera.com
Note: If you found after several tries of adjustment on RECEIVE LEVEL, it is still very hard to
adjust AC LEVEL to 1V, that means the receive gain on M30 mainboard is not enough, you can
modify JP1 to choose different gain path. When JP1 is on position A it is low gain path;when JP1 is
on B position it is high gain path. Here we adjust JP 1 on B position.
Unmodified(JP1)Modified(JP1)
5)
Note: the pin#3 setting is different under analog and digital channels.Andplease set pin#16 is Ext
7/9
Address: HYT Tower, Hi-Tech Industrial Park North, Nanshan District, Shenzhen, ChinaPost Code:518057Fax: +86-755-86137136
Hotline: +86-755-86137081
http://www.hytera.com
Usephone enter M30s control mode( M30 can use CONNECT button to establish a connection,
press 12123#, then enter 92#, let M30 produce a 1KHz audio signal on its pin#5, remaining for 30s,
adjust TRANSMIT LEVEL(R5) on M30 rear panel, let it output 80mV audio signal or let repeater
produce 3KHz frequency deviation.(Because we adjust RF frequencydeviation to 3KHz under Tx
mode of analyzer),if this method doesnt work, please set JP3 toposition A(JP3 can only on position
A or B. Default pin#3 is in position B, low gain path; if set it on position A it is high gain path. Here
we choosethe default position B.)
8/9
Address: HYT Tower, Hi-Tech Industrial Park North, Nanshan District, Shenzhen, ChinaPost Code:518057Fax: +86-755-86137136
Hotline: +86-755-86137081
http://www.hytera.com
6.
Adjust TRANSMIT
Let FM Deviation 3KHz
Use PD78X to try dial the phone, and test if phone interconnect function works well.
This adjustment of M30 is done.
Other commands of M30 you may need
1) Busy tone detect: Please open this function in whole call conversation, the default setting is 20s after
conversation begin. Please use following command to change it
12123#87#99#
2) Call Limit time: we need change call limit time to 10 minutes, the default setting is 3 minutes. Please use
following command to change it
Change to 5 minutes:12123#35#99#
Change to 10 minutes:12123#34#99#
9/9
Address: HYT Tower, Hi-Tech Industrial Park North, Nanshan District, Shenzhen, ChinaPost Code:518057Fax: +86-755-86137136
Hotline: +86-755-86137081
http://www.hytera.com