Sunteți pe pagina 1din 21

TRABAJO ENCARGADO

CURSO: ALBAILERIA ESTRUCTURAL


ESTUDIANTE: FRAY JESUS SEGURA NINA
CICLO: X
PARAMETROS A CONSIDERAR:
Z
S
3
0

U
B

Ro
6

Ia
0.85

Ip
1

DENSIDAD MINIMA DE MUROS


Z= 0.35
U= 1.3
S= 0.8
N= 4
Ap= 137.08

M2

CONCRETO ARMADO -MURO:


X2(m)
t= tc*(Ec/Em)
0.87
tc=
0.13
Ec=
2000000 tn/m2
Em=
300000 tn/m3

Muro
X1
X2
X3
X4
X5
X6
X7

Muro
Y1
Y2
Y3
Y4
Y5
Y6
Y7

fm = 600

Aparejo
soga
CA
soga
soga
soga
soga
soga

Direccion X-X
Espesor t(m)
0.13
0.87
0.13
0.13
0.13
0.13
0.13

Largo L(m)
3.13
1.50
3.13
3.10
3.13
2.60
2.73

L*t
0.407
1.300
0.407
0.403
0.407
0.338
0.355

Nveces
2.0
2.0
2.0
2.0
2.0
2.0
1.0

Aparejo
soga
soga
soga
soga
soga
soga
soga

Direccion Y-Y
Espesor t(m)
0.13
0.13
0.13
0.13
0.13
0.13
0.13

Largo L(m)
2.60
2.60
3.10
3.10
3.10
3.10
4.13

Area(m2)
0.338
0.338
0.403
0.403
0.403
0.403
0.537

N
2.0
2.0
2.0
2.0
2.0
2.0
1.0

ESFUERZO AXIAL MAXIMO

Direccion Y-Y

Muro

Aparejo

Y1
Y2
Y3
Y4
Y5
Y6
Y7

soga
soga
soga
soga
soga
soga
soga

Espesor t(m) Largo L(m)


0.13
0.13
0.13
0.13
0.13
0.13
0.13

2.60
2.60
3.10
3.10
3.10
3.10
4.13

Area(m2)

H(m)

0.338
0.338
0.403
0.403
0.403
0.403
0.537

2.40
2.40
2.40
2.40
2.40
2.40
2.40

TARRAJEO
PESO (tn/m3)
2
Espesor (m)
0.02

Direccion X-X

Muro

Aparejo

X1
X2
X3
X4
X5
X6
X7

soga
CA
soga
soga
soga
soga
soga

Espesor t(m) Largo L(m)


0.13
0.87
0.13
0.13
0.13
0.13
0.13

3.13
1.50
3.13
3.10
3.13
2.60
2.73

Area(m2)

H(m)

0.407
1.300
0.407
0.403
0.407
0.338
0.355

2.40
2.40
2.40
2.40
2.40
2.40
2.40

TARRAJEO
PESO (tn/m3)
2

Espesor (m)
0.02

NCARGADO
CODIGO:
FECHA:

S/C
250

2012155158
6/24/2016

ACABADOS
NO

Fm
60

LOSA
14

(L*t)
L*t/Ap
ZUSN/56
>=

6.8783
0.0502
0.0260
SI CUMPLE

SI CUMPLE
NO CUMPLE

L*t
L*t/Ap
ZUSN/56
>=

5.1129
0.0373
0.0260
SI CUMPLE

SI CUMPLE
NO CUMPLE

137.08

L*t
0.8138
2.6
0.8138
0.806
0.8138
0.676
0.3549

Suma:L*t*N
0.676
0.676
0.806
0.806
0.806
0.806
0.5369

Fm=
H (m)=
P.Espcfc.Muro

600
2.4
1.8

tn/m2
m
tn/m3

LOSA MACIZA:
t=
P.Espcfc.Conc.

0.14
2.4

METRADOS

Area Tributaria

P.Espcfc.

P.Muro(tn)

3.24
3.24
8.03
5.51
8.79
4.14
4.18

1.80
1.80
1.80
1.80
1.80
1.80
1.80

1.46
1.46
1.74
1.74
1.74
1.74
2.32

B
H
P.Espcfc.Conc.

VIGA SOLERA - Y
0.13
m
0.3
m
2.4
tn/m3

P.Losa(tn) P.Tarrajeo(tn)
1.09
1.09
2.70
1.85
2.95
1.39
1.40

0.25
0.25
0.30
0.30
0.30
0.30
0.40

VIGA DINTEL - Y
B
0.13
H
0.12
P.Espcfc.Conc.
2.4

METRADOS

Area Tributaria

P.Espcfc.

P.Muro(tn)

2.84
3.92
5.82
7.02
2.31
3.40
2.20

1.80
2.40
1.80
1.80
1.80
1.80
1.80

1.76
7.49
1.76
1.74
1.76
1.46
1.53

B
H

VIGA SOLERA - X
0.13
m
0.3
m

P.Losa(tn) P.Tarrajeo(tn)
0.95
1.32
1.96
2.36
0.78
1.14
0.74

B
H

0.30
0.14
0.30
0.30
0.30
0.25
0.26

VIGA DINTEL - X
0.13
0.12

P.Espcfc.Conc.

2.4

tn/m3

P.Espcfc.Conc.

2.4

E.020
PISO TIPICO
AZOTEA

PISO TIPICO

SERVICIO

P.Viga(tn)

S/C (tn/m2)

S/C (tn/m2)

P.D(tn)

P.L(tn)

P.D+P.L (TN)

0.24
0.24
0.29
0.29
0.29
0.29
0.15

0.25
0.25
0.25
0.25
0.25
0.25
0.25

0.10
0.10
0.10
0.10
0.10
0.10
0.10

3.04
3.04
5.03
4.18
5.28
3.72
4.27
28.57

0.81
0.81
2.01
1.38
2.20
1.04
1.05
9.28

3.85
3.85
7.03
5.56
7.48
4.75
5.32

NTEL - Y
m
m
tn/m3

E.020
PISO TIPICO
AZOTEA

PISO TIPICO

SERVICIO

P.Viga(tn)

S/C (tn/m2)

S/C (tn/m2)

P.D(tn)

P.L(tn)

P.D+P.L (TN)

0.12
0.14
0.12
0.29
0.12
0.24
0.10

0.25
0.25
0.25
0.25
0.25
0.25
0.25

0.10
0.10
0.10
0.10
0.10
0.10
0.10

3.13
9.09
4.13
4.69
2.95
3.10
2.64
29.72

0.71
0.98
1.46
1.76
0.58
0.85
0.55
6.88

3.84
10.07
5.59
6.44
3.53
3.95
3.19

NTEL - X

TOTAL =
m
m

58.29

16.16

tn/m3

AZOTEA

SERVICIO

TOTAL MURO

P.D(tn)

P.L(tn)

P.D+P.L (TN)

Npisos

Azotea

P.D+P.L (TN)

3.04
3.04
5.03
4.18
5.28
3.72
4.27
28.57

0.32
0.32
0.80
0.55
0.88
0.41
0.42
3.71

3.37
3.37
5.83
4.73
6.16
4.13
4.69

3.00
3.00
3.00
3.00
3.00
3.00
3.00

1.00
1.00
1.00
1.00
1.00
1.00
1.00

14.92
14.92
26.93
21.40
28.60
18.40
20.65

AZOTEA

SERVICIO

TOTAL MURO

P.D(tn)

P.L(tn)

P.D+P.L (TN)

Npisos

Azotea

P.D+P.L (TN)

3.13
9.09
4.13
4.69
2.95
3.10
2.64
29.72

0.28
0.39
0.58
0.70
0.23
0.34
0.22
2.75

3.41
9.48
4.71
5.39
3.18
3.44
2.86

3.00
3.00
3.00
3.00
3.00
3.00
3.00

1.00
1.00
1.00
1.00
1.00
1.00
1.00

14.93
39.69
21.47
24.72
13.77
15.27
12.42

58.29

6.46

CON 01
CON 02
CON 03

Pm/L*t
0.2*Fm*(1-(H/(35*t))^2)
0.15*Fm

CON 01

CON 02

CON 03

ok

Falla
(tn/m2)

(tn/m2)

(tn/m2)

ESFUERZO MAX.

44.15
44.15
66.83
53.11
70.97
45.65
38.47

86.61
86.61
86.61
86.61
86.61
86.61
86.61

90
90
90
90
90
90
90

ok
ok
ok
ok
ok
ok
ok

CON 01

CON 02

ok
ok
ok
ok
ok
ok
ok

CON 03

ok

Falla
(tn/m2)

(tn/m2)

(tn/m2)

ESFUERZO MAX.

36.70
30.53
52.77
61.33
33.84
45.18
34.99

86.61
119.25
86.61
86.61
86.61
86.61
86.61

90
90
90
90
90
90
90

ok
ok
ok
ok
ok
ok
ok

ok
ok
ok
ok
ok
ok
ok

CALCULO DE LA CORTANTE BASAL


PARAMETROS DE SITIO
a) ZONIFICACION (Z)
De acuerdo al Mapa de Sismos.

ZONA:
4
3
2
1

Z
0.45
0.35
0.25
0.1

ZONA :

0.35

b) CONDICIONES GEOTECNICAS (S)

De acuerdo al Reglamneto Nacional de Edificaciones el suelo es: tipo


S= 0.8
TP = 0.30 s
TL = 3.00 s
c) CATEGORIA DE LA EDIFICACION
El uso de la edificacion :
U= 1.3

d) SISTEMA ESTRUCTURAL
La estructura es de Albaileria Confinada por lo que el coeficiente de reduc
R= 5.1

Ro= 6
Ia= 0.85
Ip= 1

e) PERIODO FUNDAMENTAL
El periodo fundamental se calcula mediante la formula:
T = hn / Ct

hn = 10.08
Ct = 60
T = 0.17 s

f) FACTOR DE AMPLIFICACION SISMICA


El factor de amplificacion sismica se calculara mediante la formula:
Condicion 01:
Condicion 02:
Condicion 03:

T<TP
TP<T<TL
T>TL

C = 2.5
C = 2.5 ( TP / T )
C = 2.5 ( TP *TL/ T^2 )

TP = 0.30 s
TL = 3.00 s
como Cumple la condicion T<Tp, Entonces:

C=

CALCULO DE FUERZA SISMICA EN ALTURA:


Piso

CM

CV

PESO SISMICO

hi

58.29

16.16

66.37

2.52

58.29

16.16

66.37

5.04

58.29

16.16

66.37

7.56

Azotea

58.29

6.46

61.52

12.60

260.63

V=

46.50

CENTRO DE MASA (m)


Muro
X1
X2
X3
X4
X5
X6
X7
X1
X2
X3
X4
X5
X6
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Y1
Y2
Y3
Y4
Y5
Y6
TOTAL

P x(Tn)
14.93
39.69
21.47
24.72
13.77
15.27
12.42
14.93
39.69
21.47
24.72
13.77
15.27

272.12

P y(Tn)

xi (m)
15.17
10.35
15.17
12.18
15.17
10.90
8.37
1.57
6.38
1.57
4.55
1.57
5.83

14.92
14.92
26.93
21.40
28.60
18.40
20.65
14.92
14.92
26.93
21.40
28.60
18.40
271.01

Xcm =

yi (m)

1.3
6.83
1.55
6.58
2.58
6.58
6.07
1.3
6.83
1.55
6.58
2.58
6.58

8.37

Ycm =

Edificaciones el suelo es: tipo

S0

a por lo que el coeficiente de reduccion es:

culara mediante la formula:

C < = 2.5

C/R

0.490196078 >0.125

2.50

Pxh

alf.

Fi (Tn)

167.25

0.09

4.37

334.50

0.19

8.75

501.75

0.28

13.12

775.16

0.44

20.27

1.00

46.50

1,778.66

Pi xi
226.53
410.79
325.71
301.05
208.89
166.47
103.93
23.44
253.22
33.71
112.46
21.62
89.04

Pi yi

19.397
101.911
41.746
140.837
73.788
121.059
125.364
19.397
101.911
41.746
140.837
73.788
121.059
2276.87 1122.840

4.14