COMMISSION LECTROTECHNIQUE
INTERNATIONALE
NORME DE LA CE1
I N T E R N AT1 O N A L E L E C T R O T E C H N I C A L COM M I S S I 0 N
IEC STANDARD
Publication 96-3
Premire dition - First edition
1982
Radio-frequency cables
Part 3: General requirements and tests for single-unit coaxial cables
for use in cabled distribution systems
OCEI 1982
Droits de reproduction rservs - Copyright
- all rights
reserved
Genve, Suisse
--``,,,,,`,``,,,,```,````,,```,-`-`,,`,,`,`,,`---
I E C 76 P T * 3 8 2
48Li487L 0 0 7 b L 0 T
Le contenu technique des publications de la CE I est constamment revu par la Commission afin dassurer quil reflte bien ltat
actuel de la technique.
The technical content of I E C publications is kept under constant review by the I EC, thus ensuring that the content reflects
current technology.
Les renseignements relatifs ce travail de rvision, ltablissement des ditions rvises et aux mises jour peuvent tre
obtenus auprs des Comits nationaux de la CE I et en consultant
les documents ci-dessous:
Information on the work of revision, the issue of revised editions and amendment sheets may be obtained from I EC National
Committees and from the following I E C sources :
Bulletin de la C E I
I EC Bulletin
Annuaire de la C E I
IECYearbook
Catalogue of I EC Publications
Publi annuellement
Published yearly
Terminologie
Terminology
For general terminology, readers are referred to I EC Publication 50: Intemational Electrotechnical Vocabulary (I.E.V.), which
is issued in the form of separate chapters each dealing with a
specific field, the General Index being published as a separate
booklet. Full details of the I.E.V. will be supplied on request.
Lattention du lecteur est attire sur les pages 3 et 4 de la couverture, qui numrent les publications de la CE I prpares par le
Comit #Etudes qui a tabli la prsente publication.
--``,,,,,`,``,,,,```,````,,```,-`-`,,`,,`,`,,`---
IECp9bpPT*p3 8 2 ~ ~ ~ ~ 4 8 7 L O O 7 b
-LL m7L
~
C O M M I S S I O N L E C T R O T E C H N I Q U EI N T E R N A T I O N A L E
N O R M E DE LA C E 1
I N T E R N A T I O NA L E L E C T ROT EC H N ICAL C O M M I S S I O N
IEC STANDARD
Publication96-3
Premire dition - First edition
1982
Radio-frequency cables
Part 3: General requirements and tests for single-unit coaxial cables
for use in cabled distributionsystems
Mots cls: Cbles coaxiaux; cbles pour
frquences radiolectriques ; dimensions;
prescriptions ;caractristiques
lectriques.
--``,,,,,`,``,,,,```,````,,```,-`-`,,`,,`,`,,`---
OCEI 1982
Genve, Suisse
prix
Price Fr.s.
Copyright International Electrotechnical Commission
Provided by IHS under license with IEC
16.-
I E C 96 PT*3 82
4844893 0096392 3
-2:
PRAMBULE
1) Les dcisions ou accords officiels de ia CE1en ce qui concerne les questions techniques, prpars par des Comits #Etudes O sont
reprsents tous les Comits nationaux s'intressant ces questions, expriment dans ia plus grande mesure possible un accord
international sur les sujets examins.
2) Ces dcisions constituent des recommandations internationales et sont agres comme telles par les Comits nationaux.
3) Dans le but d'encourager l'unification internationale, la CE1 exprime le vu que tous les Comits nationaux adoptent dans leurs
rgles nationales le texte de la recommandation de la CEI, dans la mesure oi les conditions nationales le permettent. Toute
divergence entre la recommandation de la CE,I et la regie nationale coFespondante doit, dans la mesure du possible, tre indique
en termes clairs dans cette demire.
PRFACE
La prsente norme a t tablie par le Sous-Comit 46A: Cbles pour frquences radiolectriques, du
Comit $Etudes no 46 de la CEI: Cbles, fils et guides d'ondes pour quipements de tlcommunications.
Des projets furent discuts lors des runions tenues Bucarest en 1974 et Stockholm en 1976 et 1980.
'A la suite de cette dernire runion, un projet, document 46A(Bureau Central)lO4, fut soumis l'approbation des Comits nationaux suivant la Regie des Six Mois en octobre 1980.
--``,,,,,`,``,,,,```,````,,```,-`-`,,`,,`,`,,`---
Les Comits nationaux des pays ci-aprs se sont prononcs explicitement en faveur de la publication :
Australie
Autriche
Belgique
Core (Rpublique de)
Danemark
EgYPte
Espagne
Finlande
France
Italie
Roumanie
Royaume-Uni
Sude
Suisse
Turquie
Union des Rpubliques
Socialistes Sovitiques
La prsente norme doit tre utilise conjointement avec la Publication 96-0 de la CEI: Cbles pour
frquences radiolectriques, Partie zro : Guide pour l'tablissement des spcifications dtailles, et la
Publication 96- 1 de. la CE I: Cbles pour frquences radiolectriques, Premire partie: Prescriptions
gnrales et mthodes de mesure.
RADIO-FREQUENCY CABLES
Part 3: General requirements and tests for single-unit coaxial cables
for use in cabled distribution systems
FOREWORD
1) The formal decisions or agreementsof theIECon technical matters, prepared hyTechnica1Committees on which ali the National
Committees having a special interest therein are represented, express, as nearly as possible, an international consensus of opinion
on the subjects dealt with.
3) In order to promote international unification, the IEC expresses the wish that all National Committees should adopt the text of
the IEC recommendation for their national d e s in so far as national conditions will permit. Any divergence between the I E C
recommendation and the corresponding national rules should, as far as possible, be clearly indicated in the latter.
PREFACE
This standard has been prepared by Sub-committee 46A: R.F. Cables, of I EC Technical Committee
No. 46 : Cables, Wires and Waveguides for TelecommunicationEquipment.
Drafts were discussedat the meetings held in Bucharest in 1974and in Stockholm in 1976and 1980. As
a result of this latter meeting, a draft, Document 46A(Central Office)104, was submitted to the National
Committees for approval under the Six Months Rule in October 1980.
The National Committees of the following countries voted explicitly in favour of publication:
Australia
Austria
Belgium
Denmark
Egypt .
Finland
France
Italy
Korea (Republic of)
Romania
Spain
Sweden
Switzerland
Turkey
Union of Soviet
Socialist Republics
United Kingdom
This standard should be used in conjunction with IEC Publication 96-0: Radio-frequency Cables,
Part O: Guide to the Design of Detailed Specifications, and IEC Publication 96-1 :.Radio-frequency
Cables, Part 1: General Requirements and Measuring Methods.
--``,,,,,`,``,,,,```,````,,```,-`-`,,`,,`,`,,`---
2) They have the form of recommendations for international use and they are accepted by the National Committees in that
sense.
- 4 -
1. Domaine d'application
La prsente norme prcise les prescriptionsgnrales et les essais applicables aux cbles coaxiaux,
unitaires, utiliss dans les rseaux de distribution par cbles.
Les prescriptions de la Publication 96-1 de la CEI: Cbles pour frquences radiolectriques,
Premire partie: Prescriptionsgnrales et mthodes de mesure, restent applicables sauf indications
contraires.
2. Dfiditions
En plus des dfinitions de la Publication 96-1, celles qui sont donnes ci-aprs sont applicables :
2.1 Cbles coaxiaux unitaires pour utilisation dans les rseaux de distribution par cbles
Cbles pour fiquences radiolectriques rpondant, d'une faon gnrale, aux prescriptions de la
Publication 96-1 et utiliss pour la distribution de signaux de tlvision (voir paragraphe 3.1 pour
les gammes de frquences). La construction du conducteur extrieur (ou cran) n'est pas limite
une construction en tresse; les constructions donnant une enveloppe mtallique complte sont
couramment utilises.
2.2 Affaiblissement de rflexion
Dfini comme tant gal 20 fois le logarithme base 10 de l'inverse du coefficient de rflexion
.
mesur par rapport une impdance spcifie.
3. Prescriptions
Note.
- Dans les spcifications nationales, des prescriptions plus contraignantes peuvent tre exiges.
--``,,,,,`,``,,,,```,````,,```,-`-`,,`,,`,`,,`---
- 5 -
96-3 O I E C 1982
RADIO-FREQUENCY CABLES
Part 3: General requirements and tests for single-unit coaxial cables
for use in cabled distribution systems
1. Scope
This standard specifies the general requirements and tests applicable to single-unit coaxial cables
for use in cabled distribution systems.
The requirements of I EC Publication 96-1 : Radio-frequency Cables, Part 1: General Requirements and Measuring Methods, are applicable unless otherwise stated.
2. Definitions
- .
An r.f coaxial cable generally complying with the requirements of Publication 96- 1 used for the
distribution of television signals (see Sub-clause 3.1 for frequency ranges). The construction of the
outer conductor (or screen) is not restricted to a braided construction, and constructions giving
complete metallic enclosure are in current use.
3. Requirements
Note. - In national specifications, more sfnngent requirements may be prescribed.
--``,,,,,`,``,,,,```,````,,```,-`-`,,`,,`,`,,`---
In addition to the defmitions of Publication 96-1, the following definitions are applicable:
I E C b P T * 3 8 2 m 48448911 00b119b O m
-I
- 6 -
Gamme daffaiblissement
(dB1100 m)
~~
s2,o
2,O 2,5
2,5 3,O
3,O 4,O 4,O 5,O
5,O 6,O
6,O 8,O
8,O 10,O
10,O 13,O
13,O 16,O
16,O 20,O
2
2,5
3
4
5
6
8
10
13
i6
20
Notes I. - Lorsque laffaiblissement dun cble se situe la limite de deux classes, le cble est considr comme tant dans la
Impdance caractristique
. moyenne Z ,
(QI
2 4 inclus
5 8inclus
10 13 inclus
16 20 inclus
1
75
75
75
75
f
f
f
f
2,O
2,5
3;O
5,O
I1 est possible de mesurer laffaiblissement de rflexion des cbles soit en faisant rfrence
75 Q (technique du pont fixe), soit en faisant rfrence limpdance caractristique moyenne
de lchantillon sous essai (technique du pont variable).
Etant donn quelle peut tre utilise sur toute la gamme de frquencesjusqu 960 MHz (voir
paragraphe 3. i), la technique du pont fixe doit tre employe sauf en cas daccord contraire entre le
fabricant et lacheteur.
Des mesures de laffaiblissement de rflexion dans la gamme hautes frquences(HF) entre 3 MHz
et 30 MHz ne sont exiges que dans des cas particuliers aprs accord entre le fabricant et lacheteur.
--``,,,,,`,``,,,,```,````,,```,-`-`,,`,,`,`,,`---
- 7 -
Attenuation data may also be supplied for other frequencies, 30 MHz being preferred for the HF
range and 800 MHz for the UHF range.
Class
designation
Attenuation range
(dB/100 m)
12.0
2.5
2.0 to 2.5
2.5 to 3.0
3.0 to 4.0
4.0 to 5.0
5.0 to 6.0
6.0 to 8.0
8.0 to 10.0
10.0 to 13.0
13.0 to 16.0
16.0 to 20.0
3
4
5
6
8
10
13
16
20
Notes 1. - When the attenuation of a cable fails on the boundary between two classes, the cable is considered to be in the
lower numbered class.
2. - Classes may be grouped together to form larger classes when required, for example Class 3 to 5 withan attenuation
range of 2.5 dB/100 m to 5.0 dB/100 m.
Mean Characteristic
inclusive
75 f 2.0
5 to 8 inclusive
75 2.5
75 f 3.0
1 5 +: 5.0
. 2 to 4
10 to 13 inclusive
16 to 20 inclusive
IEC 96 PT*3 82
Lt844893 0096398 4
- 8 TABLEAU
I
300 460
460 585
585 960
26
23
18
23
20
22
19
21
18
2 4 inclus
5 8 inclus
10 13 inclus
16 20 inclus
Les caractristiques lectriques suivantes divent tre mesures et les rsultats exprims comme
suit:
Caractristique
Capacit linique
(article 12 de la Publication 96-1)
b) Vitesse de propagation relative
(article 13 de la Publication 96-1)
a)
4.2 A prciser
La caractristique lectrique suivante doit tre prcise par le fabricant et exprime comme
suit:
Caractristique
- 9 -
96-3 O I E C 1982
TABLE
I
30 to 300
30010 460
460 to 585
585 to 960
26
23
18
23
20
22
19
21
18
2 to 4 inclusive
5 to 8 inclusive
10 to 13 inclusive
16 to 20 inclusive
*
*
*
*
*
*
4.1 To be measured
The following electrical characteristics are to be measured and the results expressed as indicated:
Characteristic
a) Capacitance per unit length
4.2
Expressed as
To be stated
--``,,,,,`,``,,,,```,````,,```,-`-`,,`,,`,`,,`---
Characteristic
Temperature coefficient of attenuation
Expressed as
The ratio, expressed as a decimal fraction, of the
change in attenuation per Celsius degree to the
attenuation, at a temperature of 20 "C
,
I
78 (1967)
96-1 (1971)
96-IA (1976)
96-2 (1961)
96-2A (1965)
96-2B (1966)
96-2C (1976)
96-3 (1982)
First supplement.
Part 2: Relevant cable specifications.
First supplement.
Second supplement.
Third supplement.
Part 3: General requirements and tests for single-unit coaxial
cables for use in cabled dislribution systems.
153-3 (1964)
153-4 (1973)
153-2 (1974)
153-6 (1967)
153-7 (1972)
154:
154-1 (1964)
154-2 (1980)
154-3 (1982)
154-4 (1969)
154-7(1974)
159 (1964)
169: Radio-freuuencv
- .connecton.
169-1 (1965)
Part 1 :General requirements and measuring methods.
169-2 (1965)
Part 2: coaxid unmatched WMeCtOT.
Amendment No. 1 (1982).
169-3 (1965)
Part 3 :Two-pin connector for twin balanced aerial feeders.
169-4 (1975)
169-5 (1970)
169-6 (1971)
169-7 (1975)
169-8 (1978)
169-9 (1978)
169-11 (1977)
169-12 (1977)
m.
um.
169-13 (1976)
Treizime partie: Connecteurs coaxiaux pour frquences radiolectriques avec diamtre intrieur du conducteur extrieur de
5,6mm (0,22 in)
Impdance caractristique 75 ohms (type
1,6/5,6) Impdancecaractristique 50 ohms (iype 1,8/5,6) avec
des dimensions d'accouplement semblables.
Quatorzime partie: Connecteurs coaxiaux pour frquences radidlectriques avec diamtre intrieur du conducteur extrieur de
12 mm (0,472 in) verrouillage vis Impdance caractristique 75 ohms (type 3,5/12).
Quinzime partie: Connecteurs coaxiaux pour frquences radiolwlriques avec diamtre intrieur du conducteur extrieur de
4.13 mm (0,163 in) verrouillage vis Impdance caractristique 50 ohms (type SMA).
Seizime partie: Connecteurs coaxiaux pour frquences radiolectriques avec diamtre intrieur du conducteur extrieur de
7 mm (0,276 in) verrouillage vis Impdaoce caractristique
50 ohms (75 ohms) (type N).
169-14 (1977)
169-13 (1976)
169-15 (1979)
169-16 (1982)
(Suite au rerso)
169-14 (1977)
169-16 (1982)
169-15 (1979)
'
(Coniinired orerleaJ
--``,,,,,`,``,,,,```,````,,```,-`-`,,`,,`,`,,`---
I E C 96 P T * 3 8 2
q 8 4 4 8 9 1 00b20L O
--``,,,,,`,``,,,,```,````,,```,-`-`,,`,,`,`,,`---
169-17 (1980)
189: Low-frequency cables and wires with P.V.C. insulation and P.V.C. sheath.
189-1 (1965)
Part 1: General test and measuring methods.
Amendment No. 1 (1971).
Amendment No.2 (1972).
189-2 (1981)
Pari 2: Cables in pairs, triples, quads and quintuples for inside
189-3 (1981)
189-4 (1980)
189-5 (1980)
189-6 (1982)
189-7 (1982)
197 (1965)
246 (1967)
261 (1968)
304 (1982)
339 :
installations.
Part 3: Equipment wires with solid or stranded conductor, P.V.C.
insulated, singie.
Part 4: Distribution wires with solid conductors, P.V.C. insulated,
in pairs, triples, quads and quintuples.
Part 5 : Equipment wires and cables with solid or stranded
conductors, P.V.C. insulated, screened, single or one pair.
m.
- General purpose rigid coaxial transmission lines and their associated flange
339-1 (1971)
COMectOrs.
Part 1 : General requirements and measuring methods.
Part 2: Detail s d c a t i o n s .
Guide to the calculation of resistance of plain and coated copper
conductors of low-frequency cables and wires.
374 (1971)
Guide for choosing modular dimensions for waveguide components.
Rigid precision coaxial lines and thek associated precision COMeCtOn.
457:
339-2 (19721
344 (1980) .
457-1 (1974)
457-2 (1974)
457-3 (1980)
Part 3: 14 mm rigid precision coaxial line and associated hermaphroditic precision coaxial connector Characteristic impedances 50 ohms and 75 ohms.
Part 4: 21 mm rigid precision coaxial line and associated hermaphroditic precision coaxial connector. Characteristic impedance 50 ohms (Type 9/21) Characteristic impedance 75 ohms
457-4 (1978)
6/21).
488 (1974)
538 (1976)
538A (1980)
636 (1979)
649 (1979)
673 (1980)
693 (1980)
Dimensions of optical fibres.
708 : Low-frequency cables with polyoleh insulation and moisture barrier polyoleiin
708-1 (1981)
708-2 (1981)
sheath.
Part 1:General design details and requirements.
Part 2: Unit type, filled,moisture bamer polyethylene sheathed
cables with copper conductors and solid or cellular insulation.
708-3(1981)
708-4 (1981)
lation.
Part 4: Unit type, unfued, moisture barrier polyethylene
sheaihed cables with copper conductors, solid insulation and integral suspension strand.
Publication 96-3
PRINTED IN SWITZERLAND
Computer typesefting and printing by Atar S.A., Geneva