PRORAUN DINAMIKI OPTEREENOG TEMELJA KOMPRESORA

Dimenzije temeljnog bloka

AB KONSTRUKCIJA
DEO TEMELJA
G (kN)
tem.ploa
4689.4

Bt=
Lt=
ht=

6.15 m
6.10 m
5.00 m

x(m)
3.075

x*G(kNm)
14419.8

4689.4

teite temelja(m)
OPREMA
OPREMA
S1
S2
S3-1
S3-2

G (kN)
250.0
99.0
35.0
35.0
419.0

z(m)
3.050

y(m)
2.500

y*G(kNm)
11723.4

14419.8

14302.6

11723.4

3.08

3.05

2.50

x(m)
3.129
4.549
1.739
1.739

x*G(kNm)
782.3
450.4
60.9
60.9

1354.3
teite opreme(m)
3.23

419.0 samo oprema, bez bloka.

5108.4
15774.2
zajed. teite tem+opr(m)
3.09
razlika izmeu te. maine i te.temeljne ploe:
=

z*G(kNm)
14302.6

z(m)
3.489
3.489
1.563
1.563

z*G(kNm)
872.3
345.4
54.7
54.7
1327.1
3.17

y(m)
6.000
8.000
5.730
6.970

y*G(kNm)
1500.0
792.0
200.6
244.0
2736.5
6.53

15629.7
3.06

0.16 m
2.56 %

14459.9
2.83

0.12 m
1.92 %

<5%

KARAKTERISTIKE ROTIRAJUIH DELOVA


DEO OPREME
bullgear
rotor1
rotor2
motor rotor

G (kN)
20.8
3.9
1.5
44.0

obrtaji 1/m
1485
16178
18766
1485

PRORAUN TEMELJNE PLOE KOMPRESORA


Prema Richart-u "Vibration of soli and foundation", za pravougaoni oblik temelja:
L=
B=
ro=
ro=
z=
x=
=

6.10 m
6.15 m

L/B=

vmin=
h=
o=
Gmax=
Gmax=
G=

3.457
3.489
1.505
2.235
2.860

Odreivanje dinamikog modula smicanja:


Gtem ploe=
4689 kN
qu=
Z=

0.992
faktori oblika

z=

125.00 kN/m2
31.25 kN/m2
119.45 kN/m2
80.56 kN/m2
93.52 kN/m2
13489.75 PSI
15256.68 PSI
2
90000 kN/m

=
=
=

13.42 PSI
94,023.57 kN/m2
106,339.04 kN/m2

18.00 kN/m3
19

z=
x=
=
=

2.10
1.00
0.50
0.4

K0=

0.674

e=

0.65

Krutosti:
Kz=

2903943.692 kN/m'

5
29.04 *10 kN/m'

Kx=

3449341.79 kN/m'

5
34.49 *10 kN/m'

K=

49093226.73 kN/m'

6
49.09 *10 kN/m'

Relativni stepen priguenja:


z=
2.119
x=
3.522
=
2.461
I=

7036.96

Bz=
Bx=
B=

1.031
1.360
1.669

hbl1=

0.000 m

Lbl=

0.000 m

1.835

relativni koeficijent priguenja


Dz=
0.887
Dx=
0.870
D=
0.029
sopstvena frekvenca sistema
m=
520.73
nz=

74.68 rad/s

fnz=

11.89 Hz

nx=

81.39 rad/s

fnx=

12.95 Hz

n=

83.53 rad/s

fn=

13.29 Hz

frekvence opreme koja rotira:


fbg=
bullgear
fR1=
rotor1

24.75 Hz

bg=

155.51 rad/s

269.63 Hz

R1=

1694.16 rad/s

rotor2

fR2=

312.77 Hz

R2=

1965.17 rad/s

motor rotor

fmr=

24.75 Hz

mr=

155.51 rad/s

odnos prinudne i sopstvene frekvence:


fn/fmr=

1.862

proraun amplituda:
Ckr,z=
Ckr,x=
Ckr,=

77773.37987
84762.74105
319777.3258

neizbalansirane dinamike sile :


deo opreme
motor rotor
bullgear
rotor 1
rotor 2

Fdin (kN)
1.715
1.100
0.770
0.590

C,z=
C,x=
C,=

68983.15
73728.76
9357.71

Fzo=
H=

4.18 kN
6.000 m

u z- pravcu
z=
=
Mz=

2.89E-07 m
2.08
0.201

u x-pravcu
x=
=
Mx=

2.85E-07 m
1.91
0.235

rotacija
=
=
M=

2.07E-07 rad
1.86
0.405

m=

520.73

ukupno pomeranje u vertikalnom i horizontalnom pravcu


Zmax=
9.20E-04 mm
0.000036 in
Xmax=
1.53E-03 mm
0.000060 in
Kontrolna lista:
1. prema DIN ISO 10816-1.1997 maksimalna doputena vibraciona sila svih neizbalansiranih dinamikih sila:
veff=2.80mm/s
vmax=
0.038 mm/s
2. odnos horizontalne amplitude od vibracija i operativne frekvence- fig 3.3 Blake, "New vibration standard for maintenance" pada
na granicu izmeu A i B.
3. magnifikacioni faktor M<1.5 za sve pravce i rotaciju
4. rezonanca
frekvenca maine treba da bude ili f<0.8fm ili f>1.2fm
fm=fn/(sqrt(1-(2D)^2)
fmz,fmx - nije mogua rezonanca (2D)^2>1
fm=

13.32 Hz

fmr=

24.75 >

15.98 Hz

5. horizontalna translacija i rotacija mogu sa se raunaju nespregnuto ako je


sqrt(fnx^2+fn^2)/(fnx*fn)<2/3*f
0.108 <
16.50
6. Kontrola kontanktnog napona u nivou temeljne spojnice
DOP=
250.00 kN/m2
( prema priloenom proraunu doputenih napona iz glavnog projekta )
=
=V/Atem=

0.80
136.17 kN/m2

( korekcioni faktor za doputeni napon obzirom na tip maine )


<
200 kN/m2
(250 x=200 )