c a t a l o g u e
2007 - 2008
4-5
1
6-7
8-9
10-11
12-15
16-17
2
18-19
THERMOBILE production plant, Breda, The Netherlands.
20-21
23
The Thermobile products are produced with great care and they are
extensively tested. A permanent quality control system, according to
ISO 9001:2000, is part of the production process (photo 2-6).
24
Naturally, all Thermobile heaters comply with the most stringent European
certification standards and they carry the well-known markings of CE, GASTEC
and/or CSA/UL and GOST.
25
THERMOBILE INDUSTRIES BV
Siemensring 44 Q
47877 Willich - Germany
Tel. (0)2154 88 99 15, Fax (0)2154 88 99 71
e-mail: info@thermobile.de internet: www.thermobile.de
26-27
THERMOBILE UK LTD
12, Buckingham Close
Bermuda Industrial Estate
Nuneaton, Warwickshire
CV10 7JT, United Kingdom
Phone 02476 35 79 60, Fax 02476 35 79 69
e-mail: info@thermobile.co.uk internet:
www.thermobile.co.uk
28-29
22
30-35
36
Member of
IMA Oil fired with flue connection and separate external burner
PRODRY Dehumidifiers
diesel/heating oil
paraffin
propane
natural gas
electric
used oil
Rapeseed oil
T 80 / TA 80
T 40 / TA 40
T 16 / TA 16
Portable model (wheel set optional)
T 22 / TA 22
Working principle
Safe cool outside housing.
High pressure pump for diesel or paraffin.
APPLICATIONS
AGRICULTURE
HORTICULTURE
TECHNICAL SPECIFICATIONS
(dimensions and weights on back page)
MODEL
PART
NUMBER
HEAT OUTPUT
Btu/hr
kW
kcal/hr
T 16
40.236.000
64.000
18,6
T 22
40.233.000
88.000
25
T 40
40.403.100
160.000
46
T 80
40.803.100
320.000
93
TA 16
40.237.000
64.000
18,6
TA 22
40.223.000
88.000
25
TA 40
40.404.100
160.000
46
TA 80
40.804.100
320.000
93
TAS 16
40.239.000
64.000
18,6
TAS 40
40.407.100
160.000
46
TAS 80
40.807.100
320.000
93
1 kW= 860 Kcal/hr 1 kW=3413 Btu/hr 1 kW=3,6 Mj/hr
SEE PAGE 30-35 FOR ACCESSORIES
16.000
22.000
40.000
80.000
16.000
22.000
40.000
80.000
16.000
40.000
80.000
1 KG/hr=1,2L/hr
APPROX. FUEL
CONS. OIL
L/hr
KG/hr
1,8
2,5
4,5
9,0
1,8
2,5
4,5
9,0
1,8
4,5
9,0
1,5
2,1
3,7
7,5
1,5
2,1
3,7
7,5
1,5
3,7
7,5
HEATED
AIR FLOW
M3/hr
600
600
1.200
2150
600
600
1.200
2.150
600
1200
2150
TANK
CAPACITY
LITRES
16
40
80
160
16
40
80
160
-
POWER
CONSUMPTION
230V (AMPS)
1,1
1,0
2,1
3,6
1,1
0,6
1,8
3,5
1,0
1,8
3,5
THERMOSTAT
CONNECTION
YES
YES
YES
YES
YES
YES
YES
W
NE
ITA 45
ITA 75
ITA 30
For recirculation fans see page 32
Working principle
APPLICATIONS
AGRICULTURE
HORTICULTURE
MOTOR TRADE
MARQUEES HEATING
TECHNICAL SPECIFICATIONS
(dimensions and weights on back page)
MODEL
PART
NUMBER
HEAT OUTPUT
Btu/hr
kW
ITA 30
41.300.000
86.000
ITA 45
41.404.000 167.000
ITA 75
41.750.000 239.000
ITAS 30
41.301.000
86.000
ITAS 45
41.407.000 167.000
ITAS 75
41.751.000 278.000
1 kW= 860 Kcal/hr 1 kW=3413 Btu/hr
kcal/hr
APPROX. FUEL
CONS. OIL
L/hr
KG/hr
24,8
21.000
2,4
2,0
45,1
42.000
4,6
3,8
70,0
60.000
7,7
5,8
24,8
21.000
2,4
2,0
48,4
42.000
4,6
5,8
70,0
70.000
7,7
6,4
1 kW=3,6 Mj/hr 1 KG/hr=1,2L/hr
HEATED
AIR FLOW
M3/hr
MAXIMAL
VENTILATOR
BACK PRESSURE
TANK
POWER
CAPACITY CONSUMPTION
LITRES
230V (AMPS)
OUTLET
CONE
MM
1.100
2.700
3.800
1.100
3.800
3.800
100
200
200
100
200
200
40
80
120
-
300
150
YES
400
150
YES
400
180
YES
300
150
YES
400
150-160
YES
400
180
YES
SEE PAGE 30-35 FOR ACCESSORIES
1,2
3,3
4,0
1,2
3,3
4,0
FLUE
CONNECTION THERMOSTAT
MM
CONNECTION
Tigerloop standard.
IMA 61 Axial
Working principle
High efficiency heat exchanger (92%).
Combustion chamber heat resistant up to 850C.
Radial fan for powerful heat distribution.
Big wheels.
burner
IMA 61 Radial
APPLICATIONS
BUILDING INDUSTRY
INDUSTRY
HORTICULTURE
MOTOR TRADE
Recirculatiionset IMA.
TECHNICAL SPECIFICATIONS
(dimensions and weights on back page)
MODEL
PART
NUMBER
GROSS OUTPUT
Btu/hr
kW
IMA 61 axial
41.722.000 22.5000 65
IMA 61 radial
41.722.300 22.5000 65
IMA 111 axial
41.724.000 38.5000 111
IMA 111 radial
41.724.207 38.5000 111
IMA 111 radial HP
41.724.210 38.5000 111
IMA 185 axial
41.728.200 64.1000 185
IMA 185 radial HP
41.728.010 64.1000 185
IMA 185 radiaal 230V 41.728.650 64.1000 185
1 kW= 860 Kcal/hr 1 kW=3413 Btu/hr 1 kW=3,6 Mj/hr
kcal/hr
APPROX. FUEL
CONS. OIL
L/hr
KG/hr
56.000
6,5
56.000
6,5
96.000
10,9
96.000
10,9
96.000
10,9
160.000
18,4
160.000
18,4
16.0000
18,4
1 KG/hr=1,2L/hr
5,4
5,4
9,1
9,1
9,1
15,3
15,3
15,3
HEATED
AIR FLOW
M3/hr
3.100
4.500
6.400
8.000
11.500
9.700
15.000
10.000
MAX. BACK
PRESSURE OF FAN
Pa
150
250
150
300
500
150
500
300
POWER
CONSUMPTION
(AMPS)
2,8/230V
6,1/230V
4,1/230V
9,2/230V
7,7/400V
7,2/230V
10,4/400V
14/230V
OUTLET
CONE
MM
FLUE
CONNECTION
MM
THERMOSTAT
CONNECTION
400
180
YES
400
180
YES
500
200
YES
500
200
YES
500
200
YES
600
200
YES
600
200
YES
600
200
YES
SEE PAGE 30-35 FOR ACCESSORIES
IMAC 4000 E
IMAC 2000 E
IMAC 2000S
Working principle
High efficiency heat exchanger (92%).
Weather resistant and lockable casing.
High Pressure fan for powerful heat distribution.
Recirculation hose flange possible.
10
High capacity.
FEATURES
APPLICATIONS
BUILDING INDUSTRY
TECHNICAL SPECIFICATIONS
(dimensions and weights on back page)
MODEL
PART
NUMBER
GROSS OUTPUT
Btu/hr
kW
kcal/hr
APPROX. FUEL
CONS. OIL
L/hr
KG/hr
185
160.000
18,4
15,3
185
160.000
18,4
15,3
383
333.000
38,0
31,5
1 kW=3,6 Mj/hr 1 KG/hr=1,2L/hr
HEATED
AIR FLOW
M3/hr
MAX. BACK
PRESSURE OF
FAN Pa
POWER
CONSUMPTION
400V (AMPS)
OUTLET
CONE
MM
15.000
12.000
24.000
500
500
600-1000
10,4
9,0
20,0
300/500/600
300/500/600
500/600
FLUE
CONNECTION
MM
THERMOSTAT
CONNECTION
YES
200
200
YES
250
YES
SEE PAGE 30-35 FOR ACCESSORIES
11
G 45 E
G 30 E
G 15 E
Adjustable capacity.
12
APPLICATIONS
BUILDING INDUSTRY
MODEL
G 15 E
G 30 E
G 45 E
PART
NUMBER
40.015.000
40.030.000
40.045.000
Btu/hr
51.250
42.400
89.500
1 kW=3413 Btu/hr
HEAT OUTPUT
MIN.
MAX.
kW kcal/hr
Btu/hr kW
15,0 12.900
51.250 15,0
12,4 10.650 106.600 31,2
26,2 22.500 148.600 43,5
1 kW=3,6 Mj/hr
1 KG/hr=1,2L/hr
kcal/hr
12.900
26.800
37.400
APPROX. FUEL
CONS. GAS KG/hr
MIN.
MAX.
1,17
1,17
0,98
2,46
2,10
3,43
HEATED
AIR FLOW
M3/hr
300
750
850
POWER
CONSUMPTION
230V (AMPS)
0,3
0,45
0,45
GAS
(ON HEATER)
BAR
0,7
1,5
2,0
THERMOSTAT
CONNECTION
-
GA 110 E
(wheel set standard)
GA 60 E/GA 85 E
(wheel set optional)
GA 42 E
GA 25 E
FEATURES
APPLICATIONS
AGRICULTURE
13
BUILDING INDUSTRY
MODEL
PART
NUMBER
Btu/hr
HEAT OUTPUT
MIN.
MAX.
kW kcal/hr
Btu/hr kW
GA 25 E
43.030.000
51.000 15 12.900
GA 42 E
40.277.000
89.000 26 22.360
GA 60 E*
40.707.005
130.000 38 32.680
GA 85 E*
40.707.002
198.000 58 49.880
GA 110 E
40.710.005
266.000 78 67.000
*) Standard without wheels, for wheel set see accessories.
kcal/hr
APPROX. FUEL
CONS. GAS KG/hr
MIN.
MAX.
85.300 25 21.500
0,9
152.000 44 38.000
1,0
220.000 64 55.000
1,9
320.000 93 80.000
2,8
448.000 130 112.000
3,9
1 kW= 860 Kcal/hr 1 kW=3413 Btu/hr
HEATED
AIR FLOW
M3/hr
POWER
CONSUMPTION
230V (AMPS)
1,8
800
0,30
3,1
760
0,52
4,6
2.400
0,64
6,7
2.400
0,64
9,3
4.000
2,20
1 kW=3,6 Mj/hr 1 KG/hr=1,2L/hr
GAS PRESSURE
(ON HEATER)
BAR
THERMOSTAT
CONNECTION
0,5-1,5
YES
0,4-1,5
YES
0,4-2,0
YES
0,4-2,0
YES
0,4-2,0
YES
SEE PAGE 30-35 FOR ACCESSORIES
GA 110 EV
MS 60
GA 60 EV/GA 85 EV
Working principle
MODULATING CONTROL UNITS MS 20, MS 40 AND MS 60
With the MS 60, a drying plant operating to a maximum of 60
kg of propane gas per hour, 20 kg for the MS 20 and 40 kg for
the MS 40, can be controlled in which several heaters (also all
Full humidity and dust
horizontal models) can be connected. The modulating control
proof control panel.
unit ensures that the heat capacity is automatically and constantly adapted to the requirement at any moment. This is a
Clean burner because of fresh
continuous process. The drying of
air connection.
products at highly fluctuating outside temperatures can thus
be improved considerably.
Removable exterior cover for
service.
14
Fire protection
system for crop drying.
FEATURES
MS 20:
MS 60:
AGRICULTURE
TECHNICAL SPECIFICATIONS
MODEL
GA 42 E*
GA 60 EV*
GA 85 EV*
GA 110 EV*
PART
NUMBER
40.277.000
40.707.005
40.707.002
40.710.005
Btu/hr
89.000
130.000
198.000
266.000
1 kW=3413 Btu/hr
HEAT OUTPUT
MIN.
MAX.
kW kcal/hr
Btu/hr kW kcal/hr
26 22.360 152.000 44 38.000
38 32.680 220.000 64 55.000
58 49.880 320.000 93 80.000
78 67.080 448.000 130 112.000
1 kW=3,6 Mj/hr
APPROX. FUEL
CONS. GAS KG/hr
MIN.
MAX.
1,0
3,1
1,9
4,6
2,8
6,7
3,9
9,3
HEATED
AIR FLOW
M3/hr
760
2400
2400
4000
1 KG/hr=1,2L/hr
POWER
CONSUMPTION
230V (AMPS)
0,52
0,64
0,64
2,20
GAS
CONNECTION
INCH
1/2
1/2
1/2
1/2
GAS PRESSURE
(ON HEATER)
BAR
0,4-1,5
0,4-2,0
0,4-2,0
0,4-2,0
ANCILLARIES
Modulating control unit MS 20 (1-20 kg propane), adjusting range 0,4-2,0 bar, connection 1/4" IN-3/8" OUT, supply 230V
Modulating control unit MS 20 (1-40 kg propane), adjusting range 0,4-2,0 bar, connection 1/4" IN-3/8" OUT, supply 230V
Modulating control unit MS 60 (1-60 kg propane), adjusting range 0,4-2,0 bar, connection 1/4" IN-3/8" OUT, supply 230V3-point control with manual operation
Connection accessory for external computer (instead of complete MS):
Modulating control unit MS 60, connection 1/2"
Modulating control unit MS 60,supply 230 VAC 50/60Hz, 3-point control with manual operation
Modulating control unit MS 60,supply 230 VAC 50/60Hz, 3-point control , pot.meter 5K-Ohm for feedback
Modulating control unit MS 60,supply 24 VAC 50/60Hz, control 0-10, Vdc analog
Modulating control unit MS 60,supply 24 VAC 50/60Hz, 3-point control , pot.meter 1K-Ohm for feedback
Modulating control unit MS 60,supply 24 VAC 50/60Hz, 3-point control
Modulating control unit MS 40,adjusting range 0,4-2,0 bar, connection 1/2"
Modulating control unit MS 40,supply 230 VAC 50/60Hz, 3-point control
Modulating control unit MS 40,supply 24 VAC 50/60Hz, 3-point control for feedback
Modulating control unit MS 20, adjusting range 0,4-2,0 bar, connection 1/4" IN-3/8" OUT
Modulating control unit MS 20,supply 230 VAC 50/60Hz, 3-point control
Modulating control unit MS 20,supply 24 VAC 50/60Hz, control 0-10, Vdc analog
Modulating control unit MS 20,supply 24 VAC 50/60Hz, control 0-10, 3-point control
Modulating control unit MS 20,supply 24 VAC 50/60Hz, 3-point control with pot.meter
Temperature probe PT 100 with 10m cable
Temperature probe PTC 100 with 10m cable
Fire protection system for crop drying (propane gas), supply 230 V
Magnetic gas valve for propane gas, 230V, to place in gas supply pipe
Magnetic gas valve for propane gas, 24V, to place in gas supply pipe
Room/Maximum thermostat 0/60 degrees C
Suspension bracket GA 60/85/110 E
Suspension bracket GA 60/85/110 E
THERMOSTAT
CONNECTION
YES
YES
YES
YES
PART NUMBER
40.301.018
40.301.069
40.301.019
40.301.029
40.301.055
40.301.056
40.301.052
40.301.054
40.301.066
40.301.067
40.301.058
40.301.064
40.301.065
40.301.075
40.301.033
40.301.063
40.301.045
40.301.047
40.301.080
40.301.049
40.277.033
40.301.007
15
AGA 111 E
AGA 75 E
AGA 45 E
Working principle
Working principle
16
Easy access for cleaning. Clean burner because of fresh air connection.
FEATURES
humidity and dust proof control panel containing all electronic components.
Full
AGA
45 E/75 E/111 E, suitable for propane and natural gas.
With fresh
intake to the burner.
Burner withairelectronic
ignition, ionisation protection and thermostat connection.
Room ventilation is required,
CE-GASTEC-GOST approved.even for models with separate fresh air intake to the burner.
AGA 100 series available in 3 models:
(all models can be used horizontally and vertically, blowing either upwards or downwards)
AGA 100 E: fit for external air suction system.
AGA 102 E: Standard with an external air suction system and modulating burner.
Please note: For AGA models the following pressure at the heater is required:
AGA 100 : minimum 25 millibar, maximum 100 millibar
AGA 102 : minimum 25 millibar, maximum 50 millibar
If the gas supply pressure is higher than the maximum a pressure regulator is required
(accessory).
AGA 45 E/ 75 E/ 111 E:: with external air suction system and wall connector, suitable for propane and natural gas.
Please note: Before ordering please specify gas type.
When using propane gas a pre-pressure regulator is required.
APPLICATIONS
LIVESTOCK
17
TECHNICAL SPECIFICATIONS
MODEL
PART
NUMBER
AGA 45 E
AGA 75 E
AGA 100 E
AGA 102 E
40.745.200
40.775.200
40.720.070
40.722.100
AGA 111 E
40.731.050
Btu/hr
136.000
190.000
-
MIN.
kW
40
56
-
146.000
257.000
360.000
360.000
448.000
360.000
kW
45
75
105
105
130
105
kcal/hr
38.500
64.000
90.000
90.000
112.000
90.000
APPROX. FUEL
CONS. GAS M3/hr
MIN.
MAX.
HEATED
AIR FLOW
M3/hr
POWER
CONSUMPTION
230V (AMPS)
GAS
CONNECTION
INCH
THERMOSTAT
CONNECTION
4,3
4,81 / 3,22
7,81 / 5,42
11,2
11,2
2.500
4.500
7.000
7.000
1,0
1,9
4,8
5,5
1/2
1/2
3/4
3/4
YES
YES
YES
YES
11,21 / 7,52
7.000
5,3
3/4
YES
1 kW=3413 Btu/hr
1 kW=3,6 Mj/hr
1 KG/hr=1,2L/hr
ANCILLARIES
PART NUMBER
40.722.018
40.722.019
40.720.063
40.301.049
40.745.098
TAS 800 E
Working principle
18
19
APPLICATIONS
LIVESTOCK
TECHNICAL SPECIFICATIONS
(dimensions and weights on back page)
MODEL
PART
NUMBER
TAS 800 E*
40.467.000
*E = Stainless steel bodywork
81.700
1 kW=3413 Btu/hr
APPROX.
FUEL CONS. OIL
L/hr
KG/hr
HEATED
AIR FLOW
M3/hr
9,5
7,9
7.000
1 kW=3,6 Mj/hr 1 KG/hr=1,2L/hr
POWER
CONSUMPTION
230V (AMPS)
4,6
THERMOSTAT
CONNECTION
YES
SEE PAGE 30-35 FOR ACCESSORIES
AT 400/500(C)
AT 500
AT 307
Clean heat.
100%
Fixed
outlet
temperature circa 50 70C.
Closed combustion
chamber.
Built-in fuel tank.
Separate combustion air intake fan which
can be connected to outside supply.
AT 307
AT 306
AT 306
Clean heat.
100%
Fixed
outlet
circa 50 70C.
Radiation heattemperature
on three sides.
20
AT 400
Clean heat.
100%
Fixed
outlet
circa 50 70C.
Radiation heattemperature
three sides. on
THERMO:
Fan assisted air
distribution
(Accessory for AT 306).
Perforated combustion chamber (not
suitable near explosive vapours).
To control chimney draught and facilitate drainage of condensate water, a T-piece with draught stabiliser and condensate trap is
an essential basis of the flue stack installation. Available separately or as a part of the standard flue kit (U.K. market).
FEATURES AT MODELS
and safe housing with powder coating.
Durable
Internal
vapourising
Flame failure securityburner.
High/low manual heatthermostat.
regulation.
ignition system.
Manual
Overheat
thermostat.
Oil overflowsecurity
security
system.
in fuel tank
APPLICATIONS
AGRICULTURE
Heating workshops.
21
INDUSTRY
MODEL
PART
NIUMBERS
THERMO
AT 306
AT 307
AT 400
AT 500
AT 400 C*
AT 500 C*
41.904.104
41.905.000
41.906.000
41.921.000
41.911.000
41.921.100
41.911.100
66.000
66.000
82.000
125.000
82.000
125.000
19
19
24
36
24
36
16.500 100.000
16.500 100.000
20.500 140.000
31.250 200.000
20.500 140.000
31.250 200.000
29
29
41
59
41
59
25.000
25.000
35.000
50.000
35.000
50.000
1 kW=3413 Btu/hr
HEATED
AIR FLOW
M3/hr
2,0
2,0
2,5
3,8
2,5
3,8
1.000
1.000
3.000
3.000
3.600
3.800
3,0
3,0
4,3
6,2
4,3
6,2
1 kW=3,6 Mj/hr
1,7
1,7
2,1
3,2
2,1
3,2
2,5
2,5
3,6
5,2
3,6
5,2
1 KG/hr=1,2L/hr
TANK
CAPACITY
LITRES
50
50
55
55
55
55
POWER
CONSUMPTION
230V (AMPS)
FLUE
CONNECTION
MM
THERMOSTAT
CONNECTION
0,57
0,23
0,80
1,00
2,00
3,90
4,30
130
130
130
180
130
180
ANCILLARIES
PART NUMBER
41.900.680
41.910.002
41.900.521
41.910.145
41.910.300
BioEnergy 1
BioEnergy 2
FEATURES
in tank.
Built
BioEnergy
radial fan, Bio Energy 2 has axial fan
Type of fuel:1 has
rapeseed
flax oil.
Bio Energy 2 has a builtoilinorheat
exchanger for high performance.
Odourless burning.
High/low capacity control.
Capacities of 29 and 41 kW.
APPLICATIONS
AGRICULTURE:
TECHNICAL SPECIFICATIONS
CAPACITY
MIN
MAX
kW Kcal/hr
Btu/hr kW Kcal/hr
MODEL
PART
NUMBER
BioEnergy 1
BioEnergy 2
1 kW= 860 Kcal/hr
41.906.150
66.000 19 16.500 100.000 29 25.000
41.921.150
82.000 24 20.500 140.000 41 35.000
1 kW=3413 Btu/hr 1 kW=3,6 Mj/hr 1 KG/hr=1,2L/hr
Btu/hr
FUEL
CONSUMPTION KG/H
MIN. MAX.
AIR
DISPLACEMENT
M3/H
FUEL
TANK/LTR
2,0
2,5
1.000
3.000
50
55
3,0
4,3
POWER
CONSUMPTION
AMPERAGE 230V
FLUE
CONNECTION
IN MM
0,80
130
1,00
130
SEE PAGE 30-35 FOR ACCESSORIES
PROHEAT 40
PROHEAT 60
PROHEAT 80
Low-noise radial fan. Large air volumes guarantee quick heating. Standard equipped with thermostat.
FEATURES
APPLICATIONS
AUTOMOTIVE: Heating of garage workshops.
AGRICULTURE: Heating of workshops.
INDUSTRY: Heating and frost protection of halls, transit sheds and warehouses.
TECHNICAL SPECIFICATIONS
MODEL
PROHEAT 40
PROHEAT 60
PROHEAT 80
PART
NUMBER
APPROX. FUEL
CONS. OIL
L/hr
KG/hr
40.294.000
145.200
42
36.300
4,7
40.296.000
221.600
64
55.400
7,2
40.298.000
290.850
84
72.100
9,5
1 kW= 860 Kcal/hr 1 kW=3413 Btu/hr 1 kW=3,6 Mj/hr 1 KG/hr=1,2L/hr
4,0
6,0
8,0
HEATED
AIR FLOW
M3/hr
CAPACITY
FUEL TANK
LTR
2.800
4.500
5.300
55
75
105
POWER
CONSUMPTION
230V (AMPS)
2,6
6,7
8,0
FLUE
CONNECTION
MM
THERMOSTAT
CONNECTION
120
150
180
BUILT-IN
BUILT-IN
BUILT-IN
23
COOLSPACE 1
COOLSPACE 2
Outlet panel
24
FEATURES
cooling capacity.
High
low maintenance.
Very
hose connection.
Optional
used as the cooling agent.
Water
Fits through doors.
APPLICATIONS
cooling garage workshops and warehouses, dry cleaners, marquees.
TECHNICAL SPECIFICATIONS
MODEL
PARTNUMBER
POWER SUPPLY
VOLT
HERZ
MOTOR AMP
MAX
AIR DISPLACEMENT
M3/H
PUMP
AMP.
FAN
WATT
COOLSPACE 1
COOLSPACE 2
55.016.000
55.036.000
220
220
3,4
6,3
0-3.600
0-16.500
0,85
0,75
250
375
50
50
SPECIAL ACCESSORIES
PARTNUMBER
55.016.001
55.016.002
55.036.020
PRODRY Dehumidifiers
PRODry 35
PRODry 55
PRODry 80
Pro Dry 35/55 equipped with condensate collection tank with overflow prevention
and connection for fixed drainage (ProDry 80 standard).
Quick dehumidification of the air.
FEATURES
process.
Low-noise compressor and fan.
Simple operation.
Equipped with hour counter (hygrostat optional).
APPLICATIONS
MODEL
PRODRY 35
PRODRY 55
PRODRY 80
Hose
PART
NUMBER
CAPACITY
LTR/24 hr
MAX.
50.500.350
30
50.500.550
55
50.500.800
80
00.003.207 a metre
OPERATING
RANGE
% RH
C
AIR
FLOW
M3/hr
POWER
CONSUMPTION
230V (AMPS)
TANK
CAPACITY
LTR
17,2
34,5
48,0
35-100
35-100
35-100
350
600
850
3,3
3,5
4,8
6
6
-
26,8
53,0
80,0
2-32
2-32
2-32
25
ProHeat 18
CH 18
CH 12
CH 3
BX 15
BX 9
BX 3
VTB 15000
VTB 9000
VTB 3000
Comfortable heat Suitable for open areas Can be used instantly where power is available
Working principle
26
ELEKTROHEATER ProHeat 18
thermostat.
Built-in
Stainless steel elements.
100%
Clean and dry heat.
Fixed outlet
circa 30 60C
(2 steps on BXtemperature
9).
switch for continuous frost
Selector
protection with ventilation or space hea-
thermostat.
Built-in
steel elements.
Stainless
Radial fan for larger heat throw.
100%
Clean and dry heat.
Fixed outlet
temperature circa 40 120C.
Space and spot
heating.
Higher outlet temperature.
thermostat.
Built-in
steel elements.
Stainless
Radial fan for larger heat throw.
100%
and dry heat.
Radial Clean
for extra heat throw (VTB).
Axial fanfan(CH)
Fixed outlet temperature circa 40 100C.
Space and spot heating.
Higher outlet temperature.
ting.
FEATURES
frame suitable for suspension
Combined
as well as carrying .
Stackable
27
APPLICATIONS
AGRICULTURE
HORTICULTURE
INDUSTRY
BUILDING INDUSTRY
TECHNICAL SPECIFICATIONS
(dimensions and weights on back page) SEE PAGE 30-35 FOR ACCESSORIES
MODEL
ProHeat 183)
BX 3 1)
BX 9 2)
BX 15 3)
VTB 3000 1)*
PART
NUMBER
40.018.000
40.107.005
40.107.015
40.107.020
40.107.030
VTB 3000 TUK**1) 40.107.032
VTB 9000 2)
40.107.035
VTB 15000 3)
40.107.025
CH 3
40.107.091
CH 12
40.107.092
CH 18
40.107.093
HEAT OUTPUT
Btu/hr
kW kcal/hr
61.500
10.250
30.750
51.000
10.250
9.560
30.750
51.000
10.250
41.000
61.500
18
3
9
15
3
2,8
9
15
3
12
18
15.480
2.580
7.740
12.900
2.580
2.408
7.740
12.900
2.580
10.320
15.480
VOLTAGE
3x400
1x230
3x400
3x400
1x230
1x240
3x400
3x400
1x230
3x400
3x400
700
-
1.000
220
900
1.000
225
225
550
1.000
250
600
1.500
ADJUSTMENT
RANGE
kW
0-9-18
0-2-3
0-4,5-9
0-7,5-15
0-3
0-2,8
0-4,5-9
0-6-9-15
0-3
0-6-9-12
0-9-13,5-18
DELTA T
C
120
38
36/28
42
60
55
100
38/60/100
60
100
90
POWER
CONSUMPTION
(AMPS)
13/26,0-400V
8,9/13,2-230V
6,8/13,3-400V
11,1/21,9-400V
13,0-230V
12,0-240V
11,5/13,0-400V
8,0/14,0/23,0-400V
13-230V
18-400V
26-400V
OUTLET
CONE
MM
98
98
120
150
160
300
300
THERMOSTAT
CONNECTION
BUILT-IN.
BUILT-IN.
BUILT-IN.
BUILT-IN.
BUILT-IN.
BUILT-IN
BUILT-IN.
BUILT-IN.
-
VAL 6 KB
VAL MIDI
VAL DAYSTAR
Working principle
45 Vertical inclination infra-red heat screen.
28
29
APPLICATIONS
AGRICULTURE
HORTICULTURE
INDUSTRY
BUILDING INDUSTRY
TECHNICAL SPECIFICATIONS
(dimensions and weights on back page)
MODEL
PART
NUMBER
HEAT OUTPUT
MAX.
Btu/hr
kW
kcal/hr
40.106.000
40.106.200
40.106.100
40.106.050
40.106.030
140.000
140.000
140.000
112.000
52.500
1 kW=3413 Btu/hr
40
40
40
33
15
1 kW=3,6 Mj/hr
35.000
35.000
35.000
28.000
13.000
1 KG/hr=1,2L/hr
3,2
3,2
3,2
2,3
1,3
TANK
CAPACITY
LITRES
POWER
CONSUMPTION
230V (AMPS)
40
40
60
38
10
0,25
0,25
0,25
0,25
0,5
SEE PAGE 30-35 FOR ACCESSORIES
THERMOBILE ACCESSORIES
THERMOSTATS
RT 1
RT 2
RT 4
IT 1
DA 1
SPECIFICATIONS
RT1, room thermostat 0/37C with 5 m cable and plug, IP 54
Switching differential 2 degrees.
SUITED FOR
TA, TAS, ITA, ITAS, IMA,
IMAC, GA, AGA
PART NUMBER
40.228.110
RT 2, as RT 1, with 10 m cable, IP 54
40.228.120
40.228.100
40.000.107
41.729.220
40.202.140
SWITCHING / ELECTRONICS
30
IMA 111/185
IMAC 2000 E
IMA 111/185
IMAC 2000 E
IMA 61/111/185
IMA 61/111/185
T/TA 40, ITA 30/45
T/TA 80, ITA 75
TRANSPORT AND STORAGE
Set of air
wheels
T/TA 16
T/TA 16
T/TA 22
T/TA 22
IMA 61/111/185
T/TA 40/80,ITA 40/65
ITA 30
ITA 45
ITA 75
GA 60/85E
GA 110E
G/GA 30
IMA 61
IMA 111/185
41.728.190
41.729.250
41.728.203
41.729.094
41.728.235
41.728.180
40.402 090
40.802.150
Fork truck
slots IMA
40.236.015
40.237.023
40.223.168
40.223.195
41.722.237
40.404.220
41.300.053
40.404.300
40.404.400
40.707.094
40.710.124
40.291.020
41.722.219
41.728.115
THERMOBILE ACCESSORIES
WARM AIR TRANSPORT AND ANCILLARIES
OUTLET OPENINGS
2x300 mm
SUITED FOR
ITA 45/75
PART NUMBER
41.404.153
OUTLET OPENINGS
2x300 mm
2x365 mm
4x300 mm
2x450 mm
4x300 mm
3x365 mm
2x450 mm
2x500 mm
OUTLET OPENINGS
3-6x300 mm
2x500 mm
2x500 mm
4x300 mm
SPECIFICATIONS
Connection piece 300 mm
Connection piece 400 mm, incl.2
quick release clamps
Connection piece . 365
Reducing piece 400- 365 mm
SUITED FOR
IMA 61
IMA 111
IMA 111
IMA 111
IMA 185
IMA 185
IMA 185
IMA 185
SUITED FOR
IMAC 2000 E
IMAC 2000 E
IMAC 2000 S
IMAC 2000 S
SUITED FOR
Hose ITA 30
PART NUMBER
41.722.068
41.724.192
41.724.177
41.724.115
41.728.177
41.728.197
41.728.439
41.728.068
PART NUMBER
41.729.168
41.729.188
41.729.187
41.729.820
PART NUMBER
99.084.041
41.404.152
99.084.023
41.651.128
31
Rubber quick
release clamps
IN MM
150
300
365
100
120
300
365
400
400
500
600
Y-piece
T-piece
SUITED FOR
VTB 15000
ITA 30, distribution head ITA 45/75
ITA 40/65
VTB 3000
VTB 9000
distribution head IMA 61/111/185, IMAC 2000 E
distribution head IMA 111/185
ITA 45/75
IMA 61
IMA 111, distribution head IMA 185
IMA 185, IMAC 2000 E /2000 S /4000 E
PART NUMBER
40.107.071
40.107.077
40.107.078
40.107.270
40.107.275
40.107.276
40.107.278
40.107.079
40.107.280
40.107.282
40.107.284
ATTENTION: Hoses produce BACK PRESSURE which can cause the heater to switch off. Avoid too LONG and/or too NARROW hoses and too many BENDS.
Heaters with RADIAL fans are especially suited.
THERMOBILE ACCESSORIES
CONNECTION PIECES FOR HOSES WITH SLEEVE
To connect hoses. Including hose clips.
SPECIFICATIONS
Connection piece 300 mm
Connection piece 365 mm
Connection piece 400 mm
PART NUMBER
41.218.071
41.728.205
41.404.154
PART NUMBER
40.502.067
40.502.068
40.502.069
40.502.071
40.502.073
PART NUMBER
40.509.158
40.502.251
41.215.073
41.522.195
41.522.196
PART NUMBER
41.400.003
41.200.051
41.400.002
41.404.117
PART NUMBER
41.729.215
41.724.240
41.729.225
41.724.245
41.729.229
RECIRCULATION
32
Recirculation hoses
RECIRCULATION HOSES
With steel spiral to prevent
compression.
RECIRCULATION FLANGES
To be used in combination with
supplied closed panel, to be
fixed instead of standard
suction panel.
Recirculation flange and hose
RECIRCULATIONSET
Recirculation flanges
IMAC 2000 E
LENGTH IN M
10
5
10
FOR HOSE DIAMETER
Recirculationset IMA
IN MM
300
600
600
SUITED FOR
IMAC 2000 E
IMAC 2000 E/2000 S E/4000 E
IMAC 2000 E/2000 S E/4000 E
SUITED FOR
PART NUMBER
41.729.240
41.729.241
41.729.242
PART NUMBER
3x300 mm
IMAC 2000E
41.729.201
1x600 mm
1x 600mm
IMAC 2000E
IMAC 2000S
41.729.065
41.729.878
IMA 61
IMA 111
IMA 185
41.722.120
41.724.008
41.728.008
400
400
500
THERMOBILE ACCESSORIES
RECIRCULATION FANS
Provide, in combination with heaters, extra ventilation and a better distribution of warm air.
TBE models for HORTICULTURE
Especially suited for serial ventilation, parallel
ventilation and recirculation systems.
FEATURES
Suited for suspension.
Easily stackable.
Shock proof synthetic fan housing.
Double-sided grill according to CE-standard.
Isolation class F, IP 55.
OPTIONS
3-Step control regulator on rear of motor. (50.500.207)
Plug and 4 m cable.
60 Hz motors.
3-Phase motors.
MODEL
TB4E/40Q
TB4E/50Q
TB6E/40Q
TB6E/50Q
POWER
W
230
390
180
300
IN
MM
420
518
420
518
TTV 4500
TTV 7000
230
390
420
518
RPM
1400
1400
900
900
AIR
FLOW
M3/hr
5050
7760
3950
7060
POWER
CONSUMPTION
(AMPS) 230V/50Hz
1,1
1,8
1,1
1,4
AIR THROW
IN M
47
58
36
53
NOISE LEVEL
dB (A)
50
55
47
51
PART NUMBER
50.500.201
50.500.202
50.500.203
50.500.204
1400
1400
4500
7000
1,1
1,8
45
55
60
64
50.500.210
50.500.220
OPTIONS
Hose connection piece 450 mm
Hose connection piece 550 mm
Hose 550 mm, L=7,6 m
Hose 450 mm, L=7,6 m
SUITED FOR
TTV 4500
TTV 7000
TTV 7000
TTV 4500
PART NUMBER
50.500.211
50.500.221
50.500.222
50.500.212
33
Wall connector
TYPE OF BURNER
Oil burner SLW 22
Oil burner SLW 44/SLW 55
SUCTION DIAMETER
150 mm
150 mm
SUITED FOR
IMA 61
IMA 111/185, IMAC 2000 E
PART NUMBER
99.095.025
99.095.026
SUITED FOR
AGA 45/75/102/111 E,
GA 60/85/110,TAS 800 E
IMA
PART NUMBER
LENGTH IN M
IN MM
5
1
102
150
CONNECTION DIAMETER
100 mm
41.000.585
00.003.283
SUITED FOR
PART NUMBER
Suction hoses GA 60/85/110 E, 40.721.016
AGA 45/75/102/111 E, TAS 800 E
THERMOBILE ACCESSORIES
FUEL SUPPLY
Conversion kit
Connection/reduction set
SPECIFICATIONS
Conversion kit from 1-way to 2-way pipe system, for suction from bulk tank, maximum
length 50 m/height 3 m (depends on diameter of pipe).To be mounted on fuel pump.
SUITED FOR
T, TA, ITA
PART NUMBER
41.402.114
Oil supply unit 40 litres to transport oil under pressure from bulk tank to
1 or more heaters, to maximum height of 30 m.
41.522.211
41.522.212
41.522.213
41.522.214
VAL-6
44.119.000
SPECIFICATIONS
Oil preheating with cable.
Oil preheating with cable.
SUITED FOR
Burner SLW 22
Burner SLW 44/55
PART NUMBER
41.527.212
41.527.211
Oil filter with water separation and bracket for return pipe.
IMA
41.722.230
TAS 800 E
40.467.052
34
Multitanks
SPECIFICATIONS
SUITED FOR
PART NUMBER
99.999.700
99.999.701
99.999.703
99.999.720
G, GA
40.700.054
THERMOBILE ACCESSORIES
FLUE STACKS*
Pipes
DESCRIPTION
Galvanised pipes*.
Rain caps
LENGTH IN M
1
1
1
IN MM
150
180
200
300
SUITED FOR
ITA, ProHeat 60
ITA 75, IMA 61, ProHeat 80
IMA 111/185, IMAC 2000 E/S
IMAC 4000 E
PART NUMBER
41.000.562
41.522.172
41.528.192
41.740.665
150
180
200
300
ITA, ProHeat 60
ITA 75, IMA 61, ProHeat 80
IMA 111/185, IMAC 2000 E/S
IMAC 4000 E
41.000.565
41.522.175
41.528.187
41.740.666
150
180
200
300
ITA, ProHeat 60
ITA 75, IMA 61, ProHeat 80
IMA 111/185, IMAC 2000 E/S
IMAC 4000 E
41.000.561
41.522.171
41.528.230
41.740.667
150
180
200
120-130
ITA 40/45/65
ITA 75
IMA 111/185, IMAC 2000 E/S
ProHeat 40
41.652.250
41.750.250
41.528.181
41.000.550
Reducer
* Stainless steel systems available for U.K. market.
SPECIFICATIONS
CO2 measuring set
Pressure gauge 0-25 bar 1/8" BSP
Pressure gauge 0-25 bar 1/4" BSP, glycerol filled
Pressure gauge set (with overpressure protection)
Pressure gauge 0-0,6 bar
Soot pump complete with paper and lubricant
Testing paper for soot pump
Filling liquid for CO2 meter
Intertest for oil heaters with SATRONIC burner relays
Testing unit for SATRONIC oil burner relays
Testing unit for SATRONIC gas burner relays
Smokegas thermometer
Chimney gas thermometer, Brigan
Spray can with paint, colour red, content 400 ml
Spray can with paint, colour light grey, content 400 ml
Spray can with paint, colour anthracite, content 400 ml
PART NUMBER
40.000.360
40.000.185
40.000.332 / 40.000.349
40.000.331
40.225.146
40.000.190
40.000.189
40.000.191
40.223.102
40.223.101
40.000.330
40.000.192
40.000.355
60.530.075
60.530.076
60.530.077
HEATER ONLY
DIMENSIONS IN CM
B
C
D
82
119
131
169
82
-
33
46
55
63
33
-
45
73
80
90
30
-
24
31
48
69
18
30
44
75
86
110
108
129
86
108
126
154
33
50
54
67
33
57
39
74
45
60
81
94
45
56
55
101
26
34
62
85
20
42
60
90
50
69
80
27
48
105
125
163
216
120
-
49
62
65
39
-
69
90
98
46
53
71
58
105
131
50
80
120
129
173
186
129
173
186
52
68
69
52
68
69
85
105
117
62
75
90
76
130
158
66
120
135
66
72
82
-
100
100
117
-
151(199)
174(223)
212(271)
300
240
385
71
78
91
81
80
120
128
134
152
136
137
188
190(220)
220(270)
305(500)
600
545
*
202
75
180(240) 80(100)
240(300) 103(104)
300
81
240
80
385
120
142(170)
142(172)
173(172)
136
137
188
220(250)
330(530)
425(625)
600
545
*
49
53
69
55
58
100
100
119
119
18
28
28
28
40
46
46
53
53
27
40
40
50
44
41
41
63
63
40
45
65
13
109
109
119
119
106
110
138
138
138
60
-
40
53
85
85
85
69
81
54
65
54
54
-
35
82
82
82
-
113
25
136
103
127
136
103
-
MODEL
T/TA(S)
T/TA 16
T/TA 22
T/TA 40
T/TA 80
TAS 16
TAS 40
TAS 80
TAS 800 E
82
100
103
124
82
103
122
151
33
36
40
49
33
30
36
58
40
43
63
77
30
39
46
85
ITA 30
ITA 45
ITA 75
ITAS 30
ITAS 45
ITAS 70
120
150
170
120
149
204
39
50
59
39
57
65
IMA 61 A(R)
IMA 111 A(R)
IMA 185 A(R)
IMAC 2000 E
IMAC 2000 S
IMAC 4000 E
145
-
G 15 E
G 30 E
G 45 E
GA 25 E
GA 42 E
GA 60/85 E
GA 60/85 E(V)
GA 110 E
GA 110 E(V)
AGA 45 E
AGA 75 E
AGA 100 E
AGA 102 E
AGA 111 E
ITA(S)
IMA
IMAC
COOLSPACE
G/GA(V)(E)
AT 306
Thermo AT 306
AT 307
AT 400(C)
AT 500(C)
BioEnergy 1
BioEnergy 2
C-kit AT 400/500
INCLUDING PACKING
WEIGHTS
F
KG
19
26
32
13,5
46(46)
46(46)
60(63)
57(61)
-
6
11,5
13
13
16
73(55) 36
55
36
76
55
53
55
-
70
70
85
85
85
-
32
41
51
82
87
98(174)
98(174)
87
98
-
DIMENSIONS IN CM
WEIGHTS
L
B
H
KG
52
60
73
54
70
110
110
129
29
21
30
30
29
40
50
50
67
67
30
42
43
48
44
60
60
94
94
113
113
155
155
155
84
84
75
75
75
60
70
101
101
101
52
67
85
110
110
60
90
15
67
61
90
137(162) 102
172(197) 67
61
90
137
102
109
62
60
62
87
60
62
87
50
131
32
131
122
32
131
122
59
78
17
85
168
211
85
168
27
37
52
70
86
84
7,5
13
21
14
17
41
41
71
71
PROHEAT 40
PROHEAT 60
PROHEAT 80
105
112
122
46
54
68
160
170
189
137
173
197
115
119
132
49
57
71
174
184
202
155
190
210
PRODRY 35
PRODRY 55
PRODRY 80
55
54
65
54
56
73
88
96
115
35
40
61
60
63
65
53
54
70
68
78
67
38
43
65
127
175
30
130
68
160
63
81
115
179
*
*
AGA(E)
36
AT
PROHEAT
PRODRY
BioEnergy
BX
CH
VTB
TB
TTV
COOLSPACE 1
COOLSPACE 2
64
157
65
81
BX 3
BX 9
BX 15
28
35
52
33
45
49
37
37
39
86
37
38
66
55
34
34
52
40
28
37
43
31
31
48
85
39
45
58
40
68
98
55
-
54
-
VAL DAYSTAR
VAL MIDI
VAL 6 KB
VTB 3000
VTB 9000
VTB 15000
PROHEAT 18
CH 3
CH 12
CH 18
VAL
TB4E/40Q
TB4E/50Q
TB6E/40Q
TB6E/50Q
TTV 4500
TTV 7000
MULTITANK 700
MULTITANK 1000
Depending on version
71
91
66
69
81
91
58
-
31
-
52
62
52
62
51
62
52
62
52
62
51
62
32
33
32
33
21
24
114
114
71
71
6
11,5
13
36
40
40
28
36
36
34
49
49
7
13,5
15
95
-
10,5
17,5
33
40
11
23
28
45
72
102
108
38
65
55
36
36
46
57
28
37
42
35
35
51
70
38
45
58
11,5
21
39
53
*
*
*
18
38
53
71
87
42
*
70
96
65
62
42
*
66
67
72
42
32
*
93
93
8
10,5
8
10,5
12,5
15
52
62
52
62
59
69
52
62
52
62
59
69
32
34
32
34
39
40
114
114
71
71
127
164
59
127
165
53
64
86
63
*
43
58
9
11,5
9
11,5
13,5
16,2
64
86