Sunteți pe pagina 1din 20

Toluene +water feed rate

Viscosity
Density of Water (high dense)
Density of Toluene (less dense)
Time required for seperation
Liquid Hold up volume
say 80% occupancy maintained in decanter
Required Volume

line size

200 LPH
178.72 Kg/hr
0.59 cp
1000 Kg/m
867 Kg/m
0.4436 hr
26.6 min
88.7218 L
80%
110.9 L
0.110902 m

10 inch
254 mm
0.254 m
0.050645
2.189794

Azeo composition
Toluene
80% w/w
Water
20% w/w

Toluene
Water
Avg

Sp. Gr
0.867
1
0.8936

Toluene +water Colletion rate

Residence Time considered

Vol of decanter required

line size

8
203.2
0.2032

inch
mm
m

CS Area of line
Length of the line required

0.0324
3.4246
3425

m
m
mm

200 LPH
3.333333 LPM

26.64 min

(Assumed)

111.00 L
0.111 m

10
254
0.254

inch
mm
m

12
304.8
0.3048

inch
mm
m

14
355.6
0.3556

inch
mm
m

0.0506
2.1917
2192

m
m
mm

0.0729
1.5220
1522

m
m
mm

0.099
1.118
1118

m
m
mm

16
406.4
0.4064

inch
mm
m

0.130
0.856
856

m
m
mm

Reactor Pressure (Guage)

g
Density of Tol+water

Height

0.1
0.097
9808.809
9.810
893.000

1.120

Kg/cm
atm
Pa

0.2 Kg/cm
0.194 atm
19617.619 Pa

0.3 Kg/cm
0.290 atm
29426.428 Pa

m/sec

9.810 m/sec

9.810 m/sec

Kg/m

893.000 Kg/m

2.239 m

893.000 Kg/m

3.359 m

S-ar putea să vă placă și