Documente Academic
Documente Profesional
Documente Cultură
Regulated
Converters
Description
DC/DC Converter
RP10-E
10 Watt
3
2 x 1
Single & Dual
Output
3Y
The RP10-E series DC/DC converters are certified to UL 60950-1 and cUL 60950-1. This makes them
ideal for all telecom and industrial applications where approved safety standards are required. The
industry standard 2 x 1 package meets military standards for thermal shock and vibration tolerance
and is available with an optional remote on/off control pin. This series is also available with the /M1 and
/M2 option which is particularly suitable for extended temperature range applications.
wa
EAR
rranty
Selection Guide
Part Number
Input
Output
Output
Input(1) Efficiency(1) Max. Capacitive
Voltage Range Voltage
Current
Current
typ.
Load(2)
[VDC] [VDC] [mA] [mA] [%]
[F]
RP10-123.3SE(3,4) 9-18 3.3 2000 688 80
6800
RP10-1205SE(3,4)
9-18
5
2000
1029
81
4700
RP10-1212SE(3,4) 9-18 12 830 988 84
690
RP10-1215SE(3,4) 9-18 15 670 997 84
470
RP10-243.3SE(3,4)
18-36
3.3
2000
344
80
6800
RP10-2405SE(3,4) 18-36 5 2000 508 82
4700
RP10-2412SE(3,4)
18-36
12
830
494
84
690
RP10-2415SE(3,4) 18-36 15 670 499 84
470
RP10-483.3SE(3,4) 36-75 3.3 2000 172 80
6800
RP10-4805SE(3,4)
36-75
5
2000
248
84
4700
RP10-4812SE(3,4) 36-75 12 830 241 86
690
RP10-4815SE(3,4) 36-75 15 670 241 87
470
RP10-1205DE(3,4)
9-18
5
1000
992
84
680
RP10-1212DE(3,4) 9-18 12 416 1002 83
330
RP10-1215DE(3,4) 9-18 15 333 991 84
110
RP10-2405DE(3,4) 18-36 5 1000 502 83
680
RP10-2412DE(3,4)
18-36
12
416
489
85
330
RP10-2415DE(3,4)
18-36
15
333
496
84
110
RP10-4805DE(3,4) 36-75 5 1000 248 84
680
RP10-4812DE(3,4)
36-75
12
416
242
86
330
RP10-4815DE(3,4) 36-75 15 333 245 85
110
Notes:
Note1: Maximum value at nominal input voltage and full load.
Note2: Test by minimum Vin and constant resistor load.
Model Numbering
E196683
RP10-__ __ _E/_ _
Input Voltage
Output Voltage
UL60950-1 Certified
Package(4)
Control Logic(3)
Single or Dual
Ordering Expamples:
RP10-1205SE/P = 12V Input, 5V Output, Standard Temp. Range, Positive Logic CTRL pin fitted
RP10-4805DE/M1-HC = 48V Input, 5V Output, Extended Temp. Range, No CTRL pin, Heat-sink fitted
Notes:
Note3: add suffix M1 for higher efficiencies and extended temperature range
add suffix P for CTRL function with Positive Logic (1=ON, 0=OFF)
add suffix N for CTRL function with Negative Logic (0=ON, 1=OFF)
Note4: add suffix -HC for premounted Heat-sink and clips
www.recom-power.com
REV.: 1/2016
PD-1
RP10-E
DC/DC Converter
Series
Specifications measured at Ta = 25C, nominal input voltage, full load otherwise noted
BASIC CHARACTERISTICS
Parameter
Input Voltage Range
Condition
Min.
Typ.
Max.
9VDVC
18VDC
36VDC
12VDC
24VDC
48VDC
18VDC
36VDC
75VDC
none
Input Filter
Pi-Type
Start-up time
30mAp-p
36VDC
50VDC
100VDC
20ms
270kHz
of full load
(6)
300kHz
10%
Single
measured by 20MHz bandwidth
Dual
50mVp-p
75mVp-p
Positive Logic
DC-DC ON
DC-DC OFF
Negative Logic
DC-DC ON
DC-DC OFF
Remote ON/OFF(7)
DC-DC OFF
Notes:
Note5:
Note6:
Note7:
330kHz
20mA
DC-DC ON
-0.5mA
+1.0mA
RP10-1205SE
Efficiency vs. Output Current
95
85
90
80
80
Efficiency [%]
Efficiency [%]
85
75
70
65
60
55
9Vin
12Vin
18Vin
50
45
40
10
20
30
40
50
60
70
80
90
75
70
65
60
55
100
10
11
12
13
14
15
16
17
18
REV.: 1/2016
www.recom-power.com
RP10-E
DC/DC Converter
Series
Specifications measured at Ta = 25C, nominal input voltage, full load otherwise noted
RP10-2405SE
Efficiency vs. Output Current
95
90
85
80
Efficiency [%]
Efficiency [%]
85
75
70
65
60
55
18Vin
24Vin
36Vin
50
45
80
75
70
65
40
60
10
20
30
40
50
60
70
80
90
100
18
20
22
24
26
28
30
32
34
36
66
72
75
RP10-4805SE
Efficiency vs. Output Current
95
90
84
80
Efficiency [%]
Efficiency [%]
85
75
70
65
60
55
36Vin
48Vin
75Vin
50
45
40
10
82
80
78
76
74
20
30
40
50
60
70
80
90
100
36
40
44
48
52
56
60
REGULATIONS
Parameter
Condition
Value
1%
0.2%
0.5%
1.0%
5%
250s typ.
REV.: 1/2016
PD-3
RP10-E
DC/DC Converter
Series
Specifications measured at Ta = 25C, nominal input voltage, full load otherwise noted
PROTECTIONS
Parameter
Condition
Value
3.9VDC typ.
6.2VDC typ.
15VDC typ.
18VDC typ.
% of Iout rated
150% max.
I/P to O/P
I/P (O/P) to case
500VDC
1.6kVDC/1 minute
1.6kVDC/1 minute
1G min.
Isolation Capacitance
300pF max.
Notes:
Note8: This power module is not internally fused. An input line fuse must always be used.
ENVIRONMENTAL
Parameter
Condition
Value
-25C to +100C
-40C to +85C
+105C
Temperature Coefficient
0.02%/C max.
Thermal Impedance
Operating Humidity
without Heat-Sink
with Heat-Sink
12C/Watt
10C/Watt
non-condensing
5% - 95% RH
Thermal Shock
MIL-STD-810F
Vibration
MIL-STD-810F
MTBF
(10)
Derating Graph(9,11)
RP10-4805SE with Heat-sink
100
100
80
80
RP10-4805SE
60
40
20
60
40
20
0
0
-25
-20
20
40
60
80
77
-25
100
-20
20
40
60
80
81
100
REV.: 1/2016
www.recom-power.com
RP10-E
DC/DC Converter
Series
Specifications measured at Ta = 25C, nominal input voltage, full load otherwise noted
RP10-4805SE/M1
RP10-4805SE/M1-HC
80
80
100
100
60
40
20
0
-40
-20
20
40
60
60
40
20
0
-40
80 100
85
-20
40
20
80 100
88
60
Notes:
Note9: M1 version is more efficient, therefore, it can be operated in a more extensive temperature range than standard version.
Note10: BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40C. (Ground fixed and controlled environment).
Note11: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-
number not shown here please contact our technical support service at techsupportAT@recom-power.com.
UL General Safety
Standard
UL60950-1 1st Ed.: 2003
C22.2 No. 60950 1st. Ed.: 2003
E196683
EMC Compliance
Condition
Standard / Criterion
ESD
Radiated Immunity
Fast Transient(13)
Surge(13)
Conducted Immunity
EN55022, Class A or B
C2
+VOUT
+VIN
DC
C1
EN61000-4-2, Criteria B
EN61000-4-3, Criteria A
EN61000-4-4, Criteria B
EN61000-4-5, Criteria B
EN61000-4-6, Criteria A
LOAD
EMI Standard
(12)
DC
-VOUT
-VIN
Notes:
Note12: The standard modules meet EMI Class A or Class B with external components, see filter suggestions below.
Note13: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor
C3
Recom suggests: Nippon chemi-con KY series, 220F/100V.
C2
Input
Fuse
+VOUT
+VIN
DC
DC
C1
LOAD
C1
+VOUT
+VIN
Input
COM
DC
DC
-VOUT
-VOUT
-VIN
-VIN
C3
MODEL
C3
C2
RP10-12xxS_DE
Fuse
C2
C3
2.2F/25V
1206 MLCC
1000pF/2kV
1808 MLCC
1000pF/2kV
1808 MLCC
N/A
1000pF/2kV
1808 MLCC
1000pF/2kV
1808 MLCC
N/A
1000pF/2kV
1808 MLCC
1000pF/2kV
1808 MLCC
+VOUT
+VIN
LOAD
RP10-24xxS_DEDC
C1
COM
DC
RP10-48xxS_DE
-VOUT
-VIN
www.recom-power.com
C1
LOAD
Input
LOAD
Fuse
C2
LOAD
REV.: 1/2016
PD-5
C3
L1
Fuse
RP10-E
+VOUT
+VIN
Input
C1
C2
DC/DC Converter
LOAD
DC
Series
DC
-VOUT
-VIN
Specifications measured at Ta = 25C, nominal input voltage, full load otherwise noted
C4
C3
DC
C2
DC
C1
LOAD
C1
+VOUT
+VIN
Input
C2
COM
DC
DC
-VOUT
-VOUT
-VIN
-VIN
C4
MODEL
C4
C1
C2
C3/C4
L1
N/A
1000pF/2kV
1808 MLCC
CMC: 325H
ref: WE 744290321
ref.: CMC-06
N/A
1000pF/2kV
1808 MLCC
CMC: 325H
ref: WE 744290321
ref.: CMC-06
2.2F/100V
1812 MLCC
1000pF/2kV
1808 MLCC
CMC: 325H
ref: WE 744290321
ref.: CMC-06
C3
3.3F/50V
1812 MLCC
RP10-12xxS_DE
L1
+VOUT
+VIN
Input
LOAD
Fuse
DC
2.2F/50V
COM
1812 MLCC
C2
LOAD
C1
RP10-24xxS_DE
DC
-VOUT
-VIN
RP10-48xxS_DE
LOAD
Input
L1
Fuse
+VOUT
+VIN
LOAD
L1
Fuse
2.2F/100V
1812 MLCC
C4
Type
Value
Material
Case
Base
Potting
without Heat-sink
with Heat-sink
Package Weight
without Heat-sink
with Heat-sink
27g
37.89g
50.8
25.4
5.60
10.2
Pin Connections
Pin #
1.0
15.20
2.50
5.10
20.30
10.20
Bottom View
23
10.20
12.70
Single
Dual
+Vin
+Vin
-Vin
-Vin
+Vout
No Pin
Com
-Vout
-Vout
CTRL
CTRL
+Vout
REV.: 1/2016
www.recom-power.com
RP10-E
DC/DC Converter
Series
Specifications measured at Ta = 25C, nominal input voltage, full load otherwise noted
Dimension Drawing (mm) with Heat-sink
24.20
1.30
50.00
1.95
Top View
Heat-sink
1.30
25.4
5.6
10.2
16.8
5.85
1.40
1.0
15.20
2.50
5.10
20.30
56.80
PACKAGING INFORMATION
Parameter
Packaging Quantity
Type
without Heat-sink Tube
with Heat-sink Tray
Value
9pcs.
20pcs.
-55C to +125C
Storage Humidity
5% - 95% RH
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOMs explicit written
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 1/2016
PD-7