UE shall be capable of monitoring max. 54 carriers including all RATs using gaps.

In
addition to this requirements, UE shall be capable of monitoring at least 7 carrier
frequency layers comprising of any combination of E-UTRA FDD, E-UTRA TDD, UTRA
FDD, UTRA TDD, and GSM layers, cdma2000 1x and HRPD layers. TS36.300 shows
scenario A to C show us intra frequency handover whereas D to E do inter frequency,
which requires measurement gap.

A cell shall be recognized by UE within 480 ms defined as TBasic_Identity_Inter.


Depending on how many carriers are monitored, inter-frequency measurement time is
allowed UE to use in total, which is defined as TIdentity_Inter. TInter1 can be 60 or 30
ms depending on gap pattern ID. N freq is number of carriers for all RATs but GSM. If it
is equal to 0 if no GSM carrier is being monitored and 1 if up to 32 is being done for
MGRP of 40 ms. This total timeout can be used in in TS36.521-3 RRC conformance