Documente Academic
Documente Profesional
Documente Cultură
900
Power-to-Design circuits
VEST, Inc. 3250 W, Big Beaver Road, Suite 440, Troy, MI 48084 USA
Tel: +1 248 649 9550
Email: sales@VESTusa.com
Visit: www.VESTusa.com
VEST, Inc.
HyDraw CAD900 Software Product License Agreement
Notice: Read this before installing the software.
Carefully read the terms and conditions of this agreement before
opening the product package. Opening the package indicates your
acceptance of these terms and conditions. If you do not agree with
the terms and conditions of this Agreement, promptly return the
package unopened to the place where you obtained it.
1.
2.
2.
3.
4.
1.
2.
3.
Our entire liability and your exclusive remedies for our liability
of any kind (including liability for negligence except liability for
personal injury caused solely by our negligence) for the
Licensed Software Product covered by the Agreement and all
other performance or non-performance by us under or related
to this Agreement are limited to the remedies specified by this
Agreement.
4.
5.
License
1.
Limited
Definitions
Disclaimer of Warranty
3.
Termination
This Agreement is effective until terminated. You may terminate it
any time by destroying the Licensed Software Product. It will also
terminate if you do not comply with any term or condition of this
Agreement. You agree upon termination to destroy the Licensed
Software Product.
General
You are responsible for installation, management and operation of
the Licensed Software Product.
HyDraw CAD900 User Manual: v160607 VEST, Inc. 2002 -2016. All rights reserved.
Contents
1.
2.
Introduction.................................................. 1
Support ......................................................... 3
Workspace ................................................ 4
3.
4.
5.
6.
7.
8.
Insert Symbol................................................ 44
Insert External Port ...................................... 48
Search Components ..................................... 52
Search Sub-systems ..................................... 58
Insert from Parts List .................................... 62
Insert Terminators ....................................... 63
Insert Symbol Port........................................ 64
Insert Envelope............................................. 65
Insert Gauge Port ......................................... 66
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.
48.
FluidPowerTools.com................................ 144
68. Data Access Settings .................................... 145
69. Help for FluidPowerTools.com.................... 146
70. Internet Settings .......................................... 150
Annotations............................................... 109
49.
50.
51.
52.
53.
54.
1. Introduction
Welcome to VEST HyDraw CAD900
Create accurate, error free, professionally drawn
hydraulic circuits, parts lists, and quotations
quickly and easily.
Drag-and-drop smart symbols into a drawing
with point-and-click component selection.
The smart connection lines snap to ports and
self-route with jumpers.
Auto BOM generation ensures accuracy of your
Bill of Materials. Easily insert it into the circuit
drawing, or export it to Microsoft Excel.
Get started with over 8,000 ISO 1219-1 compliant
symbols covering both industrial and mobile
hydraulics. Remember your data and rules using
HyDraw custom database. Ensure up-to-date
pricing of components by linking your ERP data to
HyDraw.
Circuit design data can be easily ported to
downstream manifold design and CAM systems.
HyDraw can access manufacturer component
data from FluidPowerTools.com, a fee-based
service from VEST. Also, submit your circuit to
QuickManifolds.com for instant manifold design.
HyDraw CAD drawing area with HyDraw CAD Ribbon menu, HyDraw Library Explorer, and HyDraw Property Manager
VEST, Inc.
HyDraw CAD900
Smart Symbols
HyDraw symbols are created using primitive shapes,
such as lines, polylines, rectangles, squares, circles,
circular arcs, ellipsis. They represent components
with specified functions or method of operation in
the de-energized (at rest) position, or component
specific rule that do not have a clearly defined deenergized position. A pool of ISO specified primitive
shapes are included in the library to help you design
your own generic symbols. HyDraw symbols also
include port identification and port numbering,
which is essential for manifold design.
ISO guidelines
VEST has adhered to ISO guidelines of Module
System (1Module = 2 Millimeter), where the symbol
fits into a grid and presents a symmetry. The use of
layer properties for assigning ISO defined color to
Supply line, Return line, Pilot line, Drain line,
Envelope line, and Flow direction exhibits appealing
color graphics, which help in instant understanding
of the operational aspect of the component. Layer
properties are also utilized for naming ports,
positions and solenoids. (both US and European
pattern)
Search
The new and powerful HyDraw CAD900 Search from
library command searches general or OEM specific
symbols and circuits from
www.FluidPowerTools.com, saving time and effort.
Teamwork
HyDraw helps standardization and teamwork.
Multiple users within a local area network can share
a common HyDraw library. This enhances
productivity of the design and engineering team.
Customization
Customize HyDraw to your specific need using the
library and data management console. Save custom
components data with symbols tagged to a specific
model code and relevant OEM catalog data.
More
Dynamic Directional Control (DC) Valve design and
OEM-specific circuit design with Parts List from
component properties held in the library make the
software very productive.
Net List creation, Manifold Cost estimation and
interface to FluidPowerTools.com enable significant
cost and time savings.
Work Smart! Use HyDraw today.
VEST, Inc.
HyDraw CAD900
2. Support
User Manual
The HyDraw CAD900 User Manual provides comprehensive
information on the features, commands, usage, processes, and
design methodology of HyDraw.
The user manual can be used as a comprehensive reference to
the command set and usage of HyDraw.
**Click the Circuit Diagrams command on the Help ribbon menu to view the user manual in the Adobe Acrobat .pdf format.
Support
If you have a question about HyDraw CAD900 email us at
support@VESTusa.com.
Please include the following:
VEST, Inc.
Workspace
VEST, Inc.
HyDraw CAD900
HyDraw Startup
HyDraw Shortcuts
HyDraw Options
3. HyDraw Startup
Note:
For HyDraw CAD installation,
refer Ch73.
VEST, Inc.
HyDraw CAD900
VEST, Inc.
HyDraw CAD900
5. HyDraw Shortcuts
Shortcut command for HyDraw introduced for easy access from command line.
The predefined HyDraw shortcuts or aliases:
VEST, Inc.
YL
YP
YCP
YCR
YCS
YCC
YCD
YCW
YC1
YC2
YC3
YC4
YC5
YE
YG
YM
YR
YB
YI
YPA
YPO
YN
YO
Library Explorer
Property Manager
Pressure Connection Line
Reservoir Connection Line
Suction Connection Line
Control Connection Line
Drain Connection Line
Working Connection Line
Custom Connection Line1
Custom Connection Line2
Custom Connection Line3
Custom Connection Line4
Custom Connection Line5
Insert Envelope
Insert Gauge Port
Match Connection Properties
Refresh Properties
Update Balloon
Assign Item ID
Parts List
Ports List
Net List
HyDraw Options
HyDraw CAD900
Symbols and external ports inserted from HyDraw Library Explorer to design schematic
VEST, Inc.
HyDraw CAD900
1.
Alternatively,
on the HyDraw
2.
3.
Use
icon to Show/Hide the Library
Explorer.
VEST, Inc.
HyDraw CAD900
4.
HyDraw Options
VEST, Inc.
HyDraw CAD900
10
Display assigned properties of the selected symbol using the HyDraw Property Manager
VEST, Inc.
HyDraw CAD900
11
1.
HyDraw CAD900
12
VEST, Inc.
HyDraw CAD900
13
System tab
The System tab page displays properties
of the complete circuit.
It automatically expands all sections,
whenever the schematic is opened in
the drawing.
When the item is selected or the
schematic is open, the respective menu
bar expands and the assigned values
display.
Click
to expand/collapse.
HyDraw CAD900
14
2.
1.
2.
3.
VEST, Inc.
HyDraw CAD900
15
8. HyDraw Options
Customize HyDraw settings, such as Application, Units, Item ID, Connection, External Port, Lists & Charts, Library Path, Misc., Internet Settings, ERP Settings, Gauge port, Display
Format and Drawing Template.
1.
Application
2.
3.
Click OK.
VEST, Inc.
HyDraw CAD900
16
2.
Units
2.
CAUTION!
Units should not be changed after
symbol insertion.
3.
VEST, Inc.
HyDraw CAD900
17
2.
3.
4.
5.
VEST, Inc.
HyDraw CAD900
18
3.
External Port
Customize the external port in a circuit.
1.
2.
3.
4.
Note:
For adding custom shape to the HyDraw library
refer Ch77.
VEST, Inc.
HyDraw CAD900
19
4.
Parts List
Customize the Parts List format
1.
2.
3.
then click
4.
5.
6.
.
7.
VEST, Inc.
HyDraw CAD900
20
VEST, Inc.
HyDraw CAD900
21
Hose List
Customize the Hose List format.
1.
2.
then click
3.
4.
5.
6.
.
7.
Click
VEST, Inc.
HyDraw CAD900
22
VEST, Inc.
HyDraw CAD900
23
Ports List
Customize the Ports List format.
1.
2.
3.
4.
below the
5.
6.
7.
.
.
Click
VEST, Inc.
HyDraw CAD900
24
Note:
To learn more about Ports List, refer Chapter 56.
VEST, Inc.
HyDraw CAD900
25
Actuation Chart
Customize the Actuation Chart format.
1.
2.
3.
below the
5.
6.
7.
.
.
Click OK.
The selected properties are displayed in a tabular
form when the Actuation list is created in the
drawing.
VEST, Inc.
HyDraw CAD900
26
Net List
Customize the Net List format.
1.
2.
3.
4.
5.
6.
7.
VEST, Inc.
HyDraw CAD900
27
Design Note
Customize the Design Note List format
1.
2.
3.
4.
5.
6.
7.
.
.
Text
The Display in the Upper Case option shows the list
in the upper case. Also, you can change the text size
of the list.
Heading
The Heading dropdown selects the list header
direction.
For example, top, bottom or none.
Direction
Sort the list in an ascending or descending order.
The selected properties are displayed in a tabular
form when the Design Note list is created in the
drawing.
VEST, Inc.
HyDraw CAD900
28
5.
Library Path
Multiple users have easy access to the library and components
data from a common source over a network.
1. Click the Library Path tab of HyDraw Options.
The Library Path tab page displays.
2. Select the Local Library option.
3. Select the Enable modification check box to allow you to
modify library.
4. Click Browse
5. Navigate to the folder where the HyDraw library data is
stored.
6. Repeat above steps for each of the specified HyDraw library
paths.
7. Click OK.
All the HyDraw library paths are configured.
8.
Sub-systems
This section specifies the folder path that contains usercreated circuit drawings and its menu data.
VEST, Inc.
HyDraw CAD900
29
6.
Misc.
Text Size
1.
In the Text size group box, select the appropriate text size from
the respective list box for item ID and display properties.
2.
VEST, Inc.
HyDraw CAD900
30
Envelope Line
1.
2.
Click the Color button to open the color box and select the
required color.
3.
4.
5.
6.
Load on startup
The Library Explorer and Property Manager can be loaded to HyDraw on
startup.
1.
In the Load on startup group box, select the application you want
to use for loading on startup.
The selected application loads and docks to the HyDraw drawing.
2.
HyDraw CAD900
31
Symbol Color
All symbols in the HyDraw library are created with the ISO standard colors.
You can also change the color of these symbols to black.
1.
2.
Colored Symbol
Black Symbol
VEST, Inc.
HyDraw CAD900
32
Solenoid Naming
Solenoid naming conventions for Directional Control Valve symbols are different
for both US and Europe patterns.
You can only view one naming convention for a pattern at a time.
1.
2.
Solenoid naming
VEST, Inc.
HyDraw CAD900
33
Command options
3.
Select the Show options on command line check box, if you need to
show the selection options on the command line.
4.
Note:
If the Show options on command line option is unselected,
only a few HyDraw commands will display a dialog box.
Command options
VEST, Inc.
HyDraw CAD900
34
7.
Internet Settings
Click Internet Settings in the Services tab of the HyDraw CAD ribbon
menu.
The Internet Settings of the HyDraw Options dialog box displays.
2.
Note:
Refer Chapter 75, Para 2 for detailed configuration settings.
VEST, Inc.
HyDraw CAD900
35
8.
ERP Settings
2.
Browse the path of My local ERP data and select the ERP data.
3.
Browse and select the Service URL for the online ERP data.
4.
5.
Note:
VEST, Inc.
HyDraw CAD900
36
9.
Connection Tab
2.
Select the Color from the drop down or the color palette.
3.
4.
5.
In the Dot section, select the connection dot size from large,
medium, and small.
Click the Reset Connection Properties button, if you want to reset all
HyDraw CAD900
37
Note:
To add more custom connection lines,
Refer HyDraw Library Manager 2016 User Manual, CH 29.
VEST, Inc.
HyDraw CAD900
38
10. Item ID
Enclose or balloon the envelope ID, external port ID, component ID,
accessories ID, and hoses item ID.
1.
2.
3.
4.
5.
6.
7.
8.
9.
VEST, Inc.
HyDraw CAD900
39
2.
3.
Set the Gauge port insertion distance default values in the External
Port tab.
Else, set the locations in this tab.
4.
Select the default symbols for the Open and Close options from the
drop down.
5.
Note:
For more information, refer chapter No.17.
VEST, Inc.
HyDraw CAD900
40
2.
3.
Click Reset to update the list of display formats from the HyDraw
Library database.
4.
VEST, Inc.
HyDraw CAD900
41
2.
3.
4.
CAUTION:
Define Title Block and Border name, per the title block and border name
saved in the template.
Note:
Default Template path should be C:\Users\User\AppData\Local\VEST\HyDraw
CAD900\R900\enu\Template", you can also assign custom template path.
VEST, Inc.
HyDraw CAD900
42
Insert Symbols
VEST, Inc.
HyDraw CAD900
Insert Symbol
10
11
Search Components
12
Search Sub-systems
13
14
Insert Terminator
15
16
Insert Envelope
17
43
9. Insert Symbol
The Insert Symbol command in the Circuit tab of the HyDraw CAD ribbon menu enables you to insert symbols, external ports, and component models into the drawing.
The Component library is a
logically structured symbol
library of hydraulic, pneumatic,
and electrical systems.
VEST, Inc.
HyDraw CAD900
44
VEST, Inc.
Double click or Drag and drop symbol from Component Library into the drawing
HyDraw CAD900
45
Replace Symbol
1. Select the symbol to be
replaced in the drawing.
2. Select the Replace
symbol check box in the
HyDraw Library
Explorer.
3. Drag and drop the new
symbol in the drawing.
Alternatively,
4. Double click the new
symbol in the HyDraw
Explorer window.
Symbol preview appears
on the drawing space.
The Specify insertion
point prompts display.
5.
VEST, Inc.
HyDraw CAD900
46
1.
1.
6.
Click
on the Model data caption bar to select the Model
data from the library.
The Pump/Motor Adaptor dialog box displays.
Automatically all the properties of the respective motor and
pump populates and the most appropriate data is selected.
2.
3.
Note:
Pump and Motor symbols must touch the adaptor at both ends.
The Pump and Motor must have pre-defined properties (For
example, Frame Size, Pump Mount and Shaft length) in order to
prompt for a selection.
You can do an embedded search for a single Motor frame size and
Pump mount from multiple values that are separated by slash (/).
E.g. Motor Frame Size: 145TC/245TC/.. etc.
Pump Mount: SAE 2B/SAE 4B/.. etc.
VEST, Inc.
HyDraw CAD900
47
Click
3.
4.
5.
6.
Select Port Type from SAE O-ring, SAE Flange, BSP, NPT, and
Metric.
On selection, different port sizes of the respective port type
are displayed automatically.
Choose the required one.
7.
VEST, Inc.
HyDraw CAD900
48
3.
Click
on the Port data caption bar to select
the port data from the library.
The Configure Port dialog box displays.
4.
5.
6.
Note:
The port data can embed With O-ring and With Through
Bolt Hole from HyDraw to MDTools.
HyDraw Property Manager Port
VEST, Inc.
HyDraw CAD900
49
Click
2.
3.
4.
VEST, Inc.
HyDraw CAD900
50
2.
2.
3.
VEST, Inc.
HyDraw CAD900
51
Search Components
1.
Click
tab on the HyDraw
Library Explorer window.
The Search From Library tab
page displays.
2.
Select Components.
3.
Select an appropriate
application.
4.
My Subscription Information
Contact
VEST, Inc.
HyDraw CAD900
52
5.
Manufacturer options
6.
7.
8.
VEST, Inc.
HyDraw CAD900
53
Select Property
Select Property
Preview symbols
10. Click the Search for Model Code button.
All model codes with the assigned custom properties are displayed in
the Search results pane.
VEST, Inc.
HyDraw CAD900
54
VEST, Inc.
Component data
HyDraw CAD900
55
13. Right click and select Search for complete Model Code from the
context menu to display all model codes in the model family.
VEST, Inc.
HyDraw CAD900
56
15. Select the symbol in the preview pane; drag and drop
Alternatively, double click the symbol to insert the symbol into the
drawing.
16. Replace the symbol in the drawing with another one from the library
by selecting the Replace symbol checkbox in the HyDraw Library
Explorer window, if required.
17. Drag and Drop the symbol in the drawing
Alternatively, double click the symbol to insert the symbol into the
drawing.
The Specify insertion point prompts display.
18. Specify the Insertion Point or Select the Rotate/Flip option.
The symbol is inserted in the drawing.
Modify Search
HyDraw CAD900
57
Click
4.
Select Sub-systems.
3.
Category options
VEST, Inc.
HyDraw CAD900
58
5.
6.
Manufacturer options
VEST, Inc.
HyDraw CAD900
Select Property
59
7.
9.
HyDraw CAD900
10.
Select the sub system in the preview pane; drag and drop it into the drawing.
Alternatively, double click the symbol.
The Specify insertion point prompts display.
11.
12.
You can add a new sub system by clicking the New Sub System link on
the search page.
i.
ii.
Click OK.
iii.
VEST, Inc.
HyDraw CAD900
61
Select Circuit > From Parts List from the Insert Symbol option on the
HyDraw CAD ribbon menu.
The Insert Symbol from Parts List dialog box displays.
2.
Enter the Part list starting row at option and the Model Code column
number.
3.
Click Browse...
Select the required Excel file containing the Parts list and click Open.
Contents of the Excel file are displayed.
Type Model Code column number in the textbox, if it is not automatically
entered.
6.
Select the symbols and click Insert or Insert All to insert all the symbols
into the drawing.
For Insert symbol detailed information, refer CH 9.
VEST, Inc.
5.
HyDraw CAD900
62
1.
Note:
The Net list can indicate unconnected circuit lines and ports.
When you rotate the symbol, the terminator also rotates along
with it.
VEST, Inc.
HyDraw CAD900
63
1.
3.
Enter the Port Name in the command window and press the
Enter key.
The Other Name: prompt displays.
4.
VEST, Inc.
HyDraw CAD900
64
2.
c. External ports are glued to the envelope and relocates the ports and maintain connectivity while
resizing the envelope.
d. Envelope data is attached to the envelope line.
VEST, Inc.
HyDraw CAD900
65
3.
VEST, Inc.
HyDraw CAD900
66
Make Connections
VEST, Inc.
HyDraw CAD900
18
Insert Connection
19
20
67
2.
Click on the Connection type from Pressure, Reservoir, Control, Drain, Suction,
Working option or Custom from Line1, Line2, Line3, Line4, and Line5 option on the
HyDraw CAD ribbon menu.
Connection lines are assigned with the default ISO color and line weight. You can
customize the connection lines.
Insert Connection sub menus
Select the first connection point on the drawing as the start point.
When the Auto Connect option is enabled:
The Select second connection point prompt displays.
4.
5.
6.
7.
Note:
VEST, Inc.
If a connection is drawn at the end/start of another similar type of connection line, which has a tolerance of 0.1inch or 2.54mm,
then connection lines automatically merge to form a single polyline.
HyDraw CAD900
68
VEST, Inc.
HyDraw CAD900
69
2.
3.
4.
5.
6.
Select Material.
8.
VEST, Inc.
HyDraw CAD900
70
Modify Connection
VEST, Inc.
HyDraw CAD900
21
Stretch Connections
22
Match Connections
23
Merge Connection
24
Reset Connections
71
1.
2.
3.
4.
5.
6.
Stretching a
connection line
VEST, Inc.
HyDraw CAD900
72
1.
2.
Match Orange to
Green
4.
Matched
Connection Line
VEST, Inc.
HyDraw CAD900
73
1.
2.
3.
VEST, Inc.
HyDraw CAD900
74
1.
2.
Reset Connection
Line
Connection Line
after Reset
VEST, Inc.
HyDraw CAD900
75
Specify Properties
VEST, Inc.
HyDraw CAD900
25
26
System Properties
27
Edit Properties
28
Copy Properties
29
Refresh Properties
30
31
Show/Hide Properties
32
Purge Properties
33
34
ERP Interface
76
1.
2.
Symbol
Click
to expand and then
select Hide or Show to hide
or show the respective
parameters.
Design Requirements
The Design requirements section enables you to search for the required
components by specifying a design parameter and value, from the library.
Click
on the Design Requirements caption bar to open Edit Port
Operating Parameters.
Click
on Edit Design Note to add the design notes to the component.
The Design Note Icon appears on the top of the Item ID.
HyDraw CAD900
77
3.
Model Data
Displays the details of the component selected.
Click Models linked to symbol to display the component models linked to this symbol.
Click all models to display all component models available to the component type of the
symbol.
VEST, Inc.
Click OK.
HyDraw CAD900
78
Add Accessories
You can add or replace accessories of the model code to
the symbol by selecting an appropriate button.
Replace Accessories
Click
on the Model Data caption bar to save
custom details in the library.
Save to Library
VEST, Inc.
HyDraw CAD900
79
4.
Accessories
The Accessories section displays the details of accessories assigned with the item.
This section also displays all documents and CAD files linked with the accessory.
Select from Library
You can fetch required accessories to your component from the library.
1.
Click
2.
on the Accessories caption bar to open Select Accessories from Library dialog box.
3.
4.
5.
Click OK.
6.
Click Search.
All available accessories of the selected component type display in the Available accessories pane.
7.
8.
Click Add.
The added model codes display in the Selected accessories pane.
9.
Select the model code and click Remove to remove the selected model code from the selected
accessories pane.
VEST, Inc.
HyDraw CAD900
Selected accessories
80
Click
3.
4.
Click OK.
Accessories section
Click
to expand the newly added accessories
menu.
6.
Save Accessories
Click
Click OK.
The new accessories are saved.
Save to HyDraw Library message box
VEST, Inc.
HyDraw CAD900
81
5.
Delete Accessories
1.
2.
Click
Documents section displays the documents linked with the selected component
model. You can delete and link documents from library.
Documents
Click
Click
model.
Documents Section
HyDraw CAD900
82
6.
CAD Files
The CAD Files section displays the CAD files linked with the selected component
model. You can delete and link CAD files from the library.
Click
Click
model.
on the CAD Files caption bar to delete the linked CAD files.
Select from library to link new CAD files to the selected component
VEST, Inc.
HyDraw CAD900
83
Components
External Ports
Envelopes
Accessories
VEST, Inc.
Schematic
HyDraw CAD900
84
1.
3.
VEST, Inc.
HyDraw CAD900
85
Click
3.
4.
5.
Select the required design requirements, if you want to copy from the
Design requirements checklist box.
6.
Select the Include accessories checkbox, if you want to copy the accessories
to the destination symbol.
7.
Select the Include Linked Documents and Linked CAD Files checkbox, if you
want to copy the linked Documents and CAD Files to the destination
symbol.
8.
Click Ok.
The properties are copied to the destination symbol(s).
VEST, Inc.
Copy Properties
HyDraw CAD900
86
1.
3.
4.
5.
6.
Refresh properties
VEST, Inc.
HyDraw CAD900
87
2.
4.
Update Status
Click Update.
The Update Property List message box displays the status.
6.
VEST, Inc.
HyDraw CAD900
88
3.
4.
Hiding a Property
VEST, Inc.
HyDraw CAD900
89
Click Circuit > Edit > Purge on the HyDraw CAD ribbon menu.
The Select Symbols prompt displays.
2.
3.
Specify the item, properties that are to be purged and press the
Enter key.
a.
b.
d.
Click OK.
A warning message box displays.
VEST, Inc.
HyDraw CAD900
90
4.
Click OK to continue
or
Click Cancel to exit.
VEST, Inc.
HyDraw CAD900
91
2.
3.
Click OK.
Purge Price Data warning box
Note:
Save the schematic with a different file name and/or
location before removing price information for your
convenience and future reference.
VEST, Inc.
HyDraw CAD900
92
1.
2.
3.
5.
6.
VEST, Inc.
HyDraw CAD900
93
Modify Symbols
VEST, Inc.
HyDraw CAD900
35
Move Symbol
36
Align Symbols
37
Rotate Symbols
38
Flip Symbols
39
40
41
42
Edit in Place
43
Delete a Symbol
44
Stack Symbols
45
46
47
48
94
1.
3.
Move Symbol
VEST, Inc.
HyDraw CAD900
95
1.
on the HyDraw
3.
4.
VEST, Inc.
HyDraw CAD900
96
1.
Rotate Left
1.
2.
Rotate Right
1.
2.
VEST, Inc.
Select a symbol
HyDraw CAD900
97
1.
Flip Horizontal
1.
2.
Flip Vertical
1.
2.
VEST, Inc.
HyDraw CAD900
98
1.
3.
Before
Before
4.
Note:
When aligning external ports (that are aligned with the envelope)
to symbol ports, in some cases the envelope line may pass through
the external ports.
In such cases, manually adjust the envelope line.
After
After
Symbol ports aligned vertically
VEST, Inc.
HyDraw CAD900
99
1.
on the
VEST, Inc.
HyDraw CAD900
100
on the HyDraw
3.
4.
5.
6.
Click OK.
The name or the other name of the port displays
with the symbol.
VEST, Inc.
HyDraw CAD900
101
1.
2.
3.
Note:
The changes affect only the symbol
in the drawing and not the master
symbol in the HyDraw Library.
VEST, Inc.
HyDraw CAD900
102
1.
2.
VEST, Inc.
HyDraw CAD900
103
1.
2.
3.
Note:
VEST, Inc.
Symbols to Stack
HyDraw CAD900
104
1.
on the
Symbol before
VEST, Inc.
HyDraw CAD900
105
1.
on the
Note:
VEST, Inc.
HyDraw CAD900
106
1.
Double click
the Design notes
icon of the symbol in the drawing.
The edit design note text box
displays.
By default, the design notes icon will
be in the Read only mode.
2.
to open in
3.
to save.
4.
Click
button to close.
VEST, Inc.
HyDraw CAD900
107
1.
2.
3.
4.
Note:
Changes affect only the symbol in the drawing and not the
master symbol in the HyDraw Library.
VEST, Inc.
HyDraw CAD900
108
Annotations
VEST, Inc.
HyDraw CAD900
49
50
51
Reassign Item ID
52
Reassign Hose ID
53
Recreate Balloons
54
109
1.
2.
3.
4.
Enter the text height value and press the Enter key.
The height of the text is changed.
VEST, Inc.
HyDraw CAD900
110
1.
3.
4.
5.
6.
Click OK.
The property of the text is rotated.
VEST, Inc.
HyDraw CAD900
111
2.
4.
5.
6.
Reassign Item ID
7.
Click OK.
8.
VEST, Inc.
HyDraw CAD900
112
1.
3.
4.
5.
Reassign Hose ID
Click OK.
7.
VEST, Inc.
HyDraw CAD900
113
1.
3.
4.
Click OK.
VEST, Inc.
HyDraw CAD900
114
1.
3.
4.
Click
on Property1 section to select property to
display in the required format.
The Select Property dialog box displays.
Select property and click OK.
5.
6.
7.
8.
Click Add.
VEST, Inc.
HyDraw CAD900
Select Property
115
Lists
VEST, Inc.
HyDraw CAD900
55
56
57
58
59
60
116
3.
4.
5.
VEST, Inc.
Click Next
HyDraw CAD900
117
The Create Parts List dialog box displays the details of the Parts
properties.
6.
Click
or
respectively.
7.
Click
8.
9.
VEST, Inc.
HyDraw CAD900
118
2.
Click the Lists & Charts tab and select Parts List.
The Parts List formatting box displays inside the tab.
3.
4.
5.
Click Add.
The Select Parts List Columns dialog box displays.
7.
8.
9.
Set the Start Column and the Start Row of the Parts list to be
inserted into the Excel template.
VEST, Inc.
HyDraw CAD900
119
Select a single or multiple ports. After the completion of selection, press the Enter key.
The Create Ports List dialog box displays.
3.
Select the Group identical items checkbox to group all identical items in the Ports list.
4.
5.
6.
Click
or
7.
Click
8.
Click Insert to Drawing to insert the Ports list as a separate list in the drawing.
9.
VEST, Inc.
HyDraw CAD900
120
2.
Click the Lists & Charts tab and select Ports List.
The Ports list formatting box displays inside the tab.
3.
4.
The Configure Columns section enables editing of the Display Name, Alignment,
and Width of the columns.
6.
Click
8.
Click OK.
The properties of the selected item are displayed in the Ports List formatting box
in the Configure columns section.
Same properties are displayed in the tabular form Ports list,
when creating the Ports list in the drawing.
VEST, Inc.
HyDraw CAD900
121
Select a single or multiple hoses. After the completion of selection, press the Enter key.
The Create Hoses List dialog box displays.
3.
Select the Group identical items checkbox to group all identical items in the Hose list.
Group identical items works only for the given numbering scheme in Option.
4.
Select the required format. If no format is selected, then the default format is applied.
5.
6.
Click
or
7.
Click
8.
Click Insert to Drawing to insert the hose list as a separate list in the drawing.
9.
VEST, Inc.
HyDraw CAD900
122
2.
Click the Lists & Charts tab and select Hose List.
The Hose list formatting box displays inside the tab.
3.
4.
5.
The Configure Columns section enables editing of the Display Name, Alignment, and Width
of the columns.
6.
Click
8.
Click OK.
The properties of the selected item are displayed in the Hose List formatting box in the
Configure columns section.
Same properties are displayed in the tabular form Hose list,
when creating the Hose list in the drawing.
VEST, Inc.
HyDraw CAD900
123
2.
3.
Press Enter.
The Solenoid Actuation Chart displays Function, Item ID-Solenoid ID, if applicable.
4.
Click
or
to move the selected item one row up or one row down,
respectively.
6.
Click
7.
Click Export to Excel to save the Solenoid Actuation chart as an Excel file
(.xls or .xlsx).
8.
Click Insert to Drawing to insert the Solenoid Actuation chart into the drawing.
You can customize the Actuation List Format from HyDraw Option.
Solenoid Actuation Chart
VEST, Inc.
HyDraw CAD900
124
Select symbols and connections. After completion of selection, press the Enter key.
The Create Net List box displays net name with the corresponding net items and status.
3.
indicating
By selecting a net on the Status column, the respective net is shown as hidden in the
drawing.
(In case of hidden connection lines at low zoom level, the hidden preview may not be visible.
If the connection is not correct, red dots appear along the connection points.)
4.
Click Clear Error Flags to remove the error flags from the drawing.
5.
6.
Click Export to save the Net list as an Excel file (.xls or .xlsx).
7.
8.
Net List
11. Click OK to exit or Click Cancel to cancel the Net list creation.
VEST, Inc.
HyDraw CAD900
125
Note:
The individual symbols of Slip-Cartridge valve cover and Insert are combined with & and treated
as a single entity, when creating the Net list.
CAUTION!
Do not create more than one connection to the connection points. This may result in an
incorrect Net list.
If OK is not pressed after net renaming, the corrections will be lost on recreation, with
default net naming style.
You can customize the Net List Format from HyDraw Option.
VEST, Inc.
HyDraw CAD900
126
3.
Click
or
to move the selected item one row up or one row down, respectively.
4.
Click
5.
Click Export to save the Design Note list as an Excel file (.xls or .xlsx).
6.
7.
8.
9.
10. Click OK to exit or Click Cancel to cancel the Design Note list creation.
You can customize the Design Note List Format from HyDraw Option.
Design Notes List
VEST, Inc.
HyDraw CAD900
127
Collate Files
VEST, Inc.
HyDraw CAD900
61
Collate Documents
62
128
2.
Select a single symbol or multiple symbols and then press the Enter key.
The Select Symbols prompt displays. The Collate Documents dialog box displays.
The Specify items included [Components/External Ports/Accessories/Include all/More options] <
Include All> prompt displays.
3.
b.
Click OK.
c.
d.
e.
f.
g.
h.
4.
VEST, Inc.
Select the appropriate folder or click Make New Folder to create a new folder at the appropriate
location for saving documents.
HyDraw CAD900
129
2.
Select a single symbol or multiple symbols and press the Enter key.
The Specify items included [Components/External Ports/Accessories/Include
all/More options] <Include All> prompt displays.
3.
b.
c.
Click OK.
d.
e.
f.
i.
g.
4.
VEST, Inc.
h.
i.
Click OK.
Select the appropriate folder or click Make New Folder to create a new folder
in the appropriate location for saving CAD files.
HyDraw CAD900
130
Calculator
63
VEST, Inc.
HyDraw CAD900
Unit Converter
131
2.
3.
4.
Click
to copy the To value
to the clipboard.
VEST, Inc.
HyDraw CAD900
132
MDTools Interface
64
VEST, Inc.
HyDraw CAD900
Export to MDTools
133
1.
2.
3.
VEST, Inc.
Export to MDTools
HyDraw CAD900
134
1. Manifold Properties
Configure following settings,
Material
Manifold Pressure
Note:
By default, the Design unit is displayed as
per the unit selection in HyDraw Options.
Engraving
Preferred Face
The Nets section displays Nets and Net
Information, Net Type and Net Pressure.
Mounting Hole
Select the required mounting hole option.
Export to MDTools
VEST, Inc.
HyDraw CAD900
135
Report
Click Report.
The Schematic report dialog box displays.
It contains the entire extracted data from
the HyDraw schematic.
Schematic Reports
VEST, Inc.
HyDraw CAD900
136
Export
Click Export.
The Save Input File dialog box displays.
Save the resulting XML file at the
desired location.
Note:
Information about CAD files linked to
the components is exported to
MDTools. Then, it automatically
assembles the component models on
the block.
VEST, Inc.
HyDraw CAD900
137
Convert
65
VEST, Inc.
HyDraw CAD900
Convert to HyDraw
138
2.
3.
Select an application.
VEST, Inc.
HyDraw CAD900
139
4.
Click Insert.
The Specify Port Insertion point
prompts display.
Click OK.
The Specify Insertion point prompts
display.
VEST, Inc.
HyDraw CAD900
140
Title Block
VEST, Inc.
HyDraw CAD900
66
67
141
2.
3.
Note:
By default, drawing units display as
per the unit selection in HyDraw Options.
VEST, Inc.
HyDraw CAD900
142
2.
3.
4.
Select a property.
Enter a value.
Click OK and exit.
The edited value is updated in the
inserted Title block.
Note:
Double-click to edit all the Title block
properties.
VEST, Inc.
HyDraw CAD900
143
FluidPowerTools.com
VEST, Inc.
HyDraw CAD900
68
69
70
Internet Settings
144
1.
The FluidPowerTools.com
Data Access Settings dialog
box displays.
2.
VEST, Inc.
HyDraw CAD900
145
Subscription Information
Know the HyDraw version and subscription information.
VEST, Inc.
HyDraw CAD900
146
2.
VEST, Inc.
HyDraw CAD900
147
3.
Terms of Usage
Navigate to FluidPowerTools.com, where you can see the terms and conditions of using the services on FluidPowerTools.com
VEST, Inc.
HyDraw CAD900
148
4.
Contact Info.
Navigate to FluidPowerTools.com, where you can find the contact information of the VEST team.
Click Services > Contact Info on the
FluidPowerTools section on the HyDraw
CAD ribbon menu.
VEST, Inc.
HyDraw CAD900
149
1. Internet Settings
Configure the Internet settings for FluidPowerTools.com.
1.
2.
3.
VEST, Inc.
HyDraw CAD900
150
VEST, Inc.
HyDraw CAD900
71
Help
72
About HyDraw
151
70. Help
Circuit Diagrams
The Circuit diagram command opens the
HyDraw CAD900 user manual.
VEST, Inc.
2D Drafting
The 2D Drafting command opens the 2D drafting help file
for HyDraw CAD900.
HyDraw CAD900
152
About HyDraw
Note:
In the Command line, type
LicenseInfo to get the license
information with Version Number,
Build number, Serial number and
License type details.
VEST, Inc.
HyDraw CAD900
153
VEST, Inc.
73
74
75
76
77
HyDraw CAD900
154
System Requirements:
The system requirements are provided in the product documentation.
Software
Hardware
Processor : 64-bit
Display Resolution : 1,024 x 768 display resolution with true color (1,600 x 1,050 with true color recommended)
Note:
The minimum required configuration is only listed above; however it is recommended to use a higher hardware configuration for power users.
VEST, Inc.
HyDraw CAD900
155
Software Installation
1.
2.
3.
4.
5.
Click Install.
View the HyDraw CAD User Manual and the Read Me file from the
Documentation section, if required.
6.
Once complete, click Finish in the HyDraw CAD900 dialog box and
restart your computer for the changes to take effect.
HyDraw CAD900 and HyDraw Library Manager are installed on the
system and HyDraw CAD900 is displayed in the Windows Start >
Program menu.
VEST, Inc.
HyDraw CAD900
156
2.
Alternatively select,
Start
> All Programs
> VEST
> HyDraw CAD900
> License Settings
The HyDraw CAD900 License
Manager dialog box displays.
3.
.
4.
Select Authorize HyDraw CAD900 or Try HyDraw CAD900 for 30 days trial period.
5.
Click Next.
8.
9.
Click Next.
Click Next.
VEST, Inc.
Authorization request is
generated and prompts to save
in an xml file.
HyDraw CAD900
157
5.
6.
Click Next.
7.
8.
Click Activate.
9.
Click Close.
The dialog box closes and HyDraw License is
successfully activated.
Alternatively select,
Start
> All Programs
> VEST
> HyDraw CAD900
> License Settings
The HyDraw CAD900 License Manager
dialog box displays.
4. Click the Activate button.
The HyDraw CAD900 Authorization
dialog box displays.
VEST, Inc.
HyDraw CAD900
158
7.
4.
Click Next.
9.
5.
6.
VEST, Inc.
HyDraw CAD900
Caution:
The transfer process will delete the license from the
computer.
159
1. Select,
Start
> All Programs
> VEST
> HyDraw CAD900
> License Settings
4. Click Apply.
VEST, Inc.
HyDraw CAD900
160
Migrate Settings
Migrate the HyDraw settings of old version to HyDraw CAD900.
1. Select,
Start
> All Programs
> VEST
> HyDraw CAD900
> Migrate HyDraw Settings
The HyDraw CAD900 Migrate Settings message box displays.
2. Click Yes to migrate old version of HyDraw settings to HyDraw CAD900 settings.
Note:
Migrate settings will override the existing settings.
Migrate Settings
VEST, Inc.
HyDraw CAD900
161
Export Settings
Export the existing HyDraw settings.
1. Select,
Start
> All Programs
> VEST
> HyDraw CAD900
> Export HyDraw Settings
The HyDraw CAD900 Export message box displays.
2. Click Ok to open the Browse folder.
3. Select the folder where you want to export all the HyDraw Settings files.
4. Click OK to save and exit.
Export Settings
VEST, Inc.
HyDraw CAD900
162
Import Settings
Import the HyDraw settings to the existing HyDraw settings.
1. Select,
Start
> All Programs
> VEST
> HyDraw CAD900
>Import HyDraw Settings
The Import HyDraw Settings message box displays.
2.
Click Yes.
The File Select dialog box displays.
VEST, Inc.
HyDraw CAD900
163
2.
3.
4.
5.
Click Browse
6.
7.
8.
Click OK.
All HyDraw Library paths are configured as selected.
Note:
All data paths shown are default.
You can configure to common network data paths.
HyDraw CAD library default paths
VEST, Inc.
HyDraw CAD900
164
1.
VEST, Inc.
HyDraw CAD900
165
2.
Proxy Connection
If your computer is connected to the Internet
through a web proxy server,
then select Use proxy server.
2.
3.
Note:
VEST, Inc.
HyDraw CAD900
166
2.
3.
VEST, Inc.
HyDraw CAD900
167
4.
5.
6.
VEST, Inc.
HyDraw CAD900
168
2.
3.
Select Application.
4.
5.
Click OK.
6.
7.
8.
Press Enter/Tab.
Add Symbol
VEST, Inc.
HyDraw CAD900
169
3.
1.
Edit Port
1.
Type the new name in the Name column and the optional
name in the Other Name column.
2.
3.
4.
Click OK.
The Name/Other name of the port displays with the symbol,
If both the names are selected, then dual port names are
displayed.
2.
Insert Port
1.
Type the new name in the Name column and the optional
name in the Other Name column.
2.
3.
VEST, Inc.
HyDraw CAD900
170
3.
Display Formats
1.
Click
2.
Click
to rotate right.
3.
Click
to rotate left.
4.
4.
Solenoid Information
1.
2.
3.
Click OK.
The modified symbol is updated in the library.
Note
VEST, Inc.
HyDraw CAD900
171
3.
4.
Press Enter/Tab.
5.
VEST, Inc.
HyDraw CAD900
172
4. Delete Symbol
Delete the master symbol available in the HyDraw Symbol Library.
In the HyDraw Library Explorer, browse to the required folder and
select the symbol to delete.
1.
2.
3.
Click Yes.
The symbol is deleted from the library.
Manage Symbol Delete Symbol
CAUTION:
The symbol once deleted, is permanently removed from the library
and cannot be retrieved.
VEST, Inc.
HyDraw CAD900
173
2.
3.
4.
5.
6.
Press Enter/Tab.
VEST, Inc.
HyDraw CAD900
174
2.
3.
4.
1.
Edit Port
1.
2.
3.
4.
Click OK.
2.
Insert Port
1.
2.
3.
VEST, Inc.
HyDraw CAD900
175
3.
Display Formats
1.
Click
2.
Click
to rotate right.
3.
Click
to rotate left.
4.
2.
3.
Click Yes.
VEST, Inc.
HyDraw CAD900
176
VEST, Inc.
HyDraw CAD900
177
Index
A
About HyDraw, 153
Accessories, 84
Actuation Chart, 26
Add Dwg Version, 173
Add New Display Format, 115
Add New External Ports, 175
Add New Symbol, 170
Align External Port Names, 100
Align Symbol Ports, 99
Align Symbols, 96
Annotations, 109
Application, 16
Authorize HyDraw CAD900, 158
C
Calculator, 131
Change Text Height, 110
Collate CAD Files, 130
Collate Documents, 129
Collate Files, 128
Command options, 34
Component Data Available, 147
Components, 84
Configure External Port, 50
Connect Ports and Symbols, 69
Connection Tab, 37
Contact Info, 149
Convert to HyDraw, 139
Copy Properties, 86
Create and Insert Hose List, 122
F
Fetch Pipe and Tube Data, 70
Flip Symbols, 98
D
Data Access Settings, 145
Delete a Symbol, 103
Delete Master Symbol, 177
Delete Symbol, 174
Design Notes, 28
Design Requirements, 77
Display Format, 41
Display Formats, 177
Dock HyDraw Property Manager, 12
Drawing Template, 42
VEST, Inc.
HyDraw CAD900
Gauge Port, 40
H
Help, 151, 152
Help for FluidPowerTools.com, 146
Hose List, 22
HyDraw CAD Ribbon Menu, 6
HyDraw Library Explorer, 8
HyDraw Options, 16
HyDraw Property Manager, 11
HyDraw Shortcuts, 7
HyDraw Startup, 5
I
Import Settings, 164
Insert Connection, 68
Insert Envelope, 65
Insert External Port, 48
Insert from Parts List, 62
Insert Gauge Port, 66
Insert Ports List, 120, 122
Insert Symbol, 44
Insert Symbol Port, 64
Insert Symbols, 43
Insert Terminators, 63
Insert Title Block, 142
Installation, 155
Installation & Setup, 154
Internet Setting, 150
Internet Settings, 35
178
Index
Introduction, 1
Item ID, 39
P
L
M
Make Connections, 67
Manage HyDraw CAD Drawings through Vault, 178
Match Connections, 73
MDTools Interface, 133
Merge Connections, 74
Migrate Settings, 162
Misc., 30
Model Data, 78
Move Symbol, 95
N
Net List, 27
O
Online Services, 166
Open HyDraw Property Manager, 12
VEST, Inc.
Parts List, 20
Port Data - Select from Library, 49
Ports List, 24
Proxy Connections, 167
Pump Motor Adaptor Data - Select from Library, 47
Purge Price Data, 92
Purge Property, 90
R
Reassign Hose ID, 113
Reassign Item ID, 112
Recreate Balloons, 114
Refresh Properties, 87
Replace External Port, 51
Reset Connections, 75
Rotate Property Text, 111
Rotate Symbols, 97
T
Terms of Usage, 148
Text Size, 30
Transfer Standalone License, 159
U
S
Search Components, 52
Search Sub-systems, 58
Selected Item, 13
Selected Item Properties, 77
Show/Hide Design Notes, 106
Show/Hide Port Name, 105
Show/Hide Properties, 89
Software Installation, 156
Solenoid Naming, 33
Specify Properties, 76
HyDraw CAD900
W
Workspace, 4
179
Index
VEST, Inc.
HyDraw CAD900
180