Reviewed by
Countersign
Zhang Chaoqun
Zhang Chaoqun
Standardization
Approved by
ZTE Corporation
Confidential
Update Record
No.
1
Version
V1.0
Drafted/
Draft/update
Reason for
updated by
Date
update
2011-07-26
Create
Zhang Chaoqun
Note 1: This form needs to be filled-in every time when you change the contents of an archived file (an
archived file refers to all files which have been sorted and archived at division level or company
level).
2: When it is the first time to archive a file, Reason for update, main updating points may leave
blank.
Confidential
Table of Contents
1
Confidential
1.1
Purpose
This document will clearly describe the current software release notes (hereafter called
the notes), including new features, data change, solved issues and known issues. It will
be taken as reference for outfield test when the release is upgraded.
1.2
Scope
1.3
Target Readers
Classification
Attention Points
Purchasers coordinators /
2 Brief Description
2.1
Release Background
2.2
Current Version
Previous Version
V4.09.21.14P01
V4.09.21.08P10
The related UTRAN version is U 9.3, and its feature is shown below:
Feature Restrictions
Key words
Attentions
MRR
UDP mux
Confidential
Robust Header
This feature is verified between RNS and Qualcomm Demo UE, but
Compression
ATM over E3
ZTE NODEB does not support this feature. This feature is verified
only between two RNCs, so its not released in this version.
ATM over T3
ZTE NODEB does not support this feature. This feature is verified
only between two RNCs, so its not released in this version.
IP over E3
ZTE NODEB does not support this feature. This feature is verified
only between two RNCs, so its not released in this version.
IP over T3
ZTE NODEB does not support this feature. This feature is verified
only between two RNCs, so its not released in this version.
ZTE NODEB does not support this feature. This feature is verified
only between two RNCs, so its not released in this version.
ZTE NODEB does not support this feature. This feature is verified
only between two RNCs, so its not released in this version.
ZTE Core Network does not support Multicast Mode. This feature is
verified by simulation, so its not released in this version.
2.3
Board
Applicable or not
eBBUB
CC
Applicable
BPC
Applicable
FS
Applicable
SA
Applicable
PM
Applicable
UBPG
Applicable
R8840
RTR
Applicable
R8860
DTR
Applicable
R8860E
ADTR
Applicable
R8880A
TRU
Applicable
RSU82
TRMFZ
Applicable
R8882
TRM24
Applicable
Board
Boot Version
Confidential
CC
10111 or above
BPC
4.00.100b or above
BPC MMC
10113 or above
FS
10111 or above
FS MMC
10113 or above
SA
10113 or above
PM
10113or above
UBPG
10101 or above
UBPG MMC
10113 or above
R8840
RTR
0x9 or above
R8860
DTR
0x4 or above
R8860E
ADTR
0x4 or above
R8880A
TRU
0x0 or above
RSU82
TRMFZ
2.0.10.P2B4 or above
R8882
TRM24
1.0.0P0T0 or above
The hardware environment of this software is based on ZTE RNC (V3) hardware
platform.
All software will be updated just like previous version did. The detail upgrade info is
shown as attached Table 1.
2.4
The compatibility of this version with other ZTEs NEs is listed as below:
RNCV3.09. OMCB
ZXSDR
30.09
V4.09.21.14P01
IBSCV6.20.614CP6
V4.09.21.14P01
CM Data Change
CM.xls
3.2
PM Data Change
PM.xls
Confidential
Alarms Change
AM.xls
3.4
New Features
Function No.
Name
Node BV40921034
of
function
Purpose or
It takes short time to detect a dry contact alarm. The alarm detection period will not exceed 9
Benefit
seconds.
Impact to end
user
Impact to the
operator
Involved
eBBUB
System
Description
The relevant codes are modified. Once a dry contact alarm occurs, it can be reported to
OMCB/LMT within 9s.
Function No.
Name
Node BV40921036
of
Purpose or
function
Benefit
Impact to end
user
Impact to the
operator
Involved
eBBUB
System
Description
Function No.
Node BV40921038
Name
of
function
Purpose or
The foreground power module can be monitored. If there is abnormity, a power alarm can be
Benefit
Impact to end
user
Impact to the
operator
Confidential
eBBUB
System
Description
Once B201 power gives an alarm, it can be reported to OMCB/LMT within 20 seconds.
Function No.
Node BV40921040
Name
of
FCE cascade
function
Purpose or
Benefit
Impact to end
FCE cascading mode is adopted to connect an auxiliary cabinet with BBUB when the auxiliary
user
cabinet is required, but there is no RC cabinet nearby or RC cabinet doesn't have enough
space for RSU.
Impact to the
The FCE cascading mode is adopted to connect an auxiliary cabinet with BBUB. Old devices
operator
can be put in the auxiliary cabinet, and the auxiliary cabinet provides the function to monitor
and manage temperature and dry contacts.
Involved
eBBUB
System
Description
When an operator reuses old devices such as battery and transmission devices, he wants
space for these old devices. However if a main cabinet doesn't have enough space for these
old devices, an auxiliary cabinet must be used. And the auxiliary cabinet must support the
function to monitor and manage temperature and dry contracts.
To manage the auxiliary cabinet, FCE management is the key issue. How to manage FCE, the
key point is to implement communication between FCE board and BBU-CC via a link.
FCE cascading mode is a solution to connect main cabinet to auxiliary cabinet.
Function No.
Name
Node BV40921042
of
function
Purpose or
This function enables a maintenance operator to scan receiving spectrum of RRU's duplexer
Benefit
within operating band, analyze the spectrum to find interference source. It supports GSM,
UMTS and hybrid GU modes.
The purpose of PIM test is to detect the quality of RRU's antenna.
Benefits: The maintenance operator needn't approach RRU site. What he can do is to stay at
an equipment room and visit BBU via EDMS. The EDMS provides a function for him to view
receiving spectrum and PIM test sitaution within RRU's operating band. After analysis, he can
detect and solve interference and antenna problems.
The spectrum scanning precision is 20KHz bandwidth.
Receiving signal sensitivity is high (-130 to -50dBm@20KHz).The uplink signals within the
scaning range can even be detected.
Impact to end
user
Impact to the
operator
Confidential
eBBUB/RRU
System
Description
Working principle is described as follow: change the receiving center frequency of RRU, sample
IQ data and report the sampled IQ data to LMT. LMT adopts fourier transform algorithm to
calculate energy value of every 20KHz bandwidth. Based on the calculated energy, LMT draws
receiving spectrum of a duplexer within operating band.
Function No.
Name
Node BV40921044
of
function
Purpose or
Benefit
Impact to end
user
Impact to the
operator
Involved
eBBUB/OMCB/LMT/R8882
System
Description
In GU co-band scenario, UMTS carrier bandwidth is reduced from 5MHz to 4.2MHz, leaving a
certain frequency range to GSM. The purpose is to save frequency resources.
Function No.
Name
Node BV40921046
of
function
Purpose or
RSU82 only supports 4.8M and 5.0M carrier bandwidth in prevrious release. It can support
Benefit
4.2M, 4.4M and 4.6M carrier bandwidth in 4.09.21.14P01. The purpose is to improve frequency
using efficiency.
Impact to end
user
Impact to the
A maintenance operator can configure RSU82 with 4.2M, 4.4M and 4.6M carrier bandwidthvia
operator
OMCB/LMT.
Involved
eBBUB/OMCB/LMT/RSU82
System
Description
RSU82 only supports 4.8M and 5.0M carrier bandwidth in prevrious release. It can support
4.2M, 4.4M and 4.6M carrier bandwidth in 4.09.21.14P01.
Function No.
Name
Node BV40921048
of
function
Purpose or
Originally outdoor BS8900A is designed to support one RC8910 cabinet. This configuration
Benefit
cannot meet market requirement. Two RC8910 cabinets should be supported for the
configuration of more than 6 RSUs.
Confidential
user
Impact to the
When more than 6 RSUs are configured for a BS8900A site, 2 RC8910 cabinets are required to
operator
Involved
OMCB/LMT
System
Description
Function No.
Name
Node BV40921050
of
function
Purpose or
Benefit
Impact to end
user
Impact to the
operator
Involved
eBBUB/OMCB/LMT
System
Description
In single GSM mode, single channel allows 6-carrier configuration. But total power per
channel shouldnt exceed 60W.
Function No.
Name
Node BV40921052
of
function
Purpose or
Benefit
Impact to end
user
Impact to the
operator
Involved
eBBUB/OMCB/LMT
System
Description
Single RSU82 module supports 900MHz 1T2R and 1800MHz 1T2R mode (2T4R in total),
supporting 3GPP GSM/EDGE frequency bands, FDD duplex mode, downlink:
925MHz~960MHz, uplink: 880MHz915MHz.
Supporting 1800MHz band, FDD duplex mode, downlink band: 1805MHz~1880MHz, uplink
band: 1710MHz~1785MHz. At first stage, PGSM+1800 low-frequency-band duplexer and
900MHz/1800MHz full-frequency-band duplexer are developed.
Function No.
Node BV40921054
of
Confidential
function
Purpose or
In some CSL sites, the primary antenna works in this way: TxRx port only uses
Benefit
Impact to end
user
Impact to the
operator
Involved
eBBUB/OMCB/LMT
System
Description
Make proper configuration in OMCB/LMT, then the TxRx receiving signals can be screened.
This function brings two benefits: reduced interference in partial POI sites and increased
index.
Function No.
Name
Node BV40921056
of
LMT uses default path to open or save configuration data. The default path actually is used
function
Purpose or
The file path, which is used by an LMT user during previous operation, is taken as default path
Benefit
Impact to end
user
Impact to the
An Open or Save box has an item of file path. This item shows previous operation path in
operator
default.
Involved
LMT
System
Description
During previous operation, a file path is used to open or save an entire table. This file path is
recorded for next operation. When a user wants to open or save an entire table again, the
default path shows the previous file path.
Function No.
Name
Node BV40921058
of
function
Purpose or
If the temperature in an auxiliary cabinet is too high or too low, an alarm should be reported.
Benefit
The purpose is to monitor the working environment of a microwave or a 3rd party device.
Impact to end
user
Impact to the
A maintenance operator can set high temperature limit and low temperature limit for a
operator
Involved
eBBUB
System
Confidential
A temperature alarming function must be added for an auxiliary cabinet. The purpose is to
monitor the working environemnt of a microwave or a 3rd party device and to guarantee
suitable working temperature for devices. The alarming function reports high temperature alarm
and low temperature alarm with default limits being 55oC and -20oC respectively. Of course,
the two limits can be changed from OMCB/LMT. The temperature of an auxiliary cabinet is
sensed from FCE5 air outlet because this temperature is equivalent to environmental
temperature of the cabinet. When the sensed temperature exceeds high temperature limit, a
high-temperature alarm is reported. However when the sensed temperature is lower than low
temperature limit, a low-temperature alarm is reported. In other case, the alarm is recovered.
Function No.
Name
Node BV40921060
of
function
Purpose or
When more than one rectifier has a communication problem, power supplying capability is
Benefit
Impact to end
user
Impact to the
operator
Involved
eBBUB/OMCB/LMT
System
Description
Once two or above rectifiers of B900 and B121 have a communication problem, an alarm can
be reported to OMCB/LMT in about 20 seconds.
3.5
Optimized Features
None
3.6
Solved Issues
Node_SDR V40900062
Symptoms
When a cell enters smart power down mode, the corresponding RRU reports an
zero-digital-power alarm.
Impact
to
end
to
the
user
Impact
operator
Analysis
When a cell stays in the status of smart power down, this cell doesn't consume
digital power. And RRU reports a zero-digital-power alarm according to previous
judgement policy. Indeed, this alarm should be screened.
Confidential
If RRU detects that digital power is zero, it first checks the cell status. Then based
Solution
on the cell status, it decides whether to report this zero-digital-power alarm or not.
Involved System
RRU
Node_SDR V40900064
Symptoms
Impact
to
end
to
the
user
Impact
operator
During the DPD training step, the NCO is occasionally written to zero by mistake. It
Analysis
will cause the DL frequency to be 40kHz less than it should be, which leads to UE
unaccessible.
Solution
Involved System
R8860E
Node_SDR V40900066
Symptoms
BS8906 reports a sensor alarm with alarm subcode being RSU air outlet sensor.
This sensor alarm shouldn't be reported if the No. 5 fan is not configured in FCE3,
that is, the relevant sensor alarm should be screened if RSU rack is not configured
in BS8906 cabinet.
Impact
to
end
A sensor alarm is given even though RSU rack and fan are not configured.
to
the
user
Impact
operator
If a configuration item doesn't exist, its relevant sensor shouldn't give an alarm.
Analysis
Solution
being reported.
Involved System
eBBUB
Node_SDR V40900068
Symptoms
Impact
to
end
to
the
When BS8906 is used ourdoor, RSU is not configured. However, RSU is configured
user
Impact
operator
Confidential
OMCB/LMT adopts slot object to denote slot information, Pluginunit object to denote
Analysis
board information. In order to draw rack layout, the slot object has the same life
cycle as rack associated object. For this reason, slot object cannot be deleted.
Modify BS8906 main cabinet. Change the BC cabinet to be BC cabinet and
Solution
RC8906 cabinet, i.e. put RSU into RC8906 cabinet. Do not create RC8906 cabinet
unless RSU needs to be configured.
Involved System
3.7
1.
2.
3.
4.
5.
6.
7.
8.
OMCB/LMT
Known Issues
In ATM working mode, master/slave changeover only supports cold changeover, not
hot changeover.
PMS performance measurement shows only the result of samples so that
measurement time may be discontinuous.
Current release doesnt support MBMS for the moment.
To switch from IPOE1 mode to ATMOE1, operation sequence must be: first delete
PPP; then reset single board; at last configure ATM mode. If not following the
sequence, there may be some problems. For example, single board may reset, or
transport link may be interrupted.
Up to 20 IP parameters can be configured.
If either rack name or Node B description contains a special character like &, LMT
cannot be accessed after Node B reset.
RSU82 has unstable DPD performance, which causes downlink index to exceed
standard level. It is not recommended to use this version in RSU82 900M, 1800M
and 2.1G.
Address abnormity happens during master/slave changeover operation. This
possibility is very small. Once it happens, QE is hung and transmission is
interrupted.
3.8
3.8.1
When upgrading from previous to the current version, it will break current voice call and
PS session for a while. After the version is uploaded, the time of version switching will be
controlled in 15 minutes. So ZTE recommends the upgrading should be done in the
lowest traffic phase.
Please refer to ZTE WCDMA Node B Software Updating Guide, eBBUB, from
V4.09.21.08 to V4.09.21.14
3.8.2
Step
SW Loading Timeline
Task
Item
Main
Confidential
Preparation
upgrade
time(minute)
upgrade
time(minute)
influenc
e
30
30
NO
60
NO
15
NO
Data upgrade
20
NO
NO
OMM upgrade
3
4
Node B upgrade
software warehouse
6
20
10
NO
15
15
YES
120
60
NO
Test
and
verification
3.8.3
Step
Task
Preparation
Item
NO
25
NO
13
NO
Data upgrade
20
NO
NO
OMM upgrade
3
4
Node B upgrade
software warehouse
6
NO
15
15
YES
120
60
NO
Test
and
verification
4 Attachment
4.1
Logical
CPU
CPU Ver.
Microcode Ver.
DSP Ver.
CC
8360
V4.09.21.14P01
V4.09.21.14P01
V4.09.21.14P01
FS
8313
BPC
8378
SA
LPC2138
Board
LPC2138
FCE
LPC2138
PM
LPC2138
RTR
MPC852
TRU
MPC852
TRMFZ
MPC852
TRM24
MPC852
Confidential
*Each of the above board has unique and fixed hardware configuration including CPU power and
memory