Sunteți pe pagina 1din 33

CAT- Nestl

Automation, Electrical and


Instrumentation components

External
DKS/2014-04-15

CAT- Nestl
Automation and Electrical Components

External
DKS/2014-04-15

Course Content
Automation and electrical components

Overview

Low voltage equipment

Frequency converter

Control system

Operator panel

Recorders

Communication equipment

/3

Automation and electrical components


Overview
AUTOMATION & ELECTRICAL COMPONENTS
ABB

Beijer
Electronics

Danfoss

IFM

Phoenix
contact

Rockw ell
automation

Sartorius

Low voltage equipment

Frequency converters

PLC systems

Recorders

Controllers

Operator panels

Weighing systems

Netw ork equpment


Field equipment

Siemens

x
x
x

/4

Automation and electrical components


Low voltage equipment

Selected global supplier

Example of usage

Equipment for electrical cabinets

Contactors

Electrical protection equipment

Fusing equipment

Siemens benefits

Siemens is a demand from many customers.

The products have a competitive price (for TP).

The products are modern a have a high quality.

World-wide representation of Siemens.

/5

Automation and electrical components


Frequency converters

Selected global supplier

Now in NEMA 4X enclosures for Tetra Pak

Example of usage

Control of centrifugal pumps

Control of homogenizer speed

Soft start of separators

FC 300 benefits

The drives are available in Nema 1 (IP21) and Nema 4X (IP66).

The drives are very compact.

The drives can be provided with fieldbus boards,


Profibus-DP, DeviceNet.

The drives are backwards compatible with VLT-drives.

The drives can be configured with MCT 10 software.

FC 302 drives have safe stop as a standard.

World-wide representation of Danfoss.


/6

Automation and electrical components


Frequency converters

How to select the correct frequency converter

Choose protection class IP20/21/NEMA 1 or IP66 /NEMA 4X.

Choose mains voltage: 3x200-240 V, 3x380-480/500 V or 3x525-600 V.

Choose frequency converter type FC 301 (basic) or FC 302,


(advanced tasks or long motor cables > 50 m and < 150 m)

Choose type of filter:


- A1/B, fulfils EMC demands and Tetra Pak Corporate Standard
- A2, (no RFI-filter) for certain applications

Choose add-ons: fieldbus, brakes, or other.

Select the frequency converter with correct power rating for the motor.
A frequency converter should be dimensioned according to the nominal
motor current, but it is also necessary to consider the relevant load

/7

Automation and electrical components


PLC control systems

Selected global suppliers

Plants & lines


S7-400

Modules
S7-300

Example of usage

Process control

/8

Automation and electrical components


Operator panels

Selected global suppliers

Example of usage

Process module panels

Local control panels

E1000/Tetra Pak

Tetra Pak design

Windows CE

6, 10 and 15 Touch

IP66, hygienic design

24 V DC

ECCN=5D002

E-Designer free of charge

/9

Automation and electrical components


Recorders

Selected global suppliers

Graphical recorders and paper recorders

Example of usage

Registration of process data

Indication of process data

Temperature control

Pressure control

E1000/Tetra Pak

Tetra Pak design

Windows CE

6, 10 and 15 Touch

IP66, hygienic design

24 V DC

ECCN=5D002

E-Designer free of charge

Graphical Recorders

Paper Recorders
/ 10

Automation and electrical components


Communication equipment

Selected global suppliers

Example of usage

Unmanaged Ethernet switches

Managed Ethernet switches

Telephone modems

Ethernet patch panels and connectors

Ethernet patch cables

Profibus-connectors

/ 11

CAT- Nestl
Instrumentation Components

External
DKS/2014-04-15

Course Content
Instrumentation components

Overview

Flow meters

Level meters

Pressure meters

Analyzing components

Temperature meters

Weighing systems

/ 13

Instrumentation components
Overview
Endress
+Hauser
Flow meters
Magnetic flow meters
Mass flow meters
Level
Level switches
Capacitive level meter

Sartorius

To be
decided

x
x
x

Radar level meter

Pressure meters
Pressure gauges

Pressure transmitters

Pressure switch

Differential pressure transmitters

Temperature
Temperature sensors

x
x

Analyzing
Conductivity meters

PH measurement

(x)

Weighing
Load cell and transmitter

Pentronic

Hydrostatic pressure

Temperature transmitters

ABB

x
/ 14

Instrumentation components
Flow meters- Variable area

Selected global suppliers

Example of usage

Measuring flow in water pipes and sugar solutions

ABB Variable area flowmeters

Possible to use without wiring.

Possible to use in non-conductive media.

Simple to use instrument for indication measurement (5%)

Analogue output is possible to order

/ 15

Instrumentation components
Flow meters-Volumetric

Selected global suppliers

Example of usage

Measuring flow in product pipes

Measuring flow in water pipes

Technical information

Dimensions: DN 2 to 100
(Measuring range at 2,5m/s 1 to 72.000l/h)

Temperature range: -20 C to +150 C

Accuracy: 0.5% (option 0.2%)

Display for programming

Communication: Hart, Profibus PA/DP

Designed according to 3A and EHEDG

Welded process connection

Compact or remote version


/ 16

Instrumentation components
Flow meters-mass

Selected global suppliers

Example of usage

Measuring mass flow in product pipes

Measuring product density

Measuring Brix value

Technical information

Dimensions: DN 8 to 100

(Flow rate 400 to 70.000 kg/h at circa 2 m/s)

Temp.range: -20 C to +200 C

Accuracy density: Down to 0.00025 g/cm3

Accuracy brix: Down to 0.1 brix

Accuracy viscosity: 5% 0.5cP

Material: 316L, Titanium or Hastaloy

/ 17

Instrumentation components
Level -switches

Selected global suppliers

Example of usage

Indication when no product in line,


stop of filling machine

Indication when a tank is empty


or full (overfill protection)

/ 18

Instrumentation components
Level vibrating forks

Selected global suppliers

Benefits

No calibration

quick, low-cost start-up

No mechanically moving parts

no maintenance

no wear

Suitable for all liquids

/ 19

Instrumentation components
Level meters

Selected global suppliers

Example of usage
Level metering in header batch (dosing vessel)
Suitable for level measurement in vessel
with products of conductivity of >100S/cm
Be careful to use when foam is present
Note:
Be aware of slow reaction when
quick temperature changes occur
Not suitable for level measurement in vessels with multiple products

/ 20

Instrumentation components
Level meters

Selected global suppliers

Example of usage

Level metering in header batch (dosing vessel)

Suitable for level measurement in vessel


with products of conductivity of >100S/cm

Be careful to use when foam is present

/ 21

Instrumentation components
Level Guided radar

Selected global suppliers

Example of usage

Less sensitive for surface conditions


like foam and turbulences

Insensitive for product changes

Easy set-up

Dead zone at end of pipe

Slow reaction of changes

/ 22

Instrumentation components
Pressure meters-gauges

Selected global suppliers

Example of usage

Supervision of pressure in pipe systems

Supervision of pressure in pressure tanks

/ 23

Instrumentation components
Pressure meters-transmitters

Selected global suppliers

Example of usage

Supervision of pressure in pipe systems

Control of pressure in pressure tanks

Control of level in pressure tanks

/ 24

Instrumentation components
Pressure meters-differential pressure

Selected global suppliers

Example of usage

Level in vacuum chamber like in VTIS or milk de-aerator

Measuring of differential pressure in a milk pasteurizer to ensure higher


pressure on treated milk side

/ 25

Instrumentation components
Pressure switches

Selected global suppliers

Example of usage

Switching off steam when low water pressure

Alarm at low pressure inlet milk tank

/ 26

Instrumentation components
Analyzing components-conductivity

Selected global suppliers

Example of usage
Control of CIP concentration

/ 27

Instrumentation components
Analyzing components-pH

Selected global suppliers

Example of usage
In-line control of PH value

/ 28

Instrumentation components
Temperature-sensors/transmitters

Selected global suppliers

Pentronic, E& H

Example of usage
Supervision of temperature
Converting Pt100 resistance to mA signal
Normally mounted inside a panel

Special connection:
Pentronic

Tank connection:
E+H

/ 29

Instrumentation components
Weighing systems-hygienic load cell, transmitters

Selected global suppliers

Example of usage
Level indication in tanks
Weighing of tanks (mixing)
minimised horizontal surfaces
self draining design
no slots, no unsealed metal-to-metal contacts

/ 30

Instrumentation components
Weighing systems

Weighing application in Tetra Albatch

Weighing system
Weight indicator
4 -20 mA / Fieldbus

Load transmitter
(Weighing amplifier)
1 x 2mV/V

Junction box
4 x 2mV/V

4 Load sensors
(Loadcell)

/ 31

Instrumentation components
Weighing systems

Weighing application in Tetra Alsafe

PR6251 LAC active load cell 4-20 mA signal

/ 32

Restricted
JKO/2012-06-06

/ 33

S-ar putea să vă placă și