Documente Academic
Documente Profesional
Documente Cultură
12NDF155
Model:
The Acme F range of front access VRLA batteries has been specifically
designed for applications using 19" and 23" cabinets, especially telecoms.
Reliability is assured with the patented post seal and a state-of-the-art AGM
design developed to comply with the latest IEC, British and Telcordia
standards. A 12+ years design life and centralised venting system
add to the suitability and flexibility of this superior range.
Dimensions-mm[inch]
Specifications
Battery Model
12NDF155
12V
Nominal Voltage
Rated Capacity
Typical Weight
52.5kg
Internal Resistance
Approx 4.27m
O
Operation ( maximum )
-40 C to 50 C( -40 F to 122 F)
O
O
O
O
Operation ( recommended ) 15 C to 25 C( 59 F to 77 F
O
O
O
O
Storage
-20 C to 40 C( -4 F to 104 F)
Temperature Ranges
2.25V/cell@25 OC (77 OF )
Float Voltage
Recommended Maximum
Charging Current Limit
38.75A
2.35V~2.40V/cell@25 OC (77 OF )
The residual capacity is above 90% after 90 days storage(25 OC /77 OF )
Self Discharge
Terminal
M6 Female
8 1. 0Nm
Container Material
1.60V
1.67V
1.70V
1.75V
1.80V
1.83V
1.85V
5MIN
507
476
472
433
389
371
347
15MIN
30MIN
45MIN
273
263
258
250
233
214
207
165
162
160
159
152
149
138
120
119
118
117
112
109
104
1HR
2HR
3HR
4HR
5HR
6HR
8HR
96.8
96.2
95.5
94.1
91.6
87.6
84.9
59.5
59.2
58.8
57.4
56.9
56.2
54.3
40.2
39.5
39.3
38.8
38.6
37.3
36.3
33.3
33.2
33.0
32.6
32.5
31.0
30.6
29.1
28.9
29.5
29.0
28.2
27.3
26.7
25.1
25.0
25.0
24.8
24.3
23.5
23.0
19.5
19.3
19.3
19.1
19.0
18.5
17.9
1.60V
1.67V
1.70V
1.75V
1.80V
1.83V
1.85V
5MIN
848
816
811
757
695
663
621
15MIN
30MIN
479
470
465
461
436
400
390
299
296
296
295
288
284
264
45MIN
225
223
223
222
217
211
202
10HR
16.1
15.8
15.9
15.8
15.6
15.0
14.9
12HR
20HR
13.7
13.5
13.4
13.4
13.3
12.6
12.7
8.48
8.41
8.39
8.37
8.29
8.27
8.11
24HR
7.09
7.02
7.02
7.02
7.00
6.89
6.83
1HR
2HR
3HR
4HR
5HR
6HR
8HR
10HR
12HR
20HR
24HR
182
181
180
178
177
170
165
105
104
104
104
103
102
98.6
76.5
75.5
75.5
74.7
74.5
72.8
70.8
64.0
63.9
63.6
63.6
63.4
61.1
60.3
55.8
55.7
56.9
56.3
55.0
53.8
52.5
48.3
48.3
48.3
48.2
47.7
46.3
45.4
37.9
37.5
37.5
37.1
37.0
36.7
35.5
31.1
30.9
30.7
30.6
30.5
29.7
29.5
26.4
26.2
26.0
26.0
25.9
25.1
25.2
16.8
16.7
16.7
16.7
16.7
16.6
16.3
14.1
14.1
14.0
14.0
14.0
13.9
13.8
www.naradabattery.com
Discharge Voltage(V)
13
12
11
0.25CA
0. 6CA
1CA
Charge Characteristic
0.05CA
0. 1CA
10
Charge
Current
Charge
Capacity
Model:
80
0.20
60
0.15
40
0.10
20
0.05
13
100%Charge
12
30
60
Min
10
20
12
50%Charge
11
Charge
Current
10
12
Time(hour)
13.5
100
Capacity(%)
OCV (V)
13.0
12.5
12.0
75
10 C(50 F)
50
40 OC (104 OF)
30 OC (86 OF)
20 C(68 F)
25
11.5
10
20
30
40
50
60
70
80
90
12
100
18
21
24
27
Storage Time(month)
Remained Capacity(%)
Charging Procedures
15
Application Temperature
Cycle
25 OC
Set
Point
Allowable
Range
2.40
2.35~2.40
Max.
Charge
Current
0.25C
Standby
25 OC
2.25
Final
Discharge
Voltage
V/Cell
1.80
1.70
1.55
1.30
Discharge
Current (A) 0.2C(A) 0.2C<(A)<0.5C 0.5C<(A)<1.0C (A)>1.0C
2.23~2.27
12NDF155- 03-N-EN (Ver.03 July 2012) Subject to revision without prior notice. E. & O. E.
11.0