Sunteți pe pagina 1din 2

stored energy solutions for a demanding world

12NDF155

Model:

The Acme F range of front access VRLA batteries has been specifically
designed for applications using 19" and 23" cabinets, especially telecoms.
Reliability is assured with the patented post seal and a state-of-the-art AGM
design developed to comply with the latest IEC, British and Telcordia
standards. A 12+ years design life and centralised venting system
add to the suitability and flexibility of this superior range.

Dimensions-mm[inch]

Specifications
Battery Model

12NDF155

12V

Nominal Voltage

155Ah (10 hour rate) to 1.80V/cell @25 OC (77 OF )

Rated Capacity
Typical Weight

52.5kg

Internal Resistance

Approx 4.27m
O

Operation ( maximum )
-40 C to 50 C( -40 F to 122 F)
O
O
O
O
Operation ( recommended ) 15 C to 25 C( 59 F to 77 F
O
O
O
O
Storage
-20 C to 40 C( -4 F to 104 F)

Temperature Ranges

2.25V/cell@25 OC (77 OF )

Float Voltage
Recommended Maximum
Charging Current Limit

38.75A

Equalize and Cycle Service

2.35V~2.40V/cell@25 OC (77 OF )
The residual capacity is above 90% after 90 days storage(25 OC /77 OF )

Self Discharge
Terminal

M6 Female

Terminal Hardware Torque

8 1. 0Nm

Container Material

ABS (V0 optional)

Constant Current Discharge Characteristics Units: Amperes (25OC, 77OF)


End voltage
per cell

1.60V
1.67V
1.70V
1.75V
1.80V
1.83V
1.85V

5MIN

507
476
472
433
389
371
347

15MIN

30MIN

45MIN

273
263
258
250
233
214
207

165
162
160
159
152
149
138

120
119
118
117
112
109
104

1HR

2HR

3HR

4HR

5HR

6HR

8HR

96.8
96.2
95.5
94.1
91.6
87.6
84.9

59.5
59.2
58.8
57.4
56.9
56.2
54.3

40.2
39.5
39.3
38.8
38.6
37.3
36.3

33.3
33.2
33.0
32.6
32.5
31.0
30.6

29.1
28.9
29.5
29.0
28.2
27.3
26.7

25.1
25.0
25.0
24.8
24.3
23.5
23.0

19.5
19.3
19.3
19.1
19.0
18.5
17.9

Discharge Data with Constant Power


End voltage
per cell

1.60V
1.67V
1.70V
1.75V
1.80V
1.83V
1.85V

5MIN

848
816
811
757
695
663
621

15MIN

30MIN

479
470
465
461
436
400
390

299
296
296
295
288
284
264

45MIN

225
223
223
222
217
211
202

Copyright Narada Power Source Co.,Ltd.

10HR

16.1
15.8
15.9
15.8
15.6
15.0
14.9

12HR

20HR

13.7
13.5
13.4
13.4
13.3
12.6
12.7

8.48
8.41
8.39
8.37
8.29
8.27
8.11

24HR

7.09
7.02
7.02
7.02
7.00
6.89
6.83

UnitsWatts per cell (25 C, 77 F)

1HR

2HR

3HR

4HR

5HR

6HR

8HR

10HR

12HR

20HR

24HR

182
181
180
178
177
170
165

105
104
104
104
103
102
98.6

76.5
75.5
75.5
74.7
74.5
72.8
70.8

64.0
63.9
63.6
63.6
63.4
61.1
60.3

55.8
55.7
56.9
56.3
55.0
53.8
52.5

48.3
48.3
48.3
48.2
47.7
46.3
45.4

37.9
37.5
37.5
37.1
37.0
36.7
35.5

31.1
30.9
30.7
30.6
30.5
29.7
29.5

26.4
26.2
26.0
26.0
25.9
25.1
25.2

16.8
16.7
16.7
16.7
16.7
16.6
16.3

14.1
14.1
14.0
14.0
14.0
13.9
13.8

www.naradabattery.com

stored energy solutions for a demanding world


12NDF155

Terminal Voltage(V) Vs. Discharge Time (25OC, 77OF)

Discharge Voltage(V)

13
12
11
0.25CA
0. 6CA
1CA

Charge Characteristic

(%) (CA) (V)


Constant Charge At 0.20CA-14.1V(25)
120
Charge
Charge
Capacity
14 Voltage
100

0.05CA
0. 1CA

10

Charge
Current

Charge
Capacity

Battery Voltage Vs. Charge Time


Charge
Voltage

Model:

80

0.20

60

0.15

40

0.10

20

0.05

13
100%Charge

12

30

60

Min

10

20

12

50%Charge

11
Charge
Current

10

12

Time(hour)

Relationship of OCV Vs. State of Charge

Capacity Retention Characteristic

13.5

100

Capacity(%)

OCV (V)

13.0

12.5

12.0

75

10 C(50 F)

50
40 OC (104 OF)

30 OC (86 OF)

20 C(68 F)

25
11.5

10

20

30

40

50

60

70

80

90

12

100

18

21

24

27

Storage Time(month)

Remained Capacity(%)

Charging Procedures

15

Discharge Current VS. Discharge Voltage

Charge Voltage (V/Cell)

Application Temperature

Cycle

25 OC

Set
Point

Allowable
Range

2.40

2.35~2.40

Max.
Charge
Current

0.25C
Standby

25 OC

2.25

Final
Discharge
Voltage
V/Cell

1.80

1.70

1.55

1.30

Discharge
Current (A) 0.2C(A) 0.2C<(A)<0.5C 0.5C<(A)<1.0C (A)>1.0C

2.23~2.27

NARADA POWER SOURCE CO.,LTD.


9F, Building A, No. 50 Zijinghua Road, Hangzhou, China
Tel:+86-571-28827013
Fax:+86-571-28828290
Website:www.naradabattery.com E-mail: intl@narada.biz

NARADA ASIA PACIFIC PTE.LTD.


65 Ubi Crescent #07-05 Hola centre, Singapore
Tel: +65-6848 1191 Fax: +65-6749 3498
E-mail: sales@narada.com.sg

NARADA EUROPE (UK) LIMITED


Spectrum House, Dunstable Road, Redbourn,
St. Albans, Herts AL3 7PR
Tel: +44 (0)845 371 7095 Fax:+44 (0)845 612 2031
E-mail: sales@naradaeurope.com

12NDF155- 03-N-EN (Ver.03 July 2012) Subject to revision without prior notice. E. & O. E.