Sunteți pe pagina 1din 3

Pgina 1de 3

ALCANCE DE ACREDITACIN
COGUANOR NTG ISO/IEC 17 025, 1 revisin

FQB Laboratorios
Laboratorio de Anlisis
Contactos;
Licenciada Luisa Fernanda Barrientos
Licenciada Rina Orellana
Direccin: Carretera a Canalitos 21-96 Zona 17, Lomas del Norte, Guatemala
Telfono: (502) 2256-4117
Cdigo de Acreditacin: OGA-LE-018-07

Acreditado desde: 2007-06-11


Vigencia de la Acreditacin: 2016-03-07

Ensayo

Mtodo de Referencia

Recuento aerbico
en placa

Compendium of Methods for


the Microbiological
Examination of Foods, 4 ed.
2001, metodologa cap. 7 y cap.
6 numeral 6.33, pg. 54-58.
Compendium of Methods for
the Microbiological
Examination of Foods, 4 ed.
2001, metodologa 8.73, pg.75

Alimentos, UFC/g o ml
Superficies (segn sea el
caso)

<10-1*108
UFC/g o ml
(segn sea el
caso)

Alimentos, UFC/g o ml
Superficies (segn sea el
caso)

<10-1*108
UFC/g o ml
(segn sea el
caso)

Compendium of Methods for


the Microbiological
Examination of Foods, 4 ed.
2001, metodologa 8.71, 8.72,
8.81, 8.91, pgs. 75 y 76.

Alimentos

<3 a >1100
NMP/g o ml

Recuento de
coliformes totales
con VRB para
coliformes no
estresados ni
daados
Prueba presuntiva
para coliformes;
prueba
confirmatoria para
coliformes; prueba
para coliformes
fecales con caldo
EC; prueba
completada para
E. coli
Prueba para
confirmacin de
Escherichia coli

Matriz

Compendium of Methods for


Alimentos,
the Microbiological
Superficies
Examination of Foods, 4 ed.
2001, metodologa 8.92,
pg.76-77.
Tcnica estndar de Standard Methods for the
Agua
fermentacin por Examination of Water and
Potable y
tubos mltiples
Waste Water, mtodo 9221 B,
Aguas
a
para coliformes
C, E, F, 21 edicin, 2005, pg. Residuales
totales, fecales y
9-49 a 9-59.
Escherichia coli en
agua

Unidades

NMP/g o ml
(segn el
caso)

Rango

Positivo
Negativo

mg/L

<1,1 a >23
NMP/100 ml
(aguas
tratadas)
<2 a >1600
NMP/100 ml
(aguas sin

Pgina 2de 3
Ensayo

Mtodo de Referencia

Matriz

Unidades

Rango
tratar)

Slidos totales
secados entre 103 a
105 C.
Slidos totales en
suspensin secados
entre 103 a 105 C.

Agua
Potable y
Aguas
Residuales
Mtodo 2540 D Standard Methods
Agua
for the Examination of Water and
Potable y
Waste Water.
Aguas
21 a edicin, 2005, pgs. 2-58.
Residuales
Mtodo 2540 B Standard Methods
for the Examination of Water and
Waste Water.
21 a edicin, 2005, pgs. 2-56.

Slidos
sedimentables
Mtodo volumtrico

mg/L

2,5- 200 mg
de residuo

mg/L

2,5- 200 mg de
residuo

Mtodo 2540 F Standard Methods


for the Examination of Water and
Waste Water. 21a edicin, 2005,
pg. 2-59 y 2-60.
Demanda bioqumica Instructivo de Merck.
de oxgeno (DBO).
Instrumentos para medir demanda
Mtodo
biolgica de oxgeno. Lnea
respiromtrico
Oxitop para DBO. W.T.W.
(Anlogo a mtodo 5210 D
Standard Methods for the
Examination of Water and Waste
Water. 21 a edicin, 2005, pgs. 510 a 5-13.
Demanda qumica de Mtodo Spectroquant DQO
oxgeno (DQO).
1.14555.0001 Merck. (500 a
Reflujo cerrado,
10,000 mg/L de DQO)
mtodo colorimtrico Mtodo Spectroquant DQO
1.14541.0001 Merck. (25 a 1500
mg/L de DQO)

Aguas
Residuales

ml/L

0,1-1000 ml/L

Aguas
Residuales

mg/L

20- 4000 mg/L

Aguas
Residuales

mg/L

500 a 10000
mg/L

Aguas
Residuales

mg/L

25 a 1500 mg/L

Mtodo Spectroquant DQO


1.14690.0001 Merck. (50 a 500
mg/L de DQO)
(Los procedimientos son anlogos
al mtodo 5220 D Standard
Methods for the Examination of
water and Waste Water. 21 a
edicin, 2005, Pgs. 5-18 y 5-19.
Mtodo 4500-H+ B Standard
Methods for the Examination of
water and Waste Water. 21 a
edicin, 2005, Pgs. 4-90 a 4-94.

Aguas
Residuales

mg/L

50 a 500 mg/L

---

0 a 14

Potencial hidrgeno
(pH) mtodo
electromtrico

Agua
Potable y
Aguas
Residuales
-ULTIMA LNEA-

Ms informacin:
Oficina Guatemalteca de Acreditacin
Sistema Nacional de Calidad
Ministerio de Economa
PBX (502) 2247-2600
www.oga.org.gt

Pgina 3de 3
info-oga@mineco.gob.gt