CAME UNITED KINGDOM LTD

UNIT 3
ORCHARD PARK INDUSTRIAL ESTATE,
TOWN STREET, SANDIACRE,
NOTTINGHAM NG10 5BP

TECHNICAL
HELPLINE
0115 921 0430

TEL: 0115 921 0430


FAX: 0115 921 0431
INTERNET - www.cameuk.com
E-MAIL - enquiries@cameuk.com

0
0
0
6
G
D
R
GA
ions
t
c
u
r
t
s
n
I
n
Installatio d barriers
oa
for swift r

THE GARD KIT CONSISTS OF:


BARRIER UNIT
CONTROL PANEL
ALUMINIUM BARRIER ARM
RED PHOSPHORESCENT STICKERS
SAFETY BEAM POST
SAFETY BEAM

INTRODUCTION
THESE INSTRUCTIONS WILL SHOW YOU HOW TO INSTALL A
GARD AUTOMATION SYSTEM FOR SWIFT ROAD BARRIERS.
PLEASE READ THESE INSTRUCTIONS AND DIAGRAMS
CAREFULLY BEFORE STARTING ANY WORK.

UNDER NO CIRCUMSTANCES SHOULD THIS EQUIPMENT BE OPERATED UNLESS FITTED TO A GATE.

FAILURE TO COMPLY WILL INVALIDATE THE GUARANTEE.

GENERAL SPECIFICATION
DESCRIPTION:
This unit can be used to control entrances up to 6.5 metres wide (with accessories on the barrier up
to 6metres). Designed and constructed by CAME in compliance with current safety standards (UNI
8612) and with an IP54 protecting rating.
Guaranteed for 12 months unless tampered with by unauthorised personnel.

MODELS:
G6000. Barrier with non-reversible 24V DC gear motor, case in galvanised steel with enamel finish,
control panel and internal drive system.
OPTIONAL ACCESSORIES:
G0601 Rectangular cross-section, 100x40x6850mm aluminium barrier with white enamel finish.
G0602 Tubular cross-section, 100mm dia x 6850mm aluminium barrier with white enamel finish
(recommended for areas subject to strong winds)
G0603 Red anti-collision bumper strip with end caps, for G0601 barrier.
G0460 Pack of 6, 24V DC signal lamps with brackets for fitting to G0401 barrier with flash control
circuit board.
G0461 Red phosphorescent stickers for barrier.
G0462 Non-moving support for barrier.
G0463 Moving support for barriers.
G0465 White enamelled aluminium fencing for barriers.
G0467 Joint for G0601 barrier.
G0468 Support for attachment of safety beam to casings.
G0469 Support for attachment of flashing light assembly.
ATTENTION! For ease of installation and conformance to current safety norms, we recommend
installation of CAME safety and control accessories.

TECHNICAL CHARACTERISTICS

TYPE

WEIGHT POWER
KG
SUPPLY

CURRENT
DRAW

MOTOR
POWER

G6000
G6001

230V AC
24V DC

1.3A-230V
15A-24V

300W

72

DUTY REDUCTION
MAX TIME
CYCLE
RATIO
TORQUE
HEAVY
DUTY

1/202

600Nm

EXTERNAL DIMENSIONS

450
295

914

1077

460

240

4-8s

TECHNICAL DESCRIPTION
A

Case constructed in 2.5mm galvanised stainless sheet with an enamel finish (G6000), or in 2mm
stainless steel, with a satin finish (G6001), factory configured to accept all required accessories.
The access door for inspection can be locked onto the case with a personal key.

Mounting base in galvanised steel with anchor stays and bolts for anchoring the case to the
baseplate.

The flange is in galvanised steel. This holder allows the barrier to be quickly and securely locked.

Manual release system.

Motor: 24V DC reduction gear, non-reversible with die-cast aluminium housing and is
permanently lubricated with liquid grease.

A spring acts as counterbalance for precise uniform movement.

An internal shock absorber/travel stop is provided.

Limit switch assembly.

Control panel (ZL37F)

#
H

$G

Technic l description
4

INSTALLATION
Construct an adequate concrete base of the correct size for the installation of the unit. When pouring,
sink the anchoring stays and the mounting base for the unit into the concrete. The concrete base must
be perfectly level and clean from end to end. All screw threads must be completely accessible from
the surface of the concrete base. The electrical cables from the unit must also protrude from the base.
When the concrete is set place the unit on the base. It is good practice to have the inspection door
on the inside of the property. Tighten the unit down and check for level. Fit the barrier arm and adjust
the mechanical stops to stop the arm in the desired position.

140

240

380
460

Mounting base for case

Cable exit

COMMISSIONING
1. Ensure that the barrier is securely fastened to the base plate with the bolts provided. It is good
practice to install the barrier so that the access door is on the inside of the installation.
2. First determine the length of our barrier arm the insert the arm into the holder and secure with the
four allen screws provided. Adjust the mechanical stops B and C to obtain the desired vertical and
horizontal positions. (see figure 1)

B
A

3. The G6000 Barrier is supply with both springs installed in position B. If the final configuration of you
barrier requires a spring change follow the illustrations below.

Lm
Spring
Positions

<4
1A

<5
1A

<6
1B
1B

<6.5
1A

Lm
Spring
Position

<4
1A

<5
1B

<6
1A
1B

A
Spring
attachment
Points

With skirts or
Mobile support

Lm
Spring
Position

<4
1B

<5
1A
1B

<6
2B

4. Unlock the gearmotor and change the position of the springs (do not throw away the spring if not
used)
5. The barrier arm should be balanced at 45 for the barrier to work correctly.
1) Manually release the gear motor by using the manual release key.
2) Loosen locknuts B on the tension rods A.
3) Manually adjust the springs to increase/decrease their tension until the barrier arm is balanced at
45.
4) Now tighten the locknuts and re engage the gear motor by using the manual release key.

200 max

80 max

6)
7)

Connect mains power to terminals L1 and L2 and connect to a suitable earth.


Set all dipswitches off accept 8 and 9 ON for commissioning and insert a wire link between
terminals 2 and C1
8) Set potentiometer SENS to the halfway position for commissioning.
9) Set potentiometer TCA to minimum for commissioning
10) Set the Transformer as follows for commissioning: - SPEED to minimum and DECLERATION to
minimum.

Deceleration

C
O
M

Max

Speed

Min

Min

Med

Max

To set the speed and deceleration, move the faston connectors A and B onto the indicated
terminals

11) Ensure that the barrier arm is locked in the 45 position.


12) Momentarily pulse terminals 2 and 3 and the barrier should move to the open Position. Once the
barrier is in the up position pulse terminals 2 and 7 to make the barrier come down.
13) Prove and adjust the open and closed limit stops to the desired position.

14) Check the sensitivity of the barrier by physically trying to stop the barrier when it is moving to the
closed position, If the arm is easily stopped the power needs to increased by turning
potentiometer SENS more to the minus position.

TRIMMER SENS

15) If automatic closing is required move dipswitch 1 to the on position and adjust potentiometer TCA
until the desired time is achieved.
16) If safety beams or induction loops are used to prevent the barrier closing onto vehicles, remove
the wire link between terminals 2 and C1. This will give you re-opening during closing.
17) If Emergency stop is required insert the safety device (normally closed) into terminals 1 and 2
and move dipswitch 9 to the OFF position.
18) If a closed only button is required move the jump strap that is positioned between the terminal
blocks to the number 4 position. This will give you closed only on terminals 2 and 7.
19) If a full-length barrier arm is fitted with accessories it is advised to use the increased braking facility
by moving dipswitch 10 to the OFF position.

10

TROUBLE SHOOTING
Fault

Action

Barrier goes up but will not go down

If NO safety devices are fitted check that there is


a link fitted between terminals 2 and C1.
If safety devices are fitted check that they are
giving a closed circuit when the are working
normally.

The barrier stalls when moving up or down

Check that the barrier is balanced at the 45when


the barrier is manually released.
Check that the barrier sensitivity is set correctly
and adjust accordingly.
(minimum sensitivity gives you maximum power)

The barrier arm stalls when a


short arm is fitted

Check all of the above


Check that the increased braking facility has not
been used (dipswitch 10)

TECHNICAL HELP LINE


0115 9210430

11

TECHNICAL DESCRIPTION OF ZL37F


CONTROL PANEL
This control board is powered by 230V a.c. across terminals L1 and L2, and is protected by a 3.15A
fuse on the main power line. Control systems are (24) powered by low voltage and protected with by
a 2A fuse. The total power consumption of 24V accessories must not exceed 20 W.

SAFETY
Photocells can be connected to obtain:
a) Re-opening during the closing cycle;
b) Total stop: the movement of the bar is interrupted, and the automatic closure cycle is disactivated.
Use the keyboard or the radio transmitter to resume movement of the bar;
- Amperometric safety device: see
NOTE;
- Fixed operating time of 20 sec.

OTHER FUNCTIONS
- Automatic closing: The automatic closing timer is automatically activated at the end of the opening
cycle. The preset, adjustable automatic closing time is automatically interrupted by the activation of
any safety system, and is deactivated after a total stop command or in case of power failure;
- Immediate closure (the bar is lowered automatically after the vehicle has passed the safety devices,
on the terminals 2-C5 of the control panel;
- "Operator present" function. Bar operates only when the pushbutton is held down (the radio remote
control system is deactivated);
- Obstacle detection: When the motor is stopped (bar is closed, open or half-open after an
emergency stop command), the transmitter and the control pushbutton will be deactivated if an
obstacle is detected by one of the safety devices (for example, the photocells);
- Flashing light activated before opening and closing cycle begins;
- Activation of a 24V output signal during the movement phases and in the closed position;
- "Slave" operation when two motors are used in combination (see page 22);
- Increases the braking action on the barrier;
- Selection of command sequence: open-close, open only.

ACCESSORIES CONNECTED IN SERIES


- Flashing signal light (25W max.), when bar is in motion.

OPTIONAL ACCESSORIES
- Open barrier pilot lamp (3W max.). This is a light that indicates the barrier open position and turns
off when the barrier activates the closing end-stop (terminals 10-5);
- LB35 board, used to power the automation system using battery power in case of a power failure.
When the power supply is restored, the batteries are recharged automatically (refer to instruction
sheet);

ADJUSTMENTS
- Sensitivity of amperometric safety system: min./max.
- Automatic closing time

12

ZL37F MOTHERBOARD
M

M ax. M in. M in.M ed. M ax.

"A"

"B"

L1T L2T

PT

3 4

5 6

8 9 10

QU ADRO CO M AND O

ZL 37

MAIN COMPONENTS
1
2
3
4
5
6
7
8
9
10
11
12

Terminal block for external connections


3.15A line fuse
2A accessories fuse
"Function selection" dip-switch
Radiofrequency board socket (see table)
TCA trimmer: automatic closing time adjustment
SENS trimmer: amperometric sensitivity adjustment
Button for memorizing code numbers
Radio code / automatic closing signal LED
Connectors for power supply motor
Connectors for connection to battery charger (LB35)
Jumper for selection of type of control for button in 2-7

13

DIPSWITCH SELECTION OF FUNCTIONS


L1

L2

L1T L2T

PT

Vel.

Rall
.

2 3 4

5 6

8 9 10

QU ADRO CO M AND O

ZL 37

ON
OFF

ON 1

5 6

9 10

1 ON

Automatic closure enabled;

2 ON

"Only open" radio control or pushbutton function enabled (with plug-in radiofrequency
board);

2 OFF "Open-close-reverse" radio control or pushbutton function enabled (with plug-in radio
frequency board);
3 ON

24V output voltage on 10-E terminals when the barrier is in motion and in the barrier's
closed position, enabled;

3 OFF 24V output voltage on 10-E terminals when the barrier is in motion, enabled;
4 ON

"Operator present" function enabled;

5 ON

Pre-flashing (aperture and closure) enabled;

6 ON

Obstacle detection device (motor of limit position) enabled;

7 ON

"Slave" operation (motor is controlled externally) enabled;

8 OFF Immediate closure function enabled; activate safety device (2-C5);


9 OFF "Stop" button enabled; activate safety device (1-2);
10 ON Function that increases the braking action on the barrier enabled;
14

PROGRAMMING THE REMOTE CONTROLS


T432S (MINI-PINK) Remotes
Remove the battery cover off of the remote and change the Factory set code to a unique code for the
installation via the 10 dipswitches.
Insert the frequency card into the control panel (item 5 on motherboard). Identify the little yellow button
on the motherboard and press and hold the little yellow button in and an LED will flash. Then press
the button on the remote control you wish to operate the equipment with and then let go of both
buttons. Make sure any additional remotes are the same code. You do not have to program these into
the board - they should work.
actionning LED
"AF" BOARD

ON

- T.C.A. -

OFF

1st key fixed


on channel 1

NS. -

MOTHERBOARD

Code selection
dipswitch:
set the same
code
programmed
on receiver

ON 1

5 6

9 10

Channels Scheme

1
Channels
selection
jumpers

Channel 1

Channel 2

4 pins strip
2nd key preset on
channel 2; put the
jumpers as shown in
figures to change

3
Channel 3
15

Channel 4

PROGRAMMING THE REMOTE CONTROLS


Use on existing system
(with TOP at 433.92 MHz)
1.

Press the key to encode until, after 7 seconds of


flashing, the red signalling LED remians on. (fig A)

2.

Within 10 seconds, bring the existing transmitter


closer from the rear part and press the pushbutton you
want to copy for a few seconds. (fig B)
Once it has been saved, the LED will flash 3 times
and the transmitter will be ready for use.

Repeat 1 and 2 for the other pushbuttons. (NB: the code of


another system can be saved).

Use on new system


Consult the documentation of the electric board to save the first transmitter, then follow the procedure
described above to duplicate it in the quantity desired.

Red signalling LED

To open battery compartment, press and slide.

16

ZL37F
ELECTRICAL CONNECTIONS
E +10-11 1 2 3 5 7 C1C5 INTERBLOCCO FA FC F PT M N

L1
L2

230V (a.c.) power supply

M
N

24V (d.c.) motor

10
E

Uscita 24V in movimento (es.lampeggiatore - dip 3 OFF)


DIP 3
24V output in motion (e.g. flashing light - Pos. B Jumper)
during movement (e.g. flashing light)
OFF
Sortie 24V en mouvement (ex. branchement clignotant - Jumper Pos. B)
Ausgang 24V in Bewegung (z.B. Blinker-Anschlufl - Jumper Pos. B)
24V output
Salida de 24V en movimento (ej. l mpara intermitente - Jumper Pos. B)

during movement and in the closed position

10
5

24V -3W max. "bar-opened" signal lamp

10
11

Power supply accessories (max. 40W):


24V (a.c.) with power supply at 230V (a.c.)
24V (d.c.) with power supply at 24V (d.c.)

DIP 3
ON

N.B. When connecting the


photocells (TX and RX),
observe the correct
polarities.

TX

RX

NO C NC

1
2

10 11

Pushbutton stop (N.C.)

17

ZL37F
ELECTRICAL CONNECTIONS
2
3

Open pushbutton (N.O.)

2
7

Collegamento radio e/o pulsante (N.O.)


per tipo comando, vedi dip-switch 2
Connector (N.O.) radio and/or pushbutton. See DIP 2 for command type
Connector (N.O.) radio and/or pushbutton
see dip-switch 2 for command type
Connection radio et/ou bouton-poussoir (N.O.)
pour commande voir dip-switch 2
Anschlufl Funkkontakt und/oder Taste (N.O.)
Steuerart
siehe dip-switch
2
Button operation:
closure only
Conexin radio y/o pulsador (N.O.)
para mando mirar dip-switch 2

JUMPER

JUMPER

2-C1
2
C1

Contact (N.C.) for re-aperture during closure

if not used
E 10 11 1 2 3 5 7 C1 C5

dip 8 ON
2
C5

Contact (N.C.) of immediate closure

F
FA

Connection microswitch deceleration opens

F
FC

Connection microswitch deceleration closes

Antenna connection

18

if not used

ZL37
BARRIER SPEED ADJUSTMENT

C
O
M

DECEL
SPEED

ARM
SPEED

Max Min Min Med Max

To set the barrier speed and deceleration, move the faston connectors A+B onto the indicated
terminals

19

CONNECTION FOR TWO COMBINED MOTORS


CONTROLLED TOGETHER
SX

DX

CAME

1) On one of the two control


panels, set Dip 7 to ON in order
to select the motor controlled
externally (slave).

1)

Slave motor 2control panel

Dc
e e
rl a
tio n
a le n
R
ta m
e n
to
a n
R
le tis se
me
n t
G sc
e h
w .
b
A a
n m
h e
De
c le
r c
a n
i
C
O
M

S
p
e e
V
o
c
l it
d
i te
V
s se
G sc
e h
w .
e lo
V
c a
id d

M xa . M in .M in . M e
d .M xa .

B
" "

"A "

V e
l.
R a
l .

lin e fu e
s
m o to
r fu s e
a c s
e s
o ri s
e fu s
e

Z L
3 7

D ce ler a
tio n
a n
R
le tis sem en t

Sp e d
i tes se
V
e clo a
V
id d

D ec ler a
ci n

B
" "

A
" "

V el.
R a
l .

2)

2)
Wire
the
electrical
connections only on the
terminal board for the pilot
motor in the normal.

C
O
M

Decelera ti on
Rallent amento
Ralent iss emen t
Geschw.
Ab nahme
Decelera ci n

Speed
Ve locit
Vi tes se
Geschw.
Velocid ad

M ax. M in. M in. M ed. M ax.

"B"

"A"

(pilot) motor 1terminal block


L1

L2

L1T

L2T

PT

Ve l.

Ra ll.
line f use
m o to r fu se

a cce sso rie s f use

10

C O N TR O LP ANE L

ZL 3 7

E +10-11 1 2

Decelerati on

Speed

Ralent iss emen t

Vi tes se

3 5 7 C1C5

INTERBLOCCO

FA FC F PT

M N

Velocidad
Deceleraci n

3) Connect the two control


panels using the interlock
terminals as shown in the
figure.

3)

"B"

L1
Decelera ti on
Ral lent amento
Ral ent iss emen t
Geschw.
Ab nahme
Decelera ci n

L2

L1T

L2T

Spee
eed
Ve locit
Vi tes se
Geschw.
Vel ocid ad

PT

"A"

Ve l.

Ra ll.

C
O
M Max. Min. Min. Med. Max.

"B"

C
O
M

"A"

ee

L1

L2

L1T

L2T

PT

INTERBLOCCO

FA FC F PT

ee

L2

L1T

ad

L2T

PT

Ra ll.

Ve l.

3 5 7 C1C5

INTERBLOCCO

ad

Ra ll.

line f use

line f use

motor fuse

motor fuse

accessories f use

accessories f use

10

1 2

CO N TR O LP ANE L

ZL 37

"A"

E +10-11 1 2

M N
L1

Ve l.

Spee
eed
Ve locit
Vi tes se
Geschw.
Vel ocid ad

"B"

3 5 7 C1C5

Decelera ti on
Ral lent amento
Ral ent iss emen t
Geschw.
Ab nahme
Decelera ci n

Max. Min. Min. Med. Max.

10

CO N TR O LP ANE L

ZL 37

(pilot) motor 1terminal block


ee

Slave motor 2terminal block


ee

ad

ad

20

HANDING THE G6000 BARRIER


OUTSIDE

SX

DX

INSIDE

SX = With the barrier arm on the outside and the cabinet facing the inside of the property. This unit is
usually positioned on the left.
DX = With barrier arm on the outside and the cabinet facing the inside of the property. This unit is
usually positioned on the right.

IF THERE ARE ANY PROBLEMS PLEASE CONTACT THE CAME


TECHNICAL HELPLINE:

0115 921 0430


21

NOTES

22

CONTACT INFORMATION

CAME UNITED KINGDOM LTD


UNIT 3
ORCHARD PARK INDUSTRIAL ESTATE
TOWN STREET, SANDIACRE, NOTTINGHAM NG10 5BP
TEL: 0115 921 0430
FAX: 0115 921 0431
INTERNET : www.cameuk.com
E-MAIL: enquiries@cameuk.com
THIS INSTALLATION WAS COMPLETED BY:
.........................................................................
NAME..............................................................
ADDRESS........................................................
.........................................................................
.........................................................................
.........................................................................
TEL........................ MOBILE............................
DATE OF INSTALLATION................................