Contents
Chapter I Alarm Panel Function .................................................................................... 2
Chapter II Alarm Panel Instruction and Installation ...................................................... 4
Chapter III System Setting: ......................................................................................... 10
3.1 Function Key-press Introduction ............................................. 10
3.2 Remote Controller Setting ....................................................... 10
3.3 Wireless Defense Zone Setting ................................................ 12
3.4 Alarm SMS Center Number Setting ........................................ 13
3.5. Alarm Telephone Number Setting .......................................... 14
3.6 Time Setting ............................................................................ 15
3.6.1 Alarm History Checking ............................................... 15
3.6.2 System Timing Arm Setting ......................................... 15
3.6.3 System Timing Disarm Setting ..................................... 16
3.6.4 System Timing Home Alarm Setting ............................ 16
3.7 Voice Recording ...................................................................... 16
3.8.Network Center Number Setting ............................................. 17
3.8.1 Network Center Telephone Number Setting ................. 17
3.8.2 User ID Setting ............................................................. 17
3.8.3 Alarm Upload Setting ................................................... 18
3.9 Wireless Control Function Setting........................................... 18
3.10 System Function Setting ........................................................ 19
Chapter IV System Remote Control ............................................................................ 21
Chapter V Smart APP Control ..................................................................................... 22
Chapter VI Telephone Call Remote Control................................................................ 24
Chapter VII SMS Remote Control .............................................................................. 25
Chapter VIII Components List .................................................................................... 27
Fixed Code Setting(additional).................................................................................... 28
1 / 33
System Introduction
This GSM alarm system is TFT color display screen, it adopts GSM Quad-band frequency mobile
communication network and related digital processing technologies; through the SMS data
transmission mode and voice platform of GSM Quad-band frequency mobile communication
network, which really realizes the application that is not limited by time and space. Well-designed
circuit structure, user-friendly operating interface and remote control embody the human-oriented
design concept, it is convenient and easy to use and operate. Functions details below:
SMS alert & auto-dial alert when AC Power outage, AC power recovered.
with standby rechargeable battery. The host automatically stores system status, while its power is
off.
With wired MIC interface, switching the silence and siren.
Talkback Function: can speak with field person.
Alarm panel TFT screen with language switch ,internal clock, signal shows, easy to operate.
Arm/disarm and program the system by control keyboard on the mainframe & phone & SMS &
remote controller.
Support 6 arm/disarm methods: SMS , phone, panel screen, APP, remote controller , center
software.
Timing arm/disarm function.
Record function: Maximum recording time:10s.
Voice functionsupport play the user record voice.
Built-in high standard internal antenna with strong signal
With ROHS/CE/FCC certifications, compliance with 3C Safety Standard and GB12663-200
1 Government Standard.
3 / 33
Wired guarding zones connection (normally closed /open) optional, GND indicate earth wire.
4 / 33
Technical Parameters
5 / 33
Wireless magnetometer
7 / 33
Note:
1. Magnet should be vertically aligned with launch box, the two parts gap is less than 10 mm;
2.For the best wireless transmission range, please pull out the antenna and vertical direction;
3.Weak indicator light indicates the battery power is low, please replace the battery, or omissions
may occur.
Unfold the back shell and install the battery. The PIR should be 1.5-2.5m far from the ground, and
the probe should be fixed toward the monitor area.
8 / 33
Infrared detectors have a higher sensitivity to lateral movement, and lower sensitivity to vertical
movement, so it is best to install the detector's direction are vertical with peoples walking
direction.
Avoid facing the window, air conditioner, stove, sun and other place, where temperature
changes quickly and air flow rate is higher or the place where the pets often pass, so that avoid
false alarm;
The lens indicator light indicates that the battery power is insufficient, please replace the battery,
9 / 33
Input 6 numbers password on the panel (Factory default password:123456),then push SET key to
enter the system setting ,it shows use remote controller set menu, operating detail as below :
The system supports 8 remote controllers at most . User should login the system before
adding remote controller, input 6 password(123456) and enter menu ,press 4 (move left) 6(move
right) can match the remote controller, then press the set enter match code mode. the details as
following:
menu
Note: if the address code repeats, it means it is the same as the remote control encoding, unable to
add successfully.
How to delete remote controller
Press4(move left),6(move right)choose the remote controller which need deletedPress (move
up)(move down) to deleteThen press SET to confirmThe host show delete completed.
11 / 33
12 / 33
SET
sensor signal
Note: when it was triggered alarm, also the SIM card work well, but user cant receive a warning
13 / 33
message, please add the International Code in front of the telephone NO., and press the 00 number
for +
For example: International Code is +86telephone NO. is 18826584803directly input
008618826584803 is OK .
The method to set telephone NO. can refer to the SMS telephone NO..
Note:
when it was triggered alarm, also the SIM card work well, but user cant receive a warning message,
please add the International Code in front of the telephone NO., and press the 00 number for +
For example: International Code is +86telephone NO IS 18826584803directly input
008618826584803 is ok .
15 / 33
16 / 33
This system support 1 group wireless siren,7 groups wireless switch control household appliances
and 8 groups door access control card. Setting method: enter wireless control menu ,confirm whether
the wireless control is valid. Otherwise all the operations in this menu are invalid.
menu
18 / 33
19 / 33
075525911778**#0# press SET key, restore factory settings, and the password is 123456.
Beep and LCD showed Arm, after 30S(The timing can be changed, please refer to 4.9.2),the
system into Arm mode, The indicator light
flashing.
system will get into the emergency alarm mode and external alarm siren working, at the same time,
send SMS message and call network center three times .
21 / 33
Chapter V
Users can scan the two-dimensional code in the box, select the corresponding mobile phone
operating system and install the APP application program, the user can set alarm SMS and alarm
telephone to control host arm/ disarm, open or close remote switch by APP.
1.After installing APP successfully select settings (Pic 1), first add the user (Pic 2) phone NO. User
should set that NO. inside the host, and then click save. Delete and revise user in the same way.
Pic 1
Pic 2
2.Configure phone alarm number and SMS alarm number, click on the corresponding button as (PIC
3) shown. And then select the corresponding user after editing the alarm number. Click on the "save"
and then click "send", received informing SMS means saved successfully. Telephone alarm number
and SMS alarm number can be same number or different numbers. When alarm occurs ,the host will
send alarm SMS and dial the alarm call. Click on the list (pic 4)
22 / 33
Pic 3
Pic 4
3. Click the users on the list, select corresponding user to arm ,disarm, home arm etc related
operations (shown Pic 5). Click Remote will appear Pic 5 . (this function needs to connect to the
related equipment, if you need pls get in touch with us)
23 / 33
Pic 5
Pic 6
24 / 33
operational order
function description
1##
1##
2##
5##
Check version
6##
7##
Open gate
9##
10##
st
nd
13#3rdSMS User#
14#4thSMS User#
15#5thSMS User#
16#1stcallingUser#
17#2ndcallingUser#
20#5thcalling User #
21# ##
30#new password#
To change password
E.g. 123456#30#888888# means the systems password has
been changed to 888888
33#0#
34#0#
35##
37##
after 30 seconds.
38##
39##
Timing arm
1=0:disarm =1Out arm
2 =the time of timing arm. It takes 4 digitals only
E.g. 123456#31#1#08:30#
automatically at 08:30
26 / 33
42##
43##
91##
91##
123456#91#13807550755#set
center
phone
number
91#0#
Settings for Zone type and SMS content.(Only for SMS operation)
Used to set the wireless zone 01
1is used to set ZONE TYPE = 1 for arm zone =
2for home arm zone
101##SMS
alarm
content#
188##SMS
alarm
Used to set the 88th zone type and its alarm message
content#
27 / 33
each guarding zones, before setting fixed code, need to disassemble the sensor, then operate. Its
jump code mode is shown as following
pic.
28 / 33
29 / 33
30 / 33
After-sale Warranty
31 / 33
Guarantee Card
Customer
Product Model
Product ID NO.
Production Date
Purchase Date
Maintenance records
Welcome to choose our GSM alarm system, any questions, please kindly tell us !
If satisfied, maybe you can recommend to your friend, thank you !
Hope build long time business relationship with you, thank you !
V1.00
32 / 33