The hardware models V1280/E2900 etc uses the Lights-out management to manage the hardware. LOM is
a set of software tools on the Sun Fire V1280/E2900 servers. LOM is used to perform user maintenance and
administrative activities.

2 de 14

Show the current network configuration

lom>shownetworkv

To assign an IP address to ILOM


lom>setupnetwork
NetworkConfiguration

Isthesystemcontrolleronanetwork?[no]:yes
UseDHCPorstaticnetworksettings?[DHCP]:static
Hostname[]:somename
IPAddress[]:129.xxx.xxx.xxx
Netmask[255.255.255.0]:255.255.255.0
Gateway[]:129.xxx.xxx.xxx

3 de 14

DNSDomain[]:somewhere.nowhere.com
PrimaryDNSServer[]:129.xxx.xxx.xxx
SecondaryDNSServer[]:129.xxx.xxx.xxx
RebootingtheSCisrequiredforchangesinnetworksettingstotakeeffect.

To login to the OS console from ILOM


lom>console

To logout from the ILOM


lom>logout

To check the current escape character


lom>showescape
#.

To set a new escape character


lom>setescape~.

To set/reset password of the current user


lom>password
Enternewpassword:admin

4 de 14

Enternewpasswordagain:admin

To see all the hardware


lom>showboards

To only see the CPUs


lom>showboardspcpu

To only see the memory modules


lom>showboardspmemory

To only see the power supply units


lom>showboardsppower

To see the version of each individual component


lom>showboardspversion

To see individual component status of a system board

5 de 14

lom>showcomponentsb0

To check the various sensors


lom>showenvironment

To see the logs


lom>showlogs

To poweron the system and boot solaris OS


lom>poweron

To poweron only a specific component


lom>poweronsb2

To shutdown Solaris OS and poweroff the system to standby mode


lom>shutdown

To poweroff the entire system

6 de 14

lom>poweroff

To poweroff a specific hardware component


lom>poweroffsb2

The hardware models Sun Fire 3800, 4800/E4900, 4810, and 6800/E6900 uses the system controller to
manage the hardware components of individual domains that may have been created. So we have 2 login to
a specific domain system controller from platform shell in order to manage the hardware of that domain. The
showplatform command shows all the configured domains on the system.

To check all the domain and platform related information


schostname:SC>showplatformv

7 de 14

To view system controller details


schostname:SC>showscv

To view SC logs
schostname:SC>showlogsv

To view current SC connections


schostname:SC>connections

To reboot a system controller


schostname:SC>reboot

To see all the hardware details of a domain


schostname:SC>showboards

To see only the CPUs in a specific domain


schostname:SC>showboardspcpu

To see only the memory in a specific domain

8 de 14

schostname:SC>showboardspmemory

To see only the power supply unit in a specific domain


schostname:SC>showboardsppower

To see the version of each individual component


schostname:SC>showboardspversion

To see individual component status of a system board


schostname:SC>showcomponentsb0

To start a domain (Domain A)


schostname:A>setkeyswitchon

To stop a domain (Domain A)


schostname:A>setkeyswitchoff

To see the logs of a specific domain (Domain A)

9 de 14

schostname:A>showlogs

To test a CPU/memory board SB0 in domain A


schostname:A>testboardsb0

To reset a domain
schostname:A>reset

To send break to the OS from Domain SC


schostname:A>sendbreak

To flash update the system


schostname:SC>flashupdateyfftp://root:password@192.168.1.10/firmwarescapprtos

Most Commonly used ALOM commands (Cheat Sheet)


Most Commonly used LOM commands (Cheat Sheet)
Most Commonly used ILOM commands (Cheat Sheet)
Most commonly used XSCF commands (Cheat Sheet)
Most Commonly used RSC commands (Cheat sheet)

10 de 14

Filed Under: Hardware

M4000 / M5000 : How to assign IP address to XSCFU


Complete Hardware Reference : SPARC T3-1 / T3-2 / T3-4
Most commonly used XSCF commands (Cheat Sheet)
How to login into console from ILOM, ALOM, LOM, ELOM, XSCF, RSC
How to collect XSCF snapshot on M-series servers (M3000 / M4000 / M5000 / M8000 / M9000)

11 de 14

Your email address will not be published. Required fields are marked *
Comment

Name *

Email *

Website

12 de 14

1. LDoms Cheat Sheet


2. SVM Cheat Sheet
3. ZFS cheat sheet

13 de 14

How to move a datafile from file system to ASM


RHEL 7 RHCSA Notes : Create hard and soft

Thegeekdiary
546 Me gusta

links.
CentOS / RHEL 7 : How to boot into Rescue
Mode or Emergency Mode

S el primero de tus amigos en indicar que te gusta esto.

How To Check World Wide Port Names (WWPN)


of Tape Drives Attached to Linux host

India based Unix Admin, Cloud Evangelist and a

14 de 14

Virtualization lover. Read more about me here ...


@patilsandeep911

S-ar putea să vă placă și