For internal corrosion direct assessment (ICDA), the gas IM rule also
specifies a four-step process, based on the principle that liquids collect
on the bottom of a pipe when a critical angle of inclination is
exceeded for a specific gas flow velocity. (192.927):
Step One: Pre-assessment - to gather and integrate data and
information to determine whether ICDA is feasible for the segment, to
support use of a model to identify locations where liquids may
accumulate, and to identify where liquids may enter the pipeline.
Step Two: CDA region identification - to apply a specific model to
identify elevation conditions and other pipeline fittings where liquids
may accumulate.
1. For external corrosion (EC), the plan must comply with 192.925,
however:
Only one indirect examination tool may be used, and one high
risk indication examined in each ECDA region; and
All immediate indications must be excavated in each ECDA region.
For ICDA and for SCCDA: ASME B31.8S 6.4, Appendices A2, B2 &
A3.
For ICDA: Gas Technology Institute, GRI-02-0057, Internal
Corrosion Direct Assessment of Gas Transmission Lines Methodology.