ENGLISH
Logic C22
Logic C22S
230 V~ / 50 Hz
12 V 6.5 Ah
24 V= / 2x12A (max)
24 V= / 0.3 A (nominal)
24 V= / 0.5 A (peak)
-15 C / +50 C
IP54
225x320x120
230 V~ / 50 Hz
/
24 V= / 2x4.5A (max)
24 V= / 0.3 A (nominal)
24 V= / 0.5 A (peak)
-15 C / +50 C
IP54
225x320x120
TECHNICAL DATA
Power supply
Batteries
Motors output
Accessories power supply
Temperature
Degree IP
Dimensions
1.
ELECTRICAL CONNECTION
1.1 Controls
Description
3 N.O. OPEN
4 N.O. CLOSE
It starts the closing or opening operation in sequence: openstop-close-open. Warning: if the automatic closure is
enabled, the stop is not permanent but lasts for the time set
by means of TC.
6 N.C. OPENINGSAFETYCONTACT
7 N.C. CLOSINGSAFETYCONTACT
EMERGENGY STOP
30
OPEN
This is the seat for the coupling of the radio receiver. The remote
control function (open or step-by-step) is select by means of DIP1.
(OFF = 1-5; ON = 1-3).
WARNING: Link up all N.C. contacts (if not used) by means of jumpers. The terminal bearing the same
number are equivalent. The given operating and performance features can only be guaranteed with
the use of DITEC accessories and safety devices.
ENGLISH
Function
Control
ENGLISH
Output
Description
1
0
+
-
24V = / 0.3 A (nominal) Accessories power supply. Output for power external accessories
0.5 A (peak) including the gate-open signal lamp. Protected exit electronically.
14
24V = / 50 W
Flashing light (LAMPH). Is activated upon opening or closing. For preopening or pre-closing flashing see DIP2.
Protected exit with fuse F2.
15
24V = / 1.2 A
Electric lock. With the 12 V electric lock, link up the 8.2 5 W resistance in series. Protected exit with fuse F2.
13
24V = / 3 W
Gate open lamp. Turn on a light that goes off when the gate is closed.
BAT (Only for Logic C22) The electric panel is fitted with two series-connected 12V= 6.5Ah lead-acid storage
batteries. The battery is charged and kept charged only when the electric panel is powered from the mains; the
battery is used as a buffer or in case of power failure and is cut out automatically after voltage dropping to below
22V for 120 seconds.
Connect mains and battery to the electric board at least half an hour before powering the installation (in order
to charge the battery). To power off the electric board, cut off mains and disconnect the batteries.
Attention: Always ensure that the battery is connected to the electric panel. The batteries are essential for
operations in the presence of : Box 3SH, Cubic 30H, Elit 50H/BH, Luxo 5BH.
1.3 Setting and adjustments
TC
MIN=0s
MAX=120s
VM
MIN
MAX
M1 (M2)
MIN=0s
MAX=45s
MIN=3s
MAX=30s
MIN=0s
MAX=45s
TR
RP
R1
ARC BH
OBBI 3BH
MIN = 0,75A
Automatic closure time. From 0 to 120 s. Count down initiates or starts up again:
- according to the time set by TC at the end of opening or upon an open command being
given, when the gate is stationary in the open position;
- for half of the time set by TC after triggering a safety device (1-6 / 1-7 /1-8) or at the end
of partial opening.
With 1-2 or 1-9 open, automatic closing is disabled. Closing 1-2 re-enables automatic
closing. If disabled from 1-9, automatic closing is once again enabled, by contacts 1-9
being reclosed, only after an open command is given.
Movement speed adjustment. Turning of the trimmer clockwise adjusts
opening speed from a minimum to a maximum. Closing speed is about two thirds
that of opening. If Obbi3BH/Arc BH-type motors are used, the opening speed
corresponds to the closing speed.
Motor 1 (2) operating time. The opening/closing manoeuvre is schematically shown in fig.
3.3 and 3.4. The overall speed of the manoeuvre actually consists of two speeds: one set via
VM of the duration of M1 (M2) and another, a slowing down speed, lasting for a fixed interval
of 5 s during opening and 10 s during closing. Set M2 to a minimum to operate only 1 motor
or 2 motors in parallel, simultaneously controlled by M1 and wired up as shown in Fig. 5.1
(for example in the case of two motors being mounted on the same overhead door).
Delay time adjustment. Controls the delay time of motor 1 during closing from 3 to 30 seconds.
During opening, the delay of motor 2 is fixed at 3 s (only in case of M2 not being set to a
minimum). With TR set to minimum, the delay time during closing is not always 3s but only after
an opening operation completed successfully by both wings. As far as all the installations in
which wing 1 overlaps wing 2 are concerned, trimmer TR must be set to min. 1/4.
Partial opening. From 0 to 45 s. (Can in no case be set to values greater than M1).
Obstacle detection adjustment. A safety device is located on the electric panel the
purpose of which is to stop door opening and closing in case of an obstacle being detected.
With R1=MIN, maximum sensitivity to obstacles is achieved (minimum thrust).
With R1=MAX, minimum sensitivity to obstacles is achieved (maximum thrust).
MAX = 3A
R1
BOX 3SH
CUBIC 30H
ELIT 50H/BH
LUXO 5BH
MIN = 1,53A
MAX = 12A
10
OFF /
Description
DIP1 Radio control selector
ON /
1-3 Open
DIP2 Pre-operation warning light (fixed at Disabled during opening, and enabled Enabled both during opening
3 s)
only during automatic closing with and closing.
TC set to more than 3 seconds. (*)
DIP3 Electric lock release
Disabled (*)
NIO
Abled
ON
Power on.
Signals that a safety contact (1-6 / 17 / 1-8 / 1-9) is open.
OFF
/
/
2. STARTING
WARNING The operations regarding point 2.3 and 2.4 are without safety devices.
The trimmer can only be adjusted with gate not moving
2.1
2.2
2.3
2.4
11
ENGLISH
F2
F1
ENGLISH
+
- +
36 35 34 33 32 31
L N
M2
Fig. 3.1
M1
F1
L N
A =
M2
max. max.
+
- +
36 35 34 33 32 31
230 V~
M1
230 V~
A C
A C
M2
M1
Fig. 3.2
5s
A M2
M1
5s
A
Fig. 3.3
BOX 3SH - CUBIC 30H - ELIT 50H/BH - LUXO 5BH
M2+25%
C
M1+25%
C
10 s
ARC BH - OBBI 3BH
M1
M2
C
C
10 s
Fig. 3.4
12
4. EXAMPLE OFAPPLICATION FOR ONE MOTOR SWING GATESAND FOR SPRING BALANCED UPAND OVER DOOR
M2
36 35 34 33 32 31
M1
Fig. 4.1
M1
M2
36 35 34 33 32 31 min. max.
ENGLISH
min.
M1
A =
= 1N4007
Fig. 4.2
5s
A M1
Fig. 4.3
BOX 3SH
CUBIC 30H
ELIT 50H/BH
LUXO 5BH
ARC BH
OBBI 3BH
M1
M1+25%
C
C
10 s
10 s
Fig. 4.4
5. EXAMPLE OF APPLICATION FOR UP-AND-OVER DOORS WITH 2 IN-PARALLEL MOTORS
M2
36 35 34 33 32 31
Two motors can be connected in parallel (Ex. 2 BOX
motors) as shown in figure 5.1.
Slow-down micro switches can be used after the
necessary connections as shown in figure 4.2 (M1 motor
only) have been made.
13