DATA SHEET

Project:

DS EP ELE 191

Rev. Date
Written
Verified
Approved
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

REPERE RESISTANCE :
RESISTOR TAG

Lieu dinstallation :
Site

Neutral earthing resistor

Rev. 02 - 10/05

Exploration & Production

Nombre de rsistance :
Number of resistor :
CONDITIONS GENERALES DINSTALLATION
GENERAL SPECIFICATIONS

Temprature ambiante :
Temperature of ambiant air

Maximum

Maximum

Altitude (si valeur excdant 1000 m) :


Altitude (if value exceeding 1000 m)
Atmosphre corrosive : Oui/Non
Corrosive atmosphere

Minimum

Minimum

Mtres
Metres

Hygromtrie

Humidity

Embruns salins
Sea spray

Autre

Other

H2S

18

LOCALISATION

Zone 2

Hors zone

Extrieur

Intrieur

On-shore

Off-shore

19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55

LOCALISATION

Area 2

Safe area

Out side

In side

On-shore

Off-shore

NORMES INTERNATIONALES APPLICABLES


INTERNATIONAL STANDARDS
IEC 79, IEC 85, IEC 364

Tension nominale :
Rated voltage

Intensit en rgime permanent


Permanent rating current
Capotage :
Housing

Galvanis
Galvanized

CARACTERISTIQUES TECHNIQUES
TECHNICAL SPECIFICATIONS
Tension disolement

Insulation voltage

kV

Limitation du courant :
Current limitation

Inox 316L
Stainless steel 316L

Dure limitation
Time limitation

Degr IP :
Enclosure protection degree

kV

Valeur
S ohmique
Ohms value

Visserie inox 316 :


Stainless steel 316 screw

Systme de peinture :
Standard fournisseur
Spcification particulire
Paint system
Supplier standard
Jobs specification
Manufacturer standard to be submitted at bid stage for approval
RACCORDEMENT
CONNECTION
Borne embrochable : Partie mobile
Equerre
Droite
Fourniture verouillage

Plug-in terminal
Moving part
Elbow
Straight
Interlock supplying
Traverse porcelaine :
Porcelain terminal
Cble :
Cable

Caisson :
IP
Housing

Cu

Borne(s) de mise la terre :


Earth terminal

Dimension :
Size

Hauteur
Height

Section
Section

mm2

Diamtre sur isolant


Diameter on insulation

PE nature

Gland type

mm

Diamtre sur gaine dtanchit


Outer diameter

De la rsistance
Des masses mtalliques
Section cble de terre
Of the metallic frame
Of the resistor
Earth cable cross section
CARACTERISTIQUES ET DOCUMENTS A FOURNIR PAR LE CONSTRUCTEUR
CHARACTERISTICS AND DOCUMENTS TO BE SUPPLIED BY MANUFACTURER
Profonde
Largeur
Poids
mm
mm
mm
ur
Wide
Depth
Weight

mm

mm2

kg