Documente Academic
Documente Profesional
Documente Cultură
A General Information
A.1 Name of Client
Type of Occupancy
A.2
Residential
Apartment
Hospital
Industrial
Educational
Cinema
Auditorium above 500
Auditorium below 500
Public Assembly
Commercial
Cold Storage and Ware House
A.3 Designed by
Structure
Architecture
Soil Test
A.4 Building Category
A
B
C
D
Hard
Medium
Soft
Weak
3 Structural Detail
3.1 Building Structural Type
3.1.1.1
Size of Column
3.1.1.2
First Floor
Second Floor
..
..
..
...
..
3.1.1.3
Number of Columns
3.1.1.4
Size of Beam
3.1.1.5
3.1.1.6
Foundation System
Isolated
Combined
Other(specify)
3.1.1.7
Grade of Concrete
3.1.1.8
3.1.1.9
3.1.2
3.1.2.1
Concrete Grade
3.1.2.2
3.1.2.3
3.1.2.4
Floor
Wall Height
.
.
.
Ground Floor
First Floor
Second Floor
3.1.2.5
Opening details:
Least distance from inside corner
Does the total length of opening in any Yes
wall exceed 50% of its length
Does the horizontal distance between
any two opening less than 600 mm or
1/2 of height of shorter opening
3.1.2.6
3.1.2.7
Wall Thickness
..
..
..
No
Yes
No
No
Yes
Plinth Level
No
Lintel Level
Roof Level
Gable Band
Ground Floor
First Floor
Second Floor
3.1.2.8
Types
Hard (Soil Type I)
Medium (Soil Type II)
Soft (Soil Type III)
Isolated
Combined
Other(specify)
NBC 105
IS 1893:2002
Other(specify)
Bearing Capa
Damping
Mass Participation in the 1st mode (x,y)
No. of modes considered for >90% mass participation
Scale Factor along x-direction
Scale Factor along y-direction
Total Deflection of Building along X-direction in mm
Total Deflection of Building along y-direction in mm
Interstorey Drift in mm
As per IS 1893:2002
As per NBC 105
Other(specify)
IS 456:2000
Other(specify)
IS 13920:1993
Other(specify)
Note:
I /we hereby certify that the proposed design of building and its various components comply all the requirements of
prevailing National Building Code of Nepal.
Signature:
Name:
NEC No.:
Designation
Name of consulting firm:
Address:
Date:
Bearing Capacity
Registration Nos.:
Contact No:
Date:
Note: 1) All the provisions need to be assessed using architerctural as well as structural drawings with some quick calcualtions wherever applicable.
S.N
2) The specific condition for assessed building in corresponding provision need to be highlighted.
Mandatory Attributes
Specific Conditions
Soft Storey: The stiffness of vertical lateral load resisting system Compliance
in any storey shall not be less than 60% of the stiffness in an
adjacent storey or less than 70% of the average stiffness of the
Non-Compliance
three stories above.
S.N
Attributes
Recommendation
Compliance
Non-Compliance
Specific Conditions
0
0.5
1
0
0.5
1
4
1
0
6
S.N
4
Attributes
Redundancy: The number of bays of moment frames in each
direction shall be greater than or equal to 2.
Specific Conditions
Nos. of bays in one direction is 2 and other
direction is <2
Nos. of bays in both direction < 2
S.N
Attributes
Specific Conditions
All columns are in grid line
upto 15 % of column out of grid line
16% to 50% of column out of grid line is
between
more than 50% of column out of grid line
All beams are continuous
upto 15% of beams are discontinuous
16% to 50% of beams are discontinuous
More than 50%of beams are discontinuous
Compliance
Non-Compliance
Projection 1m and no walls in projection
Projection 1m and full brick wall in projection
Projection>1 and no walls in projection
Projection >1 and full brick wall in projection
None columns has short column effect
15% columns has short column effect
16%-50% internal column has short column
effect OR upto 15% peripheral columns has
short column effect
More than 50% column has short column effect
Eccentricity 10%
Torsion: The estimated distance between the storey center of
mass and the storey centre of stiffness shall be less than 30% of 10% <Eccentricity 20%
10
the building dimension at right angles to the direction of loading
considered.
20% <Eccentricity 30%
Adjacent Building: The clear horizontal distance between the
building under consideration and any adjacent building shall be
11 greater than 4 % of the height of the shorter building, expect for
buildings that are of the same height with floors located at the
same levels.
1
0
6
1
0
0.25
0.75
0.5
1
50
0
4
Specific Conditions
S.N
Attributes
Specific Conditions
Mc1.1Mb
Mc<1.1Mb
0
5
1
Compliance
Non-Compliance
Compliance
Non-Compliance
0
1
0
1
15
4
5
0
3
1
0
3
1
0
3
1
0
3
1
S.N
Attributes
Specific Conditions
21
22
Compliance
Non-Compliance
23
Compliance
Non-Compliance
3
3
3
Compliance
Non-Compliance
0
1
30
5
100
Final Evaluation
S.N
Building Category
Criteria
Conclusion
Good
Average
Poor
Total Vulnerability Score>30 Or/ And NonCompliance of any one Mandatory Statement
OR have not information of any statements
Recommended Action
Registration Nos.:
Contact No:
Date:
Note: 1) All the provisions need to be assessed using architerctural as well as structural drawings with some quick
calcualtions wherever applicable.
2) The specific condition for assessed building in corresponding provision need to be highlighted.
S.N Mandatory Attributes
Specific Conditions
Recommendation
1
Grade of Concrete
Size of Column
Soft Storey
S.N
Compliance
Non-Compliance
Compliance
Non-Compliance
Compliance
Non-Compliance
Attributes
Specific Conditions
Vulnerability Weightage
Factor (v)
(w)
0
0.5
1
0
0.5
1
0
1
0
0.75
1
0
0.25
0.5
1
0
0.25
0.5
1
0
1
0
0.5
0.25
1
0
0.25
0.5
3
4
1
0
6
1
0
0.25
0.75
0.5
1
50
S.N
Attributes
Compliance
Non-Compliance
Mc1.1Mb
Strong Column Weak
13
Beam
Mc<1.1Mb
Compliance
14 Shear Stress In Column
Non-Compliance
12 Size of Beam
Specific Conditions
Vulnerability Weightage
Factor (v)
(w)
0
1
0
1
0
1
4
6
5
15
S.N
Attributes
Specific Conditions
Vulnerability Weightage
Factor (v)
(w)
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
4
5
3
3
3
3
3
3
3
0
1
30
5
100
E
1
2
Good
Average
Poor
Recommended Action
Criteria
Conclusion
Vulnerability
Score(v*w)
Vulnerability
Score(v*w)
Vulnerability
Score(v*w)
Conclusion