10/100/1000
100/1000
MAN PWR
MAN PWR
DIS
DIS
LK
LB
FD
LK
LB
FD
ACT
ACT
CON
CON
SPD
SPD
LK
LK
2
ACT
ACT
This publication is protected by the copyright laws of the United States and other countries, with all rights reserved. No part of this
publication may be reproduced, stored in a retrieval system, translated, transcribed, or transmitted, in any form, or by any means
manual, electric, electronic, electromagnetic, mechanical, chemical, optical or otherwise, without prior explicit written permission
of Telco Systems, Inc.
Metrobility, Metrobility Optical Systems, and NetBeacon are registered trademarks of Telco Systems, Inc. All other trademarks
are the property of their respective owners.
The information contained in this document is assumed to be correct and current. The manufacturer is not responsible for errors
or omissions and reserves the right to change specifications at any time without notice.
2010 Telco Systems, Inc.
Printed in USA.
Contents
Chapter 1:
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Chapter 2:
Chapter 3:
Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Default Software Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Managed Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
MIB-II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Enterprise-Specific Objects . . . . . . . . . . . . . . . . . . . . . 23
Remote Management Statistics . . . . . . . . . . . . . . . . . . . . . . . . 23
Setting a Secure Management Channel . . . . . . . . . . . . . . . . . . 24
Software Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
IP Addressing Management . . . . . . . . . . . . . . . . . . . . . 26
Far End Fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Flow Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
ICMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Loopback Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Port Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Flow Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
ICMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Loopback Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Contents
Port Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Port State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Rate Limiting/Traffic Shaping . . . . . . . . . . . . . . . . . . . . 33
VLAN Tagging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Environmental Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Upgrading the Operating System Software . . . . . . . . . . . . . . . . 41
Chapter 4:
CLI Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Notation Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Complete List of Commands . . . . . . . . . . . . . . . . . . . . . . . . . 43
User Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Administrator Commands . . . . . . . . . . . . . . . . . . . . . . . 45
Root Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Clear Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
clear l2controlprotocol . . . . . . . . . . . . . . . . . . . . . . . . . 47
clear mgmtvlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
clear radiusserver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
clear snmpuser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
clear trapdestination . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
clear username . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
clear uservlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
System Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
arp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
change password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
download . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
logout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
ping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
run config . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Set Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
set cNodeLevel1Agent . . . . . . . . . . . . . . . . . . . . . . . . . 52
set console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
set dhcp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
set download . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
set fpga . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
set icmp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
set ip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
set jumbo-frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
set l2controlprotocol . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
set l3capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
set logicalservicesloopback . . . . . . . . . . . . . . . . . . . . . 55
set loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
set mgmtvlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
set oamcontrol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
set oamerrframe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
set oamerrframeperiod . . . . . . . . . . . . . . . . . . . . . . . . . 57
set oamerrframesecs . . . . . . . . . . . . . . . . . . . . . . . . . . 57
set oamerrsymperiod . . . . . . . . . . . . . . . . . . . . . . . . . . 58
set oamloopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
set os . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
set port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
set pvid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
set qinq . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
set radiusauthentication . . . . . . . . . . . . . . . . . . . . . . . . 60
set radiusretransmit . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
set radiusserver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
set radiustimeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
set ratelimit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
set scheduling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
set snmpcommunity . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
set snmpuser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
set snmpv1v2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
set switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
set systeminformation . . . . . . . . . . . . . . . . . . . . . . . . . 63
set trapcontrol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
set trapdestination . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
set username . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
set uservlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Show Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
show cablestatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Contents
show cNodeLevel1Agent . . . . . . . . . . . . . . . . . . . . . . . 66
show console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
show dhcp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
show download . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
show fpga . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
show icmp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
show ip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
show jumbo-frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
show l2controlprotocol . . . . . . . . . . . . . . . . . . . . . . . . . 68
show l3capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
show logical servicesloopback . . . . . . . . . . . . . . . . . . . 69
show mgmtvlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
show oamcontrol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
show oameventlog . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
show oamevents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
show oamloopback . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
show oampeer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
show oamstatistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
show os . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
show port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
show portstatistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
show pvid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
show radius . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
show ratelimit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
show rmonportstatistics . . . . . . . . . . . . . . . . . . . . . . . . 82
show scheduling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
show sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
show snmpcommunity . . . . . . . . . . . . . . . . . . . . . . . . . 84
show snmpuser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
show snmpv1v2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
show switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
show systeminfo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
show trapcontrol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
show trapdestinations . . . . . . . . . . . . . . . . . . . . . . . . . 86
show usernames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
show uservlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
show weights-profile . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Chapter 5:
Chapter 6:
Contents
Chapter 1: Overview
The feature-rich Metrobility R861 Gigabit Ethernet Services Line cards
are two-port network interface devices(NID) designed for superior
manageability. The R861-1S provides a 10/100/1000BASE-T access port
and a small form-factor pluggable (SFP) 100/1000BASE-X network port
with numerous wavelength and distance options (The default setting is
1000Base-X). The R861-SS has ports for two SFPs. This device is ideal
for environments that are gradually migrating toward GbE. The R861
includes a third console port for direct management.
The R861 supports jumbo frames up to 10240 bytes and auto-negotiation. When auto-negotiation is enabled, the copper port on the R861-1S
auto-detects MDI-II/MDI-X1. Both ports also support flow control (forced
collisions in half duplex and PAUSE frames in full duplex).
Management software for the R861 can be downloaded in the field for
future updates. Two different versions for both the operational software
and the FPGA firmware may be stored on the device, along with two
separate configuration files.
Advanced management capabilities and diagnostics include Metrobilitys
patent-pending Logical Services Loopback (LSL), include temperature
and voltage monitoring, interface control enable/disable, a built-in optical
power meter, loopback testing, Link Loss Carry Forward, Link Loss
Return, and Far End Fault to assist in troubleshooting.
Overview
100/1000
10/100/1000
DIS
DIS
MAN PWR
LK
LB
FD
MAN PWR
LK
LB
FD
ACT
ACT
CON
CON
SPD
SPD
LK
LK
2
ACT
ACT
Key Features
Note: The R861-1S and R861-SS have SFP fiber ports capable of both
100M and 1000M. The default speed setting for the fiber port is 1000M.
To change the port speed to 100M please reference the 'set port speed'
section on page 59.
The Metrobility services line cards provide the following key features:
Hardware
Overview
DIP switch control over auto-negotiation, Link Loss Carry Forward (LLCF),
and Link Loss Return (LLR).
Software
Interoperable with the Metrobility SNMP, CLI, TFTP, and telnet access
mechanisms.
Overview
10
Storage for two versions of the operating system and FPGA firmware as
well as two separate configuration files.
Overview
11
Chapter 2: Installation
Guide
Safety Warning
Installation Guide
12
R861-1S
LLR2
LLCF2
LLR2
LLCF2
LLR1
LLCF1
1 2 3 4 5 6
AN1
SPD1
LLCF1
DOWN
UP
DOWN
UP
1 2 3 4 5 6
R861-SS
AN1
Dip Switch
Name
Autonegotiation
Position
Function
SPD1
LLCF1
Link Loss
Carry
Forward
LLR2
LLCF2
Link Loss
Return
Link Loss
Carry
Forward
UP
DOWN
(default)
UP
DOWN
(default)
UP
DOWN
(default)
13
LLR1
LLCF1
LLR2
LLCF2
R861 Switches
Dip Switch
Name
Link Loss
Return
Link Loss
Carry
Forward
Link Loss
Return
Link Loss
Carry
Forward
Position
UP
DOWN
(default)
Function
Link Loss Return is enabled. If Port 2
loses its receive link then it will disable
its own transmitter.
Link Loss Return is disabled.
UP
DOWN
(default)
UP
DOWN
(default)
UP
DOWN
(default)
Installation Guide
14
transmit idle link signals. When LLCF is disabled (default), the card
continuously transmits idle link signals. The switch enables/disables
LLCF on both ports simultaneously. Refer to the in the User Guide
section for additional information.
CLOSED
BAIL LATCH
POSITION
SFP
DO NOT
OPEN
BAIL LATCH
15
To install the optics, align the SFP module so the receiver (s) is
positioned above the transmitter (t). For a BWDM module, align it so the
visible part of the circuit board located at the back of the module is to the
right. Slide the module into the empty slot. Push the SFP firmly in place.
10/100/1000
DIS
MAN PWR
LK
LB
FD
ACT
CON
SPD
LK
2
TX
RX
ACT
Important: The Metrobility services line cards are designed and tested
to operate using only Telco Systems supplied SFP transceivers. Safety,
performance, and reliability are guaranteed only when Telco Systems
supplied transceivers are used. Installing unspecified parts may
damage the product and will void the units warranty.
Installation Guide
16
Metrobility
Card Guide
MAN PWR
LK
CON
ACT
LB
DIS
FD
LK
SPD
ACT
10/100/1000
Insert the card into a slot in the chassis. Make sure that the edges of
the board are aligned with the card guides in the chassis. Do not force
the card into the chassis unnecessarily. It should slide in easily and
evenly.
Slide the card in until the top and bottom edges of the front panel are
flush and even with the edges of the chassis.
To secure the card to the chassis, turn the thumbscrew clockwise until
it is snug. The card is now properly installed and ready for connection
to the network.
DIS
FD
LK
SPD
ACT
10/100/1000
LK
CON
ACT
17
Twisted-Pair Interface
The twisted-pair port, Port 1, provides a shielded RJ-45 connector that
supports a maximum segment length of 100 meters.
Installation Guide
18
BWDM Interface
The bidirectional wavelength division multiplexed (BWDM) transceivers
provide one singlemode SC connector that supports a maximum
segment length of 10 or 40km. BWDM transceivers must always be used
in complementary pairs. For example: the O311-10-31 must be
connected to the O311-10-49. The O311-10-31 transmits data at a
wavelength of 1310 nm and receives at 1490 nm. Correspondingly, the
O311-10-49 transmits data at 1490 nm and receives at 1310 nm.
Use the link (LK) LEDs on the front panel of the card to verify correct
segment connectivity. As you insert the cable into each port, the LK LED
will be lit if the following conditions are met:
Power is being applied to the chassis.
There is an active device connected to the other end of the cable, and
it is sending idle link signals.
All connections are secure and the cables are undamaged.
Both ends of the cable are set to the same auto-negotiation state. To
maximize device compatibility, the R861 is shipped with auto-negotiation enabled on both ports. If necessary, disable auto-negotiation and
set full duplex on the fiber port of the remote device to establish link.
For information on replacing the SFP transceiver, refer to in the User
Guide section.
19
Metrobility
MAN PWR
RX
DIS
FD
LB
LK
SPD
ACT
10/100/1000
LK
CON
ACT
Installation Guide
20
21
Chapter 3: Management
This section contains information regarding the management and
software configuration options available on the Metrobility R861 Gigabit
Ethernet services line cards.
Management
22
Managed Objects
MIB-II
The Metrobility R861 Gigabit services line cards support the following
standard Management Information Base (MIB-II) managed object
groups, pertaining only to the end-station traffic. Objects from within
these MIB groups are accessible by and available to SNMP-based
management stations over UDP/IP.
23
EnterpriseSpecific
Objects
Management
24
etherStatsPkts
etherStatsMulticastPkts
etherStatsUndersizePkts
etherStatsJabbers
etherStatsPkts64Octets
etherStatsPkts128to255Octets
etherStatsPkts512to1023Octets
etherStatsOversizePkts
RFC 3273
etherStatsHighCapacityOverflowPkts
etherStatsHighCapacityPkts
etherStatsHighCapacityOverflowOctets
etherStatsHighCapacityOctets
etherStatsHighCapacityOverflowPkts64Octets
etherStatsHighCapacityPkts64Octets
etherStatsHighCapacityOverflowPkts65to127Octets
etherStatsHighCapacityPkts65to127Octets
etherStatsHighCapacityOverflowPkts128to255Octets
etherStatsHighCapacityPkts128to255Octets
etherStatsHighCapacityOverflowPkts256to511Octets
etherStatsHighCapacityPkts256to511Octets
etherStatsHighCapacityOverflowPkts512to1023Octets
etherStatsHighCapacityPkts512to1023Octets
etherStatsHighCapacityOverflowPkts1024to1518Octets
etherStatsHighCapacityPkts1024to1518Octets
25
Network Port
Console Port
Management
26
Configuration Description
Vulnerabilities
No Management
VLAN
No security. Any device connected to
(both ports)
either port can manage the R861.
DEFAULT
SETTING
The following table describes the misuses that could cause denial of
service when using reserved multicast protocols along with the various
management configurations.
27
Vulnerabilities
Management VLAN
(single port) with
Denial of service through misuse of reserved multicast traffic.
reserved multicast
No Management
VLAN (single port)
with reserved
multicast
Management VLAN Denial of service through misuse of reserved multicast, unicast MAC
(both ports) with
address, or broadcast on the specified management VLAN if the
reserved multicast access port is also a member.
No Management
VLAN (both ports)
with reserved
multicast
Software Settings
Several functions and settings on the Metrobility GbE services line cards
can be modified only through software commands. This section
describes the cards management features including IP addressing
management.
IP Addressing
Management
You can configure the R861 to obtain its IP addressing information (IP
address, network mask, and default gateway) through any of the
following means:
DHCP assignment
Manual configuration
Default value
DHCP Assignment
By default, the R861 has DHCP enabled for obtaining its IP addressing
information. When DHCP is enabled, the R861 enters a discovery mode
to locate a DHCP server. The card makes up to three3 attempts to
resolve its IP addressing information. If any of the attempts is successful,
the card will use the information assigned by the DHCP server. The card
will also save the DHCP servers IP address along with the address
lease time. Once the addressing information is acquired, the R861
preserves it in memory and renews it continuously. However, the
3.The max number of retires is configurable. The retry count starts at 4 seconds and doubles for each additional retry (1 = 4 seconds, 2 = 12 seconds, 3 = 28 seconds, 4 = 60 seconds, 5 = 124 seconds)
Management
28
Manual Configuration
Regardless of the DHCP setting, IP addressing information can be
assigned manually. When manually entering the IP addressing information via SNMP, you must also apply the changes by setting mosAdminApplyIPChanges to 1 in the METROBILITY-ADMIN-MIB. The R861 will
verify that the information you entered is valid and begin using the new
values if there are no problems. If for any reason there is a conflict, the
R861 will send a generic SNMP error.
Saving the IP information across power cycles depends on the DHCP
setting:
If DHCP is enabled, the R861 will enter the discovery mode at each
power cycle and attempt to obtain new IP addressing information. The
manually configured information will be maintained across a power
cycle only until a DHCP server assigns it a new IP address, or until
someone manually enters the IP addressing information again.
Default Value
To return the R861s IP address, network mask, and gateway back their
factory defaults, reset to defaults using CLI, SNMP or WebBeacon.
Resetting the board using this method forces all software settings back to
their original values.
29
Start-up Failure
During the initial discovery mode, if a DHCP server is not found within the
timeout period4, the R861 will generate its own IP address. Once an
address is generated, the R861 enters a probing phase to verify that the
address is unique. If the address is identical to one previously claimed by
another device, the R861 will generate a new address repeatedly until it
is successful.
Note: Do not send ARP requests (pings) to the R861 during its initialization. All ARP requests received during the probing phase5 are interpreted as address collisions and discarded. If a collision occurs, the
R861 will immediately discard the address it is verifying and generate
another one.
If DHCP is enabled, every five minutes following a successful selfgenerated address assignment, the R861 will attempt to acquire its
addressing information by locating a DHCP server.
If DHCP is disabled, the R861 will maintain its last known IP addressing
information regardless of how the information was acquired, even if it
was self-generated.
Far End Fault (FEF) is only applicable to fiber ports. FEF allows a
management station to receive notification of a failure in the remote
R861s fiber port receiver when two services line cards are connected
through their fiber ports. When FEF is enabled, the local R861 will send
an SNMP alarm to its trap destination(s) if a far end fault condition is
detected. No alarm will be sent if the condition occurs but FEF is
disabled. FEF works in conjunction with auto-negotiation. This means
that for FEF to function properly, auto-negotiation must be enabled on
both ends of the fiber link when FEF is enabled.
Flow Control
Management
30
Full-Duplex Flow
Control Settings
Auto-Negotiation
Full-Duplex Flow
Control
Disabled
Disabled
Disabled
Disabled
Enabled
ICMP
31
Loopback
Modes
Local Loopback
Remote Loopback
OAM Loopback
Logical Services Loopback
Once loopback is enabled, the R861 can be taken out of loopback using
one of the following means:
Software commands.
A reset or full power cycle of the card.
Removing the card and then reinserting it into the chassis.
Note: Loopback is not supported on Port 1. If you attempt to enable
loopback on Port 1, you will receive an error message.
Local Loopback
Local loopback is provided for testing link integrity on both ports of a
standalone R861 NID. When local loopback is enabled on the network
port, the port returns its incoming data back to the sender, while
continuing to receive and process management frames. Management
frames are not looped backonly data frames are returned. When local
loopback is enabled, the LBK LED is lit and the access port is disabled.
Local loopback is typically enabled to evaluate the network segment by
using standard packet-generating test equipment. During local loopback,
the incoming data is transmitted through the entire circuitry of the R861
board, not just the network port. This allows the entire circuit to be tested.
Management
32
RMON statistics are incremented on the ingress port, even though the
physical interface of the access port is neither transmitting nor receiving
traffic.
Local
Device
Test
Equipment
R861
NID
Remote
Device
Network Port
Access Port
X
Remote Loopback
Remote loopback is only applicable when two R861 cards are in a backto-back configuration and they are being managed by the R502-M
management card. Remote loopback is performed on the network port of
the remote R861. When remote loopback is enabled, the remote network
port returns its incoming data back to the sender, while continuing to
receive and process management frames. Management frames are not
looped backonly data frames are returned. During remote loopback,
the LBK LED on the remote R861 is lit and its access port is disabled.
The LBK LED on the local R861 remains off.
Remote loopback only can be enabled on either port of the remote R861.
It is typically enabled to evaluate the data flow using standard packetgenerating test equipment, as shown in the illustration below. During
remote loopback, the incoming data is transmitted through the entire
circuitry of the remote R861 board, not just its network port. This allows
the entire circuit to be tested. RMON statistics are incremented on the
ingress port, even though the physical interface of the remote access
port is neither transmitting nor receiving traffic.
Local
Device
Test
Equipment
Remote
R861
Local
R861
Access Port
Remote
Device
Access Port
Network Port
X
33
OAM Loopback
OAM loopback is only applicable to when two R861 services line cards
are in a back-to-back configuration with both cards connected through
their network ports. By using the 802.3ah management channel, OAM
loopback is initiated from the local R861 and performed on the remote
R861. During OAM loopback, data on the fiber line is looped at the
remote R861, returned to the local R861, and terminated there.
Because the data stream is stopped at the local R861, you do not need
any external test equipment to determine the quality of the network
segment. Instead, you can simply view the counters for the two services
line cards to see if the data is passing properly.
Local
Device
Access
Network
Access
Remote
Device
Remote R861
Services Line Card
Local R861
Services Line Card
The OAM mode must be active on the local R861s network port
because it is the port that initiates loopback.
The network port on both the local and remote R861 must be in fullduplex mode. (OAM is not supported on half-duplex links.)
Management
34
48+
Preamble
SFD
Source
Dest
MAC Addr MAC Addr
data
FCS
Preamble
SFD
Source
Dest
MAC Addr MAC Addr
data
FCS
Recalculated
Sets the new source address to the R861s Loopback MAC address
(shown in blue).
Calculates the new Frame Check Sequence (FCS) and replaces the
existing FCS with the new value at the end of the frame, which is then
transmitted back to the sender.
35
Access
Remote
Device
Remote R861
Services Line Card
Local R861
Services Line Card
Network
Access
Port
Management
Port State
You can independently enable or disable the port state on either port on
the services line card. Disabling the port state stops the flow of data to
and from that port. Although data is neither sent nor received, the
disabled port continues to accept, process, and transmit management
frames. However, if LLCF is enabled and the opposite port has no link,
management frames will not be transmitted.
Rate Limiting/
Traffic Shaping
By default, each port allows data to flow at full line speed. The R861
supports bandwidth management that allows you to restrict the data rate
independently on each port. Bandwidth management consists of three
parts: direction (ingress/egress), rate and state, all of which are configurable. Ingress defines the ratelimit of the traffic into the port. Egress
defines the traffic shaping of the traffic exiting the port.
The rate can be set to a value between 64kbps to 1000Mbps. The state
activates or cancels rate limiting. When the rate limiting state is disabled,
the data flows without any restrictions as fast as the link allows, even if
the rate is configured to a slower setting. When rate limiting is enabled,
the data entering the given port is limited to the defined rate. Port 1 and
Port 2 can be set to different rates.
Rate limit ranges (egress):
Management
36
VLAN Tagging
Transparent
IEEE 802.1Q
Q-in-Q
VLAN tagging only applies to egress traffic in Q-in-Q and IEEE 802.1Q
mode. This mode operates under an inclusive model, and one port must
be designated as the trunk port and other as the access port. By default,
the access port is Port 1 and the trunk is Port 2. All egress traffic from
both ports are tagged, with the exception of PVID-tagged frames
received on the trunk port. Those frames egress from the access port as
untagged frames. Untagging specific user VLANs can be configured on
the access port only. VLAN tagging and untagging rules are described in
detail under Q-in-Q Mode on page 33 and IEEE 802.1Q Mode on
page 31.
The diagram below shows the VLAN tag format:
Tag Control Info
(2 bytes = 8100)
P-Bits
(3 bits)
Canonical Indicator
(1 bit = 0)
VID
(12 bits)
IEEE 802.1Q mode requires a port VLAN identifier (PVID). The default
PVID is 1. The PVID is configurable and assigned as part of a VLAN tag
to untagged frames, thus allowing untagged traffic to participate in VLAN
assignments. When the PVID is configured, it is applied to both ports and
is persistent through device resets (i.e., the PVID is changed only when
modified via software commands).
In addition to the PVID, a VLAN tag includes three priority bits. For
VLAN-tagged frames forwarded by the R861, the priority bits are either
set to 0 or unchanged from their original value.
Configuring the PVID alone, without enabling IEEE 802.1, will not alter
traffic. To activate VLAN tagging, you must do the following:
1. Specify the bridge forwarding mode using the set switch command.
37
2. Specify the port VLAN identifier using the set pvid command, if you
want to use a number other than the default PVID value of 1. This
command also allows you to change the access port to Port 2.
3. Configure up to 16 user VLANs using the set uservlan command.
This command also allows untagging on the access port on a perVLAN basis.
Management Frames
The bridge forwarding mode does not affect the processing of 802.3ah
OAM management frames. They are always delivered to, and processed
by, the R861s CPU. OAM frames are never tagged.
If the management channel is untagged, IP-based management frames
must also be untagged.
If the management channel is VLAN-tagged, IP-based management
frames must be tagged with the configured management VLAN.
If management is disabled on a port, VLAN-tagged management frames
at that port will be discarded.
For information about how management frames are processed in Q-in-Q
mode, refer to Q-in-Q Mode on page 33.
Transparent Mode
Transparent mode is the default setting. In this mode, all tagged and
untagged user frames are forwarded without any modifications. All
untagged Layer 2 control protocols are also forwarded transparently,
however, these frames may be discarded on a per-protocol basis.
The following example illustrates how frames are forwarded in transparent mode. The untagged frame (light blue) is forwarded as an
untagged frame, and the tagged frame (dark blue) with a VLAN ID of 25
is forwarded without any changes. Traffic in both directions is handled in
the same manner.
Transparent Mode
R861
untagged
tagged
25
untagged
Access
Trunk
Port
Port
tagged
25
Management
38
Native VLANs
An internal native VLAN is used to process untagged user frames and
management frames when the management VLAN is not configured. The
native VLAN is set to the PVID, which by default is 1. Changing the PVID
automatically changes the native VLAN.
In transparent mode, the R861 internally processes all untagged frames
it receives by adding the native VLAN to the frame. Before the frame is
transmitted out the opposite port, the native VLAN is removed, thus
keeping the frame untagged. This means any user or management frame
that contains the native VLAN will have the tag removed before it
egresses. To prevent the R861 from incorrectly stripping off a tag, you
must make sure you are not using the native VLAN. For example, if you
use VLAN 1, the PVID must be set to a value other than 1, because if the
PVID is not changed, all frames with VLAN 1 will egress as untagged
frames.
Untagged Layer 2 control protocols (L2CP) are forwarded transparently, however, these frames may be discarded on a per-protocol
basis.
39
untagged
untagged L2CP
Access
Port
PVID = 2
user VLAN
= 10-25
Trunk
Port
tagged (p-bits=0)
2
untagged L2CP
tagged
25
tagged
25
priority-tagged
0
dropped
26
tagged (p-bits=original)
2
tagged
26
Management
40
untagged L2CP
untagged
PVID = 2
Access
Port
user VLAN
= 10-25
untag = 10 & 11
tagged
25
untagged
dropped
untagged L2CP
Trunk
Port
tagged w/PVID
2
tagged
25
tagged
11
untagged
untagged
priority-tagged
0
priority-tagged
0
tagged
26
tagged
26
Q-in-Q Mode
To extend the VLAN space available under 802.1Q mode, the R861
supports the tagging of tagged frames. This results in a double-tagged
frame that becomes available for use in the service provider or Q-in-Q
domain. Double tagging preserves the original tag and applies a second
VLAN tag that is removed when the frame exits the Q-in-Q domain.
Traffic forwarding in this mode depends on whether a frame arrives at the
access port or the trunk port. The trunk port serves as the interface to the
Q-in-Q domain. VLAN tagging rules for each port are detailed below.
Environmental Sensors
Through software, you can view environmental sensor information for
monitoring the health of the services line cards. Each sensor reading
includes the current value along with the minimum and maximum values
for the component. To prevent a potential problem, a trap can be set so a
network manager is notified whenever any sensor threshold is crossed.
For more information on traps, refer to Traps on page 87.
Module Sensors
41
There are five module sensors. Module sensors measure the main circuit
boards temperature as well as the voltage for the line cards 1.2, 2.5, 3.3,
and 5.0 volt power supplies. The 5.0 volt supply is the input power source
for the services line card. The other supplies are used to power various
components on the circuit board. The module temperature sensor has an
accuracy of 3 C. The voltage monitoring accuracy is 1%.
Port Sensors
The R861 includes three SFP sensors for each fiber port. Information is
provided only when an SFP transceiver which supports diagnostics is
installed. One sensor provides the internal port temperature. The other
two sensors provide the optical receive and transmit power levels for the
fiber port. The accuracy of the RX and TX monitors is typically 1 dBm.
Management
42
3.
When the value of mosDownloadStatus is flashBurnComplete(4), set mosDownloadActiveOSImage to the location just loaded to. That is, 3 if it was loaded to the primary
location, or 4 if it was the secondary location.
4.
43
User (user/user)
Administrator (admin/admin)
Root (root/root)
The list of commands available to each user account is cumulative. That
is, the Administrator account includes all User commands, and the Root
account includes all commands.
Note: For any CLI command, you can start typing the first few letters
and then press the Tab key to complete the rest of the command. There
must be enough letters entered to make the command unique.
Notation Conventions
This chapter uses the conventions described in this section.
Font Conventions
Arial
Times This font is used for program examples, prompt responses, and
other system output.
[Key]
Symbol Conventions
< > Angle brackets indicate that the enclosed information is a required
field.
[]
CLI Commands
44
it is a key to press.
|
A vertical bar separating two or more text items indicates that any
one of the terms may be entered as a value.
arp
change password
exit
help
logout
ping
show cable status command
show cNodeLevel1Agent
show console
show dhcp
show download
show fpga
show icmp
show ip
show jumbo-frames
show l2controlprotocol
show l3capability
show logicalservicesloopback
show mgmtvlan
show oamcontrol
show oameventlog
show oamevents
show oamloopback
show oampeer
show oamstatistics
show os
show port
show portstatistics
show pvid
show radius
show rate limit command
show rmonportstatistics
45
show scheduling
show sensors
show snmpuser
show snmpv1v2
show switch
show systeminfo
show trapcontrol
show trapdestinations
show uservlan
show weights-profile
Administrator
Commands
clear l2controlprotocol
clear mgmtvlan
clear radiusserver
clear uservlan
download
reset
run config
set cNodeLevel1Agent
set console
set dhcp
set download
set fpga
set icmp
set ip
set jumbo-frames
set l2controlprotocol
set l3capability
set logicalservicesloopback
set loopback
set mgmtvlan
set oamcontrol
set oamerrframe
set oamerrframeperiod
set oamerrframesecs
set oamerrsymperiod
set oamloopback
set os
set port
set pvid
CLI Commands
46
set qinq
set radiusauthentication
set radiusretransmit
set radiusserver
set radiustimeout
set rate limit command
set scheduling
set switch
set systeminformation
set trapcontrol
set uservlan
set weights-profile
Root
Commands
clear snmpuser
clear trapdestination
clear username
set snmpcommunity
set snmpuser
set snmpv1v2
set trapdestination
set username
show snmpcommunity
show usernames
47
Clear Commands
clear
l2controlprotocol
clear mgmtvlan
clear
radiusserver
clear snmpuser
clear
trapdestination
CLI Commands
48
Console>
clear username
Description:
Syntax:
Parameters:
Example:
clear uservlan
Description:
Syntax:
Parameters:
Example:
System Commands
arp
49
1 192.168.1.10000:00:d0:6a:57:b410800 RESOLVED
permanent
1 192.168.1.10100:01:d0:6d:02:0010800 RESOLVED
1 192.168.1.10200:01:5a:98:52:8010800 RESOLVED
1 192.168.1.10300:01:5a:9a:fd:5810800 RESOLVED
548 s
576 s
582 s
Console>
change
password
download
Description: Download the operating system, FPGA firmware, configuration script, or boot code. The OS and FPGA files will be
downloaded into the inactive location. For a configuration
file, the location must be specified. If you download new
boot code, it will overwrite the existing code.
Note: The download server must first be identified using
the set download command before this command
can be executed. Refer to set download on page 53
for more information.
Syntax:
download <os | fpga | config1 | config2 | boot> [set | reset |
defaults]
Parameters: os operating system.
fpga FPGA embedded software.
config1 configuration script/file instance 1.
config2 configuration script/file instance 2.
boot bootloader software.
set set the newly downloaded OS or FPGA software as
active.
reset set the newly downloaded OS or FPGA software as
active and reset the card.
defaults set the newly downloaded OS or FPGA software
as active and reset the card to its factory default
settings.
Example:
Console> download config1
Console> Transferring file config1.txt
Writing image to Z80 internal FLASH
FLASH verification in progress.
CLI Commands
50
exit
Description:
Syntax:
Parameters:
Example:
help
Description: Show all commands that are available to the user, along
with a brief description of the command, or all available
commands that begin with a specified word. Optionally,
press the [Tab] key to display only the commands available
to your user account. No descriptions are provided when
you use the [Tab] option.
Syntax:
help [command]
[Tab]
Parameters: command a one-word command
Example:
Console> help
arp [all] [delete <IP address>] [static <IP address> <MAC
address>]
Show, add and delete arp entries.
:
show uservlan <vlan id | all>
Show user VLAN IDs (1-4094) on one or more ports.
Console> help ping
ping <host> [count <count>] [size <size>] [delay <delay>]
Send ICMP echo (ping) packets.
Console>
logout
Description:
Syntax:
Parameters:
Example:
ping
Log off.
exit
None.
Console> exit
Log off.
logout
None.
Console> logout
51
reset
run config
CLI Commands
52
Set Commands
set
cNodeLevel1Ag
ent
set console
set dhcp
53
set download
set fpga
Description:
Syntax:
Parameters:
Example:
set icmp
set ip
CLI Commands
54
set jumboframe
set
l2controlprotocol
55
set l3capability
set
logicalservices
loopback
set loopback
set mgmtvlan
CLI Commands
56
Syntax:
set mgmtvlan <vlan id>
Parameters: vlan id VLAN ID in the range 1 to 4094. To disable
management VLAN, set the ID to 0.
Example:
Console> set mgmtvlan 1070
Console>
set oamcontrol
set
oamerrframe
57
set
oamerrframeperiod
set
oamerrframesecs
Description: Set the OAM event attributes for number of errored frames
detected for a set frame count window for the specified
port, and enable or disable notification.
Syntax:
set oamerrframeperiod <port number> [window <number
of frames>] [threshold <frame threshold>] [notify <enable |
disable>]
Parameters: port number the actual port number.
window Number of frames over which the threshold is defined.
The range is 148,809 to 89,285,714.
threshold The number of frame errors that must occur for
the Errored Frame Period Event to be triggered.
Example: If window = 1,000,000 and threshold = 2,
then if 2 frames out of 1,000,000 frames have errors,
an Event Notification OAMPDU will be generated
with an Errored Frame Period Event TLV indicating
that the threshold has been crossed.
notify Enable or disable notification to the specified ports
OAM peer that the Errored Frame Period Event has
been triggered.
Example:
Console> set oamframeperiod 2 window 1000000
threshold 2
Console>
Description: Set the OAM event attributes for detection of number of
seconds with errored frames for a set time window (100
ms granularity) for the specified port, and enable or disable
notification.
Syntax:
set oamerrframesecs <port number> [window <# of 100
ms counts>] [threshold <frame secs threshold>] [notify
<enable | disable>]
Parameters: port number the actual port number.
window The amount of time (in 100 ms intervals) over
which the threshold is defined. The range is 100 to
9000.
threshold The number of errored frame seconds that must
occur for the Errored Frame Seconds Summary Event
to be triggered. The threshold range is 1 to 900.
Example: if window = 100 and threshold = 5, then if 5
frame errors occur within a window of 10 seconds, an
Event Notification OAMPDU will be generated with an
Errored Frame Seconds Summary Event TLV
indicating the threshold has been crossed.
notify Enable or disable notification to the specified ports
OAM peer that the Errored Frame Seconds
Summary Event has been triggered.
Example:
Console> set oamerrframesecs 1 window 100 threshold 5
Console>
CLI Commands
58
set
oamerrsymperiod
set
oamloopback
Description: Start or stop remote loopback on the specified port with the
remote OAM port.
Syntax:
set oamloopback <port number> status <start | end>
[commands <ignore | process>]
Parameters: port number the actual port number.
status initiate or terminate remote loopback with the
remote port. Starting remote loopback causes the
specified port to send a loopback OAMPDU (with the
loopback enable flags set) to the remote port. Ending
remote loopback causes the specified port to send a
loopback OAMPDU (with the loopback enable flags
cleared) to the remote port.
commands process or drop incoming requests for
loopback when the specified port receives them.
Example:
Console> set oamloopback 2 status end
Console>
set os
59
Example:
Console> set os 1
OS1 image (1.2.0) will become active until next reset.
Console>
set port
set pvid
Description: Set the port VLAN identifier that will be used for tagging when
the IEEE 802.1Q forwarding mode is enabled. When the
switch mode is set to Transparent, the PVID is used as the
native VLAN for untagged frames.
Syntax:
set pvid <VLAN> [access <port number>]
Parameters: VLAN VLAN ID in the range 1 to 4094.
access specifies the access port. If not specified, the
access port will be the port that was last configured
to be the access port. By default, the access port is
Port 1.
Example:
Console> set pvid 3
Console>
CLI Commands
60
set qinq
set
radiusauthentication
61
Console>
set
radiusretransmit
set
radiusserver
set
radiustimeout
set ratelimit
CLI Commands
62
Example:
set scheduling
Description: Set the 4 egress queues (0,1,2,3) for each port to one of
the following egress modes (Weighted Round Robin
[WRR], Strict Priority [SP], hybrid-1 or hybrid-2). Default is
WRR.
Queue priorities:
Highest 3
Lowest 0
Syntax:
set scheduling [mode <SP | HYB-1 | HYB-2 | WRR>]
[weights-profile <1-15>]
Parameters: mode
SP (Strict Priority)
HYB-1 (Hybrid-1, TX queue 3 is set to SP and the
remaining TX queues are set to WRR.)
HYB-2 (Hybrid-2, TX queue 3 & 2 are set to SP and
the remaining TX queues are set toWRR.)
WRR (Weighted Round Robin)
weights-profile - Set the weights-profile to one of the
following:
1 1 1 1 1 6 1 2 2 4 11 4 2 1 1
2 1 1 1 2 7 1 2 4 4 12 2 2 2 1
3 1 1 2 2 8 1 2 4 8 13 4 2 2 1
4 1 1 2 4 9 2 1 1 1 14 4 4 2 1
5 1 2 2 2 10 2 2 1 1 15 8 4 2 1
Example:
set
snmpcommunity
63
set snmpuser
Description:
Syntax:
Parameters:
Example:
set snmpv1v2
Description:
Syntax:
Parameters:
Example:
set switch
Description:
Syntax:
Parameters:
Example:
Set the name along with the authentication and privacy parameters for
SNMPv3 access.
set snmpuser <user name> auth <none | md5> [authpwd <auth
password>] priv <none | des> [privpwd <priv password>] group
<ro | rw | admin>
user name a case-sensitive ASCII string (up to 31 characters in
length) denoting the user name that has SNMPv3 access to
the device.
auth identifies the authentication protocol.
none No authentication is performed.
md5 MD5 protocol is used to encrypt the authentication
process. This option requires an authentication password.
auth password a case-sensitive ASCII string (up to 31
characters in length) denoting the password associated
with the user when MD5 authentication is specified.
priv identifies the privacy protocol.
none No privacy. Messages are not encryted.
des Messages sent by the user are encrypted using the
DES protocol. This option requires a privacy password.
priv password a case-sensitive ASCII string (up to 31 characters
in length) denoting the password associated with the user
when the DES protocol is specified for encrypting
messages.
group specifies the access profile for the SNMPv3 user.
ro read-only access to non-privileged objects.
rw read-write access to non-privileged objects.
admin full read-write access to all objects.
Console> set snmpuser v3guest auth none priv none group ro
Console>
Enable or disable SNMPv1 and SNMPv2c access.
set snmpv1v2 <enable | disable>
enable enable SNMPv1 and SNMPv2c access.
disable disable SNMPv1 and SNMPv2c access.
Console> set snmpv1v2 enable
Console>
Specify the forwarding mode.
set switch <Transparent | 802.1Q>
Transparent specifies transparent forwarding. The R861 is
completely transparent to user data traffic.Tagged and
untagged frames are forwarded unchanged.
Note: When Transparent is selected, the R861 uses an internal
native VLAN for untagged frames. The native VLAN is 1 by
default and can be modified by changing the PVID.
802.1Q specifies that the R861 complies with IEEE 802.1Q
VLAN bridge forwarding aspects. Untagged frames are
tagged with the PVID on the trunk egress port. Up to 16
user VLANs are supported. All other frames are discarded.
Console> set switch transparent
Console>
CLI Commands
64
set systeminformation
Description:
Syntax:
Parameters:
Example:
set trapcontrol
Description:
Syntax:
Parameters:
Example:
set trapdestination
Example:
65
set username
Description: Set the username, password, and access for user login.
Syntax:
set username <user name> password <user password>
access <user | admin | root>
Parameters: user name a case-sensitive, printable ASCII string up to
32 characters in length.
user password a case-sensitive, printable ASCII string
up to 32 characters in length.
access specifies the access level for a user login.
user read-only access to non-privileged objects.
admin read-write access to non-privileged objects.
root full read-write access to all objects.
Example:
Console> set username guest password guest access
user
Console>
set uservlan
Description: Set the user VLAN ID on one or more ports. (The R861
requires both ports to be set to the same user VLAN(s).)
The user VLAN ID must be different from previously provisioned management VLAN ID(s). Up to 16 user VLANs are
supported.
Syntax:
set uservlan <vlan id> port <port number[untag] ... [port
number n]>
Parameters: vlan id VLAN ID in the range 1 to 4094.
port number the port number to which the user VLAN is
assigned.
untag remove the specified uservlan tag from frames that
egress the access port. Untagging is not allowed on
the trunk port. Untagging is only applicable in IEEE
802.1Q mode.
Example:
Console> set uservlan 22 port 1untag 2
Console> set uservlan 23 port 1 2
Console>
CLI Commands
66
Show Commands
show
cablestatus
Description:
Syntax:
Parameters:
Display
Parameters:
Example:
Show results of the copper line quality test for copper port.
show cablestatus <port number>
port number the actual port number.
Good no problems are detected on the copper cable.
Open There is an open circuit along the copper cable.
Short There is a short circuit along the copper cable.
Impedance Mismatch There is an impedance mismatch
along the copper cable.
Console> show cablestatus 1
Copper Pair 1....: Good
Copper Pair 2....: Cable Open @ 30 Meters
Console>
show
cNodeLevel1Ag
ent
Description:
Syntax:
Display
Parameters:
Example:
show console
Console>
show dhcp
67
Display
Parameters: DHCP identifies the operational mode.
disabled DHCP client operation is disabled.
enabled DHCP client operation is enabled.
Retries specifies the number of address acquisition
retries before reverting to using the last known valid
IP address.
dhcp server IP address of the current DHCP server.
Example:
Console> show dhcp
DHCP Enabled
Retries: 3
DHCP Server: 192.168.1.100
Console>
show download
show fpga
Description: Show the image number and revision of the active FPGA
software.
Syntax:
show fpga
Example:
Console> show fpga
Active FPGA image number: 1
CLI Commands
68
Rev: 1.01.01
Console>
show icmp
show ip
show jumboframe
show
l2controlprotocol
69
Syntax:
show
l3capability
CLI Commands
70
Example:
show mgmtvlan
show
oamcontrol
Description: Show the primary controls and status for the 802.3ah OAM
capabilities for the specified port or all ports.
Syntax:
show oamcontrol <port number | all>
Parameters: port number the actual port number.
all specifies all ports.
Display
Parameters: Admin State indicates the desired administrative OAM
state for the specified port.
DISABLED OAM is in disabled.
ENABLED OAM is in enabled.
Note: The Admin State is ignored when the port is in fullduplex mode. OAM is supported on half-duplex links.
Operational Status identifies the OAM capability determined during initialization between the specified port
and its peer, which is the remote port on the opposite
end of the link.
DISABLED OAM is disabled administratively on
the specified port.
LINK FAULT The port has detected a fault and is
transmitting OAMPDUs with a link fault indication.
PASSIVE WAIT The port is in passive OAM mode
and is waiting to see if the remote port is capable of
OAM.
ACTIVE SEND LOCAL The port is in active OAM
mode and is trying to discover whether the remote
port has OAM capability but has yet made that determination.
SEND LOCAL AND REMOTE The port has
discovered its peer, but has yet accepted or rejected
the peers configuration.
71
Example:
CLI Commands
72
Console>
show
oameventlog
73
Example:
show
oamevents
CLI Commands
74
Example:
show
oamloopback
75
Example:
CLI Commands
76
show oampeer
Description: Show information about the OAM peer for the specified
port(s).
Syntax:
show oampeer <port number | all>
Parameters: port number the actual port number.
all specifies all ports.
Display
Parameters: MAC Address identifies the MAC address of the remote
port. The MAC address is derived from the most
recently received OAMPDU.
OUI identifies the remote ports Organizational Unique
Identifier (OUI). The OUI can be used for identifying
the vendor of the remote device.
Vendor Info indicates the vendor information of the
remote port as reflected in the latest Information
OAMPDU received.
Mode identifies the mode of OAM operation for the
remote port.
PASSIVE Remote port waits for the local port to
initiate OAM actions.
ACTIVE The remote port can initiate monitoring
activities with the local port.
Max PDU Size indicates largest OAMPDU that the
remote port supports. The remote port exchanges
maximum OAMPDU sizes with the local port, and
both ports negotiate to use the smaller of the two
maximum sizes between them.
Config Revision indicates the configuration revision of
the remote port as reflected in the latest OAMPDU
sent by the remote port. The configuration revision is
used to indicate configuration changes that have
occurred which might require the local port to reevaluate whether peering is allowed.
Supported Functions identifies OAM functions supported
by the remote port. One or more of the following
functions may be supported:
UNIDIRECTIONAL
LOOPBACK
EVENT
VARIABLE
Example:
Console> show oampeer 2
Port 2 Peer Information:
MAC Address . . . . . . : 00:00:00:00:00:00
OUI . . . . . . . . . . . . . . : 0 40 9f
Vendor Info. . . . . . . . : None
Mode . . . . . . . . . . . . : ACTIVE
Max PDU Size . . . . . : 1518
Config Revision . . . . : 1
77
show
oamstatistics
Description: Show show OAM statistics for the specified port (s).
Syntax:
show oamstatistics <port number | all>
Parameters: port number the actual port number.
all specifies all ports.
Example:
Console> show oamstatistics 1
Port 1 Information:
PDU Received: 0
PDU Transmitted: 98
Information Rcvd: 0
Information Transmitted: 98
Unique Event Notification Rcvd: 0Unique Event Notification Transmitted:
0
Duplicate Event Notification Rcvd: 0Duplicate Event Notification Transmitted: 0
Loopback Control Rcvd: 0 Loopback Control Transmitted: 0
Variable Requests Rcvd: 0 Variable Requests Transmitted: 0
Variable Responses Rcvd: 0Variable Responses Transmitted: 0
Org Specific Rcvd: 0
Org Specific Transmitted: 0
Unsupported Codes Rcvd: 0Unsupported Codes Transmitted: 0
Dropped Events: 0
Console>
show os
show port
CLI Commands
78
79
Example:
CLI Commands
80
Console>
show
portstatistics
Description: Show MIB-II interface statistics for one port or all three ports.
Syntax:
show portstatistics <port number | all>
Parameters: port number the actual port number.
all specifies all ports.
Display
Parameters: Octets Received number of octets received.
Unicast Packets Rcvd number of unicast packets
received.
Broadcast Packets Rcvd number of broadcast packets
received.
Multicast Packets Rcvd number of multicast packets
received.
Rcvd Packets Dropped number of received packets that
were discarded during reception.
Error Packets Rcvd number of packets received with
errors.
Octets Transmitted number of octets transmitted.
Unicast Packets Transmitted number of unicast packets
transmitted.
Broadcast Packets Transmitted number of broadcast
packets transmitted.
Multicast Packets Transmitted number of multicast
packets transmitted.
Transmitted Packets Dropped number of received
packets that were discarded during transmission.
Error Packets Transmitted number of packets dropped
due to transmission errors.
Example:
Console> show portstatistics 1
Port: 1
Octets Received: 294583 Octets Transmitted: 59309
81
show pvid
Description: Show the port VLAN identifier for each port and indicate
which port is the access port and which one is the trunk
port.
Note: If the operational PVID value differs from the administrative value, the operational value will be shown in
parentheses (). The administrative and operational
values could differ because the setting was changed
but it has not taken effect yet.
Syntax:
show pvid
Example:
Console> show pvid
Port 1 VID. . . . . . . . . . . . . . . : 1 (Access)
Port 2 VID. . . . . . . . . . . . . . . : 1 (Trunk)
Console>
show radius
Port
-------------------1812
Status
-------------------Primary
Authentication Status
-----------------------------------------------------------------------
CLI Commands
82
Console Disabled
Telnet Disabled
RADIUS Retransmissions:
RADIUS Timeout:
Console>
show ratelimit
2
5
show
rmonportstatistics
1000 Mbps)
1000 Mbps)
1000 Mbps)
1000 Mbps)
Description: Show the RMON Group 1 statistics for the selected port(s).
Syntax:
show rmonportstatistics <port number | all>
Parameters: port number the actual port number.
all specifies all ports.
Display
Parameters: Octets Received number of octets received.
Packets Rcvd number of packets received.
Broadcast Packets Rcvd number of broadcast packets
received.
Multicast Packets Rcvd number of multicast packets
received.
CRC Alignment Errors number of CRC alignment errors
due to received traffic.
Fragments Rcvd number of fragments received.
Undersize Packets Rcvd number of under-sized packets
received.
Oversize Packets Rcvd number of over-sized packets
received.
Jabbers Rcvd number of jabbers identified from
received traffic.
Collisions number of collisions encountered during transmission.
Size 64 Packets number of packets (64 octets in length)
received.
Size 65 - 127 Packets number of packets (65 to 127
octets in length) received.
Size 128 - 255 Packets number of packets (128 to 255
octets in length) received.
83
show scheduling
show scheduling
Parameters: None
Example:
show sensors
Description: Show all sensor readings for the main circuit board
(module) and each fiber port, and indicate whether the
reading is within range for proper operation. Also indicate
the highest and lowest values at which the component can
operate properly (warning thresholds).
Syntax:
show sensors
Display
Parameters: Temperature indicates the current, minimum, and
maximum temperature reading (in degrees Celsius
and Fahrenheit) of the device or port.
1.2 Volt indicates the current, minimum, and maximum
voltage reading (in millivolts) of the devices 1.2-volt
supply.
2.5 Volt indicates the current, minimum, and maximum
voltage reading (in millivolts) of the R861s 2.5-volt
supply.
3.3 Volt indicates the current, minimum, and maximum
voltage reading (in millivolts) of the R861s 3.3-volt
supply.
5.0 Volt indicates the current, minimum, and maximum
CLI Commands
84
show
snmpcommunity
Min: -45
Min: -49
Min: -9
Min: -20
Max: 105
Max: 221
Max: 0
Max: 0
(IN RANGE)
(IN RANGE)
(IN RANGE)
**OUT OF
show snmpuser
Min: 20
Max: 70 (IN RANGE)
Min: 68
Max: 157 (IN RANGE)
Min: 1140 Max: 1260 (IN RANGE)
Min: 2375 Max: 2612 (IN RANGE)
Min: 3135 Max: 3448 (IN RANGE)
Min: 4750 Max: 5250 (IN RANGE)
Auth Protocol
Priv Protocol
Group
85
-------------v3user
----------------MD5
----------------DES
-------rw
Console>
show
snmpv1v2
show switch
: Transparent
: Disabled
: Disabled
: 1 / 0 (Access)
: 1 / 0 (Trunk)
Console>
show
systeminfo
CLI Commands
86
show
trapcontrol
Description: Show trap handling for the configured traps on a per-destination basis.
Syntax:
Show trapcontrol <trap index | all>
Parameters: trap index trap number.
all identifies all configured traps.
Display
Parameters: Host identifies the trap destination IP address.
state identifies the operational state (disabled or
enabled) for the specified trap.
Example:
show
trapdestinations
192.168.3.103
Enabled
Community
-------------public
public
public
public
Username
-------------v3admin
v3guest
87
show
usernames
Description: Show all configured login usernames and their corresponding access levels.
Syntax:
show usernames
Example:
Console> show usernames
Username
Access level
-------------------------root
root
admin
admin
user
user
Console>
show uservlan
Description: Show one or all user VLAN IDs and the port(s) associated
with each VLAN.
Syntax:
show uservlan <vlan id | all>
Parameters: vlan id a value in the range 1 to 4094.
all show all user VLAN IDs.
Display
Parameters: Member Ports identifies the port(s) on which the user
VLAN is assigned. A u indicates the port is
untagged.
Example:
show weightsprofile
1u 2
CLI Commands
88
89
LED Indicators
The Metrobility services line cards provides several LEDs on the front
panel for the visible verification of unit status and proper functionality.
These LEDs can help with troubleshooting and overall network diagnosis
and management. There are separate receive (RX) and link (LK)
indicators for each port. The following table describes the meaning of
each LED when lit.
LED
Label
LED
Name
MAN
Color (Status)
Indication
FD
Full
Duplex
Green (steady)
OFF
PWR
Power
Green (steady)
ACK
Activity
Green (blinking)
LK
Link
Green (steady)
SPD
Speed
Green (steady)
ON = 100M/
OFF
OFF = 1000M/
LB
Loopback Orange
DIS
Disable
Orange
User Guide
90
R861 Services
Line Card
Switch/Hub
w/SNMP
Customer
Site
LLR2 is ON
Fiber
Cable
LED lit = established link
If one of the fiber cables is bad (as shown in the diagram box below), the
R861 will return a no link condition to its link partner. This helps the
network administrator in determining the source of the loss.
PC
Switch/Hub
w/SNMP
R861 Services
Line Card
Customer
Site
LLR2 is ON
Broken
Fiber
Conductor
Link Loss Returned
91
If LLR is disabled and the ports receiver loses link, the ports transmitter
behavior will depend on the auto-negotiation setting. If auto-negotiation is
enabled, the transmitter will shut down. If auto-negotiation is disabled,
the transmitter will continue to stay up. The following table describes the
transmitters response when the port stops detecting link, based on the
LLR and auto-negotiation settings.
Table 1: Transmitter Behavior When Port Loses Link
LLR
Auto-Negotiation
Fiber Transmitter
Disabled
Enabled
Off
Disabled
Disabled
On
PC
Switch/Hub
w/SNMP
R861 Services
Line Card
Customer
Site
PC
Switch/Hub
w/SNMP
R861 Services
Line Card
LLR2 is OFF
AN is ON
Broken
Fiber
Conductor
Customer
Site
LLR2 is OFF
AN is OFF
Broken
Fiber
Conductor
User Guide
92
R861 Services
Line Card
Switch/Hub
w/SNMP
Customer
Site
LLCF1
is ON
Fiber
Cable
LED lit = established link
If the remote cable breaks or fails, the R861 carries that link loss forward
to the switch/hub which generates a trap to the management station. The
administrator can then determine the source of the problem.
PC
R861 Services
Line Card
Switch/Hub
w/SNMP
Customer
Site
LLCF1
is ON
Fiber
Cable
Broken
Remote
Cable
93
Traps
By default, all traps for the R861 are enabled. Through software, each
trap can be disabled/enabled individually for each trap destination. The
R861 supports up to four trap destinations. The following table describes
the events that trigger SNMP trap messages to be sent to each trap
destination that is configured to receive them.
Table 2: Traps Table
Trap Index
Trap Trigger
10
11
12
13
14
15
16
Port receives notification that Far End Fault has been reset.
17
Power level in the peer device falls below its minimum operating
value.
a.The R861 includes sensors that measure the circuit board temperature, SFP transceiver
temperature, SFP transmit and receive laser levels, and circuit board power supply voltages.
b.The hysteresis value is an additional value added or subtracted from the limits or thresholds when traversing back and forth over the limit or threshold. This is intended to reduce
the number of false warnings and to avoid the flooding of the warning messages.
Lower Threshold
+ Hysteresis
Lower
Lower
Limit Threshold
Upper Limit
Hysteresis
Upper Threshold
Hysteresis
Upper
Upper
Threshold Limit
User Guide
94
J1
JP1
DIP
switches
Port 2
Port 1
JP5 or JP200
Reset
Mode
JP5 or JP200
3. Install the card into the chassis. The board will automatically reset
itself back to its original default settings. When the process is
complete, the DIS and LBK LEDs on the front panel will blink.
4. Remove the card from the chassis.
5. Remove the connector from the two pins and place it onto one pin.
The R861 is now ready for normal use.
Reset
Mode
JP5 or JP200
Normal
Operation
JP5 or JP200
95
1000BASE
100 BASE
RX
RX
1
LB
SD
DIS
RX
2
LB
TX
BP
DIS
LK
SW
AT
M
A
I
N
LK R
X
LK
P
R
I
AT
AT
RESET
SECONDARY
LBK
TX
RX
LK
R
X
T
X
MULTIRATE 10/100/1000
PWR
RESET
PWR
TX
BP
RX
RX
LK
MULTIRATE
PWR
MAIN
SD
TX
1000 BASE
redundant twister
MAN PWR
PWR
PWR
SD
LK
AT
RX
TX
FD
1
LB
LB
PRIMARY
T
X
LB
LK
RX
1
TX
MAN PWR
SD
ACT
S
E
C
SW
BP
LK
AT
CON
SD
SEC
2
TX
SD
SPD
RX
RX
LK
AT
BP
LB
BP
2
TX
LK
LB
BP
ACT
TX RX
CIRCUIT
BOARD
RELEASE
MEHCANISM
BWDM SFP
3. Align the new SFP module so the receiver (s) is positioned above the
transmitter (t). For a BWDM SFP, align it so the visible part of the
circuit board located at the back of the module is to the right.
4. Keeping the release mechanism closed (bail latch should be locked in
placed), slide the new SFP module into the slot, pushing it firmly in
place.
5. Remove the protective covering on the connector.
6. Reconnect the network cables. Verify proper segment connectivity via
the green LK LED, which should be lit.
User Guide
96
Topology Solutions
Standards-Based Multi-Service Delivery
The R861 services line cards support the delivery of point-to-point E-Line
and multi-point E-LAN services as defined by the Metro Ethernet Forum.
Traffic belonging to each service is classified by, and tunneled over,
predetermined VLANs for segregation and transport across carrier
networks. Controlled at the service line card, VLANs identify and
segregate the specific ISP-access or corporate-access E-Line service,
and determine corresponding prioritization and traffic management
parameters for the associated traffic. Management traffic, either tagged
or untagged, is given higher priority than user data traffic.
DHCP
Server
Management
Station
Central Office
1
MAN
LK
LK
RX
RX
SPD
DIS
LBK
FD PWR
10/100/1000
RX
TX
1000 Mbps
Customer Premise
Path fault management using secure ping and SNMP
97
Management
Station
NetBeacon
Element
Manager
10/100
PWR
LK
100
FD
RX
x
II
TX
100
10/100
10/100
TX
TX
LK
FD
10/100
PWR
1
LK
LK
100
100
FD
TX
TX
LBK
TX
x
II
TX
TX
100
LK
FD
RX
RX
RX
RX
LK
LK
RX
M
M
LK
RX
M
M
LK
M
M
RX
RX
LK
LK
LK
LK
x
II
TX
x
II
TX
TX
AT
TX
PWR
RX
M
M
LK
RX
M
M
LK
M
M
RX
RX
LK
LK
RX
M
M
LK
RX
M
M
TX
TX
LK
TX
FX
FX
FX
LK
TX
TX
SM
FX
TX
FX
C
O
N
S
O
L
E
A
B
R
ER
RX
RX
SPD
LK
LK
DIS
LBK
MAN FD PWR
FX
TX
TX
BWDM
FX
1000 BASE
FX
MM
LK
TX
FX
FD
RX
RX
M
M
LK
C
O
N
S
O
L
E
TX
TX
100
DIS
AT
AT
T
X
LK
LK
x
II
MGT-10
PWR
FD
T
X
T
X
LK
LK
x
II
100
RX
RX
T
X
LK
FD
FD
RX
T
X
M
M
SPD
x
II
10/100
PWR
PWR
PWR
100
RX
RX
T
X
LK
10/100
10/100
10/100
10/100
PWR
FL
RX
AT
2
TX
AT
TX
FD
MAN
FD
LK
x
II
LK
T
X
100
10/100/1000
10/100
PWR
RX
T
X
LK
TX
100
LK
RX
x
II
x
II
RX
T
X
PWR
PWR
FD
T
X
LK
x
II
10/100 BASE
PWR
RX
T
X
LK
x
II
100
FD
RX
T
X
LK
LK
TX
PWR
100 FD
FD
T
X
M
M
TX
10/100
PWR
FD
RX
RX
x
II
100
FL
FD
T
X
x
II
10/100
10/100
PWR
100
Central O ce
Customer Premise
1000 Mbps
DHCP
Server
Management
Station
802.3ah-Compatible
Switch
Central Office
1
MAN
LK
LK
RX
RX
SPD
DIS
LBK
FD PWR
10/100/1000
RX
TX
1000 Mbps
Customer Premise
Link fault management using 802.3ah
User Guide
98
RADIUS Reset
If RADIUS authentication is enabled and the RADIUS server information
is entered incorrectly, a user will not be able to log in due to the bad
configuration. To work around this condition, use the R502 proxy to reset
to defaults or use the RCLI on the R502 console.
This will reset the services line card back to its factory default settings. All
RADIUS information will be cleared, and the user can log in and re-enter
the correct RADIUS server settings.
99
Technical Specifications
Data Rate
Data Rate _______________________ 10/100/1000Mbps (copper port)
____________________________________ 100/1000Mbps (fiber port)
Power
Input
(R861-1S) ______________________________ 5 V DC @1.0 A, 5.0 W
Environmental
Operating Temperature_____________________ 0 to 50 C (R861-1S)
Storage Temperature _____________________________ -25 to 70 C
Operating Humidity ___________________ 5% to 95% non-condensing
Weight_______________________________________ 3.2 oz (0.09 kg)
Network Connections
Twisted-Pair Interface
Connector ___________________________ Shielded RJ-45, 8-pin jack
Impedance _________________________________ 100 ohms nominal
Supported Link Length _________________________________ 100 m
Signal Level Output (peak differential) _________ 2.2 to 2.8 V (10 Mbps)
______ 0.95 to 1.05 V (100 Mbps)
Signal Level Input (minimum) ___________________ 585 mV (10 Mbps)
__________________ 200 mV (100 Mbps)
Cable Type __________________________ CAT 3, 4, 5 UTP (10 Mbps)
_____________________________ CAT 5 UTP (100 Mbps)
___________________ CAT 5 or 5E UTP/STP (1000 Mbps)
(For NEBS Level III and EN55024:1998 compliance, use only
CAT 5E STP cables.)
User Guide
100
Auto-Negotiation
ARP
ASCII
AT
Address Translation
BPDU
BWDM
CLI
CPE
CPU
CWDM
dB
Decibel
dBm
DHCP
DIS
DUP
Duplex
E-LAN
E-Line
Ethernet Line
FD
Full Duplex
FEF
FPGA
GARP
GbE
Gigabit Ethernet
GMRP
GVRP
ICMP
IEEE
101
IP
Internet Protocol
ISP
km
Kilometer
L2
Layer 2
L2CP
LACP
LBK
Loopback
LK
Link
LLCF
LLR
LLR
MAC
MAN
Managed
Mbps
MDI
MIB
MM
Multimode
ms
Millisecond
MSTP
mV
Millivolt
NID
nm
Nanometer
OAM
Operating System
OUI
P-bit
Priority bit
PDU
User Guide
102
PVID
PWR
Power
QoL
Quality of Line
RFC
RMON
Remote Monitoring
RSTP
RX
Receive
SFP
SM
Singlemode
SNMP
SPD
Speed
STP
TCP
TFTP
TLV
TX
Transmit
UDP
UTP
VID
VLAN identifier
VLAN
zeroconf
zero configuration
103
UL
CSA
CE
CB
NEBS Level III
EN60950 (safety)
FCC Part 15, Class B
ICES-003 Class B (emissions)
EN55022 Class B (emissions)
EN55024: 1998 (immunity)
IEC 825-1 Classification (eye safety)
Class 1 Laser Product (eye safety)
This product shall be handled, stored and disposed of in accordance with
all governing and applicable safety and environmental regulatory agency
requirements.
The following FCC and Industry Canada compliance information is applicable to North American customers only.
USA FCC Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
User Guide
104
105
User Guide
106
Telco's liability under this warranty is limited to, the obligation, at Telco
Systems sole option, to repair or, to replace at Telco Systems plant at
Massachusetts, any part found to be defective under normal use and
service within the warranty period specified herein, provided:
a) Telco Systems is promptly notified in writing upon discovery of such
defects;
b) The defective parts are returned to Telco Systems, transportation
charges prepaid in accordance with Telco Systems instructions;
c) Telco Systems examination shall disclose to its satisfaction that such
defects have not been caused by misuse, abuse, neglect, accident, or
adjustments other than those specified in the Telco Systems Operating
and Maintenance Manual. Telco Systems shall have no responsibility
under this warranty for defects, which have been caused by misuse,
abuse, improper application, repair, alteration, accident or negligence in
use, storage, transportation or handling. Further, the original identification
markings must not have been removed, defaced or altered.
d) Equipment has been installed and operated, and maintained, in
complete accordance with the Telco Systems Operating and Maintenance Manual, and good engineering practice.
107
User Guide
108
The foregoing warranties are in lieu of any and all other warranties,
expressed or implied, including, but not limited to, warranties of
merchantability, fitness for a particular purpose or against infringement of
any rights of third parties. Telco Systems liability on any claim for money
damages (including, without limitation negligence for any loss or damage
arising out of, connected with, or resulting from the sale of products
hereunder, or from the performance or breach thereof, or from the
design, manufacture, sale, delivery, resale, installation, inspection, repair,
operation or use of any merchandise manufactured by Telco Systems)
shall in no case exceed the price allocable to the merchandise or part
thereof which gave rise to the claim. Purchaser will hold Telco Systemsharmless with respect to any claims or actions by third parties. In
particular, Telco Systems expressly disclaims and shall in no event be
liable for any indirect, special, incidental or consequential damages.
109
Console changes
are only allowed
through the
console port.
This message appears if you try to use the set console command
through a telnet session.
Error:
Administrative
string does not
match.
The SNMP administrative community string is missing or entered incorrectly. The default string is admin.
Error: Auto
Negotiation not
supported on Port
2.
Error: Cannot
remove root.
The fiber port speed is set at 1000 Mbps by default. The fiber port can
also be set to 100 Mbps via software or dip switch, but can not be set to
10 Mbps. Only the copper port can be configured to 10 or 100 Mbps.
Error: Community
name cannot be
longer than 49
characters.
The SNMP community string must not contain more than 49 characters.
Error: Community
name must be
have an end quote.
The fiber port (Port 2) is set to full duplex and the mode cannot be
changed.
Error Messages
110
Error: Invalid
gateway IP format.
Error: Invalid IP
address format.
The network mask is not in the standard dotted decimal notation (e.g.,
255.255.255.0).
Error: Invalid
parameter ( xxxx ).
The parameter, xxxx, is not an acceptable option for the command. Make
sure the parameter is spelled correctly. If the parameter is a number,
make sure it is within the range of acceptable values.
Error: Invalid
speed setting on
Port x .
The OAM control mode was set incorrectly. The only acceptable options
are active or passive.
Error: IP address
entry not found.
The IP address specified was not identified. Make sure you typed the IP
address correctly.
Error: Maximum
number of user
VLANs already
configured.
Error: Missing
filename value.
Error: Missing
group parameter.
Error: Missing
image number
parameter.
Error: Missing
image parameter.
The FPGA image number is required with the command, but it is missing.
Error: Missing IP
parameter.
111
Error: Missing
MAC address
value.
The MAC address is a required field with the command, but it is missing.
The trap index number is a required field with the command, but it is
missing.
Error: Missing
username
parameter.
Error: No such
username.
The username does not exist. Make sure the spelling is correct.
Error: Passwords
do not match.
Error: RADIUS
server not found.
The RADIUS server you want to clear is not in the list of configured
RADIUS servers. Make sure the IP address of the RADIUS server is
entered correctly.
The specified value for the management VLAN is invalid because the
number has already been assigned as a user VLAN. The two VLANs
must be different.
Error: Trap
destination table is
full.
Up to four trap destinations can be configured. To add a new trap destination, you must first delete one of the current entries from the table.
When configuring user VLANs, only the access port can be untagged.
Untagging is not allowed on the trunk port.
Error Messages
112
Error: Unknown IP
address.
The IP address specified for setting a trap control must be one that is in
the trap destination table. Use the show trapdestinations command to
see what IP addresses are available.
Error: Username
cannot be longer
than 31 characters.
Error: Username
must be have an
end quote.
Error: Username
must be specified
for SNMPv3 traps.
A value other than 1 or 2 was entered for the FPGA image number.
The specified number of bytes the device should send when pinging a
network host is not in the acceptable range of 56 to 1472 bytes.
113
An unacceptable value was entered for the user VLAN. A valid value is
any number between 1 and 4094. The number must also be different
from any management VLAN ID values.
Error: Valid
window values are
between 10 and
600.
Error: Valid
window values are
between 100 and
9000.
Error: Valid
window values are
between 148809
and 89285714.
Error: Valid
window values are
between
125000000 and
3205032704.
Error Messages
114
Error: VLAN #
already assigned
to PVID or
Management
VLAN.
The specified value for the user VLAN is invalid because it has already
been assigned as either a PVID or a management VLAN. The user
VLANs must be unique.
The specified VLAN ID for the command is invalid. Make sure it is typed
correctly. If available, use the all option. For example, enter show
uservlan all to see all configured user VLANs.
To run a configuration file, you must first download a valid file into one of
the two image locations.
Invalid retransmit
count entered,
valid range (1-10).
Invalid timeout
value entered,
valid range (1-10).
The value entered for the RADIUS timeout is out of range. The time must
be in the range 1-10.
Login failed.
The login username or password is incorrect. Make sure the [CAPS LOCK]
key is not pressed.
Maximum config
file size exceeded.
The configuration file you attempted to download was more than 8K,
which is the maximum size supported by the R861.
Maximum number
of server entries
exceeded.
Up to five (5) RADIUS servers can be configured for the device. To add
another RADIUS server, you must first delete an existing server using the
clear radiusserver command.
Start Loopback
Request denied,
port must be fiber.
115
Telnet user
attempted to add/
change a RADIUS
server.
Telnet user
attempted to
change RADIUS
authentication.
Telnet user
attempted to clear
a RADIUS server.
The user VLAN ID you specified has not been configured. Make sure the
VLAN ID was typed correctly. Use the show uservlan all command to
view all available values.
VLAN # is already
assigned to a User
VLAN.
The VLAN ID you tried to assign to the port VLAN (pvid) has already
been applied to a user VLAN. The VLANs must be different.
You attempted to enable Far End Fault on Port 1. FEF can only be set on
the fiber port, Port 2. FEF is always disabled on Port 1.
You attempted to enable Link Loss Return on Port 1. LLR can only be set
on the fiber port, Port 2. LLR is always disabled on Port 1.
Error Messages
US Headquarters
15 Berkshire Road Mansfield MA USA 02048
tel: 1.781.551.0300 fax: 1.781.225.2344
www.telco.com
5660-000106 Rev D
February 2010