Sunteți pe pagina 1din 4

Air Conditioning

AIR CONDUCTING FAN


PRODUCT FLYER

Air Conducting Fan


AH SERIES

Air Conducting Fans are supporting equipment for ventilators and air conditioners to
move exhaust gas in car parks and help to improve the efficiency of ventilation or air
conditioning in factories and warehouses.

Installation Examples for Large Spaces

Car Parks: Removing exhaust gas


Air Conducting Fans are particularly useful for moving and
expelling stagnant, dirty exhaust gas and hot air that stagnates in
the midsections of buildings with complicated floor plans.

Warehouses and Factories: Circulating cool air


Air Conducting Fans help circulate air conditioned air; they improve
the working environments by reducing temperature variations
throughout large indoor spaces. They enhance the effectiveness of
cooling over a wider area, and the airflow they generate creates a
refreshing breeze.

Easy Installation

Low Power Consumption

Quiet and Compact

The Air Conducting Fan can be easily


installed by simply mounting it to
suspension bolts on the ceiling. The angle
of the air vent is adjustable to six levels.

With the compact and high-efficiency


motor, and also the axial fan, Air
Conducting Fan saves lots of energy.

The compact axial fan (quiet propeller


design) reduces noise level yet still makes
it possible to achieve substantial airflow.
The slim and lightweight design offers
greater flexibility in your installation plans.

Air Conducting Fans not in use

Temperature Distribution
Using Air Conducting Fans help the
air conditioned
100ppm
air to reach all corners, improving comfort levels.

High

Air Conducting Fans in use

0ppm

Low

*Thermal distribution graphic for reference only. Actual results may differ.

CO Distribution

100ppm

The airflow created by Air Conducting Fans allow


fresh air to permeate all corners of a car park,
while at the same time reliably directing the vehicle
exhaust gas toward the exhaust fans.

Air Conducting Fans not in use

Air Conducting Fans in use

Air Velocity Distribution


AH-1006S-E

AH-1509S-E

10

Distance from air outlet (m)

5
4
3
2
1
0
15

Side view

1m/s
0

0.5m/s

0.3m/s
5

Distance from air outlet (m)

5
4
3
2
1
0
10

10

Distance from air outlet (m)

Side view
1m/s

5
4
3
0.3m/s
2
1
0
15

0.5m/s

10

Distance from air outlet (m)

AH-2009S-E

Distance from air outlet (m)

3
2
1
0
1m/s
0.5m/s 0.3m/s
1
2
3
5
10
15

1m/s

Distance from air outlet (m)

Side view

Plan view

5
4
3
1m/s
0.5m/s 0.3m/s
2
1
0
5
10
15

Distance from air outlet (m)

20

3
2
1
0
1
2
3
30

Distance from center (m)

5
4
3
1m/s 0.5m/s
0.3m/s
2
1
0
10
15
20

Distance from air outlet (m)

20

6
5
4
3
2
1
0
30

0.5m/s

10

0.3m/s

Distance from air outlet (m)

Side view

1m/s

10

Low speed

Distance from floor surface (m)

Side view

Plan view

Distance from center (m)

Distance from air outlet (m)

Distance from air outlet (m)

Side view

High speed

Distance from floor surface (m)

3
2
1
0
1m/s 0.5m/s
0.3m/s
1
2
3
10
15
20

Distance from center (m)

Plan view

5
4
3
2
1m/s 0.5m/s 0.3m/s
1
0
5
10

1m/s
0

AH-3009S-E
Low speed

Distance from floor surface (m)

High speed

Distance from center (m)

0.5m/s 0.3m/s

3
2
1
0
1
0.5m/s 0.3m/s
2
3
5
10

Distance from floor surface (m)

1m/s

Distance from air outlet (m)

0.5m/s

Plan view

0.5m/s

0.3m/s

Distance from air outlet (m)

Plan view

1m/s

0.5m/s 0.3m/s

10

20

Distance from air outlet (m)

Side view

1m/s 0.5m/s 0.3m/s

10

20

Distance from air outlet (m)

3
2
1
0
1
2
3
30

6
5
4
3
2
1
0
30

Distance from center (m)

Side view

1m/s

3
2
1
0
0.3m/s
1
2
3
15

Distance from floor surface (m)

Distance from air outlet (m)

Plan view

Distance from center (m)

10

0.3m/s

0.5m/s

Low speed

Distance from floor surface (m)

1m/s

3
2
1
0
1
2
3
10

Distance from center (m)

Plan view

High speed

Distance from floor surface (m)

1m/s 0.5m/s 0.3m/s

3
2
1
0
1
2
3
15

Distance from center (m)

Plan view

Low speed

Distance from floor surface (m)

High speed

Unit (mm)

0ppm

Specifications
Single-phase, 50Hz 220-240V
Model

Fan Speed

AH-1006S-E
AH-1509S-E
AH-2009S-E
AH-3009S-E

Starting
Current (A)

Weight (kg)

Dimensions
(HxWxD)
mm

0.23

190x600x197

0.43

10.5

190x900x197

0.85

11

190x900x197

20.5

210x910x220

Air Volume
(m/h)

Running
Current (A)

Input Power
(W)

Air Velocity
Max. (m/sec)

Noise (dB)

High

700-750

0.14-0.15

30-34

6.5-6.9

42-44

Low

570-620

0.13-0.13

28-32

5.3-5.7

39-40

High

1180-1270

0.26-0.26

55-62

7.3-7.8

43.5-45

Low

940-1040

0.24-0.25

51.5-59

5.8-6.4

39-41.5

High

1350-1400

0.43-0.47

90-105

8.3-8.6

46.5-47.5

Low

1130-1200

0.36-0.37

77-87

7.0-7.4

44-46

High

2100

0.87-0.94

191-223

8.2

58-58

2.53

Low

1860

0.74-0.75

150-165

7.3

55.5-56

1.55

AH-1006/1509/2009S-E

AH-3009S-E
* The mounting angle of the unit body can be adjusted in 8 steps.
(0, 11.3, 22.5, 33.8, 45, 56.3, 67.5, 90)
Power cable
Effective length1m

* The mounting angle of the unit body can be adjusted in 8 steps.


(0, 11.3, 22.5, 33.8, 45, 56.3, 67.5, 90)
716(1016)
External attachment pitch
680(980)
Internal attachment pitch

100
210

12

Attachment details
58

489(789)

210
292

297

Air flow

4-12x40
mounting hole
130

80
80

910

130

220

223

190

256
153
197

390

Air flow

152
74

137
100

525(825)

600(900)
716
794

Terminal box

1032
1110

*Figures in parentheses is the value of the AH-1509S-E and AH-2009S-E.

Unit (mm)

MitsubishiElectric.com.au

Printed May 2016


The specifications and information in this flyer are subject to change without notice. Colours depicted in this flyer may vary slightly. Images are for illustrational purposes only.