Welcome
Welcome to use Capacitance, Inductance Measuring module.
The modular is produced by ICStation in 2014.
Product Features
ICSH014A is a Capacitance, Inductance Measuring module.
Engaged in the development of electronic engineers often need to measure inductance
and capacitance, and inductance capacitance meter sold on the market price is higher,
and the measurement of small capacitance inductance and small error, this instrument
based on LC resonant principle, join the accurate measurement of high-speed micro
controller calculation, small capacitance can be measured the inductance 1uH and less
than 1pF, the maximum this is also the characteristics of the instrument, particularly
suitable for microwave production and switching power supply transformer, inductance
measurement.
ICSH014A (LC module) with four measuring mode:
1.C mode...... Capacitance (0.01pF-10uF).
2.L mode...... Inductance (0.001uH-100mH).
3.HL mode...... Large inductance (0.001mH-100H)
4.HC mode...... Large capacitance (1uF-100mF)
All stalls are automatic range, the use is very convenient. In this way, ICSH014A
Whether from the measurement range and measurement precision can completely
replace any kind of inductance and capacitance measuring instrument on the market,
the performance parameters to the digital bridge, is a highly cost-effective instrument.
Introduction of structure
The overall effect diagram . When in use, you can use the Micro USB connection line is
connected to the computer USB testing instrument power supply, if the user has a
mobile phone charger with USB or with 5V power adapter with DC plug can also be
directly to the instrument power supply. Special note: if you are using DC plug adapter,
polar please hole positive confirmation, peripheral negative, while the Micro USB
interface does not occur polarity error conditions.
The structure of the instrument:
The button has a total of 5, "Reset" to 0 "HC" button, large capacitance, inductance,
select "HL" option, "L/C" and black expansion function button. The HC, HL and L/C
selection is self lock , a press release was 1, 0, and X represents the arbitrary function,
see the table below:
black.
2. If the measurements before the display is 0, sometimes also need to zero
adjustment, this might be the deviation is negative, but the display will not show
negative.
3. Is strictly prohibited in the test terminal element when pressed zeroing button, this
operation will lead to the erroneous results.
4. Is strictly prohibited without testing capacitor discharge, otherwise there may result in
damage to the meter.
5. To use the 5V adapter module power supply, ensure that the polarity is negative "",
otherwise it will damage the module.