Sunteți pe pagina 1din 1

Data sheet

Equalizer Vessel
Project:
Project-Nr.:

General Data
Operating Conditions
Design

Rev.
QUAT_N_PR_XXXXX_PID100_000B_SHEET03

0 Local Storage require.:

QUAT
Nitrilation
Buffer Vessel
Water/Glycol
liquid
T: 0C -50C; H: 65-72%;
wind velocity: 11m/s

0
2
0
0
0
0
0

Operating temperature:
Operating pressure
Vapor pressure:
Density at op. temperature:
Viscosity at op. temperature:
Max. viscosity:
Specific heat capacity:

0
0
0
0

Design Temp. (MAWT)


Design Pressure (MAWP)
corrosion allowance
Joint Efficiency

C
bar(g)
mm
%

200
FV/10
1
85

0
0
0
0
0
0

Heating device:
Design Temp. (MAWT)
Design Pressure (MAWP)
Heating medium:
Cooling medium:
Insulation (by client on site)

m
mm

C
bar(g)

permanent
-

100 mm Foamglas

0 Material shell:
0 Material heating device:
2 Material support:

1
800 x 2400

P265GH
CS-Legs

Shell with torispherical heads

Input
Output
Drain
Level control +
Level control Nitrogen Application
Safety valve
Filling line
Continues level
Pressure Control
Hand hole
Legs

N01
N02
N03
N04
N05
N06
N07
N08
N09
N10
H01
T01-03

PN

Type

50
50
50
25
25
15
50
50
80
25
250
-

16
16
16
16
16
16
16
16
16
16
16
-

WNF DIN EN 1092-1


WNF DIN EN 1092-1
WNF DIN EN 1092-1
WNF DIN EN 1092-1
WNF DIN EN 1092-1
WNF DIN EN 1092-1
WNF DIN EN 1092-1
WNF DIN EN 1092-1
WNF DIN EN 1092-1
WNF DIN EN 1092-1
WNF DIN EN 1092-1
-

Misc.

1
1
1
1
1
1
1
1
1
1
1
3

DN

Revision

Construction

on site
vertical
AD 2000, EN 1591
-

%
kg/m
mm
h
C
bar(g)

0 Flange proof acc. AD 2000/B7-B8 and DIN EN 1591


0 Nozzle Loads: Fxyz= 75 DN [N]; Mxyz=0,16 DN [Nm]
0 inclusive Lifting-Device and clips for insulation and pipes
3
2
1
0
Nr.

Weather protection:
Orientation:
Design-Code:
Important equipment:

Solid fraction:
Density solids:
Particle size:
Op. hours per year:
Op. temperature top heat.:
Op.pressure top heat.:

Name Nr.

Gansler
Gansler
Gansler
created

0
0
0
0

0
0
0
0
0
0

Connections

09.03.16
12.01.16
12.11.15
date

hold
hold
1

120
3,0
<0,05
1049
0,8
1
3,7

cylindric

Volume:
Dimensions ID x IH:
Coating:
Features:

0 Manufacturer:
0 Model:
0 Quantity:

C
bar(g)
bar(a)
kg/m
mPas
mPas
kJ/kg*K

0 Vessel Form:

0
0
0
0
0
0
0
1
1
0
1
2

N-V-006

150 062 10 000 19

PID-Nr.:
Plant:
Unit:
Description:
Service:
Medium:
Properties:
Ambient conditions:

0
2
0
0

N-V-006
1 of 1

QUAT

Rev.

0
0
0
0
0
0
0
0

Doc.:
Sheet:

date

reviewed

date

Flange Face
B1-RFS
B1-RFS
B1-RFS
B1-RFS
B1-RFS
B1-RFS
B1-RFS
B1-RFS
B1-RFS
B1-RFS
B1-RFS
-

Position

Comment

top head
bottom head
bottom head
shell
shell
top head
top head
shell
top head
shell
shell
bottom head

U-beams

approved Cause of Issuance/Review

S-ar putea să vă placă și