A New Large Pump for Oil Sands

Michael Bootle
Principle Engineer Weir Minerals

Calgary Pump Symposium 2015

Presenters

Michael Bootle

1984-1987: Application Engineer and Regional Sales


Manager for Lawrence Pumps Inc.
1987-1990: Carpenter
1990-2000: Field Service and Senior Field Service Engineer
for Warman International
2000- 2014: Senior Design Engineer for Weir Minerals North
America
2014: Principal Engineer for WMNA

Calgary Pump Symposium 2015

Why the Need? HI Slurry Classification


Based on
Specific Gravity
& d50 Particle
Size
Typical Oil Sands
Hydrotransport and
Tailings Slurries:
100 400 micron
1.4 1.6 sg

Calgary Pump Symposium 2015

Why the Need?


HI Head Recommendations
Based on Slurry
Classification:

Class 1:
Class 2:
Class 3:
Class 4:

105 m
73 m
55 m
40 m

Wear history has


shown these
recommendations
are not
conservative

Calgary Pump Symposium 2015

Variety of Pump Types


for Different Applications
N s and ns =

Ns =

ns =

N Q

3/4

rpm USgpm

ft

3/ 4

rpm m 3 / sec
3/4

Ns (US) = ns (Metric) x 51.64

Calgary Pump Symposium 2015

Specific Speed, Efficiency and Pump Size

Calgary Pump Symposium 2015

Early Oil Sands History:


Warman 450 STL Pumps on Plant 5 PSV Uflow
(4) 450 STL

450 mm discharge
500 mm suction
950 mm impeller
41.7 ns
D2/D1 = 1.93

Installed mid 80s


Neoprene Lined
6000 - 8000 hr life in
late 80s, early 90s

Calgary Pump Symposium 2015

Early Oil Sands History:


Plant 5 Warman 450 STL Specific Speed
Horizontal Pum p

Calculation of
Specific Speed:

450 L
CURVE SHOWS APPROXIM ATE PERF ORMANCE FOR CLEAR WATER (In ternation al Test Stan dard ISO 9906:199 9 - Grad e 2 u nless other wise sp ecified). For me dia other than water ,
corr ections m ust be made for density, visc osity and/or othe r ef fects of solids. WEIR M INERALS reser ves the right to ch ange p ump perf orma nce an d/or delete im pelle rs without notice. Fram e
su ita bility must be che cked f or each d uty and drive arr angem ent. Not all fr ame alternatives are necessarily a vaila ble fr om each m anuf acturing centr e.

60

6 00 rpm

Estimated 2015 System Curve

50 % 6 0%
70%

50
8 0%

40

Hr
NP S

12m

4 00 rpm

20
8m

3 50 rpm

Max imum Flow

Gland Sealed Pump


(No rm Max r /min)
545
700

Mi n P assag e Si ze

103m m
C urve
R evision
2
R evision Notes
MI NIMUM P AS SAGE SIZ E ADDE D

R eference
MAD ISON TESTS 840303, 04, 05;
A4-0-1037; N PSH : MAD ISON
TESTS 841011, 12
Las t Iss ued
Jan 93
Is sued
Mar 06

6m
5m
4m

10

- KW )
560
560
600
900

S eal

Polymer
Metal

3m

Multiply by 51.67 to obtain Specific


Speed in terms of US gpm & feet:
41.7x 51.67 = 2155

5
950mm
Closed
Material
Metal

Liner

3 00 rpm

n s = 41.7

Impeller
Vanes
Vane
Type
P art No
STL45147DP2

80 %

30 4 50 rpm

600rpm (4640 m 3hr ) /(3600 sec/ hr )

(41 .4m)3 / 4

83%

EFF IC
IE

5 00 rpm

NCY

3/ 4

450mm
500mm

Frame ( Rat ing


ST
SX
G
GG

85 %

10m

ns =

83 %
5 50 rpm

Head, H (m)

ns =

N Q

P ump
D isc harge
Suc tion

Average Flow

Min imum Flow


2000

Calgary Pump Symposium 2015

4000
F lo w Rate, Q (m/hr)

6000

8/20 15 Weir Miner als Au str alia ( PT C)


All Rig hts Re serv ed
TYPICAL PU MP PE RFORM ANC E CUR VE

WPA450A22/2

1997 Plant 5 Process Change:


North Mine Hydrotransport Feed
Draglines, bucket
wheels, conveyors
and tumblers
changed to truck
and shovel, in pit
crushing and
hydrotransport

Calgary Pump Symposium 2015

1997 Plant 5 Process Change:


North Mine Hydrotransport Feed
Increased max solid size:
Tumblers:
9/16x 2
North Mine screens: 2 x 3

Increased flow rates & head:


Flow:

13,000 to 20,000 gpm


(3000 to 4500 m3/hr)
Head: 46 to 70 ft
(14 to 21 m)

Calgary Pump Symposium 2015

10

1997 Plant 5 Process Change:


North Mine Hydrotransport Feed
Decreased 450 STL Life:
Cutting of Neoprene liners
Increased impeller vane and
back shroud wear

Material change required to


restore adequate 450 STL life:
High chrome liners
Hyperchrome impellers

On two pumps, larger 500 STL


wet-ends installed:
Greater wear life with
standard high chrome iron

Calgary Pump Symposium 2015

11

Syncrude Aurora PSV Uflow:


Warman 650 ULP Installation
Part of Aurora SWQR:
Larger 5 x 5 Screens

(2) Warman 650 ULPs


650 mm Discharge
800 mm Intake
1455 mm Impeller
39.8 ns
D2/D1 = 1.83

Installed 2006
Calgary Pump Symposium 2015

12

Syncrude Aurora PSV Uflow:


Warman 650 ULP Operation

240-1-G1 Average:

240-2-G1 Average:

7881 m3/hr
26.3 m
1.45 sg
306 rpm
175-225 micron

7397 m3/hr
20.2 m average
1.47 sg
282 rpm
175-225 micron

Barely Class 4 Slurry:


40 m limit

Calgary Pump Symposium 2015

13

Syncrude Aurora PSV Uflow:


Warman 650 ULP Wear Life
Impeller:
2500 - 3500 hours

Throatbush (suction liner):


3100 - 3800 hours

Volute Liner:
3500 - 5500 hours

Frame Plate Liner Insert (back liner):


4000+ hours

Calgary Pump Symposium 2015

14

Syncrude Aurora PSV Uflow:


650 ULP Impeller Wear: 2500 - 3500 hrs
Mainly vane leading edge wear
Despite operation near BEP, back shroud intact

Calgary Pump Symposium 2015

15

Syncrude Aurora PSV Uflow:


650 ULP Throatbush Wear: 3100 - 3800 hrs
Relatively uniform wear pattern occasional gouging near ID
OD wear at edge of tungsten carbide cladding since
addressed with OD cladding and elastomer gasketing

Calgary Pump Symposium 2015

16

Syncrude Aurora PSV Uflow:


650 ULP Volute Wear: 3500 - 5500 hrs
Smooth wear pattern associated with BEP operation
Little wear at ID junction with side liners

Calgary Pump Symposium 2015

17

Syncrude Aurora PSV Uflow:


Desired Wear Life -2014
Syncrude Requisition MR 240-G-5000 issued
May 2014 with requirement for:
Casing/volute liner life of at least 8500 hours
Impeller and throatbush/suction liner life of at
least 4250 hours

Substantial increase in wear life will require


larger pump design to increase life

Calgary Pump Symposium 2015

18

Effect of Specific Speed on Pump Wear

With permission, from Prediction of Slurry Pump Wear and Cost


- Sellgren and Addie, WEDA XXV, New Orleans, 2005

Calgary Pump Symposium 2015

19

Effect of Suction Diameter on


Suction Liner Wear

With permission, from Prediction of Slurry Pump Wear and Cost


- Sellgren and Addie, WEDA XXV, New Orleans, 2005

Calgary Pump Symposium 2015

20

Impeller Geometry and Its Effect on


Specific Speed
Values of Specific Speed, ns, using m3/sec & m

Courtesy of Hydraulic Institute

Calgary Pump Symposium 2015

21

Syncrude Leading Edge Wear Model


Dominant mode of impeller wear is impingement
damage on the vane leading edge
Rear shroud wear at the vane leading edge can also be
significant
Vane thinning and wear at the trailing edge is minimal

Calgary Pump Symposium 2015

22

Syncrude Leading Edge Wear Model


Dan Wolfes wear model showed impeller vane wear can be dramatically
reduced by lowering leading edge peripheral and impact speed

Calgary Pump Symposium 2015

23

Syncrude Leading Edge Wear Model


Key assumption is that vane wear is related to
leading edge velocity to the 2nd or 3rd power
Benefits to lower specific speed (bigger diameter):
Increase OD/ID ratio
Decrease rotational speed, inlet peripheral speed and
impact speed for a given head
Decrease leading edge wear rate
Increase vane length
Increase impeller wear life

Calgary Pump Symposium 2015

24

Syncrude Aurora PSV Uflow:


Desired Future Operating Conditions
Max Duty:

10,500 m3/hr
45 m
1.6 sg
420 micron
400 rpm

Normal Duty:

7900 m3/hr
24 m
1.46 sg
232 micron
300 rpm

Normal Duty
comparable to
recent operation

Calgary Pump Symposium 2015

25

Syncrude Aurora PSV Underflow:


Existing Weir Pump Options
650 ULP: 57 OD
Current life
indicates 8000
hours unlikely
with this design

650 MCH, MCR, &


MCU: 69-70 OD
Lined and unlined
low pressure mill
circuit designs

600 HTP: 62 OD
Hydraulically too
small for required
volume flow at
low head

Calgary Pump Symposium 2015

26

Syncrude Aurora PSV Uflow:


Warman 650 HT Installation

Calgary Pump Symposium 2015

27

Syncrude Aurora PSV Uflow:


New 650 HT (74 Impeller) Design

Max Duty:

Normal Duty:

10,500 m3/hr
45 m
1.6 sg
420 micron
300 rpm
7900 m3/hr
24 m
1.46 sg
232 micron
225 rpm

Approximately
75 to 100 rpm
lower than
existing 650 LP

Calgary Pump Symposium 2015

28

Syncrude Aurora PSV Uflow:


650 HT Duty Summary 3500 BHP Motor

Normal duty at approximately 224 rpm and 1269 HP power draw


Max duty requires 312 rpm and 3653 HP at 1.6 sg and 420 microns
Max duty requires 306 rpm and 3125 HP at 1.46 sg and 232 microns

Project
Slurry Case
3
Flow Rate (m /hr)
Total Head per Pump (m)
Solids d50 (micron)
Occurrence Time (%)
Stream Specific Gravity (-)
Weight Percent Solids (%)
NPSHa (m)
Pump Selection
Quantity
Head Ratio (Roudnev-Wilson)
Efficiency Ratio (Roudnev-Wilson)
Required Water Head (m)
Required Speed (rpm)
Water Efficiency (%)
Expected Slurry Efficiency (%)
Expected Power Draw (kW)
Expected Power Draw (BHP)
NPSHr (m)
3
Approximate BEP Flow (m /hr)
Percent of BEP flow (%)

Normal
7900
24.0
232
average
1.46
50.60
> 15 m

0.96
0.96
25.0
224
83.0
79.7
947
1269
4.6
7800
101.3

Syncrude PSV Underflow Retrofit


Max. with 1.6 sg & 420 d50
10500
45.0
420
1.60
60.23
> 15 m
650 HTP
2
0.92
0.90
48.9
312
84.0
75.6
2725
3653
7.2
10800
97.2

Calgary Pump Symposium 2015

Max. with average sg & d50


10500
45.0
232
1.46
50.60
> 15 m

0.96
0.96
46.9
306
84.0
80.6
2331
3125
7.1
10600
99.1

29

Alternative Applications for 650 HT(P)


Prior to settling
on final design,
application
opportunities
were reviewed:
Showed need
for high
pressure and
low pressure
designs
Showed need
for high and
low flow
designs

Calgary Pump Symposium 2015

30

650 LP vs. 650 HT Wet-end Comparison


650 HT substantially larger
with respect to:

Volute area
Volute thickness
Impeller diameter
Vane length
Throatbush thickness

Lower ns:
29.4 vs. 39.8

Larger OD/ID ratio:


2.47 vs. 1.83

Expect significant increase in


wear life:

650 LP

Details to follow
650 HT

Calgary Pump Symposium 2015

31

650 LP vs. 650 HT Impeller and Volute


Comparison
IMP. EYE DIA. 760mm
IMP. O.D. 1880mm
VANE LENGTH 1726 mm
MID VANE DIA. 550mm
IMP. EYE DIA. 794mm
IMP. O.D. 1455mm
VANE LENGTH 980mm
MID VANE DIA. 573mm

Thickest in
High Wear
Areas

1.5 to 2
times 650 LP
Volute
Thickness

Constant Thickness Wall

650 LP

Calgary Pump Symposium 2015

650 HT / HTP

32

650 LP vs. 650 HT Installation:


Pump House 1
Pump House 1 with low 12.5 tonne overhead crane had
little room to move spares particularly volute liner

650 ULP

Calgary Pump Symposium 2015

650 UHT

33

650 LP vs. 650 HT Installation:


Pump House 2
Pump House 2 with high overhead crane has greater
room to move spares still 12.5 tonne crane

650 ULP

Calgary Pump Symposium 2015

650 UHT

34

Casing Types, Radial Load


& Preferred Operating Range
True/Near Volute

80 to 120% BEP

Semi Volute

60 to 110% BEP

Calgary Pump Symposium 2015

Circular/Annular Volute

40 to 100% BEP

35

650 LP Velocity Plots at 302 rpm

Calgary Pump Symposium 2015

36

650 HT Velocity Plots at 224 rpm


VAR IATION OF VELOCITY AROUND THE C ASING FOR VARIOUS FLOW R ATES

AVERAGE INTERNAL VELOC ITIES, m/sec

18

PERCENT
B.E.P.
FLOWRATE

16
14

30%
12

40%

10

50%
60%

70%

T A

2
0
A

90%
100%

C
F

80%

110%

120%

E
F

130%

CASING WALL SECTIONS

Calgary Pump Symposium 2015

37

650 LP vs. 650 HT Relative Velocity &


Velocity2 at Normal Duty
Velocity2 is a good general indicator of relative
wear for pumps of different size
650 LP vs. 650 HTP - Aurora PSC U'flow: 7900 m3/hr @ 24 m
650 ULP @ 302 rpm
650 HTP @ 224 rpm
Section
Vel (m/s)
Velocity ^ 2
Vel (m/s)
Velocity ^ 2
T
9.60
92
6.26
39
A
10.87
118
6.84
47
B
11.74
138
7.30
53
C
12.31
152
7.64
58
D
11.98
144
7.91
63
E
11.75
138
8.13
66
F
11.69
137
8.30
69
G
11.64
135
8.45
71
H
9.45
89
6.51
42

Calgary Pump Symposium 2015

38

650 LP vs. 650 HT

2
Velocity

Plots

650 LP shows characteristic peak associated with two arc volute


650 HTP has better, flatter, lower profile

Calgary Pump Symposium 2015

39

8000 Hour Volute Goal:


Predicted 650 HT Volute Wear Life
Existing 650 ULP wear life: 3500 5500 hours: Use 3500 hours
Relative velocity2 factor: (12.31 m/s/8.45 m/s)2 = 2.12
Relative thickness at predicted peak wear areas = 2.0
Predicted Life based on Geometry change alone:
3500 hours x 2.12 x 2.0 = 14,840 hours
3

650 LP vs. 650 HTP - Aurora PSC U'flow: 7900 m /hr @ 24 m


650 ULP @ 302 rpm
650 HTP @ 224 rpm
Section
Ve l (m/s)
Velocity ^ 2
Ve l (m/s)
Velocity ^ 2
T
9.60
92
6.26
39
A
10.87
118
6.84
47
B
11.74
138
7.30
53
C
12.31
152
7.64
58
D
11.98
144
7.91
63
E
11.75
138
8.13
66
F
11.69
137
8.30
69
G
11.64
135
8.45
71
H
9.45
89
6.51
42

Calgary Pump Symposium 2015

40

4000 hr Impeller Goal:


Predicted Life: Syncrude Wear Model
Pump:

650 LP

650 HT

Speed:

302 rpm

226 rpm

Inlet mid-vane diameter:

573 mm (22.56)

550 mm (21.65)

Inlet peripheral speed:

9.06 m/sec

6.45 m/sec

Outside diameter:

1455 mm (57.28)

1880 mm (74.02)

Vane length:

980 mm (38.6)

1726 mm (68)

Existing 650 LP Impeller wear life: 2500 3500 hours: Use 2500 hours
Using Dan Wolfes program and the above imputs:
Power

650 LP Baseline

650 HT Baseline

Predicted 650 HT
Life

3rd

251 hr/in

491 hr/in

9362 hr

2.5

229 hr/in

400 hr/in

8858 hr

2nd

207 hr/in

325 hr/in

7861 hr

Calgary Pump Symposium 2015

41

4000 hr Throatbush Goal:


CFD Wear Analysis

8100 m3/hr @ 24 m:
650 LP @ 294 rpm
650 HT @ 225 rpm

650 HT shows lower velocity at midpoint and seal dam:


16 m/sec vs. 18 m/sec at midpoint
11.5 m/sec vs. 14.2 m/sec at seal dam

11.5 m/s

14.2 m/s

650 LP

18 m/s

650 HT
16 m/s

Calgary Pump Symposium 2015

42

4000 hr Throatbush Goal:


CFD Wear Prediction
Existing 650 LP wear life: 3100 3800 hr:
Use 3100 hour

Wear Calculation at Eye:


Relative part thickness at eye = 1.60
Velocity2 ratio at seal dam: (14.2 m/sec/11.5 m/sec)2 = 1.52
3100 hr x 1.60 x 1.52 = 7539 hours

Wear Calculation at Mid-point:


Relative part thickness at mid-point = 2.49
Velocity2 ratio at mid-point: (18 m/sec/ 16 m/sec)2 = 1.27
3100 x 2.49 x 1.27 = 9803 hours

Calgary Pump Symposium 2015

43

4000 hr Throatbush Goal:


Rough OD/ID Ratio Prediction
650 LP OD/ID: 1.83
650 HT OD/ID: 2.47
Relative wear:
Assume similar trend:

34.3m
= 2.31
14.8m

34.3
14.8

Predicted life:
3100 hr x 2.31 x 1.6 = 10,000+ hours
Relative wear

Relative thickness

Calgary Pump Symposium 2015

1.83

2.47

*Chart used with permission, from


Prediction of Slurry Pump Wear and
Cost - Sellgren and Addie, WEDA XXV,
New Orleans, 2005

44

650 HT Adjustable Throatbush


The 650 HT features a full
face adjustable throatbush
(suction side liner)
Adjustment:
Increases head output
Increases efficiency
Reduces required speed
Reduces throatbush wear

Calgary Pump Symposium 2015

Throatbush
(Suction Liner)
Adjustment Bolt

Intake Flange
Seal
Retaining Stud

45

Effect of Throatbush Adjustment


Site A

Site B

Site C

Not Adjusted: Local Wear

Not Adjusted: Local Wear

Not Adjusted: Local Wear

Adjusted: Even wear pattern

Adjusted: Even wear pattern

Adjusted: Even wear pattern

Calgary Pump Symposium 2015

46

Effect of Throatbush Adjustment


Gouging Wear Reduced by 33 to 42%

Calgary Pump Symposium 2015

47

Additional 650 HT Photos

Calgary Pump Symposium 2015

48

Additional 650 HT Photos

Calgary Pump Symposium 2015

49

650 HT Wear Photos (3331 hours):


Throatbush
Generally smooth wear pattern:
18 24 mm wear adjacent to expelling vanes
50 mm divot a 6:00 oclock near eye (175 mm thick new)

Calgary Pump Symposium 2015

50

650 HT Wear Photos (3331 hours):


Throatbush
50 mm depression near eye at
6:00 oclock position:
175 mm thick new this location

Throatbush adjustments:
1 mm at 200 hours
8 mm at 1200 hours
10 mm at 2660 hours

19 mm
Total

Gouging wear can be reduced


with more frequent adjustments
Regardless, part would easily
achieve 4000 hours run time and
likely 8000 hours with rotation
and/or more frequent adjustment

Calgary Pump Symposium 2015

51

650 HT Wear Photos (3331 hours):


Volute and Frame Plate Liner Insert

Very smooth overall wear pattern.


Relatively minor 6 mm x 100 mm
( x 4) groove on fpli at 4:00
oclock.
Wear rates in the volute proper
range from 5.4 - 10.7 mm/1000 hr.
Wear life based on linear
progression at worst case location
predicted to be 10,000 hours till
hole through
Highest wear shifted to
approximately 120 degrees beyond
cutwater

Calgary Pump Symposium 2015

52

650 HT Wear Photos (3331 hours):


Volute Cutwater
Very smooth wear pattern:
No gouging or twin spiral,
serpents back wear pattern

58 mm wear (measured from


discharge flange):
17.4 mm/1000 hr wear rate
Greater than 12,000 hours till
hole through based on linear
projection of current wear rate

Calgary Pump Symposium 2015

53

650 HT Wear Photos (3331 hours):


Impeller
Front shroud in excellent
shape:
no obvious rounding over of
expelling vanes
smooth seal dam with
circular ID:
797 to 800 mm (760 mm new)

Trailing edge of main


pumping vanes in good
shape:
very minor gouging at OD

Calgary Pump Symposium 2015

54

650 HT Wear Photos (3331 hours):


Impeller
Main wear to
leading edge of
impeller vanes:
60 to 61.25
(72.4 new)*

7054 to 8598 hr
life projected to
20 vane length
* Both measured on longer pressure side of vane

Calgary Pump Symposium 2015

55

650 HT Wear: Operating Point Revisited


Aurora Tailings
system now has
two modes of
operation:
PSV to tails
distributor
PSV to composite
tails

Approximately 6 m
more head to tails
distributor

Calgary Pump Symposium 2015

56

650 HT Wear: Operating Point Revisited

Two distinct
system curves:
To CT on BEP
To TD 90% of
BEP at higher
head

Calgary Pump Symposium 2015

57

650 HT Wear: Operating Point Revisited


Operation at slightly lower flow rate results in
flatter velocity and velocity2 profiles:

Calgary Pump Symposium 2015

58

650 HT Wear: Operating Point Revisited


Operation at lower flow rates results in a shift in wear
from the design section to cutwater and beyond.

Calgary Pump Symposium 2015

59

650 HT Wear: Operating Point Revisited


Volute two dimensional wear model limited in the
presence of large particles:
Does not account for distance from impeller to volute
Does not account for gravity effects

For a top horizontal discharge orientation with a


uniform velocity distribution around the volute and
the presence of large particles, one can expect a
shifting of wear from the uppermost, furthest away
design section to the closer protruding cutwater
and lower area beyond the cutwater.
Calgary Pump Symposium 2015

60

650 HT Wear Summary


Based on observed wear at 3331 hours we are able to
provide revised, more conservative predictions:
Component

650 ULP Life


Observed

Requested Life

650 HTP Projected


Based on Observed

Impeller

2500 3500 hr

4250 hr

6635 8598 hr

Throatbush

3100 3800 hr

4250 hr

4250+ hr*

Volute

3500 5500 hr

8500 hr

8397 10264 hr

FPLI

4000+ hour

8500 hr

Same as volute

* Extremely conservative estimate. Double this value likely with more frequent adjustment

Obviously, the next goal is to provide further refinements


to achieve 8500 hours on all parts.

Calgary Pump Symposium 2015

61

Conclusion
The desire to maximize
bitumen recovery has
resulted in larger screen
size to minimize rejects.
Along with this increase
in screen size has come
step wise increases in
wear rates.
To provide adequate wear
life one can expect to see:
Larger pumps of lower
specific speed
Innovative design
features
Advanced materials

450 L

Calgary Pump Symposium 2015

650 LP
650 HT

62