The sizes quoted are the minimum and you should increase them if this does not impinge on
your design.
Just in case;
Circular
Using the minimum height of stowed cable as 3 times the locker diameter then
pi/4*dia^2 is the area and 3*dia is the stowed flat cable height
and pi/4*dia^2*3*dia = Vol = 2.356*dia^3
so that dia = 0.75*Vol^(1/3) or 0.75 times the cube root of Vol
Rectangular
Say the width of the wide side is W and the width of the narrow side is N. Call the
proportion W/N f so f =1 for a square and f = 1.5 for the limit as mentioned above.
The floor area = N*fN = fN^2
The diagonal = (N^2+f^2*N^2)^0.5 = N*(f^2+1)^0.5
Vol = The flat, stowed volume = area*3*diag
Vol = fN^2*3*N*(f^2+1)^0.5 = 3*f*N^3*(f^2+1)^0.5
still with me? Good!
so then N = [Vol/(3*f*(f^2+1)^0.5]^(1/3)
simplify this to N = Vol^(1/3)*a coefficient that depends on on f
Prop'n 1.00 to 1; N = 0.6177, W = 0.6177, diag = 0.8736
Prop'n 1.25 to 1; N = 0.5502, W = 0.6878, diag = 0.8808
Prop'n 1.50 to 1; N = 0.4977, W = 0.7466, diag = 0.8972