Documente Academic
Documente Profesional
Documente Cultură
Limit Switches
Proximity
Switches
Foot Switches
Foot Switch
Normally Open
Proximity Switch
Normally Open
Foot Switch
Normally Closed
Proximity Switch
Normally Closed
Flow Switch
Normally Open
Pressure or
Vacuum Switches
NP
Limit Switch
Neutral Position
Non-Actuated
Relay or
Timer Coil
Relay Contact
Normally Open
Pushbuttons
Pushbutton
Normally Open
Pushbutton
Normally Closed
Flow Switches
Relay Contact
Normally Closed
Pushbutton
Double Circuit
Vacuum or Pressure
Switch, Norm. Open
Liquid Level
Switches
Pushbutton
Mushroom Head
NP
Limit Switch
Neutral Position
Actuated
Vacuum or Pressure
Switch, Norm. Closed
Temperature
Switches
Liquid Level Switch
Normally Closed
Limit Switch
Maintained Position
Temperature Switch
Normally Open
Load Devices
Disconnect Switch
Pushbutton
Maintained Contact
Meters
VM
Voltmeter
Toggle Switches
AM
Toggle Switch
Temperature Switch
Normally Closed
Load Device
Solenoid Valve, etc.
Disconnect
Switch
Ammeter
80
Selector Switches
1
Miscellaneous
2
Alternate Symbol
Rotary Selector Switch
Bridging Contacts
Resistors
Potentiometer
Selector Switch
2-Position
1
Thermal Overload
Pilot Lamp
Conductors
Not Connected
Alternate Symbol
Thermal Overload
Earth Ground
Conductors
Connected
Circuit Interrupter
Resistor
Battery
H1
Rheostat
Fuse
X1
Circuit Breaker
H3
Rectifier
Rotary Selector
Switches
AC
Horn, Siren, etc.
H2
Tapped Resistor
X2
Selector Switch
3-Position
Capacitors
H4
Heating Element
AC
Bridge Rectifier
Control Transformer
Buzzer
10
11
Capacitor, Fixed
12
Alternate Symbol
Rotary Selector Switch
Non-Bridging Contacts
Capacitor Adjustable
Three-Phase
Electric Motor
Bell
15
A
Rotary Selector Switch
Bridging Contacts
Capacitor, Electrolytic
DEVICE DESIGNATIONS
These abbreviations are intended for use on diagrams in
connection with the corresponding symbol from the charts
above to amplify the information on the function of a device.
Suitable prefix numbers (1, 2, 3, 4, etc.) may be added to distinguish between several similar devices. Suffix letters (A, B,
C, D, etc.) may be added to distinguish between several sets
of contacts on the same device.
Examples: 1-CR-A, 1-CR-B, 3-CR-A, etc.
AM - Ammeter
CAP - Capacitor
CB - Circuit Breaker
CI - Circuit Interrupter
CON - Contractor
CR - Control Relay
CS - Cam Switch
CTR - Counter
F - Forward
FB - Fuse Block
Thermocouple
PB - Pushbutton
POT - Potentiometer
PRS - Proximity Switch
PS - Pressure Switch
R - Reverse
REC - Rectifier
RECEP - Receptacle
RES - Resistor
RH - Rheostat
RSS - Rotary Selector Switch
S - Switch
Terminal Board
SOC - Socket
SOL - Solenoid
SS - Selector Switch
T - Transformer
TAS - Temp. Actuated Switch
TB - Terminal Block
T/C - Thermocouple
TGS - Toggle Switch
TR - Time Delay Relay
VM - Voltmeter
VS - Vacuum Switch
Published by:
WOMACK EDUCATIONAL PUBLICATIONS
Womack Machine Supply Co.
13835 Senlac Dr.
Farmers Branch, TX 75234
Tel: 800-859-9801
Fax: 214-630-5314
www.womack-educational.com