PCP0325E

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

PACKAGED
AIR CONDITIONERS

<Duct Connection Series>


COOLING ONLY/HEAT PUMP 50Hz/60Hz

DUCT CONNECTION
LOW STATIC PRESSURE TYPE

Cautions on product corrosion

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.

JMI-0107

JQA-1452

About ISO 9001


ISO 9001 is a plant certification system
defined by the International Organization for
Standardization (ISO) relating to quality
assurance. ISO 9001 certification covers
quality assurance aspects related to the
design, development, manufacture,
installation, and supplementary service of
products manufactured at the plant.

About ISO 14001


ISO 14001 is the standard defined by the
International Organization for Standardization
(ISO) relating to environmental management
systems. Our group has been acknowledged
by an internationally accredited compliance
organisation as having an appropriate
programme of environmental protection
procedures and activities to meet the
requirements of ISO 14001.

Dealer

DUCT CONNECTION
MIDDLE STATIC PRESSURE TYPE

DUCT CONNECTION
HIGH STATIC PRESSURE TYPE

Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global_ac/
c All rights reserved
Printed in Japan 11/07/005 Y.K.

Specifications, designs and other content appearing in this brochure are current as of November 2007 but subject to change without notice.

Creates elegant air conditioning

Product Lineup
HP
kW
Btu/h
kcal/h

Capacity

......For high outdoor


temperature use

Cooling only

Note:
Cooling capacities are based on the following conditions:
Suction temperature: 27CDB, 19.0CWB Outdoor temperature: 35CDB
Equivalent ref. piping: 5 m (Horizontal) (7.5 m for LU type)

(50C54C)

Refer to the Specifications


on P13P24 for details.

1
2.6
8,900
2,250

1.5
3.5
11,900
3,010

2
5.3
18,100
4,560

2.5
6.97
23,800
6,000

3
8.7
29,600
7,500

FDBG25AVE
R25JV1

FDBG35AVE
R35JV1

FDBG50AVE

FDBG60AVE
R60GV1
R60GV1K
FDB60KVE
R60GVAL

FDBG71AVE

4
10.5
35,700
9,000

5
12.9
43,600
11,000

6
14.2
48,400
12,200

7
16.8
57,500
14,400

The values given for


1 HP2.5 HP is for FDBG type,
3 HP7 HP is for FDMG type,
8 HP20 HP is for FD type.

8
24.0
81,800
20,600

10
29.2
99,600
25,100

VE:
V1:
Y1:
VAL:
TAL:
YAL:

1 phase, 220-240V/220V, 50/60Hz


1 phase, 220-240V, 50Hz
3 phase, 380-415V, 50Hz
1 phase, 220V, 60Hz
3 phase, 220V, 60Hz
3 phase, 380V, 60Hz

15
47.2
163,500
41,200

20
58.4
199,400
50,200

Cooling only
Low
Static
Pressure
Type
Page 6

Indoor unit
50 Hz
60 Hz

Outdoor unit
Indoor unit
Outdoor unit

R50GV1
FDB50KVE
R50GVAL

R71FUV1Y1
FDB71KVE
R71FUVAL

S P ECIFICA TIO N S

Page 13, 19

Outdoor unit

Simultaneous Operation System (Page 9, 10, SPECIFICATIONS Page 18, 24)


Cooling only

Middle
Static
Pressure
Type
Page 7

S P ECIFICA TIO N S

FDMG

FDMG

FDMG

FD(Y)M

FD(Y)M

FD(Y)M

Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
60 Hz
Indoor unit
Outdoor unit

FDMG71AV1
RG71AV1Y1
FDYM03FAV1
R71LUV1Y1
FDYM03FAVAL
R71LUVAL
FDM03FAVAL
R71FUVAL

Outdoor unit

R71LU

50 Hz

FDMG100AV1
R100FUV1Y1
FDYM04FAV1
R100LUV1Y1
FDYM04FAVAL
R100LUVAL
FDM04FAVAL
R100FUVAL

FDMG125AV1
R125FUY1
FDYM05FAV1
R125LUY1
FDYM05FAVAL
R125LUTAL/YAL
FDM05FAVAL
R125FUTAL

8HP (200 class)

Twin Multi

FDMG140AV1
RG140AY1
FDYM06FAV1
R140LUY1
FDYM06FAVAL
R140LUTALYAL
FDYM06FAVAL
R140KUTALK

FDMG180AV1
RG180AY1

10HP (250 class)

Triple Multi

C/O

FDYM04FAV1X 2
FDYM03FAV1X 3
R200KUY1
FDYM04FAVAL X 2 FDYM03FAVAL X 3
60 Hz
R200KUTALYAL
50 Hz

FDYM05FAV1X 2
R250KUY1
FDYM05FAVAL X 2
R250KUTALYAL

Outdoor Unit

Page 14, 20

Twin Multi

R100LU

R100FU

R125LU

R125FU

R71FU/RG71A

R140LU

R140KU
RG140AY1

RG180AY1

Cooling only
High
Static
Pressure
Type
Page 8

S P ECIFICA TIO N S

Indoor unit
50 Hz Outdoor unit
Outdoor unit (Type without factory-charged refrigerant)
Indoor unit
60 Hz Outdoor unit
Outdoor unit (Type without factory-charged refrigerant)

Page 15, 16,


21, 22

FD03KY1
R71FUY1

FD04KY1
R100FUY1

FD05KY1
R125FUY1

FD06KY1
RU06KY1

FD03KVAL
R71FUVAL

FD04KVAL
R100FUVAL

FD05KTAL
R125FUTAL

FD06KTAL
RU06KTAL

FD08KY1
RU08KUY1
RU08KY1
FD08KTAL
RU08KUTAL
RU08KTAL

FD10KY1
RU10KUY1
RU10KY1
FD10KTAL
RU10KUTAL
RU10KTAL

FD15KY1
RU08KUY1X2
RU08KY1X2
FD15KTAL
RU08KUTALX2
RU08KTALX2

FD20KY1
RU10KUY1X2
RU10KY1X2
FD20KTAL
RU10KUTALX2
RU10KTALX2

Outdoor unit

*For the combination of indoor and outdoor units, please refer to the specifications.

Product Lineup
HP

Capacity

Cooling

Heating

kW
Btu/h
kcal/h
kW
Btu/h
kcal/h

1.5
3.75
12,800
3,230
4.22
14,400
3,630

......For high outdoor


temperature use

Heat pump
2
5.20
17,800
4,470
5.80
19,800
4,990

Note:
Cooling capacities are based on the following conditions:
Suction temperature: 27CDB, 19.0CWB Outdoor temperature: 35CDB
Equivalent ref. piping: 5 m (Horizontal) (7.5 m for LU type)

(50C54C)

2.5
6.15
21,000
5,290
7.0
23,900
6,020

Refer to the Specifications


on P13P24 for details.

3
7.7
26,200
6,600
7.9
27,000
6,800

4
10.4
35,300
8,900
11.2
38,100
9,600

5
12.8
43,600
11,000
14.2
48,400
12,200

6
14.2
48,400
12,200
16.3
56,000
14,000

The values given for


1.5 HP2.5 HP is for FDYB type,
3 HP6 HP is for FDYM type,
8 HP20 HP is for FDY type.

8
22.2
75,700
19,100
23.2
79,200
20,000

10
27.1
92,500
23,300
29.5
100,700
25,400

VE:
V1:
Y1:
VAL:
TAL:
YAL:

1 phase, 220-240V/220V, 50/60Hz


1 phase, 220-240V, 50Hz
3 phase, 380-415V, 50Hz
1 phase, 220V, 60Hz
3 phase, 220V, 60Hz
3 phase, 380V, 60Hz

15
43.5
148,000
37,400
44.8
153,000
38,500

20
53.0
181,000
45,600
56.8
194,000
48,800

Simultaneous Operation System (Page 9, 10, SPECIFICATIONS Page 17, 23)


8HP (200 class)

Heat pump
Low
Static
Pressure
Type
Page 6

50 Hz
60 Hz

Indoor unit
Outdoor unit
Indoor unit
Outdoor unit

Double Twin Multi

FDYB35KAVE
RY35FV1A

FDYB50KAVE
RY50GAV1A
FDYB50KAVE
RY50GVAL

FDYB60KAVE
RY60GAV1A
FDYB60KAVE
RY60GVAL

FDYB71KAVE
RY71LUV1Y1
FDYB71KAVE
RY71FUVAL

10HP (250 class)

Double Twin Multi

H/P

S P ECIFICA TIO N S

Page 13, 19

50 Hz
60 Hz
Outdoor Unit

Outdoor unit
RY71LU

Triple Multi

RY71FU

FDYB50KAVEX 4
FDYB71KAVEX 3
RY200KUY1
FDYB50KAVEX 4
FDYB71KAVEX 3
RY200KUTALYAL

FDYB60KAVEX 4
RY250KUY1
FDYB60KAVEX 4
RY250KUTALYAL

Simultaneous Operation System (Page 9, 10, SPECIFICATIONS Page 18, 24)


8HP (200 class)

Twin Multi

Heat pump

50 Hz
60 Hz

Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
Outdoor unit

FDYM03FAV1
RY71LUV1Y1
FDYM03FAVAL
RY71FUVAL

FDYM04FAV1
RY100LUV1Y1
FDYM04FAVAL
RY100FUVAL

FDYM05FAV1
RY125LUY1
FDYM05FAVAL
RY125FUTAL

FDYM06FAV1
RY140LUY1
FDYM06FAVAL
RY140KUTALK
RY140LUTALYAL

S P ECIFICA TIO N S

Page 15, 21

Outdoor unit
RY71LU

Page 8

S P ECIFICA TIO N S

Twin Multi

H/P

Page 7

High
Static
Pressure
Type

10HP (250 class)

RY71FU

RY100LU

RY100FU

RY125LU

RY125FU

RY140LU

RY140KU

FDYM04FAV1X 2
FDYM03FAV1X 3
FDYM05FAV1X 2
RY200KUY1
RY250KUY1
FDYM04FAVAL X 2 FDYM03FAVAL X 3 FDYM05FAVAL X 2
60 Hz
RY200KUTALYAL
RY250KUTALYAL
50 Hz

Outdoor Unit

Middle
Static
Pressure
Type

Triple Multi

Heat pump

50 Hz
60 Hz

Indoor unit
Outdoor unit
Indoor unit
Outdoor unit

FDY06KAY1
RY140LUY1

FDY08KAY1
FDY10KAY1
FDY15KAY1
FDY20KAY1
RY200KUY1
RY250KUY1
RY200KUY1X2
RY250KUY1X2
FDY08KATALYAL
FDY10KATALYAL
FDY15KATALYAL
FDY20KATALYAL
RY200KUTALYAL RY250KUTALYAL RY200KUTALYALX2 RY250KUTALYALX2

Page 17, 23

Outdoor unit

*For the combination of indoor and outdoor units, please refer to the specifications.

Low Static
Pressure Type

Offering Higher-Quality Comfort


and a Wide-Ranging Lineup

Cooling only 50 Hz FDBG2571A 60 Hz FDB5071K


Heat pump FDYB3571KA
Ideal for quiet, beautiful living spaces
Suitable for condominiums and apartments,
houses and hotels, and similar living areas

Whisper Quiet

Easy Installation

Comfortable operation with low level of sound


Indoor unit

High

Low

FDBG60AVE

42 dBA

39 dBA

Small, lightweight and easy-to-install outdoor unit.

270mm

Durable
To achieve increased durability by improved resistance to
salt corrosion and atmospheric pollution, coated PE fins
(with special acryl pretreatment) are used for the heat
exchanger of the outdoor unit.

[Duc t c onnec tion]

To prevent increase in operation sounds, avoid installing the Air suction grille
directly below the Suction chamber.

Easy to Use

Central Control

Easy to read LCD wired remote controller and wireless


remote controller (Only for heat pump).

Many options are available for use with large-scale and


advanced-function centrally controlled systems
(Only for heat pump).

Cooling only

FDBG60/ 71AVE
FDB60/ 71KVE

FDBG25/ 35/ 50AVE


FDB50KVE

Digital remote
controller (option)

Remote controller
(option)

KRC47-2A, KRC47-4A

KRC47-1A

LCD wired remote


controller (option)

Wireless remote
controller (option)

Heat pump

FDYB60/ 71KAVE

FDYB35/ 50KAVE

BRC1C61

BRC4C62 (Separate type)

Adjus table external


s tatic pres s ure

Others

PE fin

Triple and double


twin multi operation

Interloc k c ontrol

C entral remote
c ontrol

E xternal c ommand
c ontrol

Control features
G roup c ontrol by
1 remote c ontroller

C ontrol by 2 remote
c ontrollers

*2

Auto-res tart

*2

S elf-diagnos is
func tion

Low gas pres s ure


detec tion

Timer s elec tor

Work & Servicing


Year-round c ooling
applic able

Automatic c ool/heat
c hange-over

Programme "Dry"

S witc hable fan


s peed

Hot s tart

Comfort

Feature

E mergency operation

Features

Model

*Signal
receiving
unit

* The wireless remote controller and signal receiving


unit are sold as a set.

Pre-c harged for


up to 30 m

Whether it be a store or office, working people


require a comfortable indoor environment.
However, they do not wish to be disturbed by
unsightly equipment or loud sounds. By placing
the air conditioner in the ceiling, the rooms
design and finish remain attractive and
unblemished. With minimal operating sound,
people nearby are almost unaware of the units
presence. And a wide range of horsepower
levels accurately meets customer needs.
Simultaneous operation of 2 to 4 indoor units
provides enhanced comfort distributed to every
corner of a room.
Daikins packaged air conditioners, duct
connection seriesthe solution for a comfortable
environment.

S uc tion C hamber
Air Filter

Cooling only
Heat pump
5

*1

*1Applic able to R Y71LU outdoor units (for temp. down to 5C ) and R Y200LU R Y250LU outdoor units (for temp. down to 0C )
*2Applic able to R Y71LU outdoor units

* Please refer to "Control System" page 25.

Middle Static
Pressure Type

High Static
Pressure Type

Cooling only 50Hz FDMG71180AV1, FDYM0306FAV1


60Hz FDM0305FAVAL, FDYM0306FAVAL
Heat pump FDYM0306FA

Cooling only FD0320K


Heat pump FDY0620KA

Compact, quiet, and hardly affects the


appearance of the room.

Recommended for spacious and large-volume


areas because of its flexible installation

Suitable for an extensive range of


commercial facilities, offices, and homes.

Suitable for large stores, factories, and other


large areas, and for use with housing ducts in homes

Handy

Durable

Super Quiet 46dBA

Compact, 295 mm height design makes installation


possible where the ceiling space is limited. (FDYM)

The special acryl precoated fin (PE fin) for anti-corrosion


treatment on the outdoor unit heat exchanger realises
greater resistance against salt damage and atmospheric
pollution than ever.

Comfortable operation with low level of sound

Durable

Easy to Use

Highly durable outdoor unit has PE fins for improved


resistance to salt corrosion and atmospheric pollution.

Easy to read LCD wired remote controller and wireless


remote controller. (FD(Y)M only)

Easy to Use

Central control

Easy to read LCD wired remote controller and wireless


remote controller (Only for heat pump).

Air conditioner
295mm

Ordinary duc t
(Field s upply)

Ordinary duc t
(Field s upply)

305mm or more

Air blow

Air intake

Whisper Quiet 39dBA

FDYM03FAV1

Many options are available for use with large-scale and


advanced-function centrally controlled systems. (FD(Y)M only)

Indoor unit with low level of sound.

Cooling only

FDMG71AV1

FDMG100-140AV1

FDMG180AV1

Digital remote
controller (option)

Remote controller
(option)

KRC47-2, KRC47-4

KRC47-1

Central control

for FD03K

Many options are available for use with large-scale and


advanced-function centrally controlled systems.

FD: Remote controller


( option )

FDY: LCD wired remote


controller ( option )

KRC47-3A

FDY: Wireless remote


controller (option)

*Signal
receiving unit

BRC1C61

BRC4C62

(Separate type)

* The wireless remote controller and signal receiving unit are sold as a set.

Cooling only

FD03KY1/VAL

FD04KY1/VAL

FD05KY1/TAL

FD06KY1/TAL

FD08KY1/TAL

FD10KY1/TAL

FD15KY1/TAL

FD20KY1/TAL

LCD wired remote controller (option)

Cooling only

*1Applic able to R 71LU R 140LU outdoor units (for temp. down to 15C ) (An option is required.)
* Please refer to "Control System" page 25.
*2Applic able to R Y71LU R Y140LU outdoor units (for temp. down to 5C ) and R Y200LU R Y250LU outdoor units (for temp. down to 0C )
3
* Applic able to R (Y)71LU 140LU outdoor units

Heat pump

Adjustable external
static pressure

PE fin

Interloc k c ontrol

Others
C entral remote
c ontrol

*2

E xternal c ommand
c ontrol

*2

C ontrol by
2 remote c ontrollers

*1

FDY20KAY1/TAL YAL

Control features

Work & Servicing

Auto-restart

*4

FDY15KAY1/TAL YAL

G roup c ontrol by
1 remote c ontroller

Comfort

Feature

Model

FDY10KAY1/TAL YAL

S elf-diagnosis
func tion

Adjus table external


s tatic pres s ure

PE fin

Twin and triple


multi operation

FDY08KAY1/TAL YAL

Features

Others
Interloc k c ontrol

C entral remote
c ontrol

E xternal c ommand
c ontrol

G roup c ontrol by 1
remote c ontroller

*3

C ontrol by 2 remote
c ontrollers

*2

*3

Auto-res tart

*3

S elf-diagnos is
func tion

*3

E mergenc y
operation

*1

Timer s elec tor

Low gas pres s ure


detec tion

Year-round c ooling
applic able

Automatic c ool/heat
c hange-over

Programme "Dry"

S witc hable fan


s peed

Control features

Work & Servicing


Pre-c harged for
up to 30 m

Heat pump

Hot s tart

Comfort

Feature

Cooling FDMG
only
FDYM

FDY06KAY1/--

(Separate type)

* The wireless remote controller and signal


receiving unit are sold as a set.

Features

Model

BRC4C64 BRC4C62

FDYM04FA-06FAV1/VAL

E mergenc y
operation

FDYM03FAV1/VAL

*Signal
receiving
unit

Low gas pressure


detec tion

Cooling Only Heat Pump

Heat pump

Pre-c harged for


up to 30 m

Wireless remote controller (option)

Timer selec tor

Heat pump

Year-round c ooling
applic able

BRC1C61
Wire for remote controller is field supply.

Automatic c ool/heat
c hange-over

FD(Y)M04FA-06FAV1/VAL

Hot start

FD(Y)M03FAV1/VAL

*3
*4

*1Applic able to R Y140LU outdoor units (for temp. down to 5C ) and R Y200LU R Y250LU outdoor units (for temp. down to 0C )
*2Applic able to R (Y)140LU outdoor units
*3R equired to c hange the pulley
*4FDY06-10 only

*3
* Please refer to "Control System" page 25.

Simultaneous operation system

MULTI SERIES
[Twin & Triple & Double Twin Multi Application Operation]

Piping Guideline

Simultaneously operates 2 to 4 indoor units using


a single outdoor unit.

Twin Multi Application

In large interior spaces a single indoor unit may


not be able to provide uniform comfort. Installation
of 2 to 4 units can provide an effective solution.

Triple Multi Application

Sub unit

Main unit

L1

Branch
piping kit

In a single-floor office, for example, positioning 4 units at


strategic locations realises comfortable airflow that
reaches every inch of the room.

Main pipe L
Outdoor unit

Outdoor unit

Double Twin Multi Application


Sub unit

Sub unit

Main unit

Triple Multi Application


L3

L4

L5

L6

L1
Branch piping kit *

L3

Remote
controller

Main
pipe L

Sub unit

Twin Multi Application

L2

Main unit

Branch
piping kit

Remote
controller

Note: This type of system does not allow individual control or independent operation of
indoor units. It is not the best choice for large rooms with partitions.

Sub unit

L1

L2

Installing multiple units is


economical and realises comfort!

Lower cost of installation than for individual pair type


Less space needed for outdoor units
Enhanced comfort from distributed indoor units

Sub unit

Branch piping kit *

L2

Remote
controller

Branch
piping kit

Main pipe L
Outdoor unit

Double Twin Multi Application

Simultaneous operation system

Branch piping kit *

Twin Multi Application

Maximum piping length

Maximum branch piping length

*1 Max ( L1, L2 )

Maximum length difference of branch pipe

Max ( L1, L2 )

50m
20m

Max ( L1, L2 ) *2 Min ( L1, L2 ) 10m

Triple Multi Application


L

Max ( L1, L2, L3 )


Max ( L1, L2, L3 )

Double Twin Multi Application

50m
20m

Max ( L1, L2, L3 ) Min ( L1, L2, L3 )

L + Max ( L1, L2 ) + Max ( L3, L4, L5, L6 )

50m

Max ( L1, L2 ) + Max ( L3, L4, L5, L6 ) 20m


( L2 + L6 ) ( L1 + L3 ) 10m
L2 L1 10m
10m
L4 L3 10m
L6 L5 10m
In case of L1 L2, L3 L4, L5 L6

Maximum height difference between outdoor unit and indoor units

30m

30m

30m

Maximum height difference between the indoor units

0.5m

0.5m

0.5m

*1 .Max ( L1, L2 ) means maximum length out of L1 and L2.


*2 .Min ( L1, L2 ) means minimum length out of L1 and L2.
* Branch piping kit is sold separately. Please use the model indicated on the back cover.

* Please refer to page 13,14,19,20 for the specification.

10

Abundance of features for providing comfortable


air-conditioning for stores and offices

Outdoor Unit
Compact unit offers
quiet operation.

Neighbor-friendly

Comfort
Switchable fan speed

High setting provides maximum reach while low


setting minimises drafts.

Programme "Dry"

Dehumidification is computer controlled to prevent


abrupt and uncomfortable changes in air
temperature. Useful for reducing discomforting
humidity without uncomfortable cooling of the room.

Hot start

Uncomfortable cold air draft is not discharged


when heating operation starts or when switching
to heat after defrosting.

Automatic cool/heat
change-over (Heat pump only)

Detects difference in preset temperature and


actual room temperature and automatically
switches to cooling or heating accordingly.

Timer selector

Control features
Auto-restart

If there is a power outage while the equipment is


operating, operations will restart in the same mode as
before the power cut when electricity is restored.

Control by 2 remote controllers

Using 2 remote controllers you can operate the


equipment locally or from a remote location.
Note: When a wireless remote controller is used, remote control by two remote
controllers is not possible.

Control by 1 remote controller

You can turn up to 16 indoor units on/off with a


single remote controller. (When using connected
indoor units, the settings must all be the same and
on/off will be simultaneous.)

External command control

Operation and surveillance is carried out using the


contact signal from the operation control box in the
building surveillance (security) room.

Operation starts when the preset time of the ON


timer elapses and stops when the preset time of
the OFF timer elapses.

Central remote control

Work & Servicing

Interlock control with HRV

Pre-charged for up to 30 metres

Optional central remote controller enables


centralised control of up to 1024 indoor units (64
groups) from up to 1 kilometer away.
Enables interlock control with external equipment
such as heat reclaim ventilation (HRV).

(Applies to RY71LUV1/Y1, R-LUV1/Y1 and R-LUYAL/TAL/YAL)

If refrigerant piping length does not exceed 30 m, there is


no need for on-site gas charging.

Low gas pressure detection

Insufficient gas charging is normally hard to detect.


During post-installation trials and regular inspection
procedures, the refrigerant level is monitored by
computer to maintain proper gas pressure.

Emergency operation

If there is a malfunction elsewhere in the system,


the fan or compressor can still be operated.

Self diagnosis function


The operating parameters of indoor and outdoor units,
and sensor data at critical locations throughout the
system, are constantly monitored using a
microcomputer. To facilitate quick response in the
event of a malfunction, a message appears on the
LCD of the remote controller and an LED on the unit
illuminates.
Note: The features of each individual unit are shown in the tables on the page where the unit is introduced.

11

Others

Twin / triple/Double twin


multi application

Simultaneously operates 2-4 indoor units with a


single outdoor unit.

PE fin

To achieve increased durability by improved


resistance to salt corrosion and atmospheric
pollution, coated PE fins (with special acryl
pretreatment) are used for the heat exchanger of
the outdoor unit.

Adjustable external
static pressure

Quiet & Powerful


Fitted with wide inlet fan
(Applies to R(Y)71LU140LU)

Fully shaped aerodynamic propellers are designed to push air with a


large wing surface. This
provides both high blow Wide inlet fan
volume and quiet opera- (Applies to
tion with minimal turbu- R(Y)71LU140LU)
lence.

Fitted with Super Aero Grille


(Applies to R(Y)71LU140LU)

To suppress turbulence
and achieve quiet operation, the curved ribs of
the grille are optimised
to meet the outflow of air.

Equipped with scroll


compressor for
quiet operation

R(Y)71LU

R(Y)100LU

R(Y)125LU
Smoother and easier

Easily replaceable

Compact

Installation
and maintenance

Slim-design and low-profile


compact outdoor units

4-direction piping affords


more freedom of layout

(Applies to R(Y)71LU140LU)

Compactly designed outdoor unit


with interior layout optimised for the
smooth flow of air.

(Applies to R(Y)71LU140LU)

Facilitates pump down


(Refrigerant recovery function)

Weight reduced

A pump-down switch is provided to


make it easier to collect refrigerant if
the unit is to be moved or layout
modified. This lessens environmental
impact by preventing the release of
refrigerant into the atmosphere.

(Applies to R(Y)71LU125LU)

Delivery and installation are easier.

New

Previous

89 kg

108 kg
RY100KUV1

Takes installation environment


into consideration

RY100LUV1

Durability

Curved Super Aero Grille restricts


the spread of exhaust gas and fits in
the same space as previous outdoor
units.

Heat exchange fins provided


with anti-corrosion treatment
(All models)

(Applies to R(Y)125LU and 140LU)

Smooth running, minimal vibration, low operating sound.

Suited for year-round cooling


applications

50

Cooling is efficient even in winter


when indoor temperatures are higher
than those outside, such as in underground public spaces or offices with
many computers.

R(Y)140LU

500

To achieve increased durability by


improved resistance to salt corrosion
and atmospheric pollution, coated PE
fins (with special acryl pretreatment)
are used for the heat exchanger of
the outdoor unit.
Construction
Non-treated fin

Alminium

PE fin

Hydrophilic film
Alminium
C orros ion res is tanc e
ac rylic res in

(mm)

R(Y)71LU

Heat pump/RY71140LU: possible up to -5C


Cooling only/R71140LU: possible up to -15C
(An option is required.)

Flexible design
for large room
or multi use

200 and 250 class models can


be combined for centralised
horizontal series installation
Common width and depth make
series installation easy.

RU08/10K are available in two


types depending on installation
conditions
RU08/10KU models are factory
shipped with refrigerant charged for
5 meters of piping.
RU08/10K models are factory
shipped with no refrigerant charged.

R(Y)200KU

R(Y)200KU

R(Y)250KU

690mm
1300mm(min.) 1300mm(min.) 1300mm(min.)
* Refer to engineering data for instllation service space.

Allowed refrigerant pipe length and Height difference


Pre-charged
*1

Max. length
*2

Max. height
difference *2

R(Y)200KU

5m

(Equivalent length 70m)

50m

30m

R(Y)250KU

5m

(Equivalent length 70m)

50m

30m

Note : *1 Additional refrigerant charging is required if the refrigerant pipe is


longer than the length.
*2 Length when refrigerant pipe length is 5m and when the maximum
height difference between the outdoor and indoor unit is 0m.
For more information, see the Engineering data.

Piping can be drawn out from three


directions - front, left side or below.

12

S P ECIFICA TIO N S ......For high outdoor temperature use


LO W S TA TIC P R ES S U R E

50Hz

FDB G / FDY B

M IDDLE S TA TIC P R ES S U R E

50Hz

FDM G / FDY M

Cooling only

Cooling only
Model

Indoor unit

FDBG25AVE

FDBG35AVE

FDBG50AVE

Outdoor unit

R25JV1

R35JV1

R50GV1

VE: 1 phase, 220-240 V/220 V, 50/60 Hz


V1: 1 phase, 220-240 V, 50 Hz

Power Supply
kW
Btu/h
kcal/h
kW
m3/min
cfm

Cooling capacity
(*1) (1)/(2)

Power consumption
Indoor
unit (*4)

S P ECIFICA TIO N S ......For high outdoor temperature use

(*1) (1)/(2)

Airflow rate (H/L)

Fan
Driving system
Sound level (H/L)
dBA
Dimensions (HX WX D)
mm
Weight
kg
Operation range
CWB
Compressor
Outdoor
Motor output
kW
unit
Refrigerant Charge (R22)
kg
Sound level (*3)
dBA
Dimensions (HX WX D)
mm
Weight
kg
Operation range
CDB
Liquid
mm
Piping
Gas
mm
connections
Indoor unit
Drain
Outdoor unit
mm
Max. piping length
m
Max. Installation level difference
m
Heat insulation

2.64/2.60
9,000/8,900
2,270/2,250
0.88/0.87

3.54/3.50
12,100/11,900
3,040/3,010
1.25/1.24
13/11
458/388

22

41/38
260X 900X 580

5.34/5.30
18,200/18,100
4,590/4,560
2.06/2.05
Direct drive (2 speed)
23

FDBG60AVE
FDBG71AVE
R60GV1
R71FUV1Y1
R60GV1K
VE: 1 phase, 220-240 V/220 V, 50/60 Hz
V1: 1 phase, 220-240 V, 50 Hz
Y1: 3 phase, 380-415 V, 50 Hz
7.03/6.97
7.80/7.70
24,000/23,800
26,600/26,200
6,050/6,000
6,700/6,600
2.76/2.75
2.82/2.80
18/15
635/529
42/39
260X 1,300X 580
31

14 to 25
14 to 23
Hermetically sealed type
Hermetically sealed rotary type
0.7
1.1
1.7
2.2
0.8 (Charged for 10 m) 1.0 (Charged for 10 m) 1.20 (Charged for 10 m) 1.50 (Charged for 5 m) 2.10 (Charged for 5 m)
46
48
49
54
52
560X 695X 265
540X 750X 270
685X 800X 300
816X 880X 370
27
33
42
61
87 (V1), 84 (Y1)
19.4 to 46
19.4 to 54
19.4 to 46, (K)19.4 to 54
21 to 52
6.4 (Flare)
9.5 (Flare)
9.5 (Flare)
12.7 (Flare)
15.9 (Flare)
3/4B
18.0 (Hole)
26.0 (Hole)
25
30
50 (Equivalent length 70 m)
15
30
Both liquid and gas pipes

Indoor unit
Outdoor unit

Model
Power Supply
Cooling capacity
(*1) (1)/(2) (*5)

Power consumption
Indoor
unit

Sound level (H) (*3)


Dimensions (HX WX D)
Weight
Operation range
Compressor
Outdoor
Motor output
unit
Refrigerant Charge (R22)
Sound level (*3)
Dimensions (HX WX D)
Weight
Operation range
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation

FDMG100AV1
FDMG125AV1
FDMG140AV1
R100FUV1Y1
R125FUY1
RG140AY1
V1: 1 phase, 220-240 V, 50 Hz Y1: 3 phase, 380-415 V, 50 Hz
10.6/10.5
13.1/12.9
14.5/14.2
36,100/35,700
44,500/43,600
49,400/48,400
9,100/9,000
11,200/11,000
12,500/12,200

FDMG180AV1
RG180AY1

kW
Btu/h
kcal/h

8.8/8.7
30,000/29,600
7,600/7,500

kW

3.15/3.13

4.08/4.04

4.89/4.85

5.25/5.25

6.45/6.45

m3/min
cfm
dBA
mm
kg
CWB

23
811
42
305X 1,350X 680
43

34
1,200
44

37
1,306
45
305X 1,550X 680

42
1,412
46

42
1,482
47
305X 1,900X 680
58

(*1) (1)/(2)

Airflow rate (H)

FDMG71AV1
RG71AV1Y1

kW
kg
dBA
mm
kg
CDB
mm
mm
mm
mm
m
m

51

14 to 25

52

17.2/16.8
58,700/57,500
14,700/14,400

Hermetically sealed type


Hermetically sealed scroll type
2.2
3.0
3.75
4.5
4.5
2.4 (Charged for 5 m)
2.8 (Charged for 5 m) 2.9 (Charged for 5 m) 2.8 (Charged for 5 m)
52
56
57
55
56
816X 880X 370
1,215X 880X 370
1,345X 880X 370
87/84
117/109
110
113
114
21 to 52
21 to 50
9.5 (Flare)
15.9 (Flare)
19.1 (Flare)
3/4B
26.0 (Hole)
50 (Equivalent length 70 m)
30
Both liquid and gas piping

Cooling only
Indoor unit
Outdoor unit

Model

Cooling capacity
(*1) (1)/(2)

Heating capacity
(*2)

Indoor
unit

(*1) (1)/(2)
(*2)

Airflow rate (H/L)

Fan
Driving system
Sound level (H/L)
Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Compressor
Outdoor
Motor output
unit
Refrigerant Charge (R22)
Sound level (Cooling/ Heating) (*3)
Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation

FDYB60KAVE
FDYB71KAVE
RY60GAV1A
RY71LUV1, Y1
VE: 1 phase, 220-240 V/220 V, 50/60 Hz
VE: 1 phase, 220-240 V/220 V, 50/60 Hz
V1: 1 phase, 220-240 V, 50 Hz
V1: 1 phase, 220-240 V, 50 Hz
Y1: 3 phase, 380-415 V, 50 Hz
3.79/3.75
6.24/6.15
7.8/7.7
5.27/5.20
12,900/12,800
18,000/17,800
21,300/21,000
26,600/26,200
3,260/3,230
4,530/4,470
5,370/5,290
6,700/6,600
4.22
5.80
7.0
7.9
14,400
19,800
23,900
27,000
3,630
6,020
6,800
4,990
1.51/1.50
2.01/2.00
2.38/2.36
3.08/3.08 (V1)/3.06/3.06 (Y1)
1.33
1.78
2.29
2.91 (V1)/2.88 (Y1)
13/11
18/15
460/388
635/529
Direct drive (2 speed)
41/ 38
43/ 40
260X 900X 580
260X 1,300X 580
22
23
31
14 to 23
12 to 25
15 to 28
15 to 27
Hermetically sealed rotary type
Hermetically sealed scroll type
1.3
2.2
2.24
1.7
1.12 (Charged for 10 m)
1.75 (Charged for 5 m)
1.55 (Charged for 10 m)
2.8 (Charged for 30 m)
47/48
54/54
49/49
48/49
540X 750X 270
685X 880X 350
685X 800X 300
770X 900X 320
41
75
51
73 (V1), 72 (Y1)
19.4 to 46
-5 to 46
-10 to 15.5
-10 to 15
6.4 (Flare)
9.5 (Flare)
12.7 (Flare)
15.9 (Flare)
3/4B
18.0 (Hole)
26.0 (Hole)
20
30
50 (Equivalent length 70 m)
15
30
Both liquid and gas pipes
FDYB35KAVE
RY35FV1A

Power Supply

Cooling
Power
consumption Heating

Indoor unit
Outdoor unit

Model

Heat pump

kW
Btu/h
kcal/h
kW
Btu/h
kcal/h
kW
kW
m3/min
cfm
dBA
mm
kg
CWB
CDB
kW
kg
dBA
mm
kg
CDB
CWB
mm
mm
mm
m
m

FDYB50KAVE
RY50GAV1A

Power Supply

kW
Btu/h
kcal/h

Cooling capacity
(*1) (1)/(2)

Power consumption
Indoor
unit

FDYM03FAV1
R71LUV1Y1

(*1) (1)/(2)

Airflow rate (H)

Sound level (H) (*3)


Dimensions (HX WX D)
Weight
Operation range
Compressor
Outdoor
Motor output
unit
Refrigerant Charge (R22)
Sound level (*3)
Dimensions (HX WX D)
Weight
Operation range
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation

kW
m3/min
cfm
dBA
mm
kg
CWB
kW
kg
dBA
mm
kg
CDB
mm
mm
mm
mm
m
m

7.8/7.7
26,600/ 26,200
6,700/ 6,600
(V1) 3.25/ 3.25
(Y1) 3.23/ 3.23
20
706
295X 1,100X 680
42
2.24
2.8 (Charged for 30 m)
48
770X 900X 320
72 (V1), 71 (Y1)
15.9 (Flare)

FDYM04FAV1
FDYM05FAV1
R100LUV1Y1
R125LUY1
V1: 1 phase, 220-240 V, 50 Hz Y1: 3 phase, 380-415 V, 50 Hz
10.6/10.5
13.0/12.8
36,100/ 35,700
44,500/43,600
9,100/ 9,000
11,200/11,000
(V1) 4.08/4.08
5.06/5.06
(Y1) 4.03/4.03
26
35
917
1,235
39
44
295X 1,500X 680
56
57
14 to 25
Hermetically sealed scroll type
3.00
3.75
3.7 (Charged for 30 m)
3.7 (Charged for 30 m)
49
49
1,170X 900X 320
87 (V1), 84 (Y1)
98
21 to 46, -15 to 46 (Option installed)(*4)
9.5 (Flare)
19.1 (Flare)
VP25 ( 25I.D. , 32O.D. )
26.0 (Hole)
50 (Equivalent length 70 m)
30
Both liquid and gas piping

FDYM06FAV1
R140LUY1
14.5/14.2
49,400/48,400
12,500/12,200
5.18/ 5.18
37
1,306
46

4.50
4.1 (Charged for 30 m)
54
1,345X 900X 320
109

Notes: (*1). Cooling capacities are based on the following conditions:


(1) Suction temperature: 27CDB, 19.5CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Suction temperature: 27CDB, 19.0CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal).(R71LU-R140LU is 7.5 m)
(*2). Heating capacities are based on the following conditions:
Suction temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)
(*3). Sound level is anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
(*4). This value is for when year-round cooling kit (option) is installed.
The above performance data based on the power supply of 220 V (380 V).
The power consumption shown above is that of the outdoor unit only. The power consumption of the indoor unit varies according to setup conditions, so refer to the engineering data to
obtain the relevant figure.
(*5). Capacities show gross capacities which do not include a deduction for evaporator fan motor heat.

Notes: (*1). Cooling capacities are based on the following conditions:


(1) Suction temperature: 27CDB, 19.5CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Suction temperature: 27CDB, 19.0CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal).(RY71LU is 7.5 m)
(*2). Heating capacities are based on the following conditions:
Suction temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal).(RY71LU is 7.5 m)
(*3). Sound level is anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
(*4). With return chamber.
The above performance data based on the power supply of 220 V (380 V).
The power consumption shown above is that of the outdoor unit only. The power consumption of the indoor unit varies according to setup conditions, so refer to the engineering data to
obtain the relevant figure.

13

14

S P ECIFICA TIO N S ......For high outdoor temperature use


FD ( Y ) M

M IDDLE S TA TIC P R ES S U R E
Heat pump

Indoor unit
Outdoor unit

Model
Power Supply
Cooling capacity
(*1) (1)/(2)

Heating capacity
(*2)

Cooling
Power
consumption Heating
Indoor
unit

(*1) (1)/(2)
(*2)

Airflow rate (H)

Sound level
Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Compressor
Outdoor
Motor output
unit
Refrigerant Charge (R22)
Sound level (Cooling/ Heating) (*3)
Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation

S P ECIFICA TIO N S ......For high outdoor temperature use


50Hz

FDYM03FAV1
RY71LUV1Y1

kW
Btu/h
kcal/h
kW
Btu/h
kcal/h
kW
kW
m3/min
cfm
dBA
mm
kg
CWB
CDB
kW
kg
dBA
mm
kg
CDB
CWB
mm
mm
mm
mm
m
m

FDYM04FAV1
FDYM05FAV1
RY100LUV1Y1
RY125LUY1
V1: 1 phase, 220-240 V, 50 Hz Y1: 3 phase, 380-415 V, 50 Hz
7.8/ 7.7
10.5/10.4
13.0/12.8
26,600/26,200
35,700/35,300
44,500/43,600
6,700/6,600
9,000/8,900
11,200/11,000
7.9
11.2
14.2
27,000
38,100
48,400
6,800
9,600
12,200
(V1) 3.19/3.19, (Y1) 3.17/3.17 (V1) 4.00/4.00, (Y1) 3.95/3.95
4.99/4.99
(V1) 2.95, (Y1) 2.92
(V1) 3.91, (Y1) 3.86
4.75
20
26
35
706
917
1,235
39
44
295X 1,100X 680
295X 1,500X 680
42
56
57
12 to 25
15 to 27
Hermetically sealed scroll type
2.24
3.00
3.75
2.8(Charged for 30 m)
3.7 (Charged for 30 m)
3.7 (Charged for 30 m)
48/49
49/52
49/52
770X 900X 320
1,170X 900X 320
73 (V1), 72 (Y1)
101
89 (V1), 86 (Y1)
-5 to 46
-10 to 15
9.5 (Flare)
15.9 (Flare)
19.1 (Flare)
VP25 ( 25I.D. , 32O.D. )
26.0 (Hole)
50 (Equivalent length 70 m)
30
Both liquid and gas piping

FDYM06FAV1
RY140LUY1
14.5/14.2
49,400/48,400
12,500/12,200
16.3
56,000
14,000
5.10/5.10
4.96
37
1,306
46

4.50
4.1 (Charged for 30 m)
54/56
1,345X 900X 320
112

Notes: (*1). Cooling capacities are based on the following conditions:


(1) Suction temperature: 27CDB, 19.5CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Suction temperature: 27CDB, 19.0CWB Outdoor temperature: 35CDB Equivalent ref. piping: 7.5 m (Horizontal).
(*2). Heating capacities are based on the following conditions: Suction temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 7.5 m (Horizontal).
(*3). Sound level is anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
The above performance data based on the power supply of 220 V (380 V).
The power consumption shown above is that of the outdoor unit only. The power consumption of the indoor unit varies according to setup conditions, so refer to the engineering data to obtain the relevant figure.

H IG H S TA TIC P R ES S U R E
Cooling only

Indoor unit
Outdoor unit

Model
Power Supply
(*1) (1)/(2) (*6)

Indoor
unit

(*1) (1)/(2)

Airflow rate (H)

Fan
Driving system
Sound level
dBA
Dimensions (HX WX D)
mm
Weight
kg
Operation range
CWB
Compressor
Outdoor
Motor output
kW
unit
Refrigerant Charge (R22)
kg
Sound level (*3)
Dimensions (HX WX D)
Weight
Operation range
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation

Cooling only
Power Supply
Cooling capacity
(*1) (1)/(2) (*6)

S P ECIFICA TIO N S
H IG H S TA TIC P R ES S U R E
Cooling only
Power Supply
Cooling capacity
(*1) (1)/(2) (*4)

Indoor
unit

FD ( Y )

Indoor unit
Outdoor unit

Model

Power consumption

Power consumption

(*1) (1)/(2)

Airflow rate (H)

FD03KY1
R71FUY1

kW
Btu/h
kcal/h
kW
m3/min
cfm

Fan
Driving system
Sound level
dBA
Dimensions (HX WX D)
mm
Weight
kg
Operation range
CWB
Compressor
Outdoor
Motor output
kW
unit
Refrigerant Charge (R22)
kg
Sound level (*3)
Dimensions (HX WX D)
Weight
Operation range
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation

50Hz

dBA
mm
kg
CDB
mm
mm
mm
m
m

8.1/ 7.9
27,800/ 27,000
7,000/6,800
2.50/2.48
26
918
46
450X 650X 850
51
2.2
2.1
(Charged for 5 m)
52
816X 880X 370
84
15.9 (Flare)

FD04KY1
FD05KY1
R100FUY1
R125FUY1
Y1: 3 phase, 380-415 V, 50 Hz
11.0/10.8
14.0/13.8
37,700/36,900
47,600/46,800
9,500/9,300
12,000/11,800
3.52/3.48
4.19/4.15
30
46
1,059
1,620
Belt drive
49
450X 900X 850
59
72
14 to 25
Hermetically sealed reciplocating type
3.0
3.75
2.4
2.8
(Charged for 5 m)
(Charged for 5 m)
56
57
1,215X 880X 370
109
110
21 to 52
9.5 (Flare)
19.1 (Flare)
3/4B
26.0 (Hole)
50 (Equivalent length 70 m)
30
Both liquid and gas pipes

FD06KY1
RU06KY1
17.4/17.2
59,500/58,800
15,000/14,800
5.7/5.7
52
1,836
51
450X 1,130X 850
79
Hermetically sealed scroll type
4.5
3.0
(Charged for 5 m)
59
1,345X 880X 320
112

Indoor
unit

dBA
mm
kg
CDB
mm
mm

(*1) (1)/(2)

Airflow rate (H)

51
500X 1,130X 850
93
7.5
5.0
(Charged for 5 m)
60
1,220X 1,280X 690
185
12.7 (Flare)
25.4 (Brazing)

3/4B

FD10KY1
FD15KY1
RU10KUY1
RU08KUY1 2
Y1: 3 phase, 380-415 V, 50 Hz
29.7/29.2
48.6/47.9
101,200/ 99,600
166,000/163,500
25,500/25,100
41,800/41,200
9.9/9.8
15.0/14.8
83
136
2,930
4,800
Belt drive
53
58
500X 1,330X 850
625X 1,620X 850
104
161
14 to 25
Hermetically sealed scroll type
9.0
7.5X 2
6.1
5.0
(Charged for 5 m)
(Charged for 5 m)X 2
61
60 (*4)
(1,220X 1,280X 690)X 2
1,440X 1,280X 690
200
185X 2
21 to 52
15.9 (Flare)
12.7X 2 (Flare)
31.8 (Brazing)
25.4X 2 (Brazing)

50 (Equivalent length 70 m)
30
Both liquid and gas pipes

FD20KY1
RU10KUY1 2
59.3/58.4
202,400/199,400
51,000/ 50,200
19.8/19.6
166
5,860
60
625X 1,980X 850
187
9.0X 2
6.1
(Charged for 5 m)X 2
61 (*4)
(1,440X 1,280X 690)X 2
200X 2

1B

15.9X 2 (Flare)
31.8X 2 (Brazing)

FD08KY1
RU08KY1

kW
Btu/h
kcal/h
kW
m3/min
cfm

Fan
Driving system
Sound level
dBA
Dimensions (HX WX D)
mm
Weight
kg
Operation range
CWB
Compressor
Outdoor
Motor output
kW
unit
Refrigerant Charge (R22)
kg
Sound level (*3)
Dimensions (HX WX D)
Weight
Operation range
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation

24.3/24.0
83,000/81,800
20,900/20,600
7.5/7.4
68
2,400

mm
m
m

Indoor unit
Outdoor unit

Model

50Hz
FD08KY1
RU08KUY1

kW
Btu/h
kcal/h
kW
m3/min
cfm

Cooling capacity
Power consumption

FD ( Y )

dBA
mm
kg
CDB
mm
mm
mm
m
m

FD10KY1
FD15KY1
FD20KY1
RU10KY1
RU08KY1 2
RU10KY1 2
Y1: 3 phase, 380-415 V, 50 Hz
24.3/24.0
29.7/29.2
48.6/47.9
59.3/58.4
83,000/81,800
101,200/ 99,600
166,000/163,500
202,400/199,400
20,900/20,600
25,500/25,100
41,800/41,200
51,000/ 50,200
7.5/7.4
9.9/9.8
15.0/14.8
19.8/19.6
68
83
136
166
2,400
2,930
4,800
5,860
Belt drive
51
53
58
60
500X 1,130X 850
500X 1,330X 850
625X 1,620X 850
625X 1,980X 850
93
104
161
187
14 to 25
Hermetically sealed scroll type
7.5
9.0
7.5X 2
9.0X 2
5.0
6.1
5.0
6.1
(Field charge required for 5 m)(*5) (Field charge required for 5 m)(*5) (Field charge required for 5 m)(*5)X 2 (Field charge required for 5 m)(*5)X 2
60
61
60 (*4)
61 (*4)
(1,220X 1,280X 690)X 2
(1,440X 1,280X 690)X 2
1,220X 1,280X 690
1,440X 1,280X 690
177
190
177X 2
190X 2
21 to 52
12.7 (Brazing)
15.9 (Brazing)
12.7X 2 (Brazing)
15.9X 2 (Brazing)
25.4 (Brazing)
31.8 (Brazing)
25.4X 2 (Brazing)
31.8X 2 (Brazing)
3/4B
1B

50 (Equivalent length 70 m)
30
Both liquid and gas pipes

Notes: (*1). Cooling capacities are based on the following conditions:


(1) Suction temperature: 27CDB, 19.5CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Suction temperature: 27CDB, 19.0CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(*2). Heating capacities are based on the following conditions:
Suction temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)
(*3). Sound level is anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
(*4). The specification of the outdoor unit shows only one unit.
(*5). This is the amount of refrigerant required for piping of five metres or less. Since the unit does not contain refrigerant when shipped from the factory, it must be added at the
installation site. For details, please refer to the installation manual.
(*6). Capacities show gross capacities which do not include a deduction for evaporator fan motor heat.
The power consumption shown above is that of the outdoor unit only. The power consumption of the indoor unit varies according to setup conditions, so refer to the engineering data to
obtain the relevant figure.

Notes: (*1). Cooling capacities are based on the following conditions:


(1) Suction temperature: 27CDB, 19.5CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Suction temperature: 27CDB, 19.0CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(*2). Heating capacities are based on the following conditions: Suction temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)
(*3). Sound level is anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
(*4). Capacities show gross capacities which do not include a deduction for evaporator fan motor heat.
The power consumption shown above is that of the outdoor unit only. The power consumption of the indoor unit varies according to setup conditions, so refer to the engineering data to obtain the relevant figure.

15

16

S P ECIFICA TIO N S ......For high outdoor temperature use


H IG H S TA TIC P R ES S U R E

S P ECIFICA TIO N S ......For high outdoor temperature use

FD ( Y )

50Hz

Heat pump
Indoor unit
Outdoor unit

Model
Power Supply
Cooling capacity
(*1) (1)/(2) (*7)

Heating capacity
(*2) (*8)

Power
Cooling
consumption Heating
Indoor
unit

(*1) (1)/(2)
(*2)

Airflow rate (H)

Driving system
Fan
Sound level
Dimensions (HX WX D) (*4)
Weight
Cooling
Operation
range
Heating
Compressor
Outdoor
Motor output
unit
Refrigerant Charge (R22)
Sound level (Cooling/ Heating) (*3)
Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation

FDY10KAY1
FDY20KAY1
FDY08KAY1
FDY15KAY1
RY200KUY1
RY250KUY1
RY200KUY1 2
RY250KUY1 2
Y1: 3 phase, 380-415 V (4wires), 50 Hz
14.5/14.2
27.6/27.1
44.0/43.5
53.9/53.0
22.5/22.2
49,500/48,500
76,800/75,700
94,200/92,500
150,000/148,000
184,000/181,000
12,500/12,220
19,300/19,100
23,700/23,300
37,800/37,400
46,400/45,600
15.3
29.5
44.8
56.8
23.2
52,200
79,200
100,700
153,000
194,000
13,200
25,400
38,500
48,800
20,000
5.14/5.14
7.2/7.1
9.3/9.2
14.4/14.2
18.5/18.3
4.54
6.1
8.8
12.2
17.6
52
68
83
136
166
1,835
2,400
2,930
4,800
5,860
Belt drive
51
53
58
60
450X 1,130X 850
500X 1,130X 850
500X 1,330X 850
625X 1,620X 850
625X 1,980X 850
80
94
105
161
187
12 to 25
14 to 25
15 to 27
Hermetically sealed scroll type
4.5
5.5
9.0
5.5X 2
9.0X 2
4.1 (Charged for 30 m) 4.0 (Charged for 5 m) 5.5 (Charged for 5 m) 4.0 (Charged for 5 m)X 2 5.5 (Charged for 5 m)X 2
54/56
61/63
60/62 (*5)
61/63 (*5)
60/62
1,345X 900X 320
1,440X 1,280X 690
(1,220X 1,280X 690)X 2 (1,440X 1,280X 690)X 2
1,220X 1,280X 690
112
206
180X 2
206X 2
180
-5 to 46
0 to 50
0 to 50
-10 to 15
-10 to 15
9.5 (Flare)
12.7 (Flare)
15.9 (Flare)
12.7X 2 (Flare)
15.9X 2 (Flare)
25.4 (Flange)
28.6 (Flange)
25.4X 2 (Flange)
28.6X 2 (Flange)
19.1 (Flare)
PT3/4 (Internal thread)
1B
26.0 (Hole)

50 (Equivalent length 70 m)
30
Both liquid and gas pipes
FDY06KAY1
RY140LUY1

kW
Btu/h
kcal/h
kW
Btu/h
kcal/h
kW
kW
m3/min
cfm
dBA
mm
kg
CWB
CDB
kW
kg
dBA
mm
kg
CDB
CWB
mm
mm
mm
m
m

Cooling only

Indoor unit
Outdoor unit

Model
Power Supply
Cooling capacity
(*1) (1)/(2)

Power consumption
Indoor
unit

(*1) (1)/(2)

Airflow rate (H)

Sound level (H)


Dimensions (HX WX D)
Weight
Operation range
Compressor
Outdoor
Motor output
unit
Refrigerant Charge (R22)
Sound level (*3)
Dimensions (HX WX D)
Weight
Operation range
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation
(*4)

Heat pump

Cooling capacity

LO W S TA TIC P R ES S U R E

(*1) (1)/(2)

FDYB

S IMULTANE OUS OPE R ATION S YS TE M

TRIPLE & DOUBLE TWIN MULTI

50Hz

Heat pump
Indoor unit
Outdoor unit

Model
Power Supply
Cooling capacity
(*1) (1)/(2)

Heating capacity
(*2)

Power
Cooling
consumption Heating
Indoor
unit

(*1) (1)/(2)
(*2)

Airflow rate (H/L)

Sound level (H)


Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Compressor
Outdoor
Motor output
unit
Refrigerant Charge (R22)
Sound level (Cooling/ Heating)(*3)
Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation
(*6)

kW
Btu/h
kcal/h
kW
Btu/h
kcal/h
kW
kW
m3/min
cfm
dBA
mm
kg
CWB
CDB
kW
kg
dBA
mm
kg
CDB
CWB
mm
mm
mm
mm
m
m

FDYB50KAVEX 4
FDYB71KAVEX 3
FDYB60KAVEX 4
RY200KUY1
RY200KUY1
RY250KUY1
Y1: 3 phase, 380-415 V, 50 Hz VE: 1 phase, 220-240 V/220 V, 50/60 Hz
22.5/22.2
22.5/22.2
27.1/26.6
76,800/75,800
76,800/75,800
92,500/90,800
19,400/19,100
19,400/19,100
23,300/22,900
22.7
22.7
28.4
77,500
77,500
97,000
19,500
19,500
24,400
7.7/7.6
7.7/7.6
9.7/9.7
6.5
6.5
9.2
13/11
18/15
18/15
460/388
635/529
635/529
41
43
43
260X 900X 580
260X 1,300X 580
260X 1,300X 580
23
31
31
14 to 25
14 to 25
14 to 25
15 to 27
15 to 27
15 to 27
Hermetically sealed scroll type
5.5
5.5
9.0
4.0 (Charged for 5 m)
5.5 (Charged for 5 m)
4.0 (Charged for 5 m)
60/62
60/62
61/63
1,220X 1,280X 690
1,220X 1,280X 690
1,440X 1,280X 690
180
206
180
0 to 50
-10 to 15
12.7 (Flare)
12.7 (Flare)
15.9 (Flare)
25.4 (Flange)
25.4 (Flange)
28.6 (Flange)
3/4B

50 (Equivalent length 70 m)
30
Both liquid and gas piping

Heating capacity
(*2)

Power
Cooling
consumption Heating

(*1) (1)/(2)
(*2)

Airflow rate (H)


Sound level
Dimensions (HX WX D)
Weight
(*4)
Cooling
Operation
range
Heating
Compressor
Outdoor
Motor output
unit
Refrigerant Charge (R22)
Sound level (Cooling/ Heating) (*3)
Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation
Indoor
unit

kW
Btu/h
kcal/h
kW
m3/min
cfm
dBA
mm
kg
CWB
kW
kg
dBA
mm
kg
CDB
mm
mm
mm
mm
m
m

Indoor unit
Outdoor unit

Model
Power Supply

S P ECIFICA TIO N S

FDYM

M IDDLE S TA TIC P R ES S U R E

kW
Btu/h
kcal/h
kW
Btu/h
kcal/h
kW
kW
m3/min
cfm
dBA
mm
kg
CWB
CDB
kW
kg
dBA
mm
kg
CDB
CWB
mm
mm
mm
mm
m
m

S IMULTANE OUS OPE R ATION S YS TE M

TWIN & TRIPLE MULTI

50Hz

FDYM04FAV1 2
FDYM05FAV1 2
FDYM03FAV1 3
R200KUY1
R250KUY1
R200KUY1
V1: 1 phase, 220-240 V, 50 Hz Y1: 3 phase, 380-415 V, 50 Hz
22.5/22.2
27.1/26.6
22.5/22.2
92,500/90,800
76,800/75,800
76,800/75,800
23,300/22,900
19,400/19,100
19,400/19,100
7.7/7.6/9.3
9.9/9.9/12.0
8.0/7.9/9.6
26
35
20
917
1,235
706
39
44
39
295X 1,500X 680
295X 1,100X 680
56
57
42
14 to 25
Hermetically sealed scroll type
5.5
9.0
5.5
5.3 (Charged for 5 m)
5.7 (Charged for 5 m)
5.3 (Charged for 5 m)
60
60
61
1,220X 1,280X 690
1,440X 1,280X 690
1,220X 1,280X 690
178
202
178
-5 to 52
12.7 (Flare)
15.9 (Flare)
12.7 (Flare)
25.4 (Flange)
28.6 (Flange)
25.4 (Flange)
VP25 ( 25I.D. , 32O.D. )

50 (Equivalent length 70 m)
30
Both liquid and gas piping

FDYM04FAV1 2
FDYM05FAV1 2
FDYM03FAV1 3
RY200KUY1
RY250KUY1
RY200KUY1
V1: 1 phase, 220-240 V, 50 Hz Y1: 3 phase, 380-415 V, 50 Hz
22.5/22.2
22.5/22.2
27.1/26.6
76,800/75,800
92,500/90,800
76,800/75,800
19,400/19,100
23,300/22,900
19,400/19,100
22.7
28.4
22.7
77,500
97,000
77,500
19,500
24,400
19,500
7.7/7.6
9.9/9.9
8.0/7.9
6.5
9.4
6.8
26
35
20
917
1,235
706
39
44
39
295X 1,500X 680
295X 1,100X 680
56
57
42
14 to 25
15 to 27
Hermetically sealed scroll type
5.5
9.0
5.5
4.0 (Charged for 5 m)
5.5 (Charged for 5 m)
4.0 (Charged for 5 m)
60/62
61/63
60/62
1,220X 1,280X 690
1,440X 1,280X 690
1,220X 1,280X 690
180
180
206
0 to 50
-10 to 15
12.7 (Flare)
15.9 (Flare)
12.7 (Flare)
25.4 (Flange)
28.6 (Flange)
25.4 (Flange)
VP25 ( 25I.D. , 32O.D. )

50 (Equivalent length 70 m)
30
Both liquid and gas piping

Notes: (*1). Cooling capacities are based on the following conditions:


(1) Suction temperature: 27CDB, 19.5CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Suction temperature: 27CDB, 19.0CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(*2). Heating capacities are based on the following conditions:
Suction temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)
(*3). Sound level is anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
(*4). Each value shows the specification per one unit.
The above performance data based on the power supply of 220 V (380 V).
The power consumption shown above is that of the outdoor unit only. The power consumption of the indoor unit varies according to setup conditions, so refer to the engineering data to
obtain the relevant figure.

Notes: (*1). Cooling capacities are based on the following conditions:


(1) Suction temperature: 27CDB, 19.5CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Suction temperature: 27CDB, 19.0CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(*2). Heating capacities are based on the following conditions:
Suction temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)
(*3). Sound level is anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
(*4). Without control box
(*5). The specification of the outdoor unit shows only one unit.
(*6). Each value shows the specification per one unit.
(*7). Cooling capacities are gross, not including a deduction for cooling for indoor fan motor heat.
(*8). Heating capacities are net, including an addition for heating for indoor fan motor heat.
The above performance data based on the power supply of 220 V (380 V).
The power consumption shown above is that of the outdoor unit only. The power consumption of the indoor unit varies according to setup conditions, so refer to the engineering data to
obtain the relevant figure.

17

18

S P ECIFICA TIO N S ......For high outdoor temperature use


LO W S TA TIC P R ES S U R E
Cooling only

Indoor unit
Outdoor unit

Model
Power Supply

kW
Btu/h
kcal/h
kW
m3/min
cfm

Cooling capacity
(*1) (1)/(2)

Power consumption
Indoor
unit

FD ( Y ) B

(*1) (1)/(2)

Airflow rate (H/L)

Fan
Driving system
Sound level (H/L)
dBA
Dimensions (HX WX D)
mm
Weight
kg
Operation range
CWB
Compressor
Outdoor
Motor output
kW
unit
Refrigerant Charge (R22)
kg
Sound level (*3)
dBA
Dimensions (HX WX D)
mm
Weight
kg
Operation range
CDB
Liquid
mm
Piping
Gas
mm
connections
Indoor unit
Drain
Outdoor unit
mm
Max. piping length
m
Max. Installation level difference
m
Heat insulation

Indoor unit
Outdoor unit

Model
Power Supply
Cooling capacity
(*1) (1)/(2)

Heating capacity
(*2) (1)/(2)

Indoor
unit

60Hz
FDB50KVE
FDB60KVE
FDB71KVE
R50GVAL
R60GVAL
R71FUVAL
VE: 1 phase, 220-240 V/220 V, 50/60 Hz VAL: 1 phase, 220 V, 60 Hz
5.60/5.00
6.50/5.6
8.10/6.70
19,100/17,100
22,200/19,100
27,800/22,900
4,820/4,300
5,590/4,800
7,000/5,800
2.10/2.41
2.70/3.29
3.30/3.78
13/11
17/14
460/388
600/494
Direct drive (2 speed)
41/ 38
42/ 39
260X 900X 580
260X 1,300X 580
260X 1,300X 580
23
31
14 to 23
14 to 25
Hermetically sealed rotary type
Hermetically sealed type
1.5
1.8
2.2
1.15 (Charged for 10 m)
1.60 (Charged for 5 m)
2.2 (Charged for 5 m)
52
55
53
540X 750X 270
685X 800X 300
816X 880X 370
41
51
87
19.4 to 54
21 to 54
6.4 (Flare)
9.5 (Flare)
15.9 (Flare)
3/4B
18.0 (Hole)
26.0 (Hole)
30
50 (Equivalent length 70 m)
15
30
Both liquid and gas pipes

(*1) (1)/(2)
(*2) (1)/(2)

Airflow rate (H/L)

Fan
Driving system
Sound level (H/L)
Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Compressor
Outdoor
Motor output
unit
Refrigerant Charge (R22)
Sound level (Cooling/ Heating) (*3)
Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation

kW
Btu/h
kcal/h
kW
Btu/h
kcal/h
kW
kW
m3/min
cfm
dBA
mm
kg
CWB
CDB
kW
kg
dBA
mm
kg
CDB
CWB
mm
mm
mm
m
m

FDYB50KAVE
FDYB60KAVE
FDYB71KAVE
RY50GVAL
RY60GVAL
RY71FUVAL
VE: 1 phase, 220-240 V/220 V, 50/60 Hz VAL: 1 phase, 220 V, 60 Hz
5.80/5.11
6.40/5.71
8.10/7.2
19,800/17,400
21,800/19,500
27,800/24,600
4,990/4,390
5,500/4,910
7,000/6,200
6.30/6.25
7.19/7.13
9.0/9.0
21,500/21,300
24,500/24,400
30,600/30,600
5,420/5,370
6,180/6,140
7,700/7,700
2.20/2.48
2.70/3.29
3.50/4.05
2.00/2.02
2.44/2.47
3.30/3.32
13/11
17/14
460/388
600/494
Direct drive (2 speed)
41/ 38
42/ 39
260X 900X 580
260X 1,300X 580
260X 1,300X 580
23
31
14 to 23
14 to 25
14 to 28
15 to 24
Hermetically sealed rotary type
Hermetically sealed type
1.5
1.8
2.2
1.45 (Charged for 10 m)
1.75 (Charged for 5 m)
2.3 (Charged for 5 m)
51/51
53/51
53/55
685X 800X 300
685X 880X 350
816X 880X 370
50
62
91
19.4 to 54
-5 to 54
-10 to 15
-10 to 15.5
6.4 (Flare)
9.5 (Flare)
15.9 (Flare)
3/4B
18.0 (Hole)
26.0 (Hole)
30
50 (Equivalent length 70 m)
15
30
Both liquid and gas pipes

Notes: (*1). Cooling capacities are based on the following conditions:


(1) Suction temperature: 27CDB, 19.0CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Suction temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal)(SSA385/386)
(*2). Heating capacities are based on the following conditions:
(1) Suction temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m(Horizontal)
(2) Suction temperature: 21CDB,Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 7.5 m (Horizontal)(SSA385/386)
(*3). Sound level is anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
In case of drain piping for outdoor unit, drain piping kit (option) is needed (R(Y)50, 60G).
The above performance data based on the power supply of 220 V (380 V).
The power consumption shown above is that of the outdoor unit only. The power consumption of the indoor unit varies according to setup conditions, so refer to the engineering data to
obtain the relevant figure.

19

FD ( Y ) M

M IDDLE S TA TIC P R ES S U R E
Cooling only

Indoor unit
Outdoor unit

Model
Power Supply
Cooling capacity
(*1) (1)/(2)

Power consumption
Indoor
unit

(*1) (1)/(2)

Airflow rate (H)

Sound level (H)


Dimensions (HX WX D)
Weight
Operation range
Compressor
Outdoor
Motor output
unit
Refrigerant Charge (R22)
Sound level (*3)
Dimensions (HX WX D)
Weight
Operation range
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation

Cooling only

Heat pump

Cooling
Power
consumption Heating

S P ECIFICA TIO N S ......For high outdoor temperature use

Model
Power Supply
Cooling capacity
(*1) (2)/(3)

Power consumption (*1) (2)/(3)


Colour
Indoor
unit
Airflow rate (H)

kW
Btu/h
kcal/h
kW
m3/min
cfm
dBA
mm
kg
CWB
kW
kg
dBA
mm
kg
CDB
mm
mm
mm
mm
m
m

Indoor unit
Outdoor unit
kW
Btu/h
kcal/h
kW
m3/min
cfm

Driving system
Fan
Sound level (H) (*3)
dBA
Dimensions (HX WX D)
mm
Weight
kg
Operation range
CWB
Colour
Outdoor
Compressor Type
unit
Motor output
kW
Refrigerant Charge (R22)
kg
Sound level (*3)
dBA
Dimensions (HX WX D)
mm
Weight
kg
Operation range
CDB
Liquid
mm
Piping
Gas
mm
connections
Indoor unit
mm
Drain
Outdoor unit
mm
Max. piping length
m
Max. Installation level difference
m
Heat insulation

60Hz

FDYM03FAVAL
FDYM04FAVAL
FDYM05FAVAL
FDYM06FAVAL
R71LUVAL
R100LUVAL
R125LUTALYAL
R140LUTALYAL
VAL: 1 phase, 220 V, 60 Hz TAL: 3 phase, 220 V, 60 Hz YAL: 3 phase, 380 V, 60 Hz
8.3/ 8.1
11.6/ 11.4
14.5/14.3
16.1/15.8
28,200/ 27,800
39,700/ 38,900
49,600/ 48,800
55,000/ 53,900
7,100/ 7,000
10,000/ 9,800
12,500/ 12,300
13,800/13,500
3.41/3.41
4.38/4.38
TAL5.76/ 5.76, YAL5.78/5.78 TAL5.74/ 5.74, YAL5.72/5.72
22
28
38
40
1,341
1,412
776
988
42
47
49
295X 1,500X 680
295X 1,100X 680
57
42
56
14 to 25
Hermetically sealed scroll type
2.24
2.92
3.75
4.5
3.7 (Charged for 30 m)
4.1 (Charged for 30 m)
2.8 (Charged for 30 m)
3.7 (Charged for 30 m)
51
51
55
49
1,345X 900X 320
770X 900X 320
1,170X 900X 320
1,170X 900X 320
98
109
75
92
21 to 46, -15 to 46 (Option installed)(*4)
9.5 (Flare)
19.1 (Flare)
15.9 (Flare)
VP25 ( 25I.D. , 32O.D. )
26.0 (Hole)
50 (Equivalent length 70 m)
30
Both liquid and gas piping

FDM03FAVAL
FDM04FAVAL
FDM05FAVAL
FDYM06FAVAL
R71FUVAL
R100FUVAL
R125FUTAL
R140KUTALK
VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
8.1/6.7
11.4/9.0
14.3/12.5
15.8/14.0
27,800/22,900
38,900/30,700
48,800/42,700
53,900/47,800
7,000/5,800
9,800/7,700
12,300/10,800
13,500/12,000
3.44/3.92
4.61/5.27
6.25/7.10
5.80/7.00
22
776
295X 1,100X 680
42

2.2
2.2 (Charged for 5 m)
53
816X 880X 370
87
15.9 (Flare)

28
988
42
56
14 to 25

38
1,341

40
1,412

47
295X 1,500X 680

49

Direct drive (2 speed)

Ivory

Hermetically sealed type


3.0
3.75
2.9 (Charged for 5 m)
3.1 (Charged for 5 m)
57
59
1,215X 880X 370
1,215X 880X 370
117
110
21 to 54
9.5 (Flare)
19.1 (Flare)
VP25 ( 25I.D. , 32O.D.)
26.0 (Hole)
50 (Equivalent length 70 m)
30
Both liquid and gas piping

57

12 to 25

Hermetically sealed scroll type


4.5
2.7 (Charged for 5 m)
56
1,345X 880X 370
109

Notes: (*1). Cooling capacities are based on the following conditions:


(1) Suction temperature: 27CDB, 19.5CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Suction temperature: 27CDB, 19.0CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal).(R71LU-R140LU is 7.5 m)
(3) Suction temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal)(SSA385/386)
(*2). Heating capacities are based on the following conditions:
Suction temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)
(*3). Sound level is anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values are normally somewhat higher as a result of ambient
conditions.
(*4). This value is for when year-round cooling kit (option) is installed.
The above performance data based on the power supply of 220 V (380 V).
The power consumption shown above is that of the outdoor unit only. The power consumption of the indoor unit varies according to setup conditions, so refer to the engineering data to
obtain the relevant figure.

20

S P ECIFICA TIO N S ......For high outdoor temperature use


FD ( Y ) M

M IDDLE S TA TIC P R ES S U R E
Indoor unit
Outdoor unit

Model
Power Supply
Cooling capacity
(*1) (1)/(2)

Heating capacity
(*2) (1)/(2)

Indoor
unit

60Hz

(*1) (1)/(2)
(*2) (1)/(2)

Airflow rate (H)

Sound level
Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Compressor
Outdoor
Motor output
unit
Refrigerant Charge (R22)
Sound level (Cooling/ Heating) (*3)
Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation

kW
Btu/h
kcal/h
kW
Btu/h
kcal/h
kW
kW
m3/min
cfm
dBA
mm
kg
CWB
CDB
kW
kg
dBA
mm
kg
CDB
CWB
mm
mm
mm
mm
m
m

FDYM05FAVAL
FDYM06FAVAL
FDYM06FAVAL
FDYM03FAVAL
FDYM04FAVAL
RY71FUVAL
RY100FUVAL
RY125FUTAL
RY140LUTALYAL
RY140KUTALK
VAL: 1 phase, 220 V, 60 Hz TAL: 3 phase, 220 V, 60 Hz YAL: 3 phase, 380 V, 60 Hz
8.1/6.7
14.3/12.5
15.8/ 16.1 (*4)
15.8/14.0
11.4/9.0
27,800/22,900
48,800/42,700
53,900/ 55,000 (*4)
53,900/47,800
38,900/30,700
7,000/5,800
12,300/10,800
13,500/ 13,800 (*4)
13,500/12,000
9,800/7,700
9.0/8.5
12.8/11.8
16.2/15.0
18.1/
18.1/17.0
30,600/29,000
43,700/40,300
55,200/51,200
61,900/
61,900/58,00
7,700/7,300
11,000/10,100
13,900/12,900
15,600/
15,600/14,600
3.82/4.37
4.76/5.25
6.05/6.71
TAL5.66/5.66 (*4), YAL5.64/5.64 (*4)
5.8/7.0
3.57/3.59
4.49/4.51
5.56/5.60
TAL5.72/, YAL5.70/
5.8/5.9
22
28
38
40
40
776
988
1341
1412
1412
42
47
49
49
295X 1,100X 680
295X 1,500X 680
42
56
57
14 to 25
12 to 25
12 to 25
15 to 24
15 to 27
15 to 27
Hermetically sealed type
Hermetically sealed scroll type Hermetically sealed scroll type
2.2
3.0
3.75
4.5
4.5
2.3 (Charged for 5 m) 2.6 (Charged for 5 m) 3.1 (Charged for 5 m) 4.1 (Charged for 30 m) 2.7 (Charged for 5 m)
53/55
59/61
55/57
56/58
57/59
816X 880X 370
1,345X 900X 320
1,345X 880X 370
1,215X 880X 370
91
115
112
112
120
-5 to 54
-5 to 46
-5 to 54
-10 to 15.5
-10 to 15
-10 to 15
9.5 (Flare)
15.9 (Flare)
19.1 (Flare)
VP25 ( 25I.D. , 32O.D. )
26.0 (Hole)
50 (Equivalent length 70 m)
30
Both liquid and gas piping

Notes: (*1). Cooling capacities are based on the following conditions:


(1) Suction temperature: 27CDB, 19.0CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal).(RY140LU is 7.5 m)
(2) Suction temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal)(SSA385/386)
(*2). Heating capacities are based on the following conditions:
(1) Suction temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal).(RY140LU is 7.5 m)
(2) Suction temperature:21CDB,Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
(*3). Sound level is anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
(*4). Value is not based on the conditions of (*1)(2), but on the following conditions: Return air temperature: 27CDB, 19.5CWB, Outdoor temperature: 35CDB Equivalent ref. piping:
5 m (Horizontal)
The above performance data based on the power supply of 220 V (380 V).
The power consumption shown above is that of the outdoor unit only. The power consumption of the indoor unit varies according to setup conditions, so refer to the engineering data to obtain the relevant figure.
In case of drain piping for outdoor unit (RY140KUTALK , YALK). Central drain plug (option) is needed.

H IG H S TA TIC P R ES S U R E
Cooling only
Power Supply
Cooling capacity
(*1) (1)/(2) (*4)

Power consumption

FD ( Y )

Indoor unit
Outdoor unit

Model

(*1) (1)/(2)

Airflow rate (H)

60Hz
FD03KVAL
R71FUVAL

kW
Btu/h
kcal/h
kW
m3/min
cfm

Fan
Driving system
Sound level
dBA
Dimensions (HX WX D)
mm
Weight
kg
Operation range
CWB
Compressor
Outdoor
Motor output
kW
unit
Refrigerant Charge (R22)
kg
Sound level (*3)
Dimensions (HX WX D)
Weight
Operation range
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation

Power Supply
(*1) (1)/(2) (*6)

Indoor
unit

dBA
mm
kg
CDB
mm
mm
mm
m
m

8.5/7.1
29,000/24,200
7,300/6,100
3.22/3.70
26
917
46
450X 650X 850
54
3.4
2.2
(Charged for 5 m)
53
816X 880X 370
87
15.9 (Flare)

FD04KVAL
FD05KTAL
FD06KTAL
R100FUVAL
R125FUTAL
RU06KTAL
VAL: 1 phase, 220 V, 60 Hz TAL: 3 phase, 220 V, 60 Hz
11.9/9.0
15.2/14.1
17.3/15.7
40,600/30,700
52,000/48,100
59,100/53,600
10,200/7,700
13,100/12,100
14,900/13,500
4.37/5.02
5.88/6.73
6.5/7.9
30
46
52
1,059
1,623
1,835
Belt drive
49
51
450X 900X 850
450X 1,130X 850
62
72
79
14 to 25
Hermetically sealed reciplocating type
Hermetically sealed scroll type
4.5
6.0
4.5
2.9
3.1
3.0
(Charged for 5 m)
(Charged for 5 m)
(Charged for 5 m)
57
59
1,215X 880X 370
1,345X 880X 320
117
110
112
21 to 54
21 to 50
9.5 (Flare)
19.1 (Flare)
3/4B
26.0 (Hole)

50 (Equivalent length 70 m)
30
Both liquid and gas pipes

(*1) (1)/(2)

Airflow rate

Fan
Driving system
Sound level
dBA
Dimensions (HX WX D)
mm
Weight
kg
Operation range
CWB
Compressor
Outdoor
Motor output
kW
unit
Refrigerant Charge (R22)
kg
Sound level (*3)
Dimensions (HX WX D)
Weight
Operation range
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation

Cooling only
Power Supply
Cooling capacity
(*1) (1)/(2) (*6)

Power consumption

dBA
mm
kg
CDB
mm
mm

(*1) (1)/(2)

Airflow rate

51
500X 1,130X 850
93
5.5
5.0
(Charged for 5 m)
60
1,220X 1,280X 690
185
12.7 (Flare)
25.4 (Brazing)

3/4B

FD10KTAL
FD15KTAL
RU10KUTAL
RU08KUTAL 2
TAL: 3 phase, 220 V, 60 Hz
29.2/26.7
47.9/43.8
99,600/91,300
163,500/149,500
25,100/23,000
41,200/37,700
10.3/12.6
16.6/20.2
83
136
4,800
2,930
Belt drive
53
58
625X 1,620X 850
500X 1,330X 850
104
161
14 to 25
Hermetically sealed scroll type
7.5
5.5X 2
6.1
5.0
(Charged for 5 m)
(Charged for 5 m)X 2
61
60 (*4)
1,440X 1,280X 690
(1,220X 1,280X 690)X 2
185X 2
200
21 to 50
15.9 (Flare)
12.7X 2 (Flare)
31.8 (Brazing)
25.4X 2 (Brazing)

50 (Equivalent length 70 m)
30
Both liquid and gas pipes

FD20KTAL
RU10KUTAL 2
58.4/53.3
199,400/182,000
50,200/45,800
20.6/25.3
166
5,860
60
625X 1,980X 850
187
7.5X 2
6.1
(Charged for 5 m)X 2
61 (*4)
(1,440X 1,280X 690)X 2
200X 2

1B

15.9X 2 (Flare)
31.8X 2 (Brazing)

FD08KTAL
RU08KTAL

kW
Btu/h
kcal/h
kW
m3/min
cfm

Fan
Driving system
Sound level
dBA
Dimensions (HX WX D)
mm
Weight
kg
Operation range
CWB
Compressor
Outdoor
Motor output
kW
unit
Refrigerant Charge (R22)
kg
Sound level (*3)
Dimensions (HX WX D)
Weight
Operation range
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation

24.0/21.9
81,800/74,600
20,600/18,800
8.3/10.1
68
2,400

mm
m
m

Indoor unit
Outdoor unit

Model

60Hz
FD08KTAL
RU08KUTAL

kW
Btu/h
kcal/h
kW
m3/min
cfm

Cooling capacity
Power consumption

FD ( Y )

Indoor unit
Outdoor unit

Model

Indoor
unit

S P ECIFICA TIO N S

Indoor
unit

H IG H S TA TIC P R ES S U R E
Cooling only

Heat pump

Power
Cooling
consumption Heating

S P ECIFICA TIO N S ......For high outdoor temperature use

dBA
mm
kg
CDB
mm
mm
mm
m
m

FD10KTAL
FD15KTAL
FD20KTAL
RU10KTAL
RU08KTAL 2
RU10KTAL 2
TAL: 3 phase, 220 V, 60 Hz
24.0/21.9
29.2/26.7
47.9/43.8
58.4/53.3
81,800/74,600
99,600/91,300
163,500/149,500
199,400/182,000
20,600/18,800
25,100/23,000
41,200/37,700
50,200/45,800
20.6/25.3
8.3/10.1
10.3/12.6
16.6/20.2
68
83
136
166
4,800
5,860
2,400
2,930
Belt drive
51
53
58
60
625X 1,620X 850
625X 1,980X 850
500X 1,130X 850
500X 1,330X 850
93
104
161
187
14 to 25
Hermetically sealed scroll type
5.5
7.5
5.5X 2
7.5X 2
5.0
6.1
5.0
6.1
(Field charge required for 5 m)(*5) (Field charge required for 5 m)(*5) (Field charge required for 5 m)(*5)X 2 (Field charge required for 5 m)(*5)X 2
60
61
60 (*4)
61 (*4)
1,220X 1,280X 690
1,440X 1,280X 690
(1,220X 1,280X 690)X 2
(1,440X 1,280X 690)X 2
176X 2
188X 2
176
188
21 to 50
12.7 (Brazing)
15.9 (Brazing)
12.7X 2 (Brazing)
15.9X 2 (Brazing)
25.4 (Brazing)
31.8 (Brazing)
25.4X 2 (Brazing)
31.8X 2 (Brazing)
3/4B
1B

50 (Equivalent length 70 m)
30
Both liquid and gas pipes

Notes: (*1). Cooling capacities are based on the following conditions:


(1) Suction temperature: 27CDB, 19.0CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Suction temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal)(SSA385/386)
(*3). Sound level is anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
(*4). The specification of the outdoor unit shows only one unit.
(*5). This is the amount of refrigerant required for piping of five metres or less. Since the unit does not contain refrigerant when shipped from the factory, it must be added at the
installation site. For details, please refer to the installation manual.
(*6). Capacities show gross capacities which do not include a deduction for evaporator fan motor heat.
The above performance data based on the power supply of 220 V.
The power consumption shown above is that of the outdoor unit only. The power consumption of the indoor unit varies according to setup conditions, so refer to the engineering data to
obtain the relevant figure.

Notes: (*1). Cooling capacities are based on the following conditions:


(1) Suction temperature: 27CDB, 19.0CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Suction temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal)(SSA385/386)
(*3). Sound level is anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
(*4). Capacities show gross capacities which do not include a deduction for evaporator fan motor heat.
The power consumption shown above is that of the outdoor unit only. The power consumption of the indoor unit varies according to setup conditions, so refer to the engineering data to obtain the relevant figure.

21

22

S P ECIFICA TIO N S ......For high outdoor temperature use

S P ECIFICA TIO N S ......For high outdoor temperature use

FD ( Y )

H IG H S TA TIC P R ES S U R E

60Hz

Heat pump
Indoor unit
Outdoor unit

Model
Power Supply
Cooling capacity
(*1) (1)/(2) (*7)

Heating capacity
(*2) (1)/(2) (*8)

Power
Cooling
consumption Heating
Indoor
unit

(*1) (1)/(2)
(*2) (1)/(2)

Airflow rate

Driving system
Fan
Sound level
Dimensions (HX WX D) (*4)
Weight
Cooling
Operation
range
Heating
Compressor
Outdoor
Motor output
unit
Refrigerant Charge (R22)
Sound level (Cooling/ Heating) (*3)
Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation

FDY15KATALYAL
FDY10KATALYAL
FDY20KATALYAL
RY250KUTALYAL
RY200KUTALYAL 2
RY250KUTALYAL 2
TAL: 3 phase, 220 V, 60 Hz YAL: 3 phase, 380 V, 60 Hz
22.2/19.8
43.5/38.7
53.0/47.3
27.1/24.3
75,700/67,600
148,000/132,000
181,000/161,000
92,500/82,900
19,100/17,000
37,400/33,300
45,600/40,700
23,300/20,900
23.2/22.9
29.5/29.1
44.8/44.6
56.8/56.6
79,200/78,100
100,700/99,300
153,000/152,000
194,000/193,000
20,000/19,700
25,400/25,000
38,500/38,400
48,800/48,700
7.7/9.4
9.7/11.9
15.3/18.8
19.4/23.8
6.6/6.7
9.3/9.5
13.2/13.4
18.6/19.0
68
83
136
166
2,400
2,930
4,800
5,860
Belt drive
51
53
58
60
500X 1,130X 850
500X 1,330X 850
625X 1,620X 850
625X 1,980X 850
94
105
161
187
14 to 25
14 to 25
15 to 27
15 to 27
Hermetically sealed scroll type
5.5
7.5
5.5X 2
7.5X 2
4.0 (Charged for 5 m)
4.0 (Charged for 5 m)X 2
5.5 (Charged for 5 m)X 2
5.5 (Charged for 5 m)
60/62
60/62 (*5)
61/63 (*5)
61/63
1,220X 1,280X 690
(1,220X 1,280X 690)X 2
(1,440X 1,280X 690)X 2
1,440X 1,280X 690
179
179X 2
204X 2
204
0 to 54
-10 to 15
12.7 (Flare)
15.9 (Flare)
12.7X 2 (Flare)
15.9X 2 (Flare)
25.4 (Flange)
28.6 (Flange)
25.4X 2 (Flange)
28.6X 2 (Flange)
3/4B
1B

50 (Equivalent length 70 m)
30
Both liquid and gas pipes

FDY08KATALYAL
RY200KUTALYAL

kW
Btu/h
kcal/h
kW
Btu/h
kcal/h
kW
kW
m3/min
cfm
dBA
mm
kg
CWB
CDB
kW
kg
dBA
mm
kg
CDB
CWB
mm
mm
mm
m
m

Cooling only

Indoor unit
Outdoor unit

Model
Power Supply
Cooling capacity
(*1) (1)/(2)

Power consumption
Indoor
unit

(*1) (1)/(2)

Airflow rate (H)

Sound level (H)


Dimensions (HX WX D)
Weight
Operation range
Compressor
Outdoor
Motor output
unit
Refrigerant Charge (R22)
Sound level (*3)
Dimensions (HX WX D)
Weight
Operation range
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation
(*4)

FDYB

S IMULTANE OUS OPE R ATION S YS TE M

TRIPLE & DOUBLE TWIN MULTI

60Hz

Heat pump
Indoor unit

Model

Outdoor unit

Power Supply
Cooling capacity
(*1) (1)/(2)

Heating capacity
(*2) (1)/(2)

Cooling
Power
consumption Heating
Indoor
unit

(*1) (1)/(2)
(*2) (1)/(2)

Airflow rate (H/L)

Sound level
Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Compressor
Outdoor
Motor output
unit
Refrigerant Charge (R22)
Sound level (Cooling/ Heating) (*3)
Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation
(*6)

kW
Btu/h
kcal/h
kW
Btu/h
kcal/h
kW
kW
m3/min
cfm
dBA
mm
kg
CWB
CDB
kW
kg
dBA
mm
kg
CDB
CWB
mm
mm
mm
mm
m
m

FDYB50KAVEX 4
FDYB71KAVEX 3
FDYB60KAVEX 4
RY200KUTAL
RY200KUTAL
RY250KUTAL
RY200KUYAL
RY200KUYAL
RY250KUYAL
TAL: 3 phase, 220 V, 60 Hz YAL: 3 phase, 380 V, 60 Hz VE: 1 phase, 220-240 V/220 V, 50/60 Hz
22.2/20.0
22.2/20.0
26.6/24.1
75,800/68,300
75,800/68,300
90,800/82,300
19,100/17,200
19,100/17,200
22,900/20,700
22.7/22.4
22.7/22.4
28.4/28.0
77,500/76,500
77,500/76,500
97,000/95,600
19,500/19,300
19,500/19,300
24,400/24,100
8.2/10.0
8.2/10.0
10.2/12.6
7.0/7.1
9.7/10.0
7.0/7.1
13/11
17/14
17/14
460/388
600/494
600/494
41
42
42
260X 900X 580
260X 1,300X 580
260X 1,300X 580
23
31
31
14 to 25
14 to 25
14 to 25
15 to 27
15 to 27
15 to 27
Hermetically sealed scroll type
5.5
5.5
7.5
4.0 (Charged for 5 m)
4.0 (Charged for 5 m)
5.5 (Charged for 5 m)
60/62
60/62
61/63
1,220X 1,280X 690
1,220X 1,280X 690
1,440X 1,280X 690
179
204
179
0 to 54
-10 to 15
12.7 (Flare)
12.7 (Flare)
15.9 (Flare)
25.4 (Flange)
25.4 (Flange)
28.6 (Flange)
3/4B

50 (Equivalent length 70 m)
30
Both liquid and gas piping

Notes: (*1). Cooling capacities are based on the following conditions:


(1) Suction temperature: 27CDB, 19.0CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Suction temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal)(SSA385/386)
(*2). Heating capacities are based on the following conditions:
(1) Suction temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Suction temperature: 21CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 7.5 m (Horizontal)(SSA385/386)
(*3). Sound level is anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
(*4). Without control box
(*5). The specification of the outdoor unit shows only one unit.
(*6). Each value shows the specification per unit.
(*7). Cooling capacities are gross, not including a deduction for cooling for indoor fan motor heat.
(*8). Heating capacities are net, including an addition for heating for indoor fan motor heat.
The above performance data based on the power supply of 220 V (380 V).
The power consumption shown above is that of the outdoor unit only. The power consumption of the indoor unit varies according to setup conditions, so refer to the engineering data to
obtain the relevant figure.

23

kW
Btu/h
kcal/h
kW
m3/min
cfm
dBA
mm
kg
CWB
kW
kg
dBA
mm
kg
CDB
mm
mm
mm
mm
m
m

S IMULTANE OUS OPE R ATION S YS TE M

TWIN & TRIPLE MULTI

60Hz

FDYM04FAVAL 2
FDYM05FAVAL 2
FDYM03FAVAL 3
R200KUTALYAL
R250KUTALYAL
R200KUTALYAL
VAL: 1 phase, 220 V, 60 Hz TAL: 3 phase, 220 V, 60 Hz YAL: 3 phase, 380 V, 60 Hz
22.2/20.0
26.6/24.1
22.2/20.0
90,800/82,300
75,800/68,300
75,800/68,300
22,900/20,700
19,100/17,200
19,100/17,200
8.2/10.0
10.4/12.7
8.5/10.3
28
38
22
988
1,341
776
42
47
42
295X 1,500X 680
295X 1,100X 680
56
57
42
14 to 25
Hermetically sealed scroll type
5.5
7.5
5.5
5.3 (Charged for 5 m)
5.7 (Charged for 5 m)
5.3 (Charged for 5 m)
60
61
60
1,220X 1,280X 690
1,440X 1,280X 690
1,220X 1,280X 690
177
200
177
-5 to 54
12.7 (Flare)
15.9 (Flare)
12.7 (Flare)
25.4 (Flange)
28.6 (Flange)
25.4 (Flange)
VP25 ( 25I.D. , 32O.D. )

50 (Equivalent length 70 m)
30
Both liquid and gas pipes

Heat pump
Indoor unit
Outdoor unit

Model
Power Supply

LO W S TA TIC P R ES S U R E

FDYM

M IDDLE S TA TIC P R ES S U R E

Cooling capacity
(*1) (1)/(2)

Heating capacity
(*2) (1)/(2)

Cooling
Power
consumption Heating
Indoor
unit

(*1) (1)/(2)
(*2) (1)/(2)

Airflow rate (H)

Sound level (H)


Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Compressor
Outdoor
Motor output
unit
Refrigerant Charge (R22)
Sound level (Cooling/ Heating) (*3)
Dimensions (HX WX D)
Weight
Cooling
Operation
range
Heating
Liquid
Piping
Gas
connections
Indoor unit
Drain
Outdoor unit
Max. piping length
Max. Installation level difference
Heat insulation
(*4)

kW
Btu/h
kcal/h
kW
Btu/h
kcal/h
kW
kW
m3/min
cfm
dBA
mm
kg
CWB
CDB
kW
kg
dBA
mm
kg
CDB
CWB
mm
mm
mm
mm
m
m

FDYM03FAVAL 3
FDYM04FAVAL 2
FDYM05FAVAL 2
RY200KUTALYAL
RY250KUTALYAL
RY200KUTALYAL
VAL: 1 phase, 220 V, 60 Hz TAL: 3 phase, 220 V, 60 Hz YAL: 3 phase, 380 V, 60 Hz
22.2/20.0
22.2/20.0
26.6/24.1
75,800/68,300
90,800/82,300
75,800/68,300
19,100/17,200
22,900/20,700
19,100/17,200
22.7/22.4
28.4/28.0
22.7/22.4
77,500/76,500
97,000/95,600
77,500/76,500
19,500/19,300
19,500/19,300
24,400/24,100
8.2/10.0
10.4/12.5
8.5/10.3
7.0/7.1
9.9/10.1
7.3/7.4
28
38
22
988
1,341
776
42
47
42
295X 1,500X 680
295X 1,100X 680
56
57
42
14 to 25
15 to 27
Hermetically sealed scroll type
5.5
7.5
5.5
4.0 (Charged for 5 m)
4.0 (Charged for 5 m)
5.5 (Charged for 5 m)
60/62
61/63
60/62
1,220X 1,280X 690
1,440X 1,280X 690
1,220X 1,280X 690
179
179
204
0 to 54
-10 to 15
12.7 (Flare)
15.9 (Flare)
12.7 (Flare)
25.4 (Flange)
28.6 (Flange)
25.4 (Flange)
VP25 ( 25I.D. , 32O.D. )

50 (Equivalent length 70 m)
30
Both liquid and gas pipes

Notes: (*1). Cooling capacities are based on the following conditions:


(1) Suction temperature: 27CDB, 19.0CWB Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Suction temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal)(SSA385/386)
(*2). Heating capacities are based on the following conditions:
(1) Suction temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Suction temperature: 21CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 7.5 m (Horizontal)(SSA385/386)
(*3). Sound level is anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
(*4). Each value shows the specification per one unit.
The above performance data based on the power supply of 220 V (380 V).
The power consumption shown above is that of the outdoor unit only. The power consumption of the indoor unit varies according to setup conditions, so refer to the engineering data to
obtain the relevant figure.

24

O P TIO N S
Control System

Outdoor Units

Many options are available for use with large-scale and advanced-function centrally controlled systems

O U TDO O R U N ITS fo r LO W S TA TIC P R ES S U R E

Central remote controller

Schedule timer

Unified ON/OFF controller

Wiring adaptor for


electrical appendices
KRP4A51,52,53

For connecting to a central monitoring


panel to enable discrete, group, and
zone control operations.

DCS302CA61

(*1)

Centralised control with function comparable to


remote controller for up to 1,024 indoor units.

DCS301BA61 (*1)

Centralised control of on/off by group or


all at once for up to 256 indoor units.

DST301BA61 (*1)

Unified control of weekly schedule for up


to 1,024 indoor units.

(*1) To use the above optional remote controllers, the adaptors shown on the right are required on the main unit side of the air conditioner.
(*2) The central control adaptor kit for FDB series can be made to order.

Wired remote controller with weekly schedule timer (Optional)


Adds new, advanced functions to those of the above wired remote controller.
24-hour clock function (1-hour backup for power failures)
Programming function for each day of week.
Scheduling possible of start/stop and temperature limit (5 settings/day)
Programming can be enabled or disabled.
Copy function for programmed schedules.

BRC1D61

Central control
adaptor kit (*2)
DTA107A55 (for FD series)

Interface adaptor
for SkyAir series
DTA102A52

(for FDYB, FDYM, FDY series)

Notes: 1. Standard remote controllers (BRC1C61) not required.


2. If the BRC1D61 is connected to the centralised remote controllers (DCS302CA61, DCS301BA61,
DST301BA61), the schedule function is not available.

For connecting to a centralised control


system that is made with the highspeed DIII-NET communication system
that has been adopted for the Daikin
VRV System.

FDB G / FDY B

Cooling only
Heat pump
FDB(G)25/35/50K
FDB(G)60K/FDB71K
FDYB35/50KAVE
FDYB60/71KAVE
KRC47-1A

BRC1C61

BRC1D61
KRC47-2A

KRC47-4A

BRC4C62

DCS302CA61(*1)

DCS301BA61(*1)

DST301BA61(*1)

KRP1B54

KRP4A52 (*2)

KRP1B100

DTA102A52
KDGF19A45
KDGF19A71
KDGF19A45
KDGF19A71
KKD19A1

Remote controller
LCD wired remote controler
Wired remote controller with weekly schedule timer
Digital remote controller
Digital remote controller for duct heater use
Wireless remote controller
Central remote controller
Unified ON/OFF controller
Schedule timer
Adaptor for wiring
Wiring adaptor for electrical appendices
Switch box for adaptor kit
Interface adaptor for SkyAir series
Suction grille
Drain pan cover

Remote controller
LCD wired remote controler
Wired remote controller with weekly schedule timer
Digital remote controller
Digital remote controller for duct heater use
Wireless remote controller
Central remote controller
Unified ON/OFF controller
Schedule timer
Adaptor for wiring
Wiring adaptor for electrical appendices
Switch box for adaptor kit
Interface adaptor for SkyAir series

FD ( Y )

Optional accessory
Remote controller
LCD wired remote controler
Wired remote controller with weekly schedule timer
Digital remote controller
Wireless remote controller
Central remote controller
Unified ON/OFF controller
Schedule timer
Remote sensor
Central control adaptor kit
Adaptor for wiring
Wiring adaptor for electrical appendices
Interface adaptor for SkyAir series
Installation box for adaptor PCB

25

O U TDO O R U N ITS fo r M IDDLE S TA TIC P R ES S U R E


Optional accessory
Central drain plug
Fixture for preventing overturning
Year-round cooling (For cooling only type)

R(Y)71LU

KRK5F80V1

FDY M / FDM G

Refrigerant branch
piping

For twin multi


For triple multi
For double twin multi

KRK5F140V1

Central drain plug

R(Y)200KU
KHD58C23A
KHR58P322H
KHRJ5F224F

FD ( Y )

R(Y)140LU(KU)

KKPJ5F180

Twin & Triple & Double twin multi


Optional accessory

Kit name

R(Y)100LU/R(Y)125LU(KU)

RG71A/R100FU/R125FU/
RG140A/RG180A

KPTJ60F160
KRK5F160V1

Kit name

R(Y)250KU
KHD58C24A

KHRJ5F280F

Kit name
R71FU/R100FU/R125FU/RY140LU
KKPJ5F180

FDM G / FDY M

Optional accessory

H IG H S TA TIC P R ES S U R E

KPW937A4
KKP937A4 (Note 1)

R71FU/RY71LU

KKPJ5F180

Note: 1. One set includes 5 pieces for 5 units.

Optional accessory

Kit name

Optional accessory

M IDDLE S TA TIC P R ES S U R E

Drain piping kit


Central drain plug
Air direction adjustment grille
Drain plug

Kit name
RY35F/R50G/RY50G/R60G/RY60G
KIS95

R25G/R35G

O U TDO O R U N ITS fo r H IG H S TA TIC P R ES S U R E

Indoor Units
LO W S TA TIC P R ES S U R E

Optional accessory

FD ( Y ) B

Notes: (*1). This optional accessory requires DTA102A52.


(*2). This optional accessory requires KRP1B100.
(*3). This optional accessory requires DTA107A55.

Kit name
Cooling only
FDMG71/100/125/140/180A
FD(Y)M03/04/05/06FA
KRC47-1

BRC1C61

BRC1D61
KRC47-2

KRC47-4

BRC4C64

DCS302C61 (*1)

DCS301B61 (*1)

DST301B61 (*1)

KRP4A51 (*5)

DTA102A52

Heat pump
FDYM03/04/05/06FA

BRC1C61
BRC1D61

BRC4C62
DCS302CA61(*1)
DCS301BA61(*1)
DST301BA61(*1)

KRP4A51 (*5)

DTA102A52

Kit name
Cooling only
FD03/04/05/06/08/10K
FD15, 20K
KRC47-3A/ KRC17-2B (*4)
KRC47-3A

KRC47-5

DCS302C61 (*3)
DCS301B61 (*3)
DST301B61 (*3)
KRCS01-1
DTA107A55

Heat pump
FDY06/08/10/15/20KA

BRC1C61
BRC1D61

BRC4C62
DCS302CA61 (*1)
DCS301BA61 (*1)
DST301BA61 (*1)

KRP1B57 (*2)
KRP4A53 (*2)
DTA102A52
KRP1B100

(*4). In case of using KRC17-2B or locally-obtained remote controller, Three-Minutes Timer (locally-obtained) is required.
(*5). Installation plate for adaptor PCB(KRP4A95) is necessary.

26