Machine room re

Date:

On Duty
Staff:

/2013

Inspection project name

23--30

Room temperature between 23 30 is normal, if higher or


lower than is fails, contact
relevant person to deal it.

3
4
5
6
7

10

11

12

13

14

Room humidity between 30-90%


30--90% is normal, if higher or lower than

is fails, please contact relevant


person to deal it.
Room hygiene, cleanliness

(Custom)
Whether leakage, seepage,

contact relevant person to deal

it.
Ceiling, floor for cracks (Custom)
(
Doors and windows are in good
)
condition (Custom)
Fire equipment panel lights

properly, beeps sound of failure.


UPS # 1 mains power indicator
UPS#1 lights green normal, off failure,

contact relevant person to deal


it immediately.
UPS # 1 normal load indicator
UPS#1 lights green, off failure, contact

relevant person to deal it


immediately.
UPS
# 2 mains indicator lights
UPS#2 green normal, off failure, contact

relevant person to deal it


immediately.
UPS # 2 normal load indicator
UPS#2 lights green, off failure, contact

relevant person to deal it


immediately.
UPS
# 3 mains indicator lights
UPS#3 green normal, off failure, contact

relevant person to deal it


immediately.
UPS # 3 normal load indicator
UPS#3 lights green, off failure, contact

relevant person to deal it


immediately.
Precision air-conditioning fault

light off normal, red fault, start


the standby machine to use, and
contact relevant person to deal
it.

0:00

High-frequency switching power


supply failure minor alarm lamp
lights orange, red notify the
relevant person to deal it.

16

(V)52V
56.3VA/B

High-frequency switching power


float voltage (V) at 52V to 56.3V
(A / B channel) is normal, higher
or lower than the set value fault,
contact relevant person to deal
it immediately.

17

High-frequency switching power


rectifier module bright green and
orange lights normally, red or
Quanmie lamp failure, contact
relevant person to deal it.

18

AB

15

19

20
21

AC input switch on the column


header cabinet lights red (A, B
channel) is normal, not light or
green light failure, notify the
relevant person.
DC input switch cabinet column
header load voltage 51V to
51V
56.3V (A / B channel) is normal,
56.3VA/B
higher or lower than the set

value fails, notify the relevant


person
deal
it. distribution
AST AC to
low
voltage
ASTAC cabinet lights normal, off failure,

notify the relevant person to


deal it.
Fixed Generators not installed,

precautions to be confirmed.
1
1. Be carefull of all equipment cabinet, if unusual sound, smoke, sparks, please notify motivation maintenance staff.
232
2. If oom temperature higher than 32 , please notify to maintenance staff.
3
3. When engine room stopped the mains power, notify to maintenance staff immediately.

Notice:

4UPSACinputoutput
4. Room UPS devices AC, the input and output power light off notify to maintenance staff immediately.
552.8V51.0V
5. Switching power supply voltage drops below 52.8V, or transmit any voltage below a column header cabinet 51.0V,
notify to motivation maintenance staff immediately.

6099295588
6. Such inspection of equipment alarm has occurred, the air switch not closed, oil machine startup
or other unusual circumstances, please immediately notify maintenance staff
and Su Tong power services (099 295 588).
7(0383001027)
7. For power maintenance staff Contact: Hu Ye Hui (Mr. Hu) 038-3001027


Machine room record sheet

4:00

8:00

12:00

16:00

20:00

ce staff.

et 51.0V,

099295588

COREROOM POWER LOG SHEET


Date:

/2013

On duty staff:
Name
Airconditioner 1
Airconditioner 2
Airconditioner 3

M:

, E:

, N:

N
1
2
3

Cabinet Name

XW0-F01-R05-N01

DC Voltage

A Voltage:
A Voltage:
A Voltage:

v;
v;
v;

B Voltage:
B Voltage:
B Voltage:

v
v
v

XW0-F01-R06-N01

DC Voltage

A Voltage:
A Voltage:
A Voltage:

v;
v;
v;

B Voltage:
B Voltage:
B Voltage:

v
v
v

XW0-F01-R07-N01

DC Voltage

A Voltage:
A Voltage:
A Voltage:

v;
v;
v;

B Voltage:
B Voltage:
B Voltage:

v
v
v

Z13

DC Cabinet

Normal

Z12

DC Cabinet Rectifier
(From top to buttom)

9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29

Z12
Z12
Z12
Z12
Z12
Z12
Z12
Z12
Z12
Z12
Z12
Z12
Z12
Z12
Z12
Z11
1-1#UPS/U11
U12
U13
U114
12-1#UPS/U15

Module 01
Module 02
Module 03
Module 04
Module 05
Module 06
Module 07
Module 08
Module 09
Module 10
Module 11
Module 12
Module 13
Module 14
Module 15
AC Cabinet
UPS
U12
U13
U14
UPS

30

ON
ON
ON

Status
OFF
OFF
OFF

ALARM
ALARM
ALARM

Abnormal

Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal

Abnormal
Abnormal
Abnormal
Abnormal
Abnormal
Abnormal
Abnormal
Abnormal
Abnormal
Abnormal
Abnormal
Abnormal
Abnormal
Abnormal
Abnormal
Abnormal
Abnormal
Abnormal
Abnormal
Abnormal
Abnormal

Off
Off
Overload
Overload
Overload
Overload
Overload
Overload
Overload
Overload
Overload
Overload
Overload
Overload
Overload
Overload
Overload
Overload
Overload
Overload
Overload

XW01-F01-R04-N13

Left side Normal


Right side Normal

Abnormal
Abnormal

Overload
Overload

31

XW01-F01-R03-N12

Left side Normal


Right side Normal

Abnormal
Abnormal

Overload
Overload

32

XW01-F01-R02-N13

Left side Normal


Right side Normal

Abnormal
Abnormal

Overload
Overload

33

XW01-F01-R01-N13

Left side Normal


Right side Normal

Abnormal
Abnormal

Overload
Overload

34
35

Battery Room
Airconditioner 1

ON

OFF

36
37
38
39
40
41
42
43
44

AC Power Room

Airconditioner 2
Breaker 1
Breaker 2
Breaker 3
Breaker 4
Breaker 5
Breaker 6
D1.4
D1.5

ON
ON
ON
ON
ON
ON
ON
Normal
Normal

OFF
OFF
OFF
OFF
OFF
OFF
OFF
Abnormal
Abnormal

1. Be carefull of all equipment cabinet, if unusual sound, smoke, sparks, please notify
motivation maintenance staff.
2. If oom temperature higher than 32 , please notify to maintenance staff.
3. When engine room stopped the mains power, notify to maintenance staff immediately.
4. UPS Room AC devices, if input and output power light off, notify maintenance staff immediately.
5. Switching power supply voltage drops below 52.8V, or transmit any voltage below
a column header cabinet 51.0V, notify to motivation maintenance staff immediately.
6. Such inspection of equipment alarm has occurred, the air switch not closed, oil machine startup
or other unusual circumstances, please immediately notify maintenance staff
and Su Tong power services (099 295 588).
7. For power maintenance staff Contact: Hu Ye Hui (Mr. Hu) 038-3001027

mmediately.

ne startup

Date
Power Check
Status
16/08/2013
15/08/2013 2 times power cut off ok

Person
Hing