Sunteți pe pagina 1din 8

Project

Job Ref.

LABOHAN DAGANG PAKEJ D - DECANTER


Jurutera Perunding Zaaba Sdn. Bhd

Section

Sheet no./rev.

ROOF SLAB

Calc. by

Date

SYAMSUL

01-Oct-16

Chk'd by

Date

App'd by

Date

Project

Job Ref.

LABOHAN DAGANG PAKEJ D - DECANTER


Jurutera Perunding Zaaba Sdn. Bhd

Section

Sheet no./rev.

ROOF SLAB

Calc. by

Date

SYAMSUL

01-Oct-16

Chk'd by

Date

App'd by

Date

Project

Job Ref.

LABOHAN DAGANG PAKEJ D - DECANTER


Jurutera Perunding Zaaba Sdn. Bhd

Section

Sheet no./rev.

ROOF SLAB

Calc. by

Date

SYAMSUL

01-Oct-16

Chk'd by

Date

App'd by

Date

Project

Job Ref.

LABOHAN DAGANG PAKEJ D - DECANTER


Jurutera Perunding Zaaba Sdn. Bhd

Section

Sheet no./rev.

ROOF SLAB

Calc. by

Date

SYAMSUL

01-Oct-16

Chk'd by

Date

App'd by

Date

Project

Job Ref.

LABOHAN DAGANG PAKEJ D - DECANTER


Jurutera Perunding Zaaba Sdn. Bhd

Section

Sheet no./rev.

ROOF SLAB

Calc. by

Date

SYAMSUL

01-Oct-16

Chk'd by

Date

App'd by

Date

Project

Job Ref.

LABOHAN DAGANG PAKEJ D - DECANTER


Jurutera Perunding Zaaba Sdn. Bhd

Section

Sheet no./rev.

ROOF SLAB

Calc. by

Date

SYAMSUL

01-Oct-16

Chk'd by

Date

App'd by

Date

RC slab designIn accordance with EN1992-1-1:2004 incorporating corrigendum January


2008 and the recommended valuesTedds calculation version 1.0.11Library item: Calc title
Library item - Show active sketchSlab definitionSlab reference name;

ROOF SLAB A-

C/1-2Type of slab;

Two way spanning with restrained edgesOverall slab

depth;

h = 200 mmShorter effective span of panel;

7000 mmLonger effective span of panel;


conditions;

lx =

ly = 12000 mmSupport

Three edges discontinuous (one long edge

continuous)Top outer layer of reinforcement;

Short span directionBottom

outer layer of reinforcement;

Short span directionLoadingCharacteristic permanent

action;

Gk = 7.1 kN/m2Characteristic variable action;

= 1.5 kN/m2Partial factor for permanent action;

Qk

gG = 1.35Partial factor for

variable action;

Q = 1.50Quasi-permanent value of variable action;

y2 = 0.30Design ultimate load;

q = G Gk + gQ Qk = 11.8 kN/m2Quasi-

permanent load;

qSLS = 1.0 Gk + 2 Qk = 7.5 kN/m2Library item

- Slab definition 2 wayConcrete propertiesConcrete strength class;


cylinder strength;

C40/50Characteristic

fck = 40 N/mm2Partial factor (Table 2.1N); C =

1.50Compressive strength factor (cl. 3.1.6);

acc = 1.00Design

compressive strength (cl. 3.1.6);

fcd = 26.7 N/mm2Mean axial tensile strength (Table

3.1);

fctm = 0.30 N/mm2 (fck / 1 N/mm2)2/3 = 3.5

N/mm2Maximum aggregate size;

dg = 20 mmReinforcement propertiesCharacteristic

yield strength;

fyk = 500 N/mm2Partial factor (Table 2.1N);

= 1.15Design yield strength (fig. 3.8);

fyd = fyk / gS = 434.8

N/mm2Library item - Material propertiesConcrete cover to reinforcementNominal cover to


outer top reinforcement;

cnom_t = 25 mmNominal cover to outer bottom

reinforcement;

cnom_b = 25 mmFire resistance period to top of slab;

Rtop = 60 minFire resistance period to bottom of slab;

Rbtm = 60 minAxia distance

to top reinft (Table 5.8);

afi_t = 15 mmAxia distance to bottom reinft (Table

5.8);

afi_b = 15 mmMin. top cover requirement with regard

to bond;

cmin,b_t = 10 mmMin. btm cover requirement with

regard to bond;

cmin,b_b = 10 mmReinforcement fabrication;

ject to QA systemCover allowance for deviation;

Sub

Dcdev = 5 mmMin. required

nominal cover to top reinft;

cnom_t_min = 15.0 mmMin. required nominal cover

to bottom reinft;

cnom_b_min = 15.0 mmPASS - There is sufficient

cover to the top reinforcementPASS - There is sufficient cover to the bottom


reinforcementLibrary item - Cover 2 way T BReinforcement design at midspan in short span
direction (cl.6.1)Bending moment coefficient;
bending moment;

sx_p = 0.0681Design

Mx_p = bsx_p q lx2 = 39.4 kNm/mLibrary item -

Project

Job Ref.

LABOHAN DAGANG PAKEJ D - DECANTER


Jurutera Perunding Zaaba Sdn. Bhd

Section

Sheet no./rev.

ROOF SLAB

Calc. by

Date

SYAMSUL

01-Oct-16

Chk'd by

Design mt 2 way restrainedReinforcement provided;

Date

App'd by

Date

10 mm dia. bars at 125 mm

centresArea provided;

Asx_p = 628 mm2/mEffective depth to tension

reinforcement;

dx_p = h - cnom_b - fx_p / 2 = 170.0 mmK factor; K =

Mx_p / (b dx_p2 fck) = 0.034Redistribution ratio;

d = 1.0K factor; K = 0.598

d - 0.18 d2 - 0.21 = 0.208K < K' - Compression reinforcement is not requiredLibrary item
- K factorLever arm;

z = min(0.95 dx_p, dx_p/2 (1 + (1 - 3.53 K)0.5))

= 161.5 mmArea of reinforcement required for bending;

Asx_p_m = Mx_p / (fyd z)

= 561 mm2/mMinimum area of reinforcement required;

Asx_p_min = max(0.26

(fctm/fyk) b dx_p, 0.0013bdx_p) = 310 mm2/mArea of reinforcement required;


Asx_p_req = max(Asx_p_m, Asx_p_min) = 561 mm2/mAscx_p_req = 0 mm2/mLibrary item As no comp reinftPASS - Area of reinforcement provided exceeds area requiredLibrary item Pass/fail bending outputCheck reinforcement spacingReinforcement service stress;

x_p = (fyk / gS) min((Asx_p_m/Asx_p), 1.0) qSLS / q = 247.8 N/mm2Library item Service stressMaximum allowable spacing (Table 7.3N);
bar spacing;

smax_x_p = 190 mmActual

sx_p = 125 mmStatusSpacing = if(smax_x_p>=

sx_p,Pass,Fail) = "Pass"PASS - The reinforcement spacing is acceptableLibrary item Output max bar spacingReinforcement design at midspan in long span direction
(cl.6.1)Bending moment coefficient; sy_p = 0.0440Design bending moment;

My_p =

bsy_p q lx2 = 25.5 kNm/mLibrary item - Design mt 2 way restrainedReinforcement


provided;

10 mm dia. bars at 150 mm centresArea provided;

Asy_p = 524 mm2/mEffective depth to tension reinforcement; dy_p = h - cnom_b - fx_p y_p / 2 = 160.0 mmK factor;

K = My_p / (b dy_p2 fck) = 0.025Redistribution

ratio;

= 1.0K factor;

K = 0.598 - 0.18

2 - 0.21 = 0.208K < K' - Compression reinforcement is not requiredLibrary item - K


factorLever arm;

z = min(0.95 dy_p, dy_p/2 (1 + (1 - 3.53K)0.5)) =

152.0 mmArea of reinforcement required for bending;

Asy_p_m = My_p / (fyd z)

= 385 mm2/mMinimum area of reinforcement required;

Asy_p_min = max(0.26

(fctm/fyk) b dy_p, 0.0013bdy_p) = 292 mm2/mArea of reinforcement required;

Asy

_p_req = max(Asy_p_m, Asy_p_min) = 385 mm2/mAscy_p_req = 0 mm2/mLibrary item - As


no comp reinftPASS - Area of reinforcement provided exceeds area requiredLibrary item Pass/fail bending outputCheck reinforcement spacingReinforcement service stress;

ssy

_p = (fyk / S) min((Asy_p_m/Asy_p), 1.0) qSLS / q = 204.0 N/mm2Library item Service stressMaximum allowable spacing (Table 7.3N);
bar spacing;

smax_y_p = 245 mmActual

sy_p = 150 mmStatusSpacing = if(smax_y_p>=

sy_p,Pass,Fail) = "Pass"PASS - The reinforcement spacing is acceptableLibrary item Output max bar spacingReinforcement design at continuous support in short span direction
(cl.6.1)Bending moment coefficient; bsx_n = 0.0909Design bending moment;

Mx_n =

sx_n q lx2 = 52.6 kNm/mLibrary item - Design mt 2 way restrainedReinforcement

Project

Job Ref.

LABOHAN DAGANG PAKEJ D - DECANTER


Jurutera Perunding Zaaba Sdn. Bhd

Section

Sheet no./rev.

ROOF SLAB

Calc. by

Date

SYAMSUL

01-Oct-16

Chk'd by

Date

App'd by

Date

S-ar putea să vă placă și