Sunteți pe pagina 1din 48

TIA Portal Workshop

Siemens AG 2015. All rights reserved.


Unrestricted

SIMATIC S7-1500: Modular Controller


for the Mid to Upper Performance Range

Page 11

Siemens AG 2015

SIMATIC S7-1500: Modules

Single-tier assembly
Multi-tier distributed ET200MP

max. 32 central modules in rack

...
PS/PM

(optional)

CPU

DI, DO,
AI, AO

PS

new power
segment

CM/CP:
- Point-to-Point
(RS232, RS485)
- PROFIBUS
- PROFINET

Page 12

TM:
- Counting
- Position sensing
max. 2 per rack
for backplane bus supply of
subsequent I/O modules

Siemens AG 2015

SIMATIC S7-1500:
Installation and Mounting Positions
Backplane is in planning stage
Profile rail with integrated
mounting rail

Vertical
Horizontal

Bus
connector
Busverbinder
If no backplane

Page 13

Siemens AG 2015

SIMATIC S7-1500:
Connection Technology/Front Connector

Release latch
Entriegelungslasche

4 jumper links
can be inserted

Wiring position
Wiring position
Strain relief by
means of cable ties

Page 14

Operating position

Siemens AG 2015

SIMATIC S7-1500: CPU-Display Overview

Every S7-1500 CPU is delivered with a Display


Two sizes depending on the CPU type
1.36 up to CPU1513
2.4
as of CPU1515
Has its own MLFB
can be ordered as replacement part
CPU can be operated without the Display
Removal and insertion possible during running operation
CPU stays in RUN
Bilingual display (menu and error/message texts)
Language can be switched during running operation

Page 15

Siemens AG 2015

SIMATIC S7-1500: CPU-Display Menu and Colors


Main menu items and their meaning:
Overview (CPU status: name, type, MLFB, version)
Diagnostics (display diagnostics buffer, message display)
Settings (CPU settings: addresses, time, operating mode, CPU Reset,
protection level, unlock Display when password set)
Modules (status information of modules in the system)
Display (display settings: brightness, display language,
energy-saving times, MLFB, version)

Colors of status information and their meaning:


green RUN of CPU, RUN with pending alarm message
yellow STOP or CPU HOLD
red

Error

white

Connection setup or connection to CPU lost


Page 16

Siemens AG 2015

SIMATIC S7-1200/1500: Memory Cards

1
2
3
4
5

Serial number of the SD card


Product version
Order number
Card size
Slide switch for write-protect
(must not be write-protected)

SIMATIC Memory Card in the


S7-1200 / S7-1500:
Load memory
Distribution of programs (only S7-1200)
Firmware update
Documentation
Memory Card Binding
Unlinked DBs
Archiving of data
Module exchange without PG

Write with:
Commercially available SD card reader
Field PG

Page 18

Siemens AG 2015

TIA Portal: Portal View and Project View

Project View

Hierarchical project structuring


All editors, parameters and data accessible

Portal View

Task-oriented
Fast project entry

Page 32

Siemens AG 2015

Portal View
Portals

Actions of the selected portal

Hardware
and
network
configuration

Block Editor
New project

Drive
parameterization

Selection window for


the selected action

Migration
HMI
configuration
User interface language
Accessible
devices

Switch to Project view

Page 33

Siemens AG 2015

Project View
Task Cards
(tools)

Project
navigation
(Project tree)

Working area

Details view

Task bar
(opened
editors)

Inspector window
- Properties
- Info output
- Diagnostics

Page 34

Siemens AG 2015

Project Tree
Project

CPU
CPU program

Block group

PLC tags
Local modules
(central I/O)
Device group
Distributed I/O

Language settings
for the entire project

HMI device

Online access
SIMATIC Card Reader
Page 35

Siemens AG 2015

Online Tools,
Configuring and Parameterizing the Hardware
with CPU

Task Card

online Status,
Diagnostics
offline Configuration,
Parameterization

Page 37

Siemens AG 2015

Online Connection via Industrial Ethernet:


IP Address and Subnet Mask

MAC Address:

MAC Address:

08-00-06-01-74-10

08-00-06-01-74-20

Subnet Mask:

255.255.255.0

Subnet Mask:

255.255.255.0

IP Address:

192.168.111.10

IP Address:

192.168.111.12

Subnet

Node

Page 38

Subnet

Node

Siemens AG 2015

Online Access:
Accessible Devices in the Portal View

Call online
accesses of
Project view

Page 39

Siemens AG 2015

Accessible Devices in the Project View:


CPU Online Access: Reading-out the Diagnostics Buffer

Show / hide
interfaces

Details for the entry line


selected above

Page 40

Siemens AG 2015

Accessible Devices in the Project View:


CPU Online Access: CPU-RUN/STOP, MRES

Page 41

Siemens AG 2015

Online Access to the CPU:


IP Address, Name, Time, FW Update, Memory Card

Page 42

Siemens AG 2015

Resetting the CPU using the Mode Selector Switch


RUN
STOP
MRES
RUN
STOP
MRES
RUN
STOP
MRES
RUN
STOP
MRES
RUN
STOP
MRES
RUN
STOP
MRES

1. Set the mode selector switch to STOP

2. Press and hold the mode selector switch in the MRES


position until the RUN/STOP LED has flashed 2x slowly

RUN/STOP LED
of the S7-1500

then let go again

within 3 sec !!!

STOP
3. Press and hold the mode selector switch in the MRES
position until the RUN/STOP LED begins to flash quickly
then let go again

Result:
4. Set the mode selector switch to RUN
A CPU restart is carried out

Page 43

With inserted PROGRAM card


Memory reset
Without inserted card
Reset to factory settings

Siemens AG 2015

Components of the "Devices & Networks" Editor

Connection
configuration

Topology
configuration

Page 44

Device
configuration
and
module
parameter
assignment

Siemens AG 2015

Devices & Networks:


Device View (Hardware Configuration)

Address parameter assignment


(right) section in the working area

Module parameter assignment


Properties in the Inspector window

Page 45

Siemens AG 2015

Setpoint Configuration: Creating a Hardware Station


Portal view

Project view

Page 46

Siemens AG 2015

Inserting / Deleting a Module

Possible
slots

Deleting in the Device


view deletes
individual modules

Inserting from the


Hardware catalog

1xR

Deleting in the
Network view
deletes entire station

Page 47

Siemens AG 2015

Area for Modules Not Plugged In

Open / close area

Page 48

Siemens AG 2015

Uploading a Hardware Station into the Project (1)


(Hardware with Parameterization and Software)

Select the desired node


(device)

Page 49

Siemens AG 2015

Uploading a Hardware Station into the Project (2)


(Hardware with Parameterization and Software)

Page 50

Siemens AG 2015

CPU Properties: Ethernet Address

Select CPU

Page 51

Siemens AG 2015

Compiling the Hardware Configuration and


Downloading it into the CPU

1xR

1xR

Status / Error
information

Page 56

Siemens AG 2015

Status LEDs of the S7-1500 CPU

CPU defective;
Memory Card defective

RUN/STOP LED

CPU in RUN mode


CPU in startup (transition from STOPRUN)
CPU in STOP mode
CPU Reset or Firmware Update running
ERROR LED

Program error, system error or diagnostic problem exists


MAINT LED

Maintenance request of an I/O module exists


Firmware Update successfully completed

Page 57

Siemens AG 2015

Status LEDs of the Central I/O of the S7-1500 CPU


Module defective

RUN LED

Module ready for operation


Module running, but has no valid parameter assignment
ERROR LED

Module error or diagnostic problem exists

Channel status

Channel error exists;


e.g. wire break, short-circuit ...
DI/DO
1-Status of channel
AI/AO
Channel is parameterized and OK

Page 58

Siemens AG 2015

Task Description:
Creating a Project with an S7-1500 Station

Page 59

Siemens AG 2015

Exercise 3:
Erasing the SIMATIC Memory Card of the CPU

Page 60

Siemens AG 2015

Exercise 11: Addresses of the DO Module

Page 61

Siemens AG 2015

Exercise 12: Addresses of the AI Module

Page 62

Siemens AG 2015

Exercise 13: Compiling the Device Configuration


and downloading it into the CPU

Compile
HW station

Download HW
station into CPU

1xR

Page 63

Siemens AG 2015

Types of Program Blocks

Operating system

DB

DB

Cycle
Time

OB_Cycle
(OB1)

Process

Organization
blocks
FB

Error
Legend:
OB = Organization block
FB = Function block
FC = Function
DB = Data block

FC

FB

FC

The maximum nesting depth


depends on the CPU!

FB
FB with
Instance DB
Page 71

Siemens AG 2015

Structured Programming

Linear Program

Program Partitioned
into Areas

Structured Program

Recipe A

OB_
Cycle
(OB1)

OB_
Cycle
(OB1)

Recipe B
Mixer

OB_
Cycle
(OB1)

Pump

Outlet

Outlet

All instructions are found


in one block (usually in
the Organization
block OB_Cycle)

The instructions for the individual


functions are found in individual
blocks. OB_Cycle calls these
blocks one after the other.

Page 72

Re-usable functions are programmed


in individual blocks.
OB_Cycle (or other blocks) calls
these blocks and passes on the
relevant data.

Siemens AG 2015

Creating a New OB

Page 75

Siemens AG 2015

Adding a New Block

Page 76

Siemens AG 2015

Block Properties (All):


Programming Language, Time Stamps
Selecting the
Programming
language

Time stamps

Page 77

Siemens AG 2015

Block Properties: Know-how Protection

1xR

Page 78

Siemens AG 2015

Block Programming

Insert network

Display Favorites
On/Off

Add further input

Page 79

Siemens AG 2015

Block Calls

Drag & Drop

Page 80

Siemens AG 2015

Downloading Blocks into the CPU

1xR

Page 81

Siemens AG 2015

Downloading Blocks into the CPU:


S7-1500 - Memory Concept
SD Card: CPU load memory
PLC tag table
PLC data types
Block comments/symbols
Hardware configuration
Code work memory:
Logic blocks (FC, FB, OB)
Data work memory:
Global DBs
Instance-DBs
Technology objects

1xR

Retentive memory:
Retentive variables from:
Global DBs
Instance-DBs
Technology objects
Bit memories
SIMATIC timers / counters
Other memory areas
Bit memories
SIMATIC timers / counters
Process images(PII/PIQ)
Page 82

Siemens AG 2015

Monitoring a Block

Monitor Block
On / Off

Page 83

Siemens AG 2015

Hardware Diagnostics

1xR

Page 120

Siemens AG 2015

Online & Diagnostics


Online &
Diagnostics

Page 121

Siemens AG 2015

S-ar putea să vă placă și