Page | 4-13
C1000-R3.1
Drive Settings
The Drive Settings screen allows an operator to adjust and monitor drive settings associated with the run
sequence of the Control Philosophy. See Table 4-4: Falcon Concentrator Run Set points and Status.
Hertz (Hz)
0 - 60
40
Hertz (Hz)
0 - 60
30
Hertz (Hz)
0 - 60
1.5
Hertz (Hz)
0 - 60
20
Page | 4-14
C1000-R3.1
Pressure Setup
The Process EUH (Engineering Unit High) of each instrument can be changed here, though it is imperative it
matches the units and range the instrument is scaled to for the Falcon to operate as intended. See Table 4-6:
Pressure Setting.
Unit
Range
Factory
Setting
Description
Segment Drop
psi
0-10
Segment Jump
psi
0-10
Segment Timer
0-999
120
Closed Pressure
psi
200-300 psi
250 psi
High Operating
Pressure
200-300 psi
230 psi
Low Operating
Pressure
50-200 psi
120 psi
Auto
On / Off
On
Manual
On / Off
Off
PSI
0-300 psi
PID Control
Manual PID SP
Page | 4-16
C1000-R3.1
Caution: Do not change HMI parameter settings outside given ranges without factory
authorization. Changing some settings may adversely affect machine operation and void warranty.
Resets
Emergency stop button is pressed
Maintenance interval has been reached
Drive Fault
Pressure Low shutdown alarm
Vibration High shutdown alarm
Rinse OFF
When the START button is pressed, the VFD accelerates the rotor to the run speed and feed is introduced. The
Concentrator will process feed continuously. Pressing normal STOP, or if a vibration danger limit shut down
or other fault occurs in the Rinse OFF mode, the machine will stop with no rinsing.
The machine will remain in this state until the operator selects a different operating mode, stops the machine,
or if a shutdown fault is initiated.
Rinse AUTO
When the START button is pressed, the VFD accelerates the rotor to the Middle speed and feed is introduced.
After the Feed U/F delay time is done it accelerates to the Run speed.
Sepro Mineral Systems Corp.
Page | 4-20
C1000-R3.1
Basket
Belt
Grease Motor
0 - 15000 hours
2500 hours
Maintenance
Maintenance
0 - 15000 hours
0 - 15000 hours
2500 hours
2500 hours
The above tables are to guide the supervisor in making changes to the operating parameters, but these should
not be changed unless the user is aware of the purpose of each and what may result.
Note: The upcoming screens can be opened by any level.
Trending Screens
There are 2 Trending Screens, The Real time Trend logs process data as it happens, and only captures a
snapshot of the previous minute of operation.
Drive speed
Pressure
Vibration
Sentronic
Alarms Screens
Alarm Button
Press the Alarm button in the lower left hand corner of each screen to display all the active alarms on the
machine.
Page | 4-19
C1000-R3.1
Maintenance
The Falcon Concentrator has been programmed to log runtime hours and report critical maintenance intervals.
Both the current hour set points and the time remaining to the next service are displayed here. When a
maintenance service is due, an alarm message will be displayed across the bottom of the current screen and in
the Alarm History Table.
These alarms will not shut down the machine and are resettable once the maintenance service is done. See also
suggested maintenance frequency schedules and instructions in section 6. Maintenance. See Table 4-8:
Maintenance Alarm Settings and Table 4-9: Maintenance Alarm Settings.
Maintenance
Menu
Each hour
counter can be
set for a
scheduled
maintenance
interval
Description
Range
Factory Setting
0 - 15000 hours
0 - 15000 hours
0 - 15000 hours
0 - 15000 hours
0 - 15000 hours
500 hours
2500 hours
2500 hours
2500 hours
2500 hours
Page | 4-18
C1000-R3.1
Pressure Alarm
The Pressure Setup screen is used to change the alarm Set Points and enable or disable alarms associated
with each instrument. See Table 4-7: Pressure Alarm Set Points.
Unit
Range
Factory
Setting
Description
Low Warning
Psi
100
Self-Reset
Low Shutdown
n/a
90
Latch
Deadband
Psi
10
n/a
Delay
Seconds
30 sec
n/a
Out of Range
n/a
ON
Self-Reset
Enable / Disable
n/a
ON
n/a
Page | 4-17
C1000-R3.1
Vibration Setup
The Vibration Setup Screens allow an operator to change the alarm set points and enable or disable alarms
associated with the Vibration Sensor. The EUH of the instrument can also be changed here, though it is
imperative it matches the units and range the instrument is scaled to for the Falcon to operate as intended. See
Table 4-5: Vibration Alarm Set Points.
Type
Description
Vibration has exceeded the set point. The
Falcon will adjust pressure to go to under
flow and attempt another run cycle
After a 1st Vibration Warning, Pressure
stabilization delay time
If the vibration has reached critical levels
very quickly the Falcon will auto rinse and
stop
1st Vibration
Warning
Percentage
70%
Latch
2nd Vibration
Warning
Seconds
30sec
Latch
High Vibration
Shutdown
Seconds
90%
N/A
Delay
Seconds
10sec
n/a
Out of Range
n/a
ON
n/a
Enable
n/a
ON
n/a