Sunteți pe pagina 1din 10

System Configuration

Long Haul

Proprietary and
Confidential

Furnishing Long Haul Systems

Proprietary and
Confidential

Evolution METRO Long Haul N+0 Terminal/


N+1 with STM-1 LPT
Plug-in main data interfaces (STM-1 elec. Shown below)
STM-1
STM-4
Gigabit Ethernet (no need for DXC)
Plug-in auxiliary interfaces
EOW
64 kb/s
2/1.5 Mb/s Wayside
External alarms
DXC and node configuration for 1+0/1+1/2+0 configurations. Same Interface
configurations like access METRO.

LIU STM-1 / STS-3

LIU STM-1 / STS-3

RIU 155

RIU 155

FAN

LIU STM-1 / STS-3

LIU STM-1 / STS-3

RIU 155

RIU 155

FAN

LIU STM-1 / STS-3

LIU STM-1 / STS-3

SU

Supervisory Unit

LIU STM-1 / STS-3

LIU STM-1 / STS-3

Line Interface Slot

Line Interface Slot

RIU 155

RIU 155

FAN

RIU 155

RIU 155

FAN

Radio Interface Slot Radio Interface Slot FAN

Proprietary and
Confidential

Evolution METRO Long Haul N+1 terminal/


N+1 with 100Mb/s Ethernet LPT
An LPT 100Mb/s Ethernet traffic can be inserted using the SU Ethernet port
number 2. An SU-Ethernet mapper license is required for this configuration.

LIU STM-1 / STS-3

LIU STM-1 / STS-3

RIU 155

RIU 155

FAN

LIU STM-1 / STS-3

LIU STM-1 / STS-3

RIU 155

RIU 155

FAN

LIU STM-1 / STS-3

LIU STM-1 / STS-3

LIU STM-1 / STS-3

SU

Supervisory Unit

Line Interface Slot

Line Interface Slot

RIU 155

RIU 155

FAN

RIU 155

RIU 155

FAN

Radio Interface Slot

Radio Interface Slot

Proprietary and
Confidential

FAN

N+1 Terminal, STM-4/STM-1/Ethernet

Common protection channel

LIU
STM-1
LIU
STM-1

MDS

STM-1 and STM4

RIU
IFU-4

Flexible configuration
STM-1 and Ethernet

RIU

LIU
GIU

MDS

RIU
RIU
IFU-3

LCAS on Ethernet Traffic


MDS

RIU
RIU
IFU-2

SU
LIU
STM-4

MDS

RIU
RIU
IFU-1

Proprietary and
Confidential

Multiple Terminals in One Rack

It is possible to install two or more terminals in


one frame. The frame can have maximum four
WG runs this can be four individual directions or
it can be either two directions with dual
polarization or two directions with Space
Diversity.
The maximum number of XCVRs in one frame is
ten. The IFU shelves can occupy six 1U slots.
This means that the largest combination on IFU
is one 4 IFU shelf + one 2 IFU shelf.

Proprietary and
Confidential

Four-direction Node

Proprietary and
Confidential

Long Haul Terminals with Add/Drop

All METRO split mount configurations can also be made as indoor terminals with RF-channel branching. The
example above shows traffic nodes using DXC unit or Frame to add/drop in METRO Long Haul configuration

Proprietary and
Confidential

7+1 Add/Drop Site

This example shows a site with two 7+1 terminals. One or two DXC Frames can be included and each
of the DXCs can connect to two of the channels in the terminal. STM-1/OC-3 LIU cards must be
included for all channels and they must be connected with cables.
Proprietary and
Confidential

Evolution METRO Long Haul Split Mount


3+1 terminal/3+1 with 100Mb/s Ethernet LPT

Coaxial cable

LIU STM-1 / STS-3

Supervisory Unit

Line Interface Slot

R F C O U P LE R

F1 & F2
F3 & F4

A N TE N NA

X CV R
LIU STM-1 / STS-3

LIU STM-1 / STS-3

SU

Branching Unit

Coaxial cable

X CV R

Coaxial cable

X CV R

Coaxial cable

XCV R

An LPT 100Mb/s Ethernet traffic can be inserted using the SU Ethernet port
number 2. An SU-Ethernet mapper license is required for this configuration.

Line Interface Slot

RIU 155

RIU 155

FAN

RIU 155

RIU 155

FAN

Radio Interface Slot

Radio Interface Slot

FAN

Proprietary and
Confidential

S-ar putea să vă placă și