Sunteți pe pagina 1din 30

IAB_projkkkkh Documentation

Reference / Version

Integrated Architecture Builder

IAB_projkkkkh

Project Documentation
Reference
Version

Tuesday, October 18, 2016 - 12:34

/
Author

Table of Contents:
Integrated Architecture Builder........................................................................1
1 Overview of Project 'IAB_projkkkkh'..............................................................4
1.1 IAB Software Information:........................................................................4
1.2 Integrated Architecture...........................................................................5
1.3 ControlLogix............................................................................................ 7
1.4 View........................................................................................................ 9
1.5 EtherNet/IP............................................................................................ 11
1.6 Project's System List.............................................................................13
1.7 Project Errors/Warnings.........................................................................13
1.8 Project's Network list............................................................................. 13
1.9 Project's hardware platforms list...........................................................13
1.10 Architecture View................................................................................ 14
2 Bill of Materials............................................................................................ 15
2.1 Consolidated BOM.................................................................................15
2.2 Positional BOM....................................................................................... 15
2.3 Organized BOM...................................................................................... 16
3 Network Details........................................................................................... 18
3.1 Network 'EtherNet/IP001'......................................................................18

3.1.1
3.1.2
3.1.3
3.1.4
3.1.5

EtherNet/IP network status : Ok.............................................18


Graphics:................................................................................18
Performance Data:.................................................................20
Layout Information:................................................................20
Network Connections.............................................................21

3.1.5.1 EtherNet/IP001..........................................................................21
3.1.5.1.1 Switches.............................................................................. 21
3.2 Network 'EtherNet/IP002'......................................................................22

3.2.1
3.2.2
3.2.3
3.2.4
3.2.5

EtherNet/IP network status : Ok.............................................22


Graphics:................................................................................22
Performance Data:.................................................................24
Layout Information:................................................................24
Network Connections.............................................................25

3.2.5.1 EtherNet/IP002..........................................................................25
3.2.5.1.1 Switches.............................................................................. 25
3.2.5.1.2 Linear Networks...................................................................25
4 Hardware Platforms..................................................................................... 27
4.1 Platform 'CLX_SS.1_CLogix001'.............................................................27

4.1.1 Graphics:................................................................................27
4.1.2 Performance Data:.................................................................27
4.1.3 Layout Information:................................................................28
4.2 Platform 'Device002'.............................................................................29

4.2.1 Graphics:................................................................................29
4.2.2 Performance Data:.................................................................29
4.2.3 Layout Information:................................................................29
5 Appendix:.................................................................................................... 30

1 Overview of Project 'IAB_projkkkkh'


1.1 IAB Software Information:
Integrated Architecture Builder software is a tool designed to assist you in defining an
automation configuration. While Integrated Architecture Builder Software has been designed
and tested for accuracy and Bill of Material completeness, the underlying variables and
assumptions of the tool may cause actual results to vary from expected results. Users of
Integrated Architecture Builder software must independently determine to their own satisfaction
the applicability of the resulting configuration and must assume responsibility for the use of the
resulting configuration and bill of material. Integrated Architecture Builder software provides
informational data on expected performance results. Rockwell Automation is not liable for the
correctness of this data.
Processor Checks:
The Processor Chassis Checkers check the processor and any associated I/O and devices. The
checker examines power consumption of all chassis, estimates memory requirements for the
processor(s), and counts connections for the Processor and any local communication modules
necessary to handle the network bandwidth. Any device that is "owned" by this processor will be
accounted for when performing the check.
ControlNet Network Checks:
The ControlNet Wizard checks the device connections, network cabling components, and
additional performance information about the network. Given certain information about device
connectivity to processors and basic network setup information, the ControlNet wizard will check
details on scheduled and unscheduled bandwidth, propagation delay, and Network Update
Time. Results are based on approximate
DeviceNet Network Checks:
The DeviceNet Wizard checks the device connections and network cabling (trunk, taps and
drops). It also verifies correct network sizing (power consumption, maximum length and Baud
rate).
EtherNet Network Checks:
The EtherNet Wizard checks the device connections, network cabling components, and
additional performance information about the network. Given certain information about device
connectivity to processors and basic network setup information, the EtherNet wizard will check
details on CIP / TCP connections, I/O packets per second, and HMI packets per seconds.

1.2 Integrated Architecture


The Convergence of Control and Information for Plantwide Optimization
The Rockwell Automation Integrated Architecture system helps you to build a
business in which information flows across your organization so you can better
address key market challenges:

Productivity
Improve PRODUCTIVITY with better asset utilization and system
performance.
o Develop a standard set of engineering objects you can use across
all of your applications
o Merge the production floor with the enterprise system to improve
data flow and make faster, more informed business decisions
o Improve uptime, increase speed and simplify integration using
intelligent devices
o Take advantage of a single network infrastructure

Innovation
Cultivate INNOVATION with increased system flexibility and technical risk
mitigation.
o Invest less time in development so that you can spend more time
creating new intellectual property
o Quickly make production changes to better meet market demands
o Mix industrial, business and commercial technologies to solve
business challenges in new ways
o Share best practices

Globalization
Promote GLOBALIZATION with easy access to actionable, plantwide
information.
o Easily extract, share and use information across your enterprise
and around the world directly from manufacturing assets like your
controllers
o Track your manufacturing assets on a global basis
o Take advantage of a single, global standard

Sustainability
Support SUSTAINABILITY with extended product lifecycles and better
asset utilization.
o Reduce waste by specifying a system in a footprint that meets your
needs
o Reduce energy costs by eliminating the need to "over-design"

Streamline required assets and simultaneously reduce storage,


energy costs, and waste materials

How does the Integrated Architecture system accomplish this? By leveraging


exceptional, industry-leading features that include:
Functionality for a full range of automation
applications with common equipment and standards

Multiple Disciplines

Scalable Dimensions

EtherNet/IP

Real-Time Information

Knowledge Integration

Offerings that are right-sized by product,


architecture and core multiple discipline functionality
A single network of IT-friendly Ethernet for information, I/O
and motion
Live data and open access throughout your power
and control system, enterprise and supply chain
Premier integration of device and system to
maximize and secure your intellectual property

The Integrated Architecture system provides the foundation to drive plantwide


optimization efficiently and effectively, helping companies to respond
competitively to the economy and changes in consumer demand.

1.3 ControlLogix
For manufacturers, OEMs and Systems Integrators in virtually every industry, the Logix
Control Platform increases productivity while reducing total cost of ownership.
Unlike conventional architectures, the Logix Control Platform provides fully integrated,
scalable solutions for the full range of automation disciplines including discrete, motion,
process control, batch, drive systems and safety using a single control platform, a single
development environment and using a single, open communication protocol. The
platform enables you to re-use engineering designs and practices to reduce
development time and cost, respond more quickly to customer or market demands,
reduce maintenance costs and downtime and easily gain access to actionable plant and
production information for improved management and decision-making.
ControlLogix Programmable Automation Controller
The Most Powerful, Most Expandable Controller

ControlLogix brings together the benefits of the Logix platformcommon programming


environment, common networks, common control engineto provide you with the
performance your application requires in an easy-to-use environment. As part of the
Logix Control Platform, you receive tight integration between the programming software,
controller and I/O to reduce development time and cost at commissioning and during
normal operation.

Mix multiple controllers,


networks and I/O without
restrictions to address all
disciplines

Mix standard and safety


The ControlLogix programmable automation controller (PAC) features a modular control
platform with virtually infinite expansion of controllers, networks and I/O. With memory
options up to 32MB, ControlLogix controllers support intensive process applications and
provide fast processing of motion instructions in a single integrated solution.
ControlLogix provides modular network communications that let you purchase only what
you need. Interface using ControlLogix communication modules via a ControlLogix
gateway without the need for a processor in the gateway chassis, or interface directly to
a ControlLogix processor.
You may also combine any number of EtherNet/IP, ControlNet, DeviceNet, HART,
FOUNDATION fieldbus, or other networks for maximum communications flexibility. Or,
you may route and bridge between CIP (Common Industrial Protocol) networks with no
controller overhead.

ControlLogix controllers also support redundant architectures with no additional


programming or customized controllers for high availability. The primary controller
automatically updates the secondary with any data changes needed to keep it
synchronized.
Additionally, standard ControlLogix products are
certified by TUV for use in Safety Integrity Level (SIL)
and SIL 2 applications. By using the same platform
and development software as standard control
systems, you may reduce development costs.

In terms of I/O, the ControlLogix platform provides a


full range of digital, diagnostic digital, analog, motion
control, and specialty I/O to meet a variety of application needs. Use any of the I/O
modules in the local chassis of a ControlLogix controller or in a chassis linked to a
ControlLogix controller across ControlNet or EtherNet/IP networks.
Development Environment
Streamline engineering with outstanding ease-of-use
With RSLogix 5000, only one software package is needed for discrete, process, batch,
motion, safety and drive-based applications. RSLogix 5000 offers an easy-to-use, IEC61131-3
compliant interface, symbolic programming with structures and arrays and a comprehensive
instruction set that serves many types of applications. It provides ladder logic, structured
text, function block diagram and sequential function chart editors for program development
as well as support for the S88 equipment phase state model for batch and machine control
applications. RSLogix 5000 can help:

reduce programming and ease startup and commissioning

ease diagnostics and troubleshooting

increase overall plant productivity

1.4 View

Visualization: To get to most out of your production assets,, you need the right
information, in the right place, at the right time, and in the right format. From
simple pushbuttons or indicators to plant or enterprise-wide production
information, the actions you take are based on the available information.
Rockwell Automation visualization platforms provide you with a scalable, unified
suite of operator interface and supervisory-level monitoring solutions that share
the same development software, offering faster development and
implementation, flexibility and lower total cost of ownership.
Premier integration into Integrated Architecture gives you visibility into your
operations, which can lead to business success and performance when and
where you need it.
Information: Operational excellence is no longer a luxuryits a strategic
imperative, especially in industries driven by fast response to consumer demand,
stringent quality and compliance, pressure from global competitors and a
constant need to reduce operating costs.
The FactoryTalk Integrated Production and Performance Suite offers a modular
integrated approach to deploying information solutions at machine, line, plant and
enterprise levels. Now you can synchronize the information in your business and
plant floor systems; monitor process and discrete control system in real-time to
identify issues before they become real problems; implement lean tolls; track
orders from dock to dock; simplify data collection and create a window into your
plants day-to-day operations.

This suite of manufacturing applications addresses the production disciplines


common to most enterprises. Modules can be deployed individually or in
combination with each other to create solutions for todays production
management challenges. Interoperability is assured through the FactoryTalk
Services Platform, a standards-based services oriented architecture for shared
services and data.

1.5 EtherNet/IP
Globally the #1 industrial network by every meaningful measure.
Largest installed base with several million nodes
300+ vendors
Thousands of product lines available
Preferred network of Rockwell Automation customers
EtherNet/IP uses standard Ethernet and TCP/IP exclusively.
Same technology used on the Internet and in your companys enterprise
networks
Reuse Ethernet training and IT expertise
Mix commercial and industrial devices
Easily integrate into your enterprise
EtherNet/IP offers the broadest industrial solutions and is proven in the most
demanding applications. Our leading adoption and expertise in EtherNet/IP for
industrial applications is why Rockwell Automation is a Strategic Alliance Partner
with Cisco, working together to provide products, solutions, services, education
and standards development to aid the convergence of IT and manufacturing
around EtherNet/IP.
EtherNet/IP Features
Portability across different data links (Ethernet and WiFi) and IP routability
throughout the plant-wide network infrastructure and across WANs
Seamless bridging and routing requires no additional assets such as
proxies or store-and-forward devices
Flexible and secure system implementation allows IT and manufacturing
to collaborate easily to deploy and maintain security, reliability, and quality
of service across the enterprise
Scalable, future-ready network architecture using open standards,
enabling you to quickly and efficiently deploy new technologies and
capabilities
Tested and validated design and implementation guidance, as well as best
practices for a converged Industrial/IT network architecture
Integration with the Enterprise
Easily integrates into existing Ethernet and TCP/IP installations, with no
special requirements, products, or conditions to meet
Uses commercial products such as Ethernet switches/routers/firewalls, IP
cameras and IP telephony, as well as technologies like wireless and power
line carrier
Common tools for both industrial and enterprise networks require no
special training, tools, or knowledge to leverage the IT workforce
Future-proofs your application and networks by leveraging the ongoing
advancements of standard Ethernet and TCP/IP

Security
Our Security Solutions provide unique capabilities and expertise to reduce risk
and enable greater operational uptime in control system networks.
Network and Security Services
Our Network and Security Services team can collaborate with you to achieve
your production and business goals. Enhanced with Cisco Systems, Rockwell
Automation is a Cisco Solution Technology Integrator (STI). As a STI partner, we
can provide you with a combined solution, incorporating both Rockwell
Automation and Cisco Systems hardware and services.

1.6 Project's System List


This Project contains the following Systems:
Subsystem: CLX_SS.1
1.7 Project Errors/Warnings
The General Checker has found the following warnings:
CLX_SS.1_CLogi Warning
This chassis requires a control power
x001
connection. A connection can be assigned in
the Control Power Wizard.

1.8 Project's Network list


This Project contains the following networks:
Network Type
Network Name
Network Status
EtherNet/IP
EtherNet/IP001
Ok
EtherNet/IP
EtherNet/IP002
Ok
1.9 Project's hardware platforms list
This Project contains the following Hardware platforms:
HW Platform Type
HW Platform Name
ControlLogix
CLX_SS.1_CLogix001
View
Device002

1.10 Architecture View

2 Bill of Materials
The list prices shown in this tool are reference points used by your distributor or
Rockwell Automation to calculate your extended net prices and do not include
applicable discounts and taxes. To obtain your extended net pricing for products,
contact Rockwell Automation or your authorized distributor.
2.1 Consolidated BOM
Qty

Catalog #

Description

1
1
1
2
5
1
2
1
1
1
1
1

1756-A7
1756-PB72
1756-L83E
1756-IB32
1756-TBCH
1756-OB32
1756-IF16
1756-OF8
1756-TBNH
DESKTOP PC
NIC-CARD
1585J-M4TBJM-2

1
1

9355-WABSNENE
9324RLD700NXENE
9357-CNETL3
9701VWSCWAENE

1756 Chassis 7 slots


19.2 - 32 VDC Power Supply (5V @ 10 Amp)
Logix5580E Controller With 10 Mbytes Memory
10-31 VDC Input 32 Pts (36 Pin)
36 Pin Screw Clamp Block With Standard Housing
10-31 VDC Output 32 Pts (36 Pin)
Analog Input - Current/Voltage 16 Pts (36 Pin)
Analog Output - Current/Voltage 8 Pts (20 Pin)
20 Position NemA Screw Clamp Block
Desktop PC
EtherNet NIC Card for PC
Patchcord: RJ45 Male / RJ45 Male, 4-Conductor, Teal TPE,
Flex Rated, 2 meters (6.56 feet)
RSLinx Single Node
Studio 5000 Professional Edition

1
1

RSNetWorx for ControlNet


FactoryTalk View SE Client

($ - USD)
Unit Price
558.00
1,010.00
12,400.00
522.00
94.40
739.00
1,700.00
2,200.00
76.20
N/A
N/A
41.46

($ - USD) Total
Price
558.00
1,010.00
12,400.00
522.00
94.40
739.00
1,700.00
2,200.00
76.20
N/A
N/A
41.46

591.00
8,160.00

591.00
8,160.00

1,640.00
2,750.00

1,640.00
2,750.00

Total:

$ 32,482.06

($ - USD)
Unit Price

($ - USD) Total
Price

Subtotal:

$ 0.00

Included in
Hardware
Section
41.46

Included in
Hardware
Section
41.46

Included in
Hardware
Section
Subtotal:

Included in
Hardware
Section
$ 41.46

558.00

558.00

2.2 Positional BOM


Pos/Slot

Catalog #

Description
Networks

EtherNet/IP002 : Linear001
1

1756-L83E

(CLX_SS.1_CLogix001) Logix5580E Controller With


10 Mbytes Memory

1585J-M4TBJM-2

DESKTOP PC

Patchcord: RJ45 Male / RJ45 Male, 4-Conductor,


Teal TPE, Flex Rated, 2 meters (6.56 feet)
(Device002) Desktop PC

Hardware
CLX_SS.1_CLogix001
N/A

1756-A7

1756 Chassis 7 slots

N/A
0
1
1.1
2
2.1
3
3.1
4
4.1
5
5.1
6
6.1

1756-PB72
1756-L83E
1756-IB32
1756-TBCH
1756-IB32
1756-TBCH
1756-OB32
1756-TBCH
1756-IF16
1756-TBCH
1756-IF16
1756-TBCH
1756-OF8
1756-TBNH

N/A
PCI Slot 1

DESKTOP PC
NIC-CARD

19.2 - 32 VDC Power Supply (5V @ 10 Amp)


Logix5580E Controller With 10 Mbytes Memory
10-31 VDC Input 32 Pts (36 Pin)
36 Pin Screw Clamp Block With Standard Housing
10-31 VDC Input 32 Pts (36 Pin)
36 Pin Screw Clamp Block With Standard Housing
10-31 VDC Output 32 Pts (36 Pin)
36 Pin Screw Clamp Block With Standard Housing
Analog Input - Current/Voltage 16 Pts (36 Pin)
36 Pin Screw Clamp Block With Standard Housing
Analog Input - Current/Voltage 16 Pts (36 Pin)
36 Pin Screw Clamp Block With Standard Housing
Analog Output - Current/Voltage 8 Pts (20 Pin)
20 Position NemA Screw Clamp Block

1,010.00
12,400.00
522.00
94.40
522.00
94.40
739.00
94.40
1,700.00
94.40
1,700.00
94.40
2,200.00
76.20
Subtotal:

1,010.00
12,400.00
522.00
94.40
522.00
94.40
739.00
94.40
1,700.00
94.40
1,700.00
94.40
2,200.00
76.20
$ 21,899.20

N/A
N/A
Subtotal:

N/A
N/A
$ 0.00

591.00
Subtotal:

591.00
$ 591.00

8,160.00

8,160.00

Subtotal:

$ 8,160.00

1,640.00
Subtotal:

1,640.00
$ 1,640.00

2,750.00

2,750.00

Subtotal:

$ 2,750.00

Total:

$ 35,081.66

($ - USD)
Unit Price

($ - USD) Total
Price

Subtotal:

$ 0.00

Included in
Hardware

Included in
Hardware

Device002
Desktop PC
EtherNet NIC Card for PC

Rockwell Software
RSLinx
N/A

9355-WABSNENE

RSLinx Single Node

Studio 5000
N/A

9324RLD700NXENE

Studio 5000 Professional Edition

RSNetworx
N/A

9357-CNETL3

RSNetWorx for ControlNet

FactoryTalk View Site Edition Client


N/A

9701VWSCWAENE

FactoryTalk View SE Client

2.3 Organized BOM


Qty

Catalog #

Description
Networks

EtherNet/IP002 : Linear001
1

1756-L83E

(CLX_SS.1_CLogix001) Logix5580E Controller With 10


Mbytes Memory

1585J-M4TBJM-2

DESKTOP PC

Patchcord: RJ45 Male / RJ45 Male, 4-Conductor, Teal TPE,


Flex Rated, 2 meters (6.56 feet)
(Device002) Desktop PC

Section
41.46

Section
41.46

Included in
Hardware
Section
Subtotal:

Included in
Hardware
Section
$ 41.46

558.00
1,010.00
12,400.00
522.00
94.40
739.00
1,700.00
2,200.00
76.20
Subtotal:

558.00
1,010.00
12,400.00
522.00
94.40
739.00
1,700.00
2,200.00
76.20
$ 19,299.60

N/A
N/A
Subtotal:

N/A
N/A
$ 0.00

591.00
Subtotal:

591.00
$ 591.00

8,160.00

8,160.00

Subtotal:

$ 8,160.00

1,640.00
Subtotal:

1,640.00
$ 1,640.00

2,750.00

2,750.00

Subtotal:

$ 2,750.00

Total:

$ 32,482.06

Hardware
CLX_SS.1_CLogix001
1
1
1
2
5
1
2
1
1

1756-A7
1756-PB72
1756-L83E
1756-IB32
1756-TBCH
1756-OB32
1756-IF16
1756-OF8
1756-TBNH

1
1

DESKTOP PC
NIC-CARD

1756 Chassis 7 slots


19.2 - 32 VDC Power Supply (5V @ 10 Amp)
Logix5580E Controller With 10 Mbytes Memory
10-31 VDC Input 32 Pts (36 Pin)
36 Pin Screw Clamp Block With Standard Housing
10-31 VDC Output 32 Pts (36 Pin)
Analog Input - Current/Voltage 16 Pts (36 Pin)
Analog Output - Current/Voltage 8 Pts (20 Pin)
20 Position NemA Screw Clamp Block

Device002
Desktop PC
EtherNet NIC Card for PC

Rockwell Software
RSLinx
1

9355-WABSNENE

RSLinx Single Node

Studio 5000
1

9324RLD700NXENE

Studio 5000 Professional Edition

RSNetworx
1

9357-CNETL3

RSNetWorx for ControlNet

FactoryTalk View Site Edition Client


1

9701VWSCWAENE

FactoryTalk View SE Client

3 Network Details
3.1 Network 'EtherNet/IP001'
3.1.1 EtherNet/IP network status : Ok
3.1.2 Graphics:
Zone: Plantwide View

Zone: IndustrialZone

Zone: CellArea001

3.1.3 Performance Data:


Ethernet Media Utilization
3.1.4 Layout Information:
IndustrialZone
CellArea001

0.0%

3.1.5 Network Connections


3.1.5.1 EtherNet/IP001
3.1.5.1.1 Switches

3.2 Network 'EtherNet/IP002'


3.2.1 EtherNet/IP network status : Ok
3.2.2 Graphics:
Zone: Plantwide View

Zone: IndustrialZone

Zone: CellArea001

3.2.3 Performance Data:


Ethernet Media Utilization

0.0%

3.2.4 Layout Information:


IndustrialZone
CellArea001
Linear001
A#10.0.0.2, CLX_SS.1_CLogix001, [0], 1756-L83E
A#10.0.0.3, Device002, DESKTOP PC

3.2.5 Network Connections


3.2.5.1 EtherNet/IP002
3.2.5.1.1 Switches
3.2.5.1.2 Linear Networks
Node #

Device / Switch

Port #

IP Address

Cable

Next Device / Switch

Port #

IP Address

CLX_SS.1_CLogix001 / Slot 0
(1756-L83E)

Port 1

10.0.0.2

1585JM4TBJM-2
(2.0m)

Device002 (DESKTOP PC)

PCI Slot
1

10.0.0.3

Linear001

4 Hardware Platforms
4.1 Platform 'CLX_SS.1_CLogix001'
4.1.1 Graphics:

4.1.2 Performance Data:


Ctlr1 (Controller 1756-L83E in slot 0)
EtherNet/IP Nodes
Motion Position Axes
Memory Used
Memory Available
Remaining Memory
User Task Minimum Period
User Task Rung Capacity
Continuous Task Scan Time
Input Cycle Utilization (Drive to
Controller)
Output Cycle Utilization (Controller to
Drive)
Motion Task I/O Cycle Utilization
Logix Controller Utilization
Logix System Minimum Time Slice

0
0
141 KB
10.0 MB
9.9 MB
0.0 msec
33245 rungs
0.0 msec
0.0%
0.0%
0.0%
0.0%
5.0%

Usage Breakdown for Ctlr1


Chassis / Device
EtherNet/IP
Name
Nodes
CLX_SS.1_CLogi 0
x001(Local)
Device002
0

Motion Position
Axes
0

Memory Used

2.0 KB

139 KB

(Comm Module 1756-L83E in slot 0, on network EtherNet/IP002)


Motion Packets per Second (PPS)
0
I/O Packets per Second (PPS)
0
HMI Packets per Second (PPS)
0
Utilization
0.0%
CIP Connections
5 (994 rem)
TCP Connections
1 (511 rem)
Motion Percent Used
0.0%
I/O Percent Used
0.0%
HMI Percent Used
0.0%
Processor Checker Warnings:
1. This chassis requires a control power connection. A connection can be
assigned in the Control Power Wizard.
Control Power Information
Control Power Status:

Not Satisfied by Control Power

Backplane Power Information


Power Supply:
5V Used:
5V Remaining:
24V Used:
24V Remaining:
Power Used:
Power Remaining:

1756-PB72
2190 mA
7810 mA
346 mA
2454 mA
19660 mW
55340 mW

Field Power Information


Field Power Status:

Not Satisfied by Field Power

Network Connectivity
1756-L83E (slot 0)

Connected to
EtherNet/IP002/Linear001

4.1.3 Layout Information:


Slot #
N/A

Catalog #
1756-A7

Additional Information

N/A
0

1756-PB72
1756-L83E

1
1.1
2
2.1
3
3.1
4
4.1
5
5.1
6
6.1

1756-IB32
1756-TBCH
1756-IB32
1756-TBCH
1756-OB32
1756-TBCH
1756-IF16
1756-TBCH
1756-IF16
1756-TBCH
1756-OF8
1756-TBNH

connected to network 'Linear001' at


address 10.0.0.2

4.2 Platform 'Device002'


4.2.1 Graphics:

4.2.2 Performance Data:


Control Power Information
Control Power Status:

Not Required

Field Power Information


Field Power Status:

Not Supported

Network Connectivity
DESKTOP PC

Connected to
EtherNet/IP002/Linear001

4.2.3 Layout Information:


Slot #
N/A

Catalog #
DESKTOP PC

Additional Information

PCI
Slot 1

NIC-CARD

5 Appendix:

S-ar putea să vă placă și