Sunteți pe pagina 1din 4

Medium-voltage

Substation Circuit
Breakers
Powersub Type FVR
Vacuum Circuit Breaker

FVR Circuit Breaker

FVR Breaker Detail

110, 125, 150 and 200 kV BIL


Advanced Technology for Improved Reliability
For over 100 years, Square D products from Schneider Electric have been
setting standards in quality for the electric industry and serving utilities with
highly reliable products. By combining the latest developments in circuit
breaker technology with world-renowned quality, the Powersub Type FVR
Vacuum Substation Circuit Breakers from Square D Services are the most
advanced medium voltage circuit breakers available.

Compliance to ANSI standards


Designed and tested to comply with IEEE/ANSI standards for outdoor
circuit breakers.

ISO 9001 certification


Designed and manufactured in a facility that is Quality Systems
Certified by Underwriters Laboratories, Inc. to ISO 9001.

10

12

11

13

14

Arc-resistant construction
As standard, the 600 - 2000 A ratings of the FVR have
arc-resistant construction in accordance with EEMAC and IEC
standards for Type B enclosures.

Benefits
High-speed operation
Interrupting time of three cycles or less.
Long life
Hermetically sealed interrupters protect contacts from corroding elements
and contamination.
Ease of maintenance
Interrupter assemblies and contact wear indicators accessible via
a bolted panel.
Reliability
A minimum of moving parts on the motor-driven, spring-charged
Type RI mechanism.
Durability
Robust design tested to the highest IBC-2000 seismic standard.
Other seismic standards may be evaluated upon request.
Flexibility
Breaker height is adjustable from minimum to maximum in 3 in. increments.
Component Commonality
Utilizes Type RI operating mechanism/coils/motor, which are
commonly used among many Square D medium-voltage circuit breakers.

FVR Breaker Detail

FVR breaker
1. Highdetail
Voltage Compartment
110, 125, 150
kV BIL
2. and
Low200
Voltage
Compartment
3. Adjustable Legs
1. High-voltage
compartment
4. Entrance
Bushings
2. Low-voltage
compartment
5. Current Transformers
3. Adjustable legs
6. Flexible Connector
4. Entrance bushings
7. Vacuum Interrupter Bottle
5. Current transformers
8. Drive Bar Assembly
6. Flexible connector
9. interrupter
Stand Off Insulator
7. Vacuum
bottle
10.
8. Drive bar Mechanism
assembly
9. Stand11.
offAuxiliary
insulator Switches
12. Relay & Instrument Door
10. Mechanism
13. switches
Control Mounting Panel
11. Auxiliary
Base Channel
12. Relay 14.
andGalvanized
instrument door
13. Control mounting panel
14. Galvanized base channel

Standard features

Additional features and ratings

Window for viewing status indicators and operation counter.


Ground pads located on both sides of enclosure. A #4 cable connects
from the roof and HV/LV compartment to the ground pads to insure a
solidly grounded enclosure.
Painted adjustable legs with galvanized base channels.
All external hardware is stainless steel.
Optimized relay panel (32 58 in. W x 33 78 in. H) for instrumentation.
12-pole auxiliary switch (6 a & 6 b contacts), latch check switch
and emergency cutout switch standard.
All outer doors latch open at approximately 160 degrees, except the
200 kV BIL unit, which latch open to 120 degrees.
Type RI mechanism with integral manual charging handle.

15 38 kV, 1200 4000 A, up to 40 kA.


Self-cooled up through 3000 A (no fan circuitry).
High-voltage panels are light (~25 lbs) for ease of
removal and reinstallation.
Height adjustable range of 24 in. for 110/125 kV
BIL and 21 in. for 150/200 kV BIL.
Two pad-lockable handles on each outer door.
Hinged doors utilized on common access areas.

FVR Vacuum Circuit Breaker Ratings


Substation Circuit
Breaker Catalog
Number

FVR 1 06 11 12A
FVR 1 08 11 16A

Voltage
Max.
kV rms

15.5

Insulation Level
Test Voltage
Continuous
Low
Current at 60 Frequency Impulse
Hz, A, rms
kV rms
kV Crest

600
800

50

110

Short Circuit
Current
kA rms
at Max. kV

Max.
Symmetrical
Interrupting
Capability
kA rms

12

12

16

16

Rated
Permissible
Tripping Delay
Y Seconds

Three-second
Current
Close and
Carrying
Latching
Capability
Capability
kA rms
kA Peak

12

32

16

43

FVR 1 12 11 12A

12

12

12

32

FVR 1 12 11 16A

16

16

16

43

FVR 1 12 11 20A

20

20

25

25

FVR 1 12 11 31A

31.5

FVR 1 12 11 25A

15.5

1200

50

110

20

54

25

68

31.5

31.5

85
108

FVR 1 12 11 40A

40

40

40

FVR 1 20 11 12A

12

12

12

32

FVR 1 20 11 16A

16

16

16

43

FVR 1 20 11 20A

20

20

25

25

FVR 1 20 11 31A

31.5

31.5

31.5

85

FVR 1 20 11 40A

40

40

40

108

FVR 1 20 11 25A

15.5

2000

50

110

20

54

25

68

FVR 1 30 11 12A

12

12

12

32

FVR 1 30 11 16A

16

16

16

43

FVR 1 30 11 20A

20

20

25

25

FVR 1 30 11 31A

31.5

31.5

31.5

85

FVR 1 30 11 40A

40

40

40

108

FVR 1 30 11 25A

15.5

3000

50

110

20

54

25

68

FVR 1 35 11 20A

20

20

20

54

FVR 1 35 11 25A

25

25

25

68

31.5

31.5

40

40

FVR 1 35 11 30A

15.5

3500

50

110

FVR 1 35 11 31A

31.5

85

40

108

FVR 1 40 11 20A

20

20

20

54

FVR 1 40 11 25A

25

25

25

68

31.5

31.5

40

40

FVR 1 40 11 31A

15.5

4000

50

110

FVR 1 40 11 40A
FVR 2 12 12 12A

31.5

85

40

108

12

12

12

32

16

16

16

43

20

20

20

54

FVR 2 12 12 25A

25

25

25

68

FVR 2 20 12 25A

12

12

12

32

FVR 2 12 12 16A
FVR 2 12 12 20A

FVR 2 20 12 25A
FVR 2 20 12 25A

27

27

1200

2000

60

60

125
(150)

125
(150)

FVR 2 20 12 25A
FVR 2 12 15 25A
FVR 2 20 15 31A

27

1200
2000

80

150

16

16

20

20

25

25

31.5

31.5

16

43

20

54

25

68

31.5

85

FVR 3 12 15 12A

12

12

12

32

FVR 3 12 15 16A

16

16

16

43

20

20

20

54

FVR 3 12 15 25A

25

25

25

68
85

FVR 3 12 15 20A

38

1200

80

150

FVR 3 12 15 31A

31.5

31.5

31.5

FVR 3 20 15 12A

12

12

12

32

FVR 3 20 15 16A

16

16

16

43

20

20

20

54

FVR 3 20 15 25A

FVR 3 20 15 20A

38

2000

80

150

25

25

25

68
85

FVR 3 12 15 31A

31.5

31.5

31.5

FVR 3 12 20 12A

12

12

12

32

FVR 3 12 20 16A

16

16

16

43

20

20

25

25

FVR 3 12 20 20A
FVR 3 12 20 25A

38

1200

80

200

20

54

25

68

All ratings
are based on
three-cycle
interrupting
time and
voltage range
factor, k = 1.0

Type
FVR Vacuum
Voltage class
1 15.5 kV
2 27 kV
3 38 kV
Continuous
current rating
06 600 A
08 800 A
12 1200 A
20 2000 A
30 3000 A
35 3500 A
40 4000 A
BIL rating
11 110 kV
12 125 kV
15 150 kV
20 200 kV
Interrupting
rating
12 12 kA
16 16 kA
20 20 kA
25 25 kA
31 31.5 kA
40 40 kA

( ) Indicates
optional BIL
ratings.

B
Pad Mounting Detail
H

Lifting Eyes
(2) Places

Height
of
Live
Part

Dimensions 15, 27 and 38 kV Type FVR

Copper Clad
Ground Pad
NEMA 2 Hole
Pattern (2 Places)
V

Rear

A
Access

8 in. x 14 in.
Control Conduit
Entrance Area

Panel
Emergency
FVR = 110,
125, 150
kV BIL
Trip Device

C
B

D
Status
Indicator

(8) 1.135 in. Dia. Holes


Typically Use 0.875 in. - 9 in.
Pad Bolts
Mounting
Detail
UNC
for Mounting

Operations
Counter

Book Pocket
and Nameplate
on Inside
Rear Door

3.00 in. (Typ.)

H
Front / Mechanism
Side

Lifting Eyes
(2) Places

Padlockable
Handles: Front
and Rear Door

Height
of
Live
Part
L

Painted Legs (Adjustable)


Hot Dip
Galvanized
Copper
Clad Base
Ground Pad
NEMA 2 Hole
Pattern (2 Places)
V

Rear

A
Access
Panel

8 in. x 14 in.
Control Conduit
Entrance Area

Emergency
Trip Device

Status
Indicator

(8) 1.135 in. Dia. Holes


Typically Use 0.875 in. - 9 in.
UNC Bolts for Mounting

Operations
Counter

Padlockable
Handles: Front
and Rear Door

Book Pocket
and Nameplate
on Inside
Rear Door

3.00 in. (Typ.)

Front / Mechanism Side

Painted Legs (Adjustable)

Hot Dip Galvanized Base

FVR = 200 kV BIL


D

D
J

Pad Mounting Detail


H

Access
Panel

8 in. x 14 in.
Control Conduit
Entrance Area

Emergency
Trip Device

C
B

U
Stainless Steel
Ground Pad
NEMA 2 Hole
Pattern (2 Places)

Rear

Height
of
Live
Part

V
R

Status
D
Indicator

(8) 1.135 in. dia. Holes


Typically Use 0.875 in.
9 UNC
for Mounting
Pad Bolts
Mounting
Detail

Operations
Counter

Front/Mechanism Side
H

Lifting Eyes
(2) Places

Padlockable
Handles: Front
and Rear Door

Book Pocket
and Nameplate
on Inside
Rear Door

11.00 (Typ.)

Height
of
Live
L
Part

Painted Legs (Adjustable)

Rear

200 kV BIL

Breaker Access
A
Type
Panel

D*

4.25

38.00

27.00

G 8 in. x 14
H in.
Control Conduit
Entrance
Area
21.00
44.00

27.00

21.00

(8) 1.135
in. dia. Holes
21.00
52.50
1.75
Typically Use 0.875 in.
21.00
52.50
1.75
9
UNC Bolts
for Mounting

110 kV BIL

32.62

Emergency
15.00Trip Device
55.50

125 kV BIL

32.62

4.25

38.00

150 kV BIL

15.00
55.50
Status

32.62

Indicator
17.00
63.50

4.25

38.00

27.00

200 kV BIL

38.50

19.50
74.00
Operations

4.25

54.00

43.00

44.00

(Max)

(Min)

(Max)

(Min)

2.00

20.00

39.12

31.94

R7.94Q

122.38

98.38

125.88 101.88

Padlockable
44.00
31.75

2.00

20.00

39.12

31.94

7.94

122.38

98.38

125.88 101.88

44.00
31.75
and Rear
Door

17.25

39.12

25.94

4.94

122.75
101.75 126.25 105.25
K

50.75
27.00
Book Pocket

11.00 (Typ.)
29.50
39.12

25.94

4.94

137.75 116.75 140.75 119.75

and Nameplate
68.50
22.85

Counter
Front/Mechanism Side

D* = 13.00 for 3000 A, 3500 A & 4000 A (110 kV BIL)


Note: Dimensions subject to change and not for construction.
All dimensions are approximate and are in inches.

Stainless
SteelBase
Hot Dip
Galvanized
Ground Pad
NEMA 2 Hole
Pattern (2 Places)

200 kV BIL

For more information call 888-SQUARED or


visit us online at www.SquareD-Services.com.

(Max)

V
(Min)

Handles: Front

on Inside
Rear Door

2010 Schneider Electric Industries SAS, All Rights Reserved.

Lifting Eyes
(2) Places

Painted Legs (Adjustable)


Why Choose
Square D Services
L

Hot Dip Galvanized


Base
As part of Schneider Electric, Square
D Services
offers a broad range of service solutions to
support any manufacturers electrical distribution
equipment. Whether the solution is refurbishment,
replacement, maintenance or recommendations
to optimize your existing system, our nationwide
network of qualified experts offers a complete
service package.

Schneider Electric USA, Inc.


9870 Crescent Park Drive
West Chester, OH 45069
Tel: 513-777-4445
Fax: 513-755-5028
www.schneider-electric.us
Document Number 1910BR0902

This document has been


printed on recycled paper

April 2010

cw

S-ar putea să vă placă și