Documente Academic
Documente Profesional
Documente Cultură
Analyze Experiment - Ef AF
File name: <Untitled>
Estimated effects for Ef AF (ef)
Effect
Estimate
Stnd. Error
average
0,27
0,0284898
A:Rel agua-precursor
-0,015
0,0348927
B:Rel etanol-precursor
-0,0475
0,0348927
C:Temperatura
0,0025
0,0348927
AA
-0,1075
0,0513607
AB
0,01
0,0493457
AC
-0,07
0,0493457
BB
-0,0625
0,0513607
BC
-0,115
0,0493457
CC
0,2075
0,0513607
Standard errors are based on total error with 5 d.f.
V.I.F.
1,0
1,0
1,0
1,01111
1,0
1,0
1,01111
1,0
1,01111
The StatAdvisor
This table shows each of the estimated effects and interactions. Also shown is the standard error of each of the effects,
which measures their sampling error. Note also that the largest variance inflation factor (V.I.F.) equals 1,01111. For a
perfectly orthogonal design, all of the factors would equal 1. Factors of 10 or larger are usually interpreted as indicating
serious confounding amongst the effects.
To plot the estimates in decreasing order of importance, select Pareto Charts from the list of Graphical Options. To test
the statistical significance of the effects, select ANOVA Table from the list of Tabular Options. You can then remove
insignificant effects by pressing the alternate mouse button, selecting Analysis Options, and pressing the Exclude button.
Df
1
1
1
1
1
1
1
1
1
5
14
Mean Square
0,00045
0,0045125
0,0000125
0,0106673
0,0001
0,0049
0,00360577
0,013225
0,0397442
0,002435
F-Ratio
0,18
1,85
0,01
4,38
0,04
2,01
1,48
5,43
16,32
P-Value
0,6852
0,2315
0,9457
0,0905
0,8474
0,2152
0,2779
0,0672
0,0099
Optimize Response
Goal: maximize Ef AF
Optimum value = 0,435494
Factor
Rel agua-precursor
Rel etanol-precursor
Temperatura
Low
3,0
10,0
200,0
High
4,0
20,0
250,0
Optimum
3,27899
10,0
250,0
The StatAdvisor
This table shows the combination of factor levels which maximizes Ef AF over the indicated region. Use the Analysis
Options dialog box to indicate the region over which the optimization is to be performed. You may set the value of one or
more factors to a constant by setting the low and high limits to that value.
CC
+
-
BC
AA
AC
B:Rel etanol-precursor
BB
A:Rel agua-precursor
AB
C:Temperatura
0
2
3
Standardized effect
0,38
0,35
Ef AF
0,32
0,29
0,26
0,23
0,2
3
Rel agua-precursor
10
20
Rel etanol-precursor
200
250
Temperatura
Superficie de respuesta:
Ef AF
0,43
0,38
0,33
0,28
0,23
0,18
0,13
3
3,2
3,4
3,6
Rel agua-precursor 3,8
4
200
210
230
220
Temperatura
240
250
Ef AF
0,43
0,38
0,33
0,28
0,23
0,18
0,13
10
12
14
16
Rel etanol-precursor 18
20
200
210
230
220
Temperatura
240
250
Ef AF
0,43
0,38
0,33
0,28
0,23
0,18
0,13
3
3,2
3,4
3,6
Rel agua-precursor 3,8
4
10
12
16
14
Rel etanol-precursor
18
20
V.I.F.
1,0
1,0
1,0
1,01111
1,0
1,0
1,01111
1,0
1,01111
The StatAdvisor
This table shows each of the estimated effects and interactions. Also shown is the standard error of each of the effects,
which measures their sampling error. Note also that the largest variance inflation factor (V.I.F.) equals 1,01111. For a
perfectly orthogonal design, all of the factors would equal 1. Factors of 10 or larger are usually interpreted as indicating
serious confounding amongst the effects.
To plot the estimates in decreasing order of importance, select Pareto Charts from the list of Graphical Options. To test
the statistical significance of the effects, select ANOVA Table from the list of Tabular Options. You can then remove
insignificant effects by pressing the alternate mouse button, selecting Analysis Options, and pressing the Exclude button.
Df
1
1
1
1
1
1
1
1
1
5
14
Mean Square
0,0078125
0,0338
0,0006125
0,00485192
0,0009
0,004225
0,0000519231
0,0049
0,0660519
0,004565
F-Ratio
1,71
7,40
0,13
1,06
0,20
0,93
0,01
1,07
14,47
P-Value
0,2477
0,0417
0,7291
0,3498
0,6756
0,3802
0,9192
0,3477
0,0126
Optimize Response
Goal: maximize Ef MB
Optimum value = 0,478899
Factor
Rel agua-precursor
Rel etanol-precursor
Temperatura
Low
3,0
10,0
200,0
High
4,0
20,0
250,0
Optimum
4,0
19,9421
200,081
The StatAdvisor
This table shows the combination of factor levels which maximizes Ef MB over the indicated region. Use the Analysis
Options dialog box to indicate the region over which the optimization is to be performed. You may set the value of one or
more factors to a constant by setting the low and high limits to that value.
CC
+
-
B:Rel etanol-precursor
A:Rel agua-precursor
BC
AA
AC
AB
C:Temperatura
BB
0
2
Standardized effect
0,37
0,33
Ef MB
0,29
0,25
0,21
0,17
0,13
3
Rel agua-precursor
10
20
Rel etanol-precursor
200
250
Temperatura
Superficies de respuesta:
Estimated Response Surface
Temperatura=225,0
Ef MB
0,0
0,05
0,1
0,15
0,2
0,25
0,3
0,35
0,4
0,45
0,5
0,5
0,4
Ef MB
0,3
0,2
0,1
0
3
3,2
3,4
3,6
3,8
10
20
18
16
14
12
Rel etanol-precursor
Rel agua-precursor
0,5
Ef MB
0,4
0,3
0,2
0,1
0
3
3,2
230
3,4
3,6
3,8
Rel agua-precursor
200
210
240
250
220
Temperatura
0,5
Ef MB
0,4
0,3
0,2
0,1
0
10
12
14
16
Rel etanol-precursor
18
20
250
240
230
220
210 Temperatura
200