Sunteți pe pagina 1din 5

dTCU Integration Procedure

Section

Page

1 LAPTOP SETUP:
SETUP Description
NOTE: If you have any problems with any steps of this MOP, DO NOT PROCEED,
Contact your PM immediately.
The Steps below need to be executed in the specified sequence on all impacted nodes.

SET COMPUTER IP TO:


192.168.1.2
255.255.255.0
192.168.1.1

LAUNCH REFLECTIONS TCU INTEGRATION 192.168.1.1 PORT 23


TELNET

login: admin
password: hidden

LAUNCH REFLECTIONS TCU INTEGRATION 192.168.1.1 PORT 23


TELNET

login: admin
password: hidden

LAUNCH FTP PROGRAM (USER [TCU] PSWD [TCU]) PORT 22

1. Double click on the file msftpsrvr.exe to start the mini-sftp server program
on your PC.
2. Change these values on the mini-sftp-server as below
3. The user and password is TCU
4. Then click on start button to start the SFTP server

2 SITE SPECIFIC STEP-BY-STEP


Check the power LED indicator is lit.
1.

Connect an Ethernet cable from the PC LAN port to the Console port on the TCU

2.

The TCU local maintenance IP address is 192.168.1.1/24.

Check current HW revision


Log-in to the TCU and check the current TCU HW level as follows:

3.

OSmon> getmoattribute STN=0,Equipment=0


STN=0,Equipment=0; instanceId= 0;
STN=0,Equipment=0; serialNumber= CB4B682659;
STN=0,Equipment=0; productRevision= R1C;
STN=0,Equipment=0; productNumber= KDU 137 596/2;
STN=0,Equipment=0; manufacturingDate= 20100111;
OperationSucceeded

The productRevision must be R1C or later.

Check current TCU Software


OSmon>

4.

rev

--------- Software modules --------cesopsn_pwr.chk CXC 172 8394


R1N01
dhcpr.chk
CXC 172 9220/1
R1N01
hdlc_pwr.chk
CXC 172 6448/3
R1N01
inetapps.chk
CXC 172 2851/3
R1N01
inetr.chk
CXC 172 9038/2
R1A
lcf_cp.chk
CXC 112 3683/1
R4B01
oam.chk
CXC 112 3423/3
R1N01
p_relayr.chk
CXC 172 2708/3
R1N01
profiler.chk
CXC 112 3517/1
R1E01
secmgrr.chk
CXC 172 2710/4
R1N01
sftpr.chk
CXC 172 2711/4
R1N01
snc.chk
CXC 112 3424/2
R1N01
sshdr.chk
CXC 172 2713/4
R1N01
telnetd.chk
CXC 172 2715/3
R1N01
bootstrap.chk CXC 112 3428/3
R1N01
loader.drv
CXC 112 3429/3
R1N01
bsp.drv
CXC 112 3427/3
R1N01
--------- Firmware modules --------PBOOT
CXC 112 3777/1
-------- TAR files present --------Primary:
part1.tar
CXP102080/1
Backup:
part1.tar
CXP102080/1
Running on the primary application.

R1E01

R1T01
R1T01

Upgrade TCU Software


The software upgrade requires an SFTP server running on your PC. The software
and configuration files will be downloaded from your PC to the TCU.
Start the SFTP server on your PC and configure it with the username and password
TCU and set Root path to C:.
Enter the following commands:
OSmon>

uselocalsftp on

OSmon> startswsession
OperationSucceeded

OSmon>

downloadsw 1
sftp://TCU:TCU@192.168.1.2/2_19089_CXP102165_2XA/tcu02_sw.tar
5.

OperationSucceeded
OSmon> getswsessionstatus
DownloadInProgress
OperationSucceeded

Wait up to 5 minutes for the software download to complete.


OSmon> getswsessionstatus
DownloadCompleted
OperationSucceeded

When the software download is complete, activate the software using the following command:
OSmon> activatesw
OperationSucceeded

The TCU will restart and connectivity will be lost.

Check TCU Software upgrade was successful


Log-in to the TCU and enter the following commands:
OSmon> getswsessionstatus
ActivationCompleted
OperationSucceeded
OSmon> endswsession
OperationSucceeded

Check the software revision and verify that the primary software is the latest version and the
TCU is running on the primary application as follows:

6.

OSmon> rev
--------- Software modules --------cesopsn_pwr.chk
CXC 172 8394/4
p_relayr.chk
CXC 172 2708/4
snc.chk
CXC 112 3424/3
dhcpr.chk
CXC 172 9220/3
oam.chk
CXC 112 3423/4
profiler.chk
CXC 112 3517/3
sshdr.chk
CXC 172 2713/5
hdlc_pwr.chk
CXC 172 6448/4
secmgrr.chk
CXC 172 2710/5
telnetd.chk
CXC 172 2715/4
inetapps.chk
CXC 172 2851/4
sftpr.chk
CXC 172 2711/5
inetr.chk
CXC 172 9038/3
lcf_cp.chk
CXC 112 3683/3
bsp.drv
CXC 112 3427/4
bootstrap.chk
CXC 112 3428/4
loader.drv
CXC 112 3429/4

R1J02
R1J02
R1J02
R1L01
R2C01
R1J02
R1J02
R1J02
R1J02
R1J02
R1J02
R1J02
R2D01
R1J01
R2C01
R1L01
R1J02

--------- Firmware modules -------PBOOT


CXC 112 3777/1

R1E01

-------- TAR files present -------Primary:


/tmp/hvdZoaNXSh/part1
Backup:
part1.tar
CXP102080/1

CXP102084_1

R2D01

R1T01

Running on the primary application.

Load configuration script


7.

Simply Copy and paste the script ,


NOTE:- Take care about Forcedcommit , after forcedcommit line TCU takes restart , so you
need to again copy paste remaining part in TCU.